• Title/Summary/Keyword: (GC-MS) gas chromatography-mass spectrometry analysis

Search Result 359, Processing Time 0.028 seconds

A Sensitive Determination of Plasma Free Fatty Acids Following Tert-butyldimethylsilyl Derivatization using Gas Chromatography-Mass Spectrometry for Screening of Fatty Acid Oxidation Disorders (지방산대사이상질환 스크리닝을 위한 TBDMS 유도체화 후 GC-MS를 이용한 혈장 중 유리지방산의 분석)

  • Yoon, Hye-Ran;Thapa, Maheshwor
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.17 no.2
    • /
    • pp.39-47
    • /
    • 2017
  • Purpose: A sensitive gas chromatography mass spectrometry (GC-MS) method was developed for screening of fatty acid oxidation disorders. Methods: The assay utilized a simple protein precipitation with sulfosalicylic acid followed by tert-butyl dimethylsilyl (TBDMS) derivatization of hydroxyl functional group by N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA). Results: Calibration curves of spiked pooled plasma showed a linear relationship in the range of 0.01 ng -2 mg with correlation coefficient value greater than 0.98. Limits of detection (LOD) and limits of quantification (LOQ) were found in the range of 0.9-8.8 ng and 9-88 ng, respectively. Conclusion: The new developed method might be useful for a rapid, sensitive screening of inherited fatty acid oxidation disorders. In addition, the method expected to be one of the alternative method for screening newborns of metabolic disorders in the laboratories where expensive MS/MS is unavailable.

  • PDF

Determination of panthenol, cholecalciferol and tocopherol in cosmetic products by gas chromatography-mass spectrometry in SIM mode

  • Hye-Jin Jeong;Myo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.22 no.2
    • /
    • pp.153-160
    • /
    • 1996
  • A novel simple method to detect vitamins in cosmetic products by gas chromatography-mass spectrometry(GC-MS) has been developed. Three vitamins(panthenol, cholecalciferol and tocopherol) were used for this study. Vitamins were prepared by dissolving in tetrahydrofuran(THF), and silylated with bis-trimethylsilyltrifluoroacetamide-trichloromethylsilane(BSTFA). Silated vitamins were separated on a fuses-silica capillary column coated with DB-5. The identification of each vitamin was accomplished by retention time and mass spectrum library search with a computer, and the quantitation was made in the selected-ion monitoring(SIM) mode of GC-MS. SIM mode had given sensitivity to determine 50pg of panthenol, 285pg of cholecalciferol and 130pg of tocopherol. Linearity was maintained over the range 0.005-0.20% for each vitamin. Each cosmetic product(i.e. hair tonic and lotion) was found to contain amounts of the vitamins. This method was sensitive and gave 77.5-99.9% recovery of each vitamin from these cosmetic products. From these results, we concluded that silylation with BSTFA followed by GC-MS analysis allows the simple, covenient and exact determination of panthenol, cholecalciferol and tocopherol.

  • PDF

Development of Analytical Technology Using the HS-SPME-GC/FID for Monitoring Aromatic Solvents in Urine

  • Lee, Mi-Young;Chung, Yun Kyung;Shin, Kyong-Sok
    • Mass Spectrometry Letters
    • /
    • v.4 no.1
    • /
    • pp.18-20
    • /
    • 2013
  • Headspace solid phase micro-extraction gas chromatography/flame ionization detection (HS-SPME-GC/FID) method was compared with headspace gas chromatography/mass selective detection (HS-GC/MS). Organic solvent-spiked urine as well as urine samples from workspace was analyzed under optimal condition of each method. Detection limit of each compound by HS-SPME-GC/FID was $3.4-9.5{\mu}g/L$, which enabled trace analysis of organic solvents in urine. Linear range of each organic solvent was $10-400{\mu}g/L$, with fair correlation coefficient between 0.992 and 0.999. The detection sensitivity was 4 times better than HS-GC/MS in selected ion monitoring (SIM) mode. Accuracy and precision was confirmed using commercial reference material, with accuracy around 90% and precision less than 4.6% of coefficient of variance. Among 48 urine samples from workplace, toluene was detected from 45 samples in the range of $20-324{\mu}g/L$, but no other solvents were found. As a method for trace analysis, SPME HS GC/FID showed high sensitivity for biological monitoring of organic solvent in urine.

