• Title/Summary/Keyword: ^{15}O-PET$

Search Result 66, Processing Time 0.02 seconds

Principle and Recent Advances of Neuroactivation Study (신경 활성화 연구의 원리와 최근 동향)

  • Kang, Eun-Joo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.2
    • /
    • pp.172-180
    • /
    • 2007
  • Among the nuclear medicine imaging methods available today, $H_2^{15}O-PET$ is most widely used by cognitive neuroscientists to examine regional brain function via the measurement of regional cerebral blood flow (rCBF). The short half-life of the radioactively labeled probe, $^{15}O$, often allows repeated measures from the same subjects in many different task conditions. $H_2^{15}O-$ PET, however, has technical limitations relative to other methods of functional neuroimaging, e.g., fMRI, including relatively poor time and spatial resolutions, and, frequently, insufficient statistical power for analysis of individual subjects. However, recent technical developments, such as the 3-D acquisition method provide relatively good image quality with a smaller radioactive dosage, which in turn results in more PET scans from each individual, thus providing sufficient statistical power for the analysis of individual subject's data. Furthermore, the noise free scanner environment $H_2^{15}O$ PET, along with discrete acquisition of data for each task condition, are important advantages of PET over other functional imaging methods regarding studying state-dependent changes in brain activity. This review presents both the limitations and advantages of $^{15}O-PET$, and outlines the design of efficient PET protocols, using examples of recent PET studies both in the normal healthy population, and in the clinical population.

The Decomposition Kinetics of PET Microfiber Fabrics by Saturated CaO/Ethylene glycol Solution (CaO/Ethylene glycol 용액에 의한 Polyester섬유의 분해에 관한 연구)

  • Yoon, Jong Ho;Huh, Man Woo;Kim, Kyung Jae
    • Textile Coloration and Finishing
    • /
    • v.9 no.3
    • /
    • pp.18-26
    • /
    • 1997
  • Polyester microfiber fabrics were decomposed at 100, 110, and 12$0^{\circ}C$ in saturated CaO/ethylene glycol solutions(CaO/EG), and the characteristics of decomposition kinetics were discussed in comparison to those by hot aqueous hydroxide solution(NaOH). The Arrhenius pre-exponential factor(A) was 9.17x $10^{14}$/M $sec^{-1}$and the activation energy($E_{a}$) was 8.19kcal/mol. While the A value was 1.947x $10^{14}$/M $sec^{-1}$ and the ($E_{a}$ value was about 15~19kcal/mol in NaOH-PET decomposition reaction. The much higher A value of the CaO/EG-PET decomposition reaction means that CaO/EG-PET decomposition reaction will occur in a less selective fashion in comparison to the NaOH-PET decomposition reaction. On the other hand, the lower ($E_{a}$) value of the CaO/EG-PET decomposition reaction than that of the NaOH-PET decomposition reaction means that CaO/EG-PET decomposition reaction is less sensitive on the variation of temperature than NaOH-PET decomposition reaction.

  • PDF

Recovery of Polyethylene Telephthalate Monomer over Cu or Mn/γ-Al2O3 Catalysts (Cu, Mn/γ-Al2O3 촉매상에서 polyethylene telephthalate 단량체의 회수 연구)

  • Sim, Jae-Wook;Kim, Seung-Soo
    • Applied Chemistry for Engineering
    • /
    • v.28 no.4
    • /
    • pp.485-489
    • /
    • 2017
  • Polyethylene terephthalate (PET) has been widely applied in polymers and packaging industries to produce synthetic fibers, films, drink bottles or food containers. Therefore, it has become one of the major plastic wastes. In this article, glycolysis known as one of the main methods in PET chemical recycling was investigated using a glycol to break down the polymer into a monomer. Glycolysis of PET and ethylene glycol was performed in a micro-tubing reactor under various conditions. The effect of glycolysis conditions on the product distribution was investigated at experimental conditions of the EG/PET ratio of 1~4, the reaction time of 15~90 min and the reaction temperature of $250{\sim}325^{\circ}C$ with Mn and Cu catalysts. The highest yield of bis (2-hydroxyethyl) terephthalate monomer (BHET) was obtained as 89.46 wt% under the condition of the reaction temperature of $300^{\circ}C$ and the time of 30 min using 10 wt% $Cu/{\gamma}-Al_2O_3$ catalyst, with the PET and ethylene glycol ratio of 1 : 2.

