• Title/Summary/Keyword: [BQ]

Search Result 448, Processing Time 0.024 seconds

A study to reduce the intestinal transport of endosulfan by indole (인돌을 이용한 잔류성 농약 endosulfan의 소장 흡수 억제 연구)

  • Gong, Daecheol;Kim, Juyeon;Choi, Hansol;Noh, Sang Kyu
    • Food Science and Preservation
    • /
    • v.21 no.1
    • /
    • pp.91-96
    • /
    • 2014
  • Evidence suggests that dietary indole, particularly rich in cruciferous vegetables, may reduce the risk of cardiovascular diseases. Endosulfan is a residual organochlorine pesticide, which is detected in fruits, vegetables, and crops. In this study, we investigated the effect of luminal indole on endosulfan transport in the small intestine in mesenteric lymph duct-cannulated rats. The duodenum was also cannulated and a fasting phosphate buffered saline-glucose solution was infused overnight at 3 mL/hr. After recovery, a lipid emulsion containing [2,3-$^{14}C$] endosulfan ($^{14}C$-endosulfan) was infused into the duodenum for 8 hours. The tested rats were infused with the same lipid emulsion, but with indole. Samples from the lymph-fistula were collected hourly, and the luminal contents and mucosa were collected at the end of the infusion. The lymph flow in the mesenteric lymph did not differ between the two groups. However, the intestinal absorption of both endosulfan and cholesterol were significantly decreased by indole. The amount of radioactive endosulfan, which remained in the mucosa, was greater in the indole-infused rats due to the decreased transport of endosulfan into the lymph. This study indicates that the indole decreases the intestinal transport of endosulfan into the mesenteric lymph.

EPMA Analysis of Inter-reaction Layer in Irradiated U3Si-Al Fuels (EPMA를 이용한 U3Si/Al 조사 핵연료의 반응층 분석)

  • Jung, Yang-Hong;Yoo, Byung-Ok;Kim, Hee-Moon;Park, Jong-Man;Kim, Myung-Han
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.355-362
    • /
    • 2004
  • Fission products and Inter reaction layer of $U_3Si-Al$ dispersion fuel, irradiated in HANARO research reactor with 121 kW/m of maximum liner power and 63 at% of average burn-up, was characterization by EPMA (Electron Probe Micro Analyzer). The fuel punching system developed by Irradiated Materials Examination Facility (IMEF) has used to make these samples for the EPMA. With this system a very small and thin specimen which is 1.57 mm in diameter and 2 mm in thickness respectively has been fabricated to protect the EPMA operator from high radioactive fuel and to mini-mize the equivalent dose rate less than 150 mSv/h. EPMA was performed to observe layers of sectional, Inter-reaction and oxide with specimens of cutting and polished. Stoichiometry in the Inter-reaction layer with $16{\mu}m$ of thickness was $U_{2.84}$ Si $Al_{14}$ with calibration of $UO_2$ and $U_{3.24}$ Si $Al_{14.1}$ with calibration of standard specimen. metallic precipitates in this layer were not observed using fission products examination.