A Study on the determination of Residual Antibiotics and Synthetic Antibacterial Agents in Meas (II) - Simultaneous Gas Charomatography/Mass Spectrometry Analysis of Penicillin G, Chloramphenicol and Thiamphenicol - (식육중의 잔류 항생.항균제의 검정에 관한 연구 (II) - Penicillin G , Chloramphenicol, Thiamphenicol, Gas chromatography/Mass spectrometry 동시 분석 -)

  • 류재천;양종순;서지원;김명수;박종세
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.1
    • /
    • pp.9-15
    • /
    • 1993
  • In an attempt to quantitate and qualitate residual antibiotics and antibacterial agents in meat simultaneously, we studied a gas chromatography-mass spectrometry(GC/M8) analysis. For a simultaneous analysis of penicillin G, chloramphenicol and thiamphenicol in meat, a simple and rapid clean-up procedure including extraction with 0.01 M EDTA-2Na Mcilvaine buffer (pH 4.0), defatting with n-hexane, and elution with 0.01M-methanolic oxalic acid from Bond Elute $C_{18}$ cartridge, and quantitation by selected ion monitoring (SIM) mode after derivatization was performed. The recoveries (%) of penicillin G, chloramphenicol and thiamphenicol (CV, %) at 1 ppm fortification level were 63.5 (7.6), 76.3 (8.1) and 84.7 (2.0), and the detection limits of those were 0.6, 0.085 and $0.084\;\mu\textrm{g}$ beef, respectively. This method using 81M mode allows excellent detection and quantitation of residual antibiotics and antibacterial agents in meat. Moreover, confirmation by a full scan electron impact mass spectrum is possible if residual level in the sample in above 1 ppm.

  • PDF

Headspace-Solid Phase Microextraction (HS-SPME) Analysis of Korean Fermented Soybean Pastes

  • Lee, Seung-Joo
    • Food Science and Biotechnology
    • /
    • v.18 no.3
    • /
    • pp.700-705
    • /
    • 2009
  • In this study, the volatile compounds in 9 commercial fermented soybean pastes were extracted and analyzed by headspace-solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS), respectively. A total of 63 volatile components, including 21 esters, 7 alcohols, 7 acids, 8 pyrazines, 5 volatile phenols, 3 ketones, 6 aldehydes, and 6 miscellaneous compounds, were identified. Esters, acids, and pyrazines were the largest groups among the quantified volatiles. About 50% of the total quantified volatile material was contributed by 5 compounds in 9 soybean paste samples; ethyl hexadecanoate, acetic acid, butanoic acid, 2/3-methyl butanoic acid, and tetramethyl-pyrazine. Three samples (CJW, SIN, and HAE) made by Aspergillus oryzae inoculation showed similar volatile patterns as shown in principal component analyses to GC-MS data sets, which showed higher levels in ethyl esters and 2-methoxy-4-vinylphenol. Traditional fermented soybean pastes showed overall higher levels in pyrazines and acids contents.

Volatile Compounds for Discrimination between Beef, Pork, and Their Admixture Using Solid-Phase-Microextraction-Gas Chromatography-Mass Spectrometry (SPME-GC-MS) and Chemometrics Analysis

  • Zubayed Ahamed;Jin-Kyu Seo;Jeong-Uk Eom;Han-Sul Yang
    • Food Science of Animal Resources
    • /
    • v.44 no.4
    • /
    • pp.934-950
    • /
    • 2024
  • This study addresses the prevalent issue of meat species authentication and adulteration through a chemometrics-based approach, crucial for upholding public health and ensuring a fair marketplace. Volatile compounds were extracted and analyzed using headspace-solid-phase-microextraction-gas chromatography-mass spectrometry. Adulterated meat samples were effectively identified through principal component analysis (PCA) and partial least square-discriminant analysis (PLS-DA). Through variable importance in projection scores and a Random Forest test, 11 key compounds, including nonanal, octanal, hexadecanal, benzaldehyde, 1-octanol, hexanoic acid, heptanoic acid, octanoic acid, and 2-acetylpyrrole for beef, and hexanal and 1-octen-3-ol for pork, were robustly identified as biomarkers. These compounds exhibited a discernible trend in adulterated samples based on adulteration ratios, evident in a heatmap. Notably, lipid degradation compounds strongly influenced meat discrimination. PCA and PLS-DA yielded significant sample separation, with the first two components capturing 80% and 72.1% of total variance, respectively. This technique could be a reliable method for detecting meat adulteration in cooked meat.

