• 제목/요약/키워드: 가공지선

검색결과 74건 처리시간 0.026초

델타스폿용접을 이용한 이종소재 웰드본딩공정 시 표면 거칠기 부여 가공방법의 영향 (Effect of Surface Roughness on Weld-bonding Process using Heterogeneous Materials)

  • 김영현;김재웅;김지선;김영곤;표창민
    • 한국기계가공학회지
    • /
    • 제19권11호
    • /
    • pp.102-108
    • /
    • 2020
  • The demand for lightweight materials and high-strength steel has rapidly increased to help reduce the weight of a vehicle body; it improves the fuel efficiency of automobiles and provides passenger safety. Additionally, as the material becomes thinner, the demand for its resistance against corrosion becomes higher. Hence, the application of the surface-treated steel sheet has surged rapidly. In this study, a weld bonding experiment using a delta spot welding machine is performed on a thin sheet of a different material (Al6061-T6/GA440). The thickness of the material was kept at 1 mm to reduce the weight of the automobile body parts. Additionally, the purpose of this study is to control the heat input by applying the welding conditions of a multi-stage pressure pattern to improve corrosion resistance shear strength. The analysis of nugget diameter measurement, shear tensile test, and salt spray test was performed to achieve the aim.

혼합배전계통에서 뇌과전압 해석을 통한 중성선과 가공지선 혼용 운전의 타당성 평가 (Suitability Evaluation on Joint Operation of Neutral Wire and Overhead Grounding Wire through Lightning Surge Analysis in Combined Distribution System)

  • 정석산;이종범;김용갑;송일근;김병숙
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2135-2142
    • /
    • 2010
  • This paper studies the validity about a joint operation of neutral wire and overhead grounding wire in combined distribution systems. The overhead grounding wire and neutral wire are currently installed separately and grounded by common. However there is no any ineffectiveness or electrical problem in case of the proposed system, such system can be operated at real distribution system. Therefore this paper describes the suitability of a joint operation through lightning surge analysis on combined distribution systems. Lightning surge analysis is carried out by EMTP/ATPDraw to obtain the overvoltage of overhead line and underground cable in various conditions such as locations and current types of lightning stroke. Overvoltage gained by the analysis show that the insulation strength of the joint operation case is not stable compare with the current operation case.

감 탄닌 추출물의 열 발색공정에 의한 면직물 염색 (Coloration of Cotton Fabrics with Tannins of Persimmon Extracts by Heating Process)

  • 정종석;박지선;김태경
    • 한국염색가공학회지
    • /
    • 제20권3호
    • /
    • pp.25-30
    • /
    • 2008
  • In order to examine the availability of a heating process for persimmon dyeing, the cotton fabrics treated with various concentrations of persimmon extracts were heated at various temperatures and times. The raw and fermented persimmon extracts were used for the coloration. For both extracts, the color strength of fabrics was. increased with the increase of coloration temperature, time, and concentration of the extracts. Considering the practical aspects. and color strength, the temperature around $200^{\curc}C$ and the time longer than 60 minutes can be determined as the. optimum coloration conditions of persimmon extracts onto cotton fabrics. However, somewhat loss of strength by the hearing process seems to be inevitable. The color fastness to washing was excellent for both color change and staining showing a rating of 5.

혼합배전계통에서 뇌과전압 해석을 통한 중성선과 가공지선 혼용 운전시 적정 피뢰기 위치에 관한 연구 (A Study on the Optimal Position of Lightning Arrester on Joint Operation of Neutral Wire and Overhead Grounding Wire through Lightning Surge Analysis in Combined Distribution System)

  • 정석산;장화윤;안천용;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.535-536
    • /
    • 2011
  • This paper studies the validity about a joint operation of neutral wire and overhead grounding wire in combined distribution systems. The overhead grounding wire and neutral wire are currently installed separately and grounded by common. However there is no any ineffectiveness or electrical problem in case of the proposed system, such system can be operated at real distribution system. Therefore this paper describes the suitability of a joint operation through lightning surge analysis on combined distribution systems and analyzes the optimal position of lightning arrester on joint operation of neutral wire and overhead grounding wire. Lightning surge analysis is carried out by EMTP/ATPDraw to obtain the overvoltage of overhead line and underground cable in various conditions such as location and current types of lightning stroke. Over voltage gained by the analysis show that the insulation strength of the joint operation case is not stable compare with the current operation case.

