Lee, Minseog;Baek, Seungdong;Sung, Taehong;Kim, Hyun Dong;Chae, Jung Min;Cho, Young Ah;Kim, Hyoungtae;Kim, Kyung Chun
Journal of the Korean Institute of Gas
/
v.20
no.6
/
pp.65-72
/
2016
ORC system was designed and constructed for utilizing the heat of the exhaust gas and coolant released from the gas engine which was modified to use natural gas as a fuel. In this paper the components of the ORC system were designed and manufactured based on measured data of the gas engine. The components are composed of two plate heat exchanger, the 5kW-class expander and multi stage centrifugal pump. The thermodynamic performance of the ORC system was analyzed by using the electric heater. Also, the developed ORC system was implemented to modified natural gas engine. Two gas engines were used to supply heat to the ORC system. As a result of test bench, when the heat source temperature is $110^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 5.22kW, 7.41, 9.09%. As a result of field test, when the heat source temperature is $86^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 2kW, 3.75, 6.45%.
Coating pipe(PLP) has been generally used in buried site for protecting the corrosion. To prevent the damage by occurring the defect, other construction or execution works, an anti-oxidation environment was forcibly made by using protective potential. Coating and protective potential are applied simultaneously, but corrosion rate or defects are not easy to observe because soil composition has many uncertainty. Also, defect of coating pipe can not be directly observed. A corrosion coupon can easily measure a corrosion rate directly. The corrosion rate was measured with 6 scenarios using corrosion coupon during about 1 year(6 scenarios are based on soil type and protective potential or not in this research. Resultingly, the corrosion coupon has not occurred in the case of protected by potential current, but corrosion has occurred in a non-protected site. The corrosion rate was measured at least in the clay, and the propensity of corrosion rate was similar in other soil(sand and loams). The local corrosion has occurred in the clay because of high water content. On the other hand, general corrosion was occurred in sand and loams. Commonly, sand is not to corrosive soil. Although, corrosion occurred in sand can be estimated by chemical component and valid with chemical analysis report.
Jo, Jae-Hyun;Lee, Sang-Yong;Lee, Geun-Yong;Yoon, Se-Jin;Cheong, Ha-Young;Lee, Sang-Sik
The Journal of Korea Institute of Information, Electronics, and Communication Technology
/
v.13
no.3
/
pp.212-218
/
2020
When Radiofrequency energy is applied to the human body, the vibration width is very short. Therefore, the electrolyte burn generated when using the direct current does not occur. Ion molecules, polarized molecules, etc., vibrate more than 40,000 times per second, converting them into frictional heat to generate deep heat. The blood flow of capillaries increases 4-5 times more than at rest, increasing the supply of oxygen, nutrients, antibodies, and white blood cells. In addition, the electrochemical reaction does not occur because the vibration width and the pulsation period are very short. It is a physical factor treatment method that does not stimulate the sensory nerves and motor nerves. In this study, an isotonic exercise is performed in a young normal adult using a Radiofrequency pain treatment device. The purpose of this study is to integrate rehabilitation therapy by measuring electromyography data during isotonic exercise and confirming the effect on changes in motor neuron response. The EMG data generated when isotonic exercise of the forearm biceps muscle and the EMG data measured after the use of a Radiofrequency pain treatment device after exercise were RMS, respectively, and verified through t-test. It was confirmed that there was a significant difference in both men and women because the t-value was smaller than the significance level p (<.05).
Park, Hwa-sun;Na, Youngil;Choi, Ho Joon;Suh, Su-jeong;Baek, Dong-Hyun;Yoon, Jung-Rag
Journal of Electrical Engineering and Technology
/
v.13
no.4
/
pp.1638-1643
/
2018
Multi-layer ceramic capacitors as decoupling capacitor were fabricated by dielectric composition with a high dielectric constant. The fabricated decoupling capacitors were embedded in the PCB of the 10G RF transceiver module and evaluated for the characteristics of electrical noise by the level of AC input voltage. In order to further improve the electrical properties of the $BaTiO_3$ based composite, glass frit, MgO, $Y_2O_3$, $Mn_3O$, $V_2O_5$, $BaCO_3$, $SiO_2$, and $Al_2O_3$ were used as additives. The electrical properties of the composites were determined by various amounts of additives and optimum sintering temperature. As a result of the optimized composite, it was possible to obtain a density of $5.77g/cm^3$, a dielectric constant of 1994, and an insulation resistance of $2.91{\times}10^{12}{\Omega}$ at an additive content of 5wt% and a sintering temperature of $1250^{\circ}C$. After forming a $2.5{\mu}m$ green sheet using the doctor blade method, a total of 77 layers were laminated and sintered at $1180^{\circ}C$. A decoupling capacitor with a size of $0.6mm(W){\times}0.3mm(L){\times}0.3mm(T)$ (width, length and thickness, respectively) and a capacitance of 100 nF was embedded using a PCB process for the 10G RF Transceiver modules. In the range of AC input voltage 400mmV @ 500kHz to 2200mV @ 900kHz, the embedded 10G RF Transceiver modules evaluated that it has better electrical performance than the non-embedded modules.