Quality Assessment of Curcuma longa L. by Gas Chromatography-Mass Spectrometry Fingerprint, Principle Components Analysis and Hierarchical Clustering Analysis

  • Li, Ming;Zhou, Xin;Zhao, Yang;Wang, Dao-Ping;Hu, Xiao-Na
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2287-2293
    • /
    • 2009
  • Gas Chromatography-Mass Spectrometry (GC-MS) fingerprint analysis, Principle Components Analysis (PCA), and Hierarchical Cluster Analysis (HCA) were introduced for quality assessment of Curcuma longa L. (C. longa). The GC-MS fingerprint method was developed and validated by analyzing 33 batches of samples of C. longa from different geographic locations. 18 chromatographic peaks were selected as characteristic peaks and their relative peak areas (RPA) were calculated for quantitative expression. Two principal components (PCs) were extracted by PCA. C. longa collected from Guizhou and Fujian were separated from other samples by PC1, capturing 71.83% of variance. While, PC2 contributed for their further separation, capturing 11.13% of variance. HCA confirmed the result of PCA analysis. Therefore, GC-MS fingerprint study with chemometric techniques provides a very flexible and reliable method for quality assessment of C. longa.

Analysis of Flavor-related Compounds from Tobacco using SPME-GC-MS (SPME-GC-MS를 이용한 담배와 관련된 향료의 분석)

  • Park, Gyo-Beom;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.109-114
    • /
    • 2001
  • The flavor-related compounds contained in tobacco were analyzed by selected ion monitoring (SIM) method using headspace SPME gas chromatography-mass spectrometry(GC-MS). Flavor-related compounds were estragole pulegone, trans-anethole, safrole, piperonal, eugenol, methyleugenol, coumarin, trans-isoeugenol, trans-methyleugenol and myristicin. More than on of the flavor-related compounds were detected in the range $0.001-1.3{\mu}g/g$ from all brands of tobacco studied. The recovery was ranged from 89.1 to 102.9% and relative standard deviation was ranged from 2.6 to 25.2%.

  • PDF

Chiral Derivatization of Hydroxycarboxylic Acids Using 2,4,6-Trichlorobenzoyl Chloride as a Highly Efficient Regioselective Esterification Reagent for Gas Chromatography-Mass Spectrometry

  • Park, Jeong Hyeok;Han, Sang Yun
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.103-107
    • /
    • 2020
  • We report the application of 2,4,6-trichlorobenzoyl chloride (often referred to as Yamaguchi esterification reagent) for the selective derivatization of the carboxylic group for GC-MS with the sample preparation method optimized for GC-MS analysis. The reagent was shown to be capable of selectively turning the carboxylic group into a reaction center, i.e., anhydride, of which the further reaction was directed to a near complete formation of required esters by unique steric and electronic effects of the reagent. Using the developed method, the chiral separation of hydroxycarboxylic acids by GC-MS using non-chiral columns was successfully demonstrated.

Analysis of Antioxidants in Fatty Foods Using Gas Chromatography/Mass Spectrometry (식품 중 Gas Chromatography/Mass Spectrometry를 이용한 산화방지제의 분석에 관한 연구)

  • 이정애;노동석
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.3
    • /
    • pp.210-216
    • /
    • 1997
  • The prevention of oxidative degradation in fats and oils is largely controlled by the use of synthetic phenolic antioxidants. Antioxidants, BHA: 2-&-3-tert-butyl-4-hydroxyanisol, BHT: 3,5-di-tert-butyl-4-hydroxytoluene, TBHQ: tert-butylhydroquinone, PG: propyl gallate, PTG: pentyl gallate, OG:octyl gallate, were extracted from fatty foods with hexane and from hexane layer to presaturated acetonitrile with hexane. The polar phenolic hydroxyl groups of antioxidants were silylated with MSTFA and injected to Gas Chromatography/Mass Spectrometry. The calibration plots were linear in the investigated range, 0.1~10.0 $\mu\textrm{g}$/g. The limit of detection for 6 phenolic antioxidants was 0.1 $\mu\textrm{g}$/g. Recoveries and reproducibilities from samples fortified at 1.0 $\mu\textrm{g}$/g were in the range of 70~90% and 0.5~13%, respectively. The simultaneous determination of phenolic antioxidants in fatty foods using GC/MS-SIM mode and macro program was described.

  • PDF