  • PDF

국내 배전계통의 가공지선 접지조건에 따른 뇌서지 영향 분석 (Analysis of Effect on Lightning Surge according to the Grounding Condition of Overhead Ground Wire in Distribution System)

  • 한준;김철환;서훈철;최선규;이병성
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.331-337
    • /
    • 2014
  • The Korean distribution system consists of overhead ground wire (OHGW), phase conductors and neutral wire. Especially, OHGW is installed over the phase conductors to protect distribution system from the lightning surge. The flashover rate and the magnitude of lightning overvoltage on distribution system can be affected by grounding condition of OHGW such as grounding resistance and grounding interval. In this paper, we conduct an analysis of lightning overvoltage and flashover rate according to the grounding condition of OHGW. The distribution system and lightning surge are modeled by using ElectroMagnetic Transient Program (EMTP). Also, the Monte Carlo method is applied to consider random characteristics of lightning, and the flashover rate is calculated based on IEEE std. 1410. The simulations are performed by changing the grounding resistance and interval of OHGW and the simulation results are analyzed.

가공지선 전류 검출 방식의 송전선 사고 및 낙뢰 구간 검출 시스템 개발 (The Development of Fault and Lightning Stroke Section Location System for Overhead Transmission Line)

  • 이창영;김정년;오덕진;하체웅;김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.584-586
    • /
    • 2004
  • This paper deals with the development of on-line fault and lightning stroke section locating system for branched overhead transmission line. The section locating algorithm of this system i3 by analyzing the distribution pattern of current flowing through the overhead ground wire. It composes of three parts; current sensors, local remote terminal unit(RTU) and analysis program at surveillance tenter. Double Rogowski coil sensor having integrating amplifier was designed as current sensor. In order for current pattern analysis, the transmitted waves from each sensor wert synchronized by GPS tim c clock in RTU. While, lightning stroke location are judged only by polarity information of lightning currents. This design has a benefit in simplicity of signal processing unit of RTU.

  • PDF

소형전기청소차(Small E-Sweeper) 프레임의 실험 및 수치해석을 통한 구조강도 연구 (An Experimental and Numerical Investigation of the Structural Durability of Vehicle Frames in Small Electric Sweepers)

  • 조규춘;이지선;신행우;장명균;유직수;정민관
    • 한국기계가공학회지
    • /
    • 제20권1호
    • /
    • pp.116-124
    • /
    • 2021
  • In this study, the reliability of vehicle frames employed in small electric road sweepers was assessed through durability testing. The frames were tested under three conditions, whereby mechanical loads were applied to (1) the entire frame, (2) the front frame, and (3) the rear frame. The strain distributions in the loaded frames were determined through a combination of direct strain gauge measurements and supplementary numerical analysis. While subtle differences were observed between the experimental and numerical analyses, both methods successfully yielded comparable deformation patterns. Thus, the dependence of stress distribution and the state of the frame on loading conditions could be fully identified through our combined structural and numerical analysis.