Evaluation of 99mTc-MAG3-2-nitroimidazole for hypoxic tumor imaging

  • Lee, Yun-Sang;Kim, Young Joo;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.1
    • /
    • pp.18-25
    • /
    • 2019
  • 2-Nitroimidazole derivatives have been reported to accumulate in hypoxic tissue. We prepared a novel $^{99m}Tc-MAG_3$-2-nitroimidazole and evaluated the feasibility for hypoxia imaging agent. $Bz-MAG_3$-2-nitroimidazole was synthesized by direct coupling of $Bz-MAG_3$ and 2-nitroimidazole using dicyclohexylcarbodiimide. $Bz-MAG_3$-2-nitroimidazole was labeled with $^{99m}Tc$ in the presence of tartaric acid and $SnCl_2-2H_2O$ at $100^{\circ}C$ for 30 min. And the reaction mixture was purified by $C_{18}$ Sep-pak cartridge. The labeling efficiency and the radiochemical purity were checked by ITLC-SG/acetonitrile. The tumor was grown in balb/c mice for 8~13 days after the subcutaneous injection of tumor cells, CT-26 (murine colon adenocarcinoma cell). Biodistribution study and tumor autoradiography were performed in the xenografted mice after i.v injection of 74 kBq/0.1 mL and 19 MBq/0.1 mL of $^{99m}Tc-MAG_3$-2-nitroimidazole, respectively. In vivo images of $^{99m}Tc-MAG_3$-2-nitroimidazole in tumor bearing mice were obtained 1.5 hr post injection. The labeling efficiency was $45{\pm}20%$ and the radiochemical purity after purification was over 95%. Paper electrophoresis confirmed negative charge of $^{99m}Tc-MAG_3$-2-nitroimidazole. $^{99m}Tc-MAG_3$-2-nitroimidazole was very stable at room temperature and its protein binding was 53%. The $^{99m}Tc-MAG_3$-2-nitroimidazole exhibited high uptake in the liver, stomach and intestine. In biodistribution study using tumor bearing mice, the uptakes (% ID/g) of the tumor were $0.5{\pm}0.1$, $0.4{\pm}0.0$, $0.2{\pm}0.1$ and $0.1{\pm}0.1$ at 5, 15, 30 min and 4 hrs. Tumor/muscle ratio were $1.4{\pm}0.1$, $2.2{\pm}0.83$, $3.0{\pm}0.9$, and 3.7 (n=2) for 5, 15, 30 min and 4 hrs. The uptake in hypoxic area was found higher than in non-hypoxic area of tumor tissue by autoradiography. In vivo images showed the relatively faint uptake to the hypoxic tumor region. $^{99m}Tc-MAG_3$-2-nitroimidazole was successfully synthesized and found feasible for imaging hypoxia.

Improvement of the Occupational Safety and Health Act by the Comparison of the Domestic and Foreign Radon-related Policies (국내·외 라돈 관련 제도 비교를 통한 산업안전보건법 개선방안)

  • Lim, Dae Sung;Kim, Ki-Youn;Cho, Yong Min;Seo, Sung Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.3
    • /
    • pp.226-236
    • /
    • 2021
  • Objectives: Concerns have been raised about the possible health effects of radon on both workers and consumers with the spread of social attention to the impact of radon exposure. Thus, an entire raw material handling workshop was investigated, and standards for radon levels in the workplace were newly established at 600 Bq/m3. However, regulations on the management of workers exposed to radon are still insufficiently developed. Therefore, by comparative analysis of overseas and domestic radon-related regulations for workplaces, this study aims to suggest improvement plans of protection regulations under the Occupational Safety and Health Act (OSH Act) for the prevention of health disorders of radon-exposed workers. Methods: For overseas case studies, we consulted radon-related laws and reports officially published on the websites of the European Union (EU), the United States (U.S.) and the United Kingdom (UK) government agencies. Domestic law studies were conducted mainly on the Act on Protective Action Guidelines against Radiation in the Natural Environment and the OSH Act. Results: In Europe, the basic safety standards for protection against risks arising from radon (Council Directive 2013/59/EURATOM of 5 December 2013) was established by the EU. They recommend that the Member States manage radon level in workplaces based on this criterion. In the U.S., the standards for workplaces are controlled by the Occupational Safety and Health Administration (OSHA) and the Mine Safety and Health Administration (MSHA). Action on radon in the UK is specified in "Radon in the workplace" published by the Health and Safety Executive (HSE). Conclusions: The Act on Protective Action Guidelines against Radiation in the Natural Environment mainly refers to the management of workplaces that use or handle raw materials but does not have any provisions in terms of protecting naturally exposed workers. In the OSH Act, it is necessary to define whether radon is included in radiation for that reason that its current regulations have limitations in ensuring the safety workers who may be exposed to naturally occurring radon. The management standards are needed for workplaces that do not directly deal with radon but are likely to be exposed to radon. We propose that this could be specified in the regulations for the prevention of health damage caused by radiation, not in Article 125 of the OSH Act.

