• 제목/요약/키워드: /t/-insertion

검색결과 365건 처리시간 0.03초

Effect of vibratory stimulation on pain during local anesthesia injections: a clinical trial

  • Ghorbanzadeh, Sajedeh;Alimadadi, Hoda;Zargar, Nazanin;Dianat, Omid
    • Restorative Dentistry and Endodontics
    • /
    • 제44권4호
    • /
    • pp.40.1-40.10
    • /
    • 2019
  • Objectives: This study aimed to assess the effect of DentalVibe on the level of pain experienced during anesthetic injections using 2 different techniques. Materials and Methods: This randomized crossover clinical trial evaluated 60 patients who required 2-session endodontic treatment. Labial infiltration (LI) anesthesia was administered in the anterior maxilla of 30 patients, while inferior alveolar nerve block (IANB) was performed in the remaining 30 patients. 1.8 mL of 2% lidocaine was injected at a rate of 1 mL/min using a 27-gauge needle. DentalVibe was randomly assigned to either the first or second injection session. A visual analog scale was used to determine participants' pain level during needle insertion and the anesthetic injection. The paired t-test was applied to assess the efficacy of DentalVibe for pain reduction. Results: In LI anesthesia, the pain level was 12.0 ± 15.5 and 38.1 ± 21.0 during needle insertion and 19.1 ± 16.1 and 48.9 ± 24.6 during the anesthetic injection using DentalVibe and the conventional method, respectively. In IANB, the pain level was 14.1 ± 15.9 and 35.1 ± 20.8 during needle insertion and 17.3 ± 14.2 and 39.5 ± 20.8 during the anesthetic injection using DentalVibe and the conventional method, respectively. DentalVibe significantly decreased the level of pain experienced during needle insertion and the anesthetic injection in anterior LI and mandibular IANB anesthesia. Conclusions: The results suggest that DentalVibe can be used to reduce the level of pain experienced by adult patients during needle insertion and anesthetic injection.

코르게이트 도파관을 사용한 위성통신용 저역통과 여파기의 설계 (Design of Low Pass Filters Using Corrugated Waveguide for Satellite Communications)

  • 김회종;최학근
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권2호
    • /
    • pp.41-46
    • /
    • 2013
  • 본 논문에서는 코르게이트 도파관을 사용한 위성통신용 저역통과 여파기를 제안하였다. 본 구조는 위성통신용 시스템으로 사용되기 위해 임피던스 트랜스포머와 T-junction을 배열한 코르게이트 도파관이 결합된 형태로 설계하였다. T-junction은 낮은 삽입손실과 높은 격리도의 특성을 만족시키기 위해 Chebyshev 함수를 사용하여 설계하였다. 임피던스 트랜스포머는 높은 반사손실을 위해 코르게이트 도파관의 양 끝에 높이가 다른 T-junction을 결합한 구조로 설계하였다. 제작된 여파기는 12.25 ~ 12.75 GHz에서는 반사손실이 35.4 dB이상, 삽입손실은 0.1 dB이하, 14.0 ~ 14.5 GHz에서는 격리도가 54.4 dB이상으로 나타났다. 따라서 본 논문에서 제안된 저역통과 여파기는 위성통신용 시스템에 사용 가능함을 보였다.

Identification of a Gene Involved in the Negative Regulation of Pyomelanin Production in Ralstonia solanacearum

  • Ahmad, Shabir;Lee, Seung Yeup;Khan, Raees;Kong, Hyun Gi;Son, Geun Ju;Roy, Nazish;Choi, Kihyuck;Lee, Seon-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권9호
    • /
    • pp.1692-1700
    • /
    • 2017
  • Ralstonia solanacearum causes bacterial wilt in a wide variety of host plant species and produces a melanin-like blackish-brown pigment in stationary phase when grown in minimal medium supplemented with tyrosine. To study melanin production regulation in R. solanacearum, five mutants exhibiting overproduction of melanin-like pigments were selected from a transposon (Tn) insertion mutant library of R. solanacearum SL341. Most of the mutants, except one (SL341T), were not complemented by the original gene or overproduced melanins. SL341T showed Tn insertion in a gene containing a conserved domain of eukaryotic transcription factor. The gene was annotated as a hypothetical protein, given its weak similarity to any known proteins. Upon complementation with its original gene, the mutant strains reverted to their wild-type phenotype. SL341T produced 3-folds more melanin at 72 h post-incubation compared with wild-type SL341 when grown in minimal medium supplemented with tyrosine. The chemical analysis of SL341T cultural filtrate revealed the accumulation of a higher amount of homogentisate, a major precursor of pyomelanin, and a lower amount of dihydroxyphenylalanine, an intermediate of eumelanin, compared with SL341. The expression study showed a relatively higher expression of hppD (encoding hydroxyphenylpyruvate dioxygenase) and lower expression of hmgA (encoding homogentisate dioxygenase) and nagL (encoding maleylacetoacetate isomerase) in SL341T than in SL341. SL341 showed a significantly higher expression of tyrosinase gene compared with SL341T at 48 h post-incubation. These results indicated that R. solanacearum produced both pyomelanin and eumelanin, and the novel hypothetical protein is involved in the negative regulation of melanin production.