Bidirectional GRU-GRU CRF 기반 참고문헌 메타데이터 인식 (Bidirectional GRU-GRU CRF based Citation Metadata Recognition)

  • 김선우;지선영;설재욱;정희석;최성필
    • 한국정보과학회 언어공학연구회:학술대회논문집(한글 및 한국어 정보처리)
    • /
    • 한국정보과학회언어공학연구회 2018년도 제30회 한글 및 한국어 정보처리 학술대회
    • /
    • pp.461-464
    • /
    • 2018
  • 최근 학술문헌이 급격하게 증가함에 따라, 학술문헌간의 연결성 및 메타데이터 추출 등의 핵심 자원으로서 활용할 수 있는 참고문헌에 대한 활용 연구가 진행되고 있다. 본 연구에서는 국내 학술지의 참고문헌이 가진 각 메타데이터를 자동적으로 인식하여 추출할 수 있는 참고문헌 메타데이터 인식에 대하여, 연속적 레이블링 방법론을 기반으로 접근한다. 심층학습 기술 중 연속적 레이블링에 우수한 성능을 보이고 있는 Bidirectional GRU-GRU CRF 모델을 기반으로 참고문헌 메타데이터 인식에 적용하였으며, 2010년 이후의 10종의 학술지내의 144,786건의 논문을 활용하여 추출한 169,668건의 참고문헌을 가공하여 실험하였다. 실험 결과, 실험집합에 대하여 F1 점수 97.21%의 우수한 성능을 보였다.

  • PDF

MSR을 이용한 용접잔류응력의 제거와 적용성 검토 (Mechanical Stress Relief Technology and its Application)

  • 박지선;한명수;한종만
    • Journal of Welding and Joining
    • /
    • 제15권3호
    • /
    • pp.29-35
    • /
    • 1997
  • 실제로 용접구조물의 재료에는 항상 내부 잔류응력이 존재하며 그 크기는 재료내의 내부 잔류응력간의 평형의 원리(Self-equilibrating system)에 의해 결정 된다. 일반적인 구조 강도설계에서 행해지는 탄성해석에서는 재료 내부에 존재하는 잔류응력을 고려하지 않기 때문에 설계시에 계산된 응력이 심하중하의 구조물에서 발생하는 응력과 같다고 볼 수는 없다. 철강재료를 사용한 구조물의 경우 구조물 제작 공정 전반에 걸친 성형가공 및 조립과정에 수반되어 재료 내에는 잔류응력이 발생되며 특히 용접조립에 의해 용접부 근방에서는 재료의 항복강도 수준의 상당히 큰 용접응력 이 발생하게 된다. 일반적으로 용접잔류응력의 완화법으로 가장 확실한 방법은 후열 처리법(Post weld heat treatment, PWHT)이지만 이 방법의 적용은 구조물의 크기에 제한을 받게 된다. 따라서 PWHT를 적용하기 어려운 구조물에 대해서는 다른 방법에 의해 용접잔류 응력을 완화시켜야 하며 이 경우에 일반적인 방법으로 기계적 응력완화 법(Mechanical stress relief method, MSR)이 있다. 본고에서는 MSR의 기본원리에 대하여 간단하게 정리하고 실 구조물에 대한 MSR 적용시 고려해야 할 제반사항을 위하여 단순 용접부에 대한 MSR 적용 실험결과와 실제 압력용기를 대상으로 MSR을 자체 제작된 기술절차서에 따라서 시행하고 MSR의 적용성에 대해서 검토하였다.

  • PDF

배전선로 1선 지락고장시 고장전류의 대지유입률 검토 (Study on the Fault Current Division Factor in Multi-grounded Distribution System)

  • 강문호;임용훈;최종기;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.671-672
    • /
    • 2007
  • 국내 배전선로는 다중으로 중성선을 접지하여 운영하고 있어 지락고장이 발생하면 큰 고장전류가 발생하며, 이는 중성선 및 가공 지선과 접지극으로 분류되어 전원측으로 귀로한다. 유도전력기술기준에서는 이 분류율을 배전선로의 경우 50%로 규정하고 있어 배전선로 신 증설시 통신선과의 이격거리 확보에 어려움이 발생하고 있다. 따라서 본 논문에서는 국내 배전선로의 1선 지락전류의 분류율을 기술적으로 검토하기 위해 배전선로 설계기준을 바탕으로 1선 지락고장전류의 대지유입률을 모의하고 그 결과를 분석하였다.

  • PDF