Functional Mapping of the Neural Basis for the Encoding and Retrieval of Human Episodic Memory Using ${H_2}^{15}O$ PET ({H_2}^{15}O$ PET을 이용한 정상인의 삽화기억 부호화 및 인출 중추 뇌기능지도화)

  • Lee, Jae-Sung;Nam, Hyun-Woo;Lee, Dong-Soo;Lee, Sang-Kun;Jang, Myoung-Jin;Ahn, Ji-Young;Park, Kwang-Suk;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.10-21
    • /
    • 2000
  • Purpose: Episodic memory is described as an 'autobiographical' memory responsible for storing a record of the events in our lives. We performed functional brain activation study using ${H_2}^{15}O$ PET to reveal the neural basis of the encoding and the retrieval of episodic memory in human normal volunteers. Materials and Methods: Four repeated ${H_2}^{15}O$ PET scans with two reference and two activation tasks were performed on 6 normal volunteers to activate brain areas engaged in encoding and retrieval with verbal materials. Images from the same subject were spatially registered and normalized using linear and nonlinear transformation. Using the means and variances for every condition which were adjusted with analysis of covariance, t-statistic analysis were performed voxel-wise. Results: Encoding of episodic memory activated the opercular and triangular parts of left inferior frontal gyrus, right prefrontal cortex, medial frontal area, cingulate gyrus, posterior middle and inferior temporal gyri, and cerebellum, and both primary visual and visual association areas. Retrieval of episodic memory activated the triangular part of left inferior frontal gyrus and inferior temporal gyrus, right prefrontal cortex and medial temporal area, and both cerebellum and primary visual and visual association areas. The activations in the opercular part of left inferior frontal gyrus and the right prefrontal cortex meant the essential role of these areas in the encoding and retrieval of episodic memory. Conclusion: We could localize the neural basis of the encoding and retrieval of episodic memory using ${H_2}^{15}O$ PET, which was partly consistent with the hypothesis of hemispheric encoding/retrieval asymmetry.

  • PDF

유연성 소자 적용을 위한 $SiO_x$ 보호막의 특성 평가

  • Jeong, Yu-Jeong;Jeong, Jae-Hye;Yun, Jeong-Heum;Lee, Seong-Hun;Lee, Geon-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.452-452
    • /
    • 2010
  • 차세대 디스플레이로서 주목 받고 있는 유연성 정보표시 소자 개발에 대한 요구도가 날로 증대되고 있다. 유연성 정보표시 소자로서 플라스틱 기반 유연성 소자가 특히 주목 받고 있으나, 이의 실용화를 위해서는 플라스틱 기판에 적용 가능한 보호막 형성 기술 개발이 선행되어야 한다. 플라스틱 필름의 경우 높은 산소 및 수분 투과율 때문에 유연성 디스플레이의 응용에 걸림돌이 되고 있다. 플라스틱 기반 유연성 소자의 장수명화를 위해서는 수분과 산소의 투과를 방지하는 passivation layer 형성 기술이 필수적으로 요구된다. 본 연구에서는, polyethylene terephethalate (PET) 기판상에 증착된 $SiO_x$ 보호막의 합성에 있어서 중간층 유무에 따른 투습특성의 변화를 살펴보았다. 기화된 HMDSO (Hexamethyldisiloxane)와 Ar 및 $O_2$ 혼합기체를 이용하여 PECVD 방법으로 $SiO_x$ 박막을 합성하였다. 15 nm 두께의 $Al_2O_3$를 중간층으로 사용하여 중간층 유무에 따른 초기성장 거동 변화가 $SiO_x$ 박막의 투습 특성에 미치는 영향을 조사하였다. $SiO_x$ 박막 구조와 화학적 조성은 각각 FE-SEM과 FT-IR을 이용하여 분석하였으며, AFM을 이용하여 $SiO_x$ 박막 표면 미세 형상을 관찰하였다. 투습률은 MOCON사(社)의 Permatran-W 3/33 MA을 이용하여 측정하였다. 그리고 반복 굽힘 시험기를 이용하여 $SiO_x$ 보호막의 동적 투습 특성을 조사하였다. $Al_2O_3$ 중간층 유무에 따라 $SiO_x$ 박막의 투습률 (WVTR; water vapor transmission rate)은 ${\sim}10^{-1}g/m^2/day$(300 nm-thick $SiO_x$/PET)에서 ${\sim}5{\times}10^{-3}g/m^2/day$(300 nm-thick $SiO_x$/15 nm-thick $Al_2O_3$/PET)으로 변화하였다. 300 nm-thick $SiO_x$/15 nm-thick $Al_2O_3$/PET 시편의 경우 곡지름 50 mm에서 1,000회 반복 굽힘 후에도 투습률 변화를 보이지 않았다. 이와 같은 $SiO_x$ 박막의 투습 특성 변화는 $Al_2O_3$ 중간층 유무에 따른 초기 성장 거동의 변화로 해석된다. FE-SEM 및 AFM 표면 미세 구조 관찰을 통한 초기 성장 거동 변화 조사 결과, $Al_2O_3$ 중간층 없이 PET 기판위에 $SiO_x$ 박막 증착한 경우 3 차원 성장을 하는 반면, PET기판위에 $Al_2O_3$ 중간층 형성 후 $SiO_x$ 박막 증착하는 경우 2 차원 성장을 하게 됨을 관찰하였다. 따라서 본 연구를 통하여, 플라스틱 기반 유연성 표시 소자에 적용하기 위한 $SiO_x$ 보호막 합성 에 있어서 초기 성장 거동의 변화가 투습 특성에 민감한 영향을 미침을 알 수 있었다.