Journal of the Korean Institute of Landscape Architecture
/
v.41
no.4
/
pp.17-23
/
2013
The purpose of this study was to provide information on management and apply it to a roadside ground cover plant understanding the capacity of calcium chloride in the plant. The experimental group was composed of the ratio control group of calcium chloride, 0.5%, 1.0%, and 3.0% in 500g of soil. Plant materials were selected and measured according to their ecological characteristics such as ground cover plant, Pachysandra terminalis, Hosta plantaginea, Trachelospermum asiaticum, Vitex rotundifolia, Euonymus japonica and Callicarpa japonica. The acidity of the amended soil was increased gradually depending on the treatment and conductivity was continually decreased. The EX-Ca increased after the treatment, but decreased in the middle of the experiment. Pachysandra terminalis, Trachelospermum asiaticum and Euonymus japonica were able to grow and survive at the ratio of 0.5%. Hosta plantaginea and Vitex rotundifolia were able to survive at the ratio of 1.0%. Hosta plantaginea, the possible state can absorb salts due to moisture and, can be applied to ground cover plants in the roadside. The growth and development of Callicarpa japonica was poor and the leaves were open to grow for calcium chloride treatment except the control group. It was concluded that Callicarpa japonica was very sensitive to calcium chloride.
Oh, Seungbin;Jang, Jun-Hyuk;Park, Jin Hyoung;Kim, Hongtae
Journal of Navigation and Port Research
/
v.37
no.4
/
pp.401-407
/
2013
In parallel with the development of ship equipment, bridge systems have been improved, but marine accidents due to human error have not been reduced. Recently, research in nautical bridge equipment has focused on suitable ergonomic designs in order to reduce these errors due to human factors. In a bridge of a ship, there are numerous auditory signals that deliver important information clearly to the sailors. However, only a few studies have been conducted related to the human recognition of these auditory signals. There are three types of auditory signals: voice alarms, abstract sounds, and auditory icons. This study was conducted in order to design more appropriate auditory icons using a sensibility evaluation method. The auditory icons were rated to have five warning situations (engine failure, fire, steering failure, low power, and collision) using the Semantic Differential Method. It is expected that the results of this study will be used as basic data for auditory displays inside bridges and for integrated bridge alarm systems.
Journal of the Korea Institute of Information and Communication Engineering
/
v.21
no.2
/
pp.379-385
/
2017
In general, distribution board, panel board and motor control center can be installed over a wide area such as residence of group, building, schools, factories, ports, airports, water service and sewerage, substation and heavy industries that are used to supply converts the voltages extra high voltage into optimal voltage. There are electrical accidents due to rise of contact temperature, loose contact between busbar, deterioration of the contact resistance, over temperature of the busbars. In this paper, we designed and implemented the busbar joint and temperature measurement system, which can measure the joint resistance of busbar and loose connection between busbar using potentiometer and non-contact infrared sensor. The experimental results show that tightening the bolt and nut is fully engaged, resistance was decreased and maximum error range was 0.1mm. Also, the experimental result showed that the temperature at the contact area is increased from $27.3^{\circ}C$ to $69.3^{\circ}C$by the contact resistance.
Journal of the Korea Academia-Industrial cooperation Society
/
v.3
no.1
/
pp.49-57
/
2002
The possibility of a transmission noise reduction of piezoelectric smart panels using piezoelectric shunt damping is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing materials are bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to reduce the sound transmission at low panel resonances, piezoelectric damping using the measured electrical impedance model is adopted. Resonant shunt circuit for piezoelectric shunt damping is composed of register and inductor in series, and they are determined by maximizing the dissipated energy throughout the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a tube with square crosses section and a loud-speaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across panels is measured. Noise reduction performance of a smart panels possessing absorbing material and/or air gap shows a good result at mid frequency region but little effect in the resonance frequency. By enabling the piezoelectric shunt damping, noise reduction of 10dB, 8dB is achieved at the resonance frequencise as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.
