• Title/Summary/Keyword: 가동 접점

Search Result 15, Processing Time 0.022 seconds

Towards reducing acoustical high-frequency noise of a direct current relay via contact structure (직류 계전기의 접촉구조에 의한 고주파수 소음저감)

  • Junhyeok, Yang;Jongseob, Won;Wonjin, Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.691-697
    • /
    • 2022
  • In this work, a straightforward component design of a direct current (DC) relay equipped in electric vehicles is discussed. The work aims to provide and evaluate effective measures for reducing high-frequency sound from the DC relay carrying electric power. From the operation experiments for the relay, it is observed that noise is caused by the resonance from the forced vibration by the electromagnetic repulsive force originating at the area of electric contacts with a resonance frequency of around 710 Hz ~ 730 Hz. A finite element model for the relay was established to conduct vibration mode analysis, consisting of stationary and movable contacts and a contact spring. Vibration mode analysis indicates that in the resonance frequency, the movable contact with two-point contacts experiences rotational vibration mode. For the proposed relay with a three-point contact, vibration mode analyses give reasonable results of reducing noise at that frequency. Furthermore, for the fabricated relays with the three-point contact, similar results have been obtained. In conclusion, one can see that the proposed measures provide one of the feasible solutions to the reduction of relay noise.

Analysis Method for Damage Patterns of Low Voltage Switches for PL Judgment (PL 판정을 위한 저압용 스위치의 소손 패턴 해석기법)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2010
  • The purpose of this study is to examine the structure and heat generation mechanism of low voltage switches used to turn on or off the power supply to an indoor lighting system and investigate how the fixtures and movable contacts of the switches are damaged depending on the types of energy sources in order to secure the judgment base for expected PL disputes. Based on the Korean Standard (KS) testing method for incombustibility, this study applied a general flame to the switch. In addition, current was supplied to the switch using the PCITS (Primary Current Injection Test System). The ambient temperature and humidity were maintained at $22{\pm}2^{\circ}C$ and 40~60% respectively while performing the test. It is thought that the switch generated heat due to a defective connection of the wire and clip, insulation deterioration and defective contact of the movable contact, etc. The surface of the switch damaged by the general flame was uniformly carbonized. When the flame source was removed, the fire on the switch was extinguished naturally. From the result obtained by disassembling the switch carbonized by the general flame, it could be seen that fixtures and movable contacts remained in comparatively good shape but the enclosure, clip support, movable contact, indicating lamp, etc. showed carbonization and discoloration. In the case of the switch damaged by overcurrent, the clip connecting the wires, clip support, etc. showed almost no trace of damage, but the fixtures, movable contact, indicating lamp, etc. were severely carbonized. That is, the sections with high contact resistance were intensively damaged and showed a damage pattern indicating that carbonization progressed from the inside to the outside. Therefore, it is possible to judge the initial energy source by analyzing the characteristics of the carbonization pattern and the metal fixtures of damaged switches.

Development of a Small Current Breaking Prediction Technology in such a complex GCB as a Dual motion GCB (양방향 구동 차단기와 같은 복잡한 차단기의 소전류 차단 평가기술 개발)

  • Lee, Hyeong-Goo;Song, Tae-Hun;Kim, Yeon-Pung;Choi, Byeong-Hwa;Yun, Ja-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1796-1798
    • /
    • 2004
  • 기존의 단방향 차단기 소전류 차단성능 해석에서는 해석의 편의를 위해 실제 차단기의 고정부(고정아크접점과 피스톤)를 움직이게 하고 가동부(퍼퍼 실린더 노즐 등)를 고정시켜 놓고 해석을 하였다. 기존 차단기에서는 이런 식으로 해석을 하여도 아무런 문제가 발생하지 않았으나 이번 당사 모델인 550kV 50kA 1점절 차단기는 차단성능 향상을 위해 양방향으로 구동이 이루어지고 있어서 기존 방식으로 해석을 하는 것이 거의 불가능하다. 따라서 이번 연구에서는 상용프로그램인 PHOENICS를 이용하여 실제 차단기와 마찬가지로 가동부가 움직이도록 모의하는 방법을 개발하여 550kV 1점절 차단기의 소전류 차단성능을 평가하였으며, 앞으로 개발될 모든 복잡한 형태의 차단기도 쉽게 해석할 수 있는 계기를 마련하였다.