교정용 미니스크류 임플랜트의 제거회전력 및 골형성에 관한 연굴 (REMOVAL TORQUE AND BONE FORMATION OF ORTHODONTIC MINISCREW IMPLANT)

  • 윤영국;류재준;서규원
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.492-505
    • /
    • 2007
  • Statement of problem: An orthodontic miniscrew implant has been used as a skeletal anchorage for orthodontic treatment. However, any relation among the influence of the cortical bone, morphologic differences of orthodontic miniscrew implants and new bone formation hasn't been made clear yet. Purpose: The purpose of this study was to evaluate whether the orthodontic miniscrew implant could work as an intraoral skeletal anchorage immediately and stably for orthodontic treatment after insertion of it. Material and methods: Two types of orthodontic miniscrew implants were used in this experiment; tapered type and straight type. One hundred and sixty eight orthodontic miniscrew implants were inserted into the tibiae of 21 rabbits and sacrificed on 3, 7, 11, 14, 21 and 28days later after insertion of them to study removal torque values and histologic and histomorphometric analyses. Results: The results were as follows. 1. The removal torque values of the tapered type were higher than those of the straight type in all groups(p<0.05). 2. There wasn't any distinguishing differences between the tapered type and the straight type about the new bone formation percentage. 3. The removal torque values for both the tapered type and the straight type were gradually decreased at early stages of the test but started to increase at the 7 days group of the straight type and the 11 days group of the tapered type. 4. New bone formation percentage was increased gradually for both the tapered and the straight types as time passed(p<0.05). 5. It was found that the tapered type showed lower values in the cortical bone about both the maximum equilibratory stress distribution and the maximum principal stress distribution than the straight type in linear finite elements analysis. Conclusion: According to the research, the removal torque values were decreased at 7 days group of the tapered type and 11 days group of the straight type after the insertion of the orthodontic miniscrew implants in tibiae of rabbits. Considering the human bone activity, it is better to apply the orthodontic force $3{\sim}4$ weeks later than to apply it immediately after the insertion of orthodontic miniscrew implants. Considering that general orthodontic force is about $250{\sim}500$ grams, the tapered type can be worked as a stable skeletal anchor age in an orthodontic treatment even if the orthodontic force is applied on it immediately after the insertion of it.

자궁내피임장치 카파티 380A에 관한 임상적 고찰 (Clinical Expenience with Copper T 380A Intrauterine Contraceptive Device)

  • 배병주;황영환
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제21권2호
    • /
    • pp.221-226
    • /
    • 1994
  • Copper T 380A intrauterine devices were inserted to nine thousand and nine hundred twenty women by 51 KAVS-member physicians since January 1, 1993 through December 31, 1993. This study was undertaken for the clinical analysis on a total of 9,920 women wearing Copper T 380A to grasp the effectivness as well as the expulsion rate due to a various side effects. The following features were the results of the study: 1. During the twelve months period, from January 1993 to December 1993, the largest number of IUD insertion per one physician is 740 cases and the smallest number 60 cases, the mean 195 cases. 2. After insertion of Copper T 380A, a total of 117 cases were removed the IUD;81 cases(0.8%) were due to extensive bleeding and 36 cases(O.36%) were due to pain. The pregnancy failure rate represented comparatively lower rate, 0.08% (8 cases) and the expulsion rate was 0.06%(6 cases). 3. The removal rate of Copper T 380A was different by physicians. The highest removal rate for bleeding was 3.13% and 13 physicians(25.5%) did not experience any bleeding cases. 4. For the removal rate for pain, 30 physicians(58.8%) did not experience any removal of IUD due to pain while 21 physicians(41.2%) removed IUD due to pain: 17 physiciansC33.4 %) had 0.1-1.5% of removal rate and 4 physiciansC7.0%) had 1.6-2.1% of removal rate. 5. A total of 43 physicians(84.3 %) did not experience any pregnancy failure case while 8 (15.7%) physicians was experienced pregnancy failure rate. Four physicians(7.8%) had 0.1-0.5% of pregnancy failure rate and 4 physicians had 0.6-1.0% of pregnancy failure rate. 6. Expulsion rate showed comparatively lower, 0.06% in this study. A total of 45 physicians (88.2%) did not experience any expulsion cases while 6 physicians(11.7%) had expulsion rate with the highest expulsion rate of 2.0%.