  • PDF

Development of Quantification Methods for the Myocardial Blood Flow Using Ensemble Independent Component Analysis for Dynamic $H_2^{15}O$ PET (동적 $H_2^{15}O$ PET에서 앙상블 독립성분분석법을 이용한 심근 혈류 정량화 방법 개발)

  • Lee, Byeong-Il;Lee, Jae-Sung;Lee, Dong-Soo;Kang, Won-Jun;Lee, Jong-Jin;Kim, Soo-Jin;Choi, Seung-Jin;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.486-491
    • /
    • 2004
  • Purpose: factor analysis and independent component analysis (ICA) has been used for handling dynamic image sequences. Theoretical advantages of a newly suggested ICA method, ensemble ICA, leaded us to consider applying this method to the analysis of dynamic myocardial $H_2^{15}O$ PET data. In this study, we quantified patients' blood flow using the ensemble ICA method. Materials and Methods: Twenty subjects underwent $H_2^{15}O$ PET scans using ECAT EXACT 47 scanner and myocardial perfusion SPECT using Vertex scanner. After transmission scanning, dynamic emission scans were initiated simultaneously with the injection of $555{\sim}740$ MBq $H_2^{15}O$. Hidden independent components can be extracted from the observed mixed data (PET image) by means of ICA algorithms. Ensemble learning is a variational Bayesian method that provides an analytical approximation to the parameter posterior using a tractable distribution. Variational approximation forms a lower bound on the ensemble likelihood and the maximization of the lower bound is achieved through minimizing the Kullback-Leibler divergence between the true posterior and the variational posterior. In this study, posterior pdf was approximated by a rectified Gaussian distribution to incorporate non-negativity constraint, which is suitable to dynamic images in nuclear medicine. Blood flow was measured in 9 regions - apex, four areas in mid wall, and four areas in base wall. Myocardial perfusion SPECT score and angiography results were compared with the regional blood flow. Results: Major cardiac components were separated successfully by the ensemble ICA method and blood flow could be estimated in 15 among 20 patients. Mean myocardial blood flow was $1.2{\pm}0.40$ ml/min/g in rest, $1.85{\pm}1.12$ ml/min/g in stress state. Blood flow values obtained by an operator in two different occasion were highly correlated (r=0.99). In myocardium component image, the image contrast between left ventricle and myocardium was 1:2.7 in average. Perfusion reserve was significantly different between the regions with and without stenosis detected by the coronary angiography (P<0.01). In 66 segment with stenosis confirmed by angiography, the segments with reversible perfusion decrease in perfusion SPECT showed lower perfusion reserve values in $H_2^{15}O$ PET. Conclusions: Myocardial blood flow could be estimated using an ICA method with ensemble learning. We suggest that the ensemble ICA incorporating non-negative constraint is a feasible method to handle dynamic image sequence obtained by the nuclear medicine techniques.