  • PDF

Investigation on effect and the characteristics of grease hardening in 23kV $SF_6$ gas switchgear (23kV 가스절연개폐기의 윤활제 고착 및 영향 검토)

  • Kim, Dong-Myung;Kwon, Tae-Ho;Chun, Sung-Nam;Choi, Sun-Kyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.246-248
    • /
    • 2005
  • 본 논문은 23kV 가스절연개폐기에서의 윤활제 고착시 발생되는 현상을 조사하였다. 내부 개폐접점부의 마찰저항을 줄이고 가동전극의 윤활한 동작을 위해 사용되는 그리스 (grease)를 과다하게 도포할 경우 고착과 함께 가동전극의 미끄럼운동에 영향을 주는 것이 확인되었다. 영향 평가로는 물성시험과 투 개방 음향특성을 분석하였다. 본 논문의 결과는 개폐장치의 제조품질 개선 및 정전감소에 기여할 것으로 사료된다.

  • PDF

The Hazard of Ignition on the Bimetal Type Thermostat Molded by Phenol Resin (페놀수지로 몰딩된 바이메탈식 서모스탯의 발화위험성)

  • Park, Y.G.;Lee, S.H.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.63-73
    • /
    • 2007
  • In this paper, we discussed the hazard of ignition on the bimetal type thermostat molded by phenol resin with case study and accelerated aging test. We experimented three type thermostats molded by phenol resin which are used on hot/cold water dispenser. On the case study, the thermostat was origin of 6re and dry tracking occurred around it's moveable contactor. On the accelerated aging test, the more thermostat was switched, the more damaged it become. One of the A-type thermostats that is similar type on the case study fired around moveable contactor. We therefore confirmed that the tracking around the moveable contactor of bimetal type thermostat molded by phenol resin could be origin of fire and it is available to reduce of fire that using noncombustible material for molding of bimetal type thermostat.

  • PDF

Dielectric Recovery Characteristics between Poles of 800kV Model Interrupter -I. Effects or separation between Moving Main Contact and Moving Arcing Contact- (800kV 모델차단부의 극간 절연회복특성 -I. 가동주접점과 가동아크접점간 이격거리의 변화에 대한 영향분석-)

  • Shin, Y.J.;Park, K.Y.;Chang, K.C.;Song, K.D.;Jeong, J.K.;Song, W.P.;Kang, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.270-273
    • /
    • 1994
  • The capacitive current breaking capability as well as the short circuit current breaking capability is a very important factor in the performance of a circuit breaker. The dielectric recovery capability between poles should be considered in the desist of a circuit breaker because approximately two times of the maximum power system voltage might be applied between poles after the capacitive current be interrupted. The electric field and flow field analyses were utilized in the calculation of dielectric recovery characteristics between poles of 800kV model interrupter. The results show that the separation between moving main contact and moving arcing contact will affect to decrease significantly the electric field strength of a moving arcing contact and an insulation cover, to increase slightly the electric field strength of a fixed arcing contact and to decrease consequently the dielectric recovery capability between poles of the interrupter.

  • PDF

Analysis for Force Distribution on Surface Between Busbar Contacts (부스바 접점 가동시 접촉면에서 압점력 해석)

  • Oh, Y.H.;Song, K.D.;Kim, K.S.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.82-84
    • /
    • 2003
  • In case contact between point of contacts is not achieved well, contact resistance is grown, and by current concentration at current conducting contacts can weld. In order to decrease contact resistance between contacts in case of busbar, installing spring between fixed contact and moving contact. and then force on faying surface of contacts increase and contact resistance decrease. But, in case increase force of spring to widen contact area, operating force moving contact can grow, on the contrary force of spring is small, contact resistance becomes low. Therefore, need to optimize force and number of spring. position, and also need to examine force change on contact surface at point of contact moving. In this paper, dynamic kinetics analysis for force on faying surface of contacts is performed at unsteady state. It is showed to not uniform force on surface between contacts, and we can got more uniform force by means of change spring position.