  • PDF

수직자기이방성을 갖는 [Pd/Co] Spin Valve 구조에서 자기저항효과 (Magnetoresistance Effect of [Pd/Co] Spin-valve with Perpendicular Anisotropy)

  • 최진협;이기암
    • 한국자기학회지
    • /
    • 제16권3호
    • /
    • pp.173-177
    • /
    • 2006
  • 수직자기이방성을 갖는 [Pd/Co] 다층박막으로 구성된 스핀밸브 구조에서 비자성층(space layer, SL) Pd 또는 Cu의 두께와 다층박막의 반복층수 N에 따른 자기저항효과의 의존성을 연구하였다. 비자성층을 Pd보다 Cu로 사용하였을 때 더 큰 자기저항비를 얻었다. 그리고 Cu층과 고정층 사이에 Co층을 삽입하는 경우 약 3배가량 자기저항비가 증가하는 것을 관찰하였다. $Ta_{(2.1nm)}/[Pd_{(0.61)}/Co_{(0.23)}]_4/Cu_{(2.37)}/Co_{(t)}/[Pd_{(0.61)}/Co_{(0.23)}]_2/FeMn_{(10.6)}/Ta_{(2.1)}$ 구조에서 삽입된 Co층의 두께가 0.62nm 또는 1.01nm에서 최대의 자기저항비 7.4%를 얻었다.

A Broadband Digital Step Attenuator with Low Phase Error and Low Insertion Loss in 0.18-${\mu}m$ SOI CMOS Technology

  • Cho, Moon-Kyu;Kim, Jeong-Geun;Baek, Donghyun
    • ETRI Journal
    • /
    • 제35권4호
    • /
    • pp.638-643
    • /
    • 2013
  • This paper presents a 5-bit digital step attenuator (DSA) using a commercial 0.18-${\mu}m$ silicon-on-insulator (SOI) process for the wideband phased array antenna. Both low insertion loss and low root mean square (RMS) phase error and amplitude error are achieved employing two attenuation topologies of the switched path attenuator and the switched T-type attenuator. The attenuation coverage of 31 dB with a least significant bit of 1 dB is achieved at DC to 20 GHz. The RMS phase error and amplitude error are less than $2.5^{\circ}$ and less than 0.5 dB, respectively. The measured insertion loss of the reference state is less than 5.5 dB at 10 GHz. The input return loss and output return loss are each less than 12 dB at DC to 20 GHz. The current consumption is nearly zero with a voltage supply of 1.8 V. The chip size is $0.93mm{\times}0.68mm$, including pads. To the best of the authors' knowledge, this is the first demonstration of a low phase error DC-to-20-GHz SOI DSA.

A force-Guided Control with Adaptive Accommodation Bor Complex Assembly

  • Sungchul Kang;Kim, Munsang;Lee, Chong W.;Lee, Kyo-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.14-19
    • /
    • 1998
  • In this paper, a target approachable force-guided control with adaptive accommodation for the complex assembly is presented. The complex assembly (CA) is defined as a task which deals with complex shaped parts including concavity or whose environment is so complex that unexpected contacts occur frequently during insertion. CA tasks are encountered frequently in the field of the manufacturing automation and various robot applications. To make CA successful, both the bounded wrench condition and the target approachability condition should be satisfied simultaneously during insertion. By applying the convex optimization technique, an optimum target approaching twist can be determined at each instantaneous contact state as a global minimum solution. Incorporated with an admissible perturbation method, a new CA algorithm using only the sensed resultant wrench and the target twist is developed without motion planning nor contact analysis which requires the geometry of the part and the environment. Finally, a VME-bus based real-time control system is built to experiment various CA task. T-insertion task as a planar CA and double-peg assembly task as a spacial assembly were successfully executed by implementing the new force-guided control with adaptive accommodation.

  • PDF

임상 간호사의 역할과부담과 기본간호술 수행 시의 무균술 이행의 관계 (Relationship between Nursing Task Overload and Aseptic Technique Performance in Clinical Nursing Skills)

  • 이선옥;박경연
    • 동서간호학연구지
    • /
    • 제15권1호
    • /
    • pp.18-25
    • /
    • 2009
  • Purpose: The study was investigated to identify the relationship between nursing workload and aseptic technique performance by clinical nurses, and to decrease the incidence rate of nosocomial infection. Methods: Participants (N=283) were recruited in B city from April to June 2007. The data were collected by a structured questionnaire and analyzed with descriptive statistics, t-test, ANOVA and Pearson's correlation coefficient. Results: Nursing workload was rated 9.85 out of a total score of 15. The level of aseptic technique performance as the basis for insertion of a Foley catheter was 42.72 out of a total score of 50, and as basis for insertion of intravenous catheter for fluid therapy was 40.11 out of a total score of 55. There was not a significant relationship between aseptic technique performance and nursing workload. There was a significant positive relationship between the aseptic technique performance in insertion of Foley catheter and that of intravenous catheter for fluid therapy (r=.279, p<.001). Conclusions: Attention to asepsis by nurses is crucial in nosocomial infection-related clinical nursing skills.

삼중 E-평면형 구조의 K-인버터특성에 관한 연구 (A Study on K-Inverter Characteristics for Triple E-Plane type Structures)

  • 오영주
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1990년도 제5회 파동 및 레이저 학술발표회 5th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.252-256
    • /
    • 1990
  • In this paper, we proposed E-plane structures to obtain the high insertion loss at stopband and show that T-equivalent and K-inverter of Triple E-plane structures are better than those of All-Metal Insert E-plane structures. To show the characteristics first order bandpass filter are designed and tested at X band.

  • PDF