Evaluation of Endothelium-dependent Myocardial Perfusion Reserve in Healthy Smokers; Cold Pressor Test using $H_2^{15}O\;PET$ (흡연자에서 관상동맥 내피세포 의존성 심근 혈류 예비능: $H_2^{15}O\;PET$ 찬물자극 검사에 의한 평가)

  • Hwang, Kyung-Hoon;Lee, Dong-Soo;Lee, Byeong-Il;Lee, Jae-Sung;Lee, Ho-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • Purpose: Much evidence suggests long-term cigarette smoking alters coronary vascular endothelial response. On this study, we applied nonnegative matrix factorization (NMF), an unsupervised learning algorithm, to CO-less $H_2^{15}O-PET$ to investigate coronary endothelial dysfunction caused by smoking noninvasively. Materials and methods: This study enrolled eighteen young male volunteers consisting of 9 smokers $(23.8{\pm}1.1\;yr;\;6.5{\pm}2.5$ pack-years) and 9 nonsmokers $(23.8{\pm}2.9 yr)$. They do not have any cardiovascular risk factor or disease history. Myocardial $H_2^{15}O-PET$ was performed at rest, during cold ($5^{\circ}C$) pressor stimulation and during adenosine infusion. Left ventricular blood pool and myocardium were segmented on dynamic PET data by NMF method. Myocardial blood flow (MBF) was calculated from input and tissue functions by a single compartmental model with correction of partial volume and spillover effects. Results: There were no significant difference in resting MBF between the two groups (Smokers: 1.43 0.41 ml/g/min and non-smokers: $1.37{\pm}0.41$ ml/g/min p=NS). during cold pressor stimulation, MBF in smokers was significantly lower than 4hat in non-smokers ($1.25{\pm}0.34$ ml/g/min vs $1.59{\pm}0.29$ ml/gmin; p=0.019). The difference in the ratio of cold pressor MBF to resting MBF between the two groups was also significant (p=0.024; $90{\pm}24%$ in smokers and $122{\pm}28%$ in non-smokers.). During adenosine infusion, however, hyperemic MBF did not differ significantly between smokers and non-smokers ($5.81{\pm}1.99$ ml/g/min vs $5.11{\pm}1.31$ ml/g/min ; p=NS). Conclusion: in smokers, MBF during cold pressor stimulation was significantly lower compared wi4h nonsmokers, reflecting smoking-Induced endothelial dysfunction. However, there was no significant difference in MBF during adenosine-induced hyperemia between the two groups.

Recent Status of Commercial PET Cyclotron and KOTRON-13 (KOTRON-13과 상용 PET 사이클로트론의 최근 기술 동향)

  • Chai, Jong-Seo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • This paper is described on the development of KOTRON-13 and recent status of PET cyclotron by commercial cyclotron companies. KIRAMS has developed medical cyclotron which is KIRAMS-13. Samyoung Unitech produces KOTRON-13 with transfered technology by KIRAMS. As a part of Regional Cyclotron Installation Protect, KOTRON-13 cyclotrons and $[18F]FDG$ production modules are being installed at regional cyclotron centers in Korea. The medical concern with radiation technology has been growing for the last several years. Early cancer diagnosis through the cyclotron and PET-CT have been brought to public attention by commercial cyclotron models in the world. The new commercial cyclotron models are introduced compact low energy cyclotrons developed by CTI, GE, Sumitomo in recent. It produces different short-lived radioisotopes, such as $[^{18}F],\;[^{11}C],\;[^{13}N]\;and\;[^{15}O]$. For the better reliability acceleration particle is proton only. The characteristics of new model cyclotrons are changed to lower energy corresponding to less 13 MeV. New models have self-shielding and low power consumption. Design criteria for the different types of commercial cyclotrons are described with reference to hospital demands.

Effects of $TiO_2$ content, fiber strength and spinning oil on dyeing properties of the PET fibers (PET원사의 염착특성과 관련한 $TiO_2$ 함량, 원사의 강도 및 방사유제의 영향)

  • Park Young-Min;Cho Dae-Hwan;Son Young-A
    • Textile Coloration and Finishing
    • /
    • v.18 no.3 s.88
    • /
    • pp.10-15
    • /
    • 2006
  • In this research, we studied the dyeing properties of PET fibers in terms of $TiO_2$ contents, fiber strength and spinning oil which may cause barre' effect. The effect of $TiO_2$ contents in the fibers had no influence on the dye uptake. However, the reflectance(%) behaviors showed the different visual properties as $TiO_2$ contents in the fibers. The other factors could be considered as strength and spinning oil which also revealed difference on the dye exhaustion. The experimental results showed that $TiO_2$ contents within the fibers influenced reflectance(%) behaviors. Furthermore, fiber strength and spinning oil could be considered other major factors to impart the dyeing irregularity and barre' effect.