  • PDF

Trend of Telematics Terminal Technology (텔레매틱스 단말 기술 및 시장 동향)

  • Moon, Y.B.;Kim, M.J.;Kim, S.J.;Kwon, O.C.
    • Electronics and Telecommunications Trends
    • /
    • v.20 no.3 s.93
    • /
    • pp.3-9
    • /
    • 2005
  • 텔레매틱스 단말은 운전자와 차량, 차량과 차량 외부의 정보들과의 접점으로 관련 산업과의 컨버전스가 급속히 진행되고 있으며, 다양한 서비스에 대한 요구 역시 점차 증가하고 있다. 이에 따라 다양한 첨단 기술들이 단말에 도입되고 있다. 텔레매틱스 단말 기술은 서버로부터 다양한 통신 수단을 통해 가동되어 전달되는 각종 서비스 정보 및 응용 소프트웨어를 사용자에게 제공하기 위한 차량내 하드웨어 및 소프트웨어환경에 관련된 기술이다. 텔레매틱스 단말시장은 완성차량의 적용에 따라 비포마켓용과 애프터마켓용으로 나누어 출시되고 있으며, 텔레매틱스 시장의 기대감으로 인해 다양한 단말기와 대중화된 단말시장이 형성될 전망이다. 본 고에서는 이러한 차량내 텔레매틱스 서비스를 제공하기 위한 텔레매틱스 단말에 대한 국내외 단말기의 기능 및 업체 시장 동향과 텔레매틱스 단말에 적용되는 관련기술에 대하여 알아본다.

Opening Spring Modeling of Current Circuit Breaker Mechanism with respect to Opening Speed using Energy Method (전류 차단기 메커니즘에서 에너지방법을 이용한 차단 속도에 따른 스프링 모델링)

  • Kwon, Byung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.688-692
    • /
    • 2000
  • This study proposed design parameters of opening spring of circuit breaker that cut off the over-current in order to protect the electric device about opening speed using the energy method. We simulated the opening kinetic energy, the potential energy of opening spring and the design parameters of opening spring with respect to opening speed of VCB (Vacuum Circuit Breaker)'s moving contactor which has 24kV 25kA break capacity. From the result of simulation the initial tensional force and the final tensional force of the opening spring chose 107kgf and 282kgf respectively. Through the dynamic analysis using ADAMS, We verified that the opening speed of moving contactor satisfied break capacity of VCB and analyzed opening dynamic characteristics of VCB such as the opening displacement, the opening velocity and the opening acceleration of moving contactor in time domain.

  • PDF

Interruption Mechanism of the piston moving type GCB employed MDDM (MDDM을 적용한 피스톤 이동형 가스차단기의 차단동작특성)

  • Song, Ki-Dong;Chong, Jin-Kyo;Park, Kyeong-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1065-1067
    • /
    • 2005
  • 본 논문은 기존의 가스차단기와는 다른 차단동작을 가지는 새로운 형태의 가스차단기에 대한 특징을 검토한 것이다. 기존의 차단기에서 움직이던 가동부가 고정되고, 반대로 고정부이던 피스톤이 움직인다. 또한 기존 차단기의 고정부였던 고정 아크접점에 MDDM(Motor direct drive mechanism)을 채용하고, 반대편에 피스톤과 연결되는 소형 유압식 조작기를 설치함으로서 양방향 차단기(dual motion circuit breaker)를 구현하였다. 국내에서는 처음으로 MDDM을 실제 차단기에 적용한 사례로 판단되며, 기본 차단동자특성을 분석하여 향후 초고압 차단기에 적용할 수 있는 가능성을 검토하였다.

  • PDF