Chemical Characteristics and Deposition of Aerosols in the Cheju-Korea Straits (제주-대한해협 해역에서 에어로졸의 화학적 특성과 침적)

  • Suk Hyun, Kim;Hyunmi, Lee;Deok-Soo, Moon
    • Ocean and Polar Research
    • /
    • v.44 no.4
    • /
    • pp.297-310
    • /
    • 2022
  • To understand the chemical composition of aerosols in the Cheju-Korea Straits and their contribution to the ocean by deposition, aerosol samples were collected on board R/V Eardo from November 1997 to May 1999. The average concentrations of Al, NO3-, non-sea-salt (nss)-SO42-, and NH4+ in aerosols were 2.19, 5.59, 6.16 and 2.08 ㎍ m-3, respectively. The Al concentration in the high yellow dust period was about 100 times higher than that in the non-yellow dust period. The concentration ratio of NO3-/nss-SO42- ranged between 0.47 and 1.5, indicating that the aerosols in the Cheju-Korea Straits are under the effects of NOx and SOx emitted from China, Korea and Japan. The equivalent concentration ratio of [NH4+]/[nss-SO42-+ NO3-] with the average of 0.58±0.29 indicates that nss-SO42- and NO3- are not neutralized by NH4+. A high activity concentration of 210Pb with 1.13-1.23 mBq m-3 was observed during the high yellow dust period, indicating that 210Pb is easily adsorbed in the yellow dust originating from the continent of Asia. The distribution of 7Be and NH4+ concentrations showed a strong negative linear correlation during the low yellow dust period, April 1998. The total mineral dust flux in the Cheju-Korea Straits was estimated to be 1.21×106 tons yr-1, accounting for about 12% of the annual sediment discharge via the Nakdong River. The combined annual deposition of NH4+ and NO3- was 0.103 mole N m-2 yr-1 was estimated to support 4% of the annual primary productivity in the East China Sea.

Image Comparative Evaluation by PET/CT Equipment Using Phantom (팬텀을 활용한 PET/CT 장비 별 영상 비교 평가)

  • Moo-Jin Jeong;Jun-Chul Ham;Yong-Hoon Choi;Young-Kag Bahn;Han-Sang Lim;Jae-Sam Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.71-79
    • /
    • 2024
  • Purpose: This study aims to identify SUV, SNR, spatial resolution, and axial uniformity under the same reconstruction conditions and to find out the differences between equipment models. Materials and Methods: The equipment was GE's Discovery 600, 710, IQ, MI(GE Healthcare, USA), and the Phantom used ACR(American College of Radiology) Flangeless Esser Phantom and PET/SPECT Performance Phantom. The PET/SPECT Performance Phantom injected 18F-FDG at a concentration of 3.8 kBq/mL, and the ACR Flangeless Esser Phantom made the conditions for Hot Spot and Background activity for 4 : 1. Image evaluation was compared and evaluated for SUV, SNR, spatial resolution, and axial uniformity with the same reconstruction that added SharpIR of VPHD. Results: The SUVmax showed a difference up to 4.6% with an average of 2.71, 2.35, 1.89, and 1.43 from Hot Spot 1 to 4, and the SUVmean showed a difference up to 4.7% with 2.06, 1.75, 1.49, and 1.27. There was a difference up to 5% between equipment, and there was no significant difference between both SUVmax and SUVmean. SNR showed a difference up to 0.04 with an average of 0.37, 0.26, 0.18, and 0.11. FWHM showed a difference up to 0.27. Lastly, COV of axial uniformity was up to 0.018. Conclusion: SUV showed differences within 5% between equipment and showed no significant difference. This is considered to be used as basic data that can be used for the development and replacement of equipment because it has the advantage of being able to observe with a large number of equipment.