Journal of the Korea Academia-Industrial cooperation Society
/
v.17
no.1
/
pp.9-14
/
2016
This study evaluated a digital locking device design using detection distance of 13.4mm of a human body sensing type magnetic field coil. In contrast to digital locking devices that are used nowadays, the existing serial number entering buttons, lighting, number cover, corresponding pcb, exterior case, and data delivery cables have been deleted and are only composed of control ON/OFF power switches and emergency terminals. When the magnetic field coil substrates installed inside the inner case detects the electric resistance delivered from the opposite side of the 12mm interval exterior contacting the glass body part, the corresponding induced current flows. At this time, the magnetic field coil takes the role as a sensor when coil frequency of the circular coil is transformed. The magnetic coil as a sensor detects a change in the oscillation frequency output before and after the body is detected. This is then amplified to larger than 2,000%, transformed into digital signals, and delivered to exclusive software to compare and search for embedded data. The detection time followed by the touch area of the body standard to a $12.8{\emptyset}$ magnetic field coil was 30% contrast at 0.08sec and 80% contrast at 0.03sec, in which the detection distance was 13.4mm, showing the best level.
Proceedings of the Korean Institute of Surface Engineering Conference
/
1998.05a
/
pp.108-108
/
1998
일반적으로 탄소강은 수용액 중에 노출될 경우 전면부식에 의한 손상을 받는다. 그러나 부식방지를 위하여 부식억제제를 적용할 경우, 탄소강의 부식거동은 현저한 변화를 겪게된다. 이러한 부식거동의 변화는 첨가되는 부식억제제의 종류에 따라 분 류할 수가 있는데, 양극부식억제제, 음극부식억제제 그리고 이들의 혼합부식억제제로 분류할 수가 있다. 현장에 적용된 부식억제제 시스템 중에는 자동차용 부동액과 가스히터용 열전달 매체액이 있다. 이러한 부식억제제가 적용된 시스댐은 정확한 부식억제능의 평가에 의한 그 교체 시기의 결정이 매우 중요하다. 교체 시기가 빠를 경우, 유지비용이 과다하게 소요되는 문제가 있으며, 교체시기가 늦을 경우 설비의 부식을 초래하는 문제 가 있다. 따라서 부식억제제의 정확한 성능 평가법은 매우 중요하며, 이에 대한 다양 한 연구가 진행 중이다. 부식억제제가 함유된 용액의 부식억제성능을 평가하는 방법에는 대표적으로 무게 감량법을 이용하고 있다. 이 방법은 다종의 금속이 적용된 자동차용 부동액을 실제 사용조건과 유사한 실험 조건에서 단기간, 가혹조건에서의 무게 감량에 의해 부식억 제능을 평가하는 방법이다. 그러나 이러한 방법은 특히 국부부식이 진행될 경우 부 식억제능을 정량화 하는데 어려움이 있다. 한편 전기화학적 측정방법으로는 분극곡선법을 이용한 $E_P$(공식개시전위), $E_R$(재부동태 화전위)의 측정법이 있다. 또한 부식억제피막의 안정성을 측정하기 위한 방법으로 인 위적인 양극전류 인가에 의한 피막의 파괴후에 피막이 복원가능 여부 및 그 속도 측 정에 의해 부식억제제의 건전성을 확인할 수가 었다. 본 연구에서는 가스히터의 주구성 재료인 A210 Gr Al의 탄소강을 사용하여, 사용기간이 5년 이상되어 부식억제 기능을 거의 상실한 것으로 여겨지는 열전달 매체액 과 신규 부식억제제가 적용된 시스템 등 객관적으로 확인된 부식억제제 시스랩에 대 하여 다양한 평가 방법을 동원 비교분석하고자 하였다. 실험은 KSM 2142에 의한 무게감량법, 분극곡선 측정에 의한 $E_P$(공식개시전위), $E_R$(재부동태화전위) 측정, 시간에 따른 자연전위 변화 측정 빛 이때의 부식속도(선형분극법), 인위적인 피막 파괴 전,후 의 전위 변화 및 부식속도 측정법에 의한 국부부식 발달 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.