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF

Characterization of Particulates Containing Naturally Occurring Radioactive Materials in Phosphate Processing Facility (인광석 취급 산업체에서 발생하는 천연방사성물질 함유 입자의 특성 평가)

  • Lim, HaYan;Choi, Won Chul;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.7-13
    • /
    • 2014
  • Phosphate rock, phosphogypsum, and products in phosphate processing facility contain naturally occurring radioactive materials (NORM). Therefore, they may give rise to enhanced radiation dose to workers due to inhalation of airborne particulates. Internal dose due to particle inhalation varies depending on particle properties. The objective of the present study was to characterize particle properties at the largest phosphate processing facility in Korea. A cascade impactor was employed to sample airborne particulates at various processing areas in the plant. The collected samples were used for characterization of particle size distribution, particle concentration in the air, and shape analysis. Aerodynamic diameters of airborne particulates ranged 0.03-100 ${\mu}m$ with the highest concentration at the particle size range of 4.7-5.8 ${\mu}m$ (geometric mean = 5.22 ${\mu}m$) or 5.8-9.0 ${\mu}m$ (geometric mean = 7.22 ${\mu}m$). Particle concentrations in the air varied widely by sampling area up to more than two orders of magnitude. The large variation resulted from the variability of mechanical operations and building ventilations. The airborne particulates appeared as spheroids or rough spherical fragments across all sampling areas and sampled size intervals. Average mass densities of phosphate rocks, phosphogypsums, and fertilizers were 3.1-3.4, 2.1-2.6, and 1.7 $gcm^{-3}$, respectively. Radioactivity concentration of uranium series in phosphate rocks varied with country of origin, ranging 94-866 $Bqkg^{-1}$. Among the uranium series, uranium was mostly concentrated on products, including phosphoric acid or fertilizers whereas radium was concentrated on byproducts or phosphogypsum. No significant radioactivity of $^{226}Ra$ and $^{228}Ra$ were found in fertilizer. However, $^{40}K$ concentration in fertilizer was up to 5,000 Bq $g^{-1}$. The database established in this study can be used for the accurate risk assessment of workers due to inhalation of airborne particles containing NORM. In addition, the findings can be used as a basic data for development of safety standard and guide and for practical radiation safety management at the facility.

Development of Position Encoding Circuit for a Multi-Anode Position Sensitive Photomultiplier Tube (다중양극 위치민감형 광전자증배관을 위한 위치검출회로 개발)

  • Kwon, Sun-Il;Hong, Seong-Jong;Ito, Mikiko;Yoon, Hyun-Suk;Lee, Geon-Song;Sim, Kwang-Souk;Rhee, June-Tak;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.469-477
    • /
    • 2008
  • Purpose: The goal of this paper is to present the design and performance of a position encoding circuit for $16{\times}16$ array of position sensitive multi-anode photomultiplier tube for small animal PET scanners. This circuit which reduces the number of readout channels from 256 to 4 channels is based on a charge division method utilizing a resistor array. Materials and Methods: The position encoding circuit was simulated with PSpice before fabrication. The position encoding circuit reads out the signals from H9500 flat panel PMTs (Hamamatsu Photonics K.K., Japan) on which $1.5{\times}1.5{\times}7.0\;mm^3$ $L_{0.9}GSO$ ($Lu_{1.8}Gd_{0.2}SiO_{5}:Ce$) crystals were mounted. For coincidence detection, two different PET modules were used. One PET module consisted of a $29{\times}29\;L_{0.9}GSO$ crystal layer, and the other PET module two $28{\times}28$ and $29{\times}29\;L_{0.9}GSO$ crystal layers which have relative offsets by half a crystal pitch in x- and y-directions. The crystal mapping algorithm was also developed to identify crystals. Results: Each crystal was clearly visible in flood images. The crystal identification capability was enhanced further by changing the values of resistors near the edge of the resistor array. Energy resolutions of individual crystal were about 11.6%(SD 1.6). The flood images were segmented well with the proposed crystal mapping algorithm. Conclusion: The position encoding circuit resulted in a clear separation of crystals and sufficient energy resolutions with H9500 flat-panel PMT and $L_{0.9}GSO$ crystals. This circuit is good enough for use in small animal PET scanners.

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF