• Title/Summary/Keyword: (D/C) ratio

Search Result 2,555, Processing Time 0.037 seconds

A Clipping-free Multi-bit $\Sigma\Delta$ Modulator with Digital-controlled Analog Integrators (디지털 제어 적분형의 차단 현상이 없는 A/D 다중 비트 $\Sigma\Delta$ 변조기)

  • 이동연;김원찬
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.4
    • /
    • pp.26-35
    • /
    • 1997
  • This paper proposes a multi-bit $\Sigma\Delta$ modulator arcitecture which eliminates signal clipping problem. To avoid signal clipping, the output values of intgrators are monitored and modified by a reference value. This oepration is recorded as a digital code to restore actual signal value. Due to the digital code, the substraction of feedback value from the multi-bit quantizer can be calculated by a digital adder and this simplifies dAC operation making the accurate DAC of conventional multi-bit $\Sigma\Delta$ modulator scheme unnecessary. These features make N-th modulator can be implemented by sharing an integrator among N stages to decrease the required chip area. As an experimental example, a 4th order .sum..DELTA. modulator with oversampling ratio of 64 was simulated to show over 130 DB SNR at rail-to-rail input sinusoidal signal.

  • PDF

A Study on the reparation of Cobalt Oxide Powders by the Emulsion Evaporation Technique (에멀젼 증발법에 의한 산화코발트 분말의 제조에 관한 연구)

  • 손성호;안재우;이응조
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.5
    • /
    • pp.411-419
    • /
    • 1993
  • A process for the preparation of cobalt oxide powders was developed by the evaporaton of emulsion containing cobalt. The characteristics of powders were examined by means of DTA, X-ray diffracton, SEM, PSA. Cobalt oxide powders were produced by evaporating the emulsion prepared by mixing cobalt sulfate solution and organic phase consisted of kerosene, Span 80 and D2EHPA in the kerosene bath at 16$0^{\circ}C$, then the precursor obtained was calcined at 100$0^{\circ}C$. As the concentration of cobalt ions in the aqueous solution, Span 80 and the stirring speed increased, the mean size of cobalt oxide powders decreased and the size distribution was improved. At the volume ratio of one of the aqueous to organic phase, the finest mean size and the optimum size distribution was obtained. On the other hand the concentration of D2EHPA and liquid paraffin had little effect on the mean size as well as on the size distribution of powders.

  • PDF

An investigation on flow characteristics of two dimensional inclined wall attaching offset jet (단이 진 경사벽면에 부착되는 2차원 제트유동에 관한 연구)

  • 송흥복;심재경;윤순현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.52-66
    • /
    • 1998
  • An experimental study on the flow characteristics was performed for a two-dimensional turbulent wall attaching offset jet at different oblique angles to a surface. The flow characteristics were investigated by using a split film probe with the modified Stock's calibration method. The jet mean velocity, turbulent intensity, wall static pressure coefficient profiles, and time-averaged reattachment point were measured at the Reynolds number Re (based on the nozzle width, D) ranging from 17700 to 53200, the offset ratio H/D from 2.5 to 10, and the inclined angle .alpha. from 0.deg. C to 40.deg. C. The Correlations between the maximum pressure position, minimum pressure position, and reattachment point and offset ratios, and inclined angles are presented.

  • PDF

Suggestions for the Estimation of the Methane Emission from a Landfill Site

  • Lee, Kyungho;Jeon, Eunjeong;Lee, Youngmin;Park, Junghyun
    • Journal of Urban Science
    • /
    • v.9 no.1
    • /
    • pp.69-73
    • /
    • 2020
  • Sudokwon landfill("Sudokwon" means regions of Seoul, Kyunggi and Incheon metropolitan cities in Korea), the world's largest sanitary landfill, has been systematically managing statistics on the incoming and dumping wastes and satisfactorily controlling pollutants including leachate and LFG. According to our long time experience of LFG field monitoring, the emission of GHG from landfill estimated by the IPCC Guideline showed much difference with our results. C&D waste has high concentration of sulfate compared to other wastes. Increased C&D waste of dumping waste had changed the COD/sulfate ratio in the landfill, which caused the increase of H2S gas and the decrease of CH4 gas. But the IPCC estimation method does not consider the effects of sulfate. In addition to that, the oxidation factor of the cover soil is set to the default values of 0.1 but the measured values by the field monitoring, are showing much higher than that, especially in the closed landfill.

Numerical study of wind load on the high-rise building (고층건물에 작용하는 풍하중에 관한 수치 해석적 연구)

  • Song, C.S.;Park, S.O.;Kim, D.W.;Ha, Y.C.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.205-208
    • /
    • 2008
  • The wind load on building surface is numerically investigated. The geometry of target building is a square cross section and aspect ratio (height (H) to width (d)) is 6. On building surface, the pressure was measured, compared to obtained value from numerical simulation. The numerical simulations were done using URANS with three different turbulence models such as v2-f model, k-${\omega}$model, and k-${\varepsilon}$ model, respectively. The v2-f model showed the best agreement with experimental data in simulating mean pressure coefficients on front, rear and side surface. But unsteady characteristics of pressure history measured on surface is shown a discrepancy between experiment and numerical simulation.

  • PDF

A study on DC breakdown strength due to variation of specimen shape of epoxy/SiO$_{2}$ compound material treated with silane coupling agent

  • 김명호;김재환;김경환;박찬옥;손인환;박재준
    • Electrical & Electronic Materials
    • /
    • v.5 no.4
    • /
    • pp.393-399
    • /
    • 1992
  • In order to increase the coupling strength between bisphenol-A type epoxy resin and filler SiO$_{2}$ it was treated to filler with silane coupling agent[KBM-603]. To observe how silane coupling agent effects on dielectric breakdown strength of Epoxy/SiO$_{2}$ compound material, specimens of eight type were made like following. (A-1, A-2), (B-1, B-2), (C-1, C-2), (D-1, D-2) (see 2-2. Specimen) Specimen treated with silane coupling agent had always bigger dielectric breakdown strength than non-treated specimen. Under the influence of silane coupling agent, increment ratio of dielectric breakdown strength at specimen manufactured by hand drill was very bigger than that of specimen inserted spherical electrode. Therefore, as the specimen shape was varied, it was studied on effect that silane coupling agent affects on dielectric breakdown strength of Epoxy/SiO$_{2}$ compound material.

  • PDF

Optimization of the Extrusion Processing Conditions of Soymilk Residue and Corn Grits Mixture (두유박과 옥분 혼합물 압출성형 제조공정의 최적화)

  • 한규홍;김병용
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.8
    • /
    • pp.1270-1277
    • /
    • 2003
  • The extrusion conditions of the soymilk residue and corn grits mixtures were optimized. The experiment was designed according to the D-optimal design of response surface methodology (RSM), which shows 18 experimental points including 4 replicates for three independent variables (screw speed, water content and die temperature). The responses variables such as bending force, expansion ratio, bulk density, water solubility index (WSI), water absorption index (WAI), and color values (L*, a*, b*) were evaluated using response surface analysis. Expansion ratio and WSI decreased with increasing water content, whereas bulk density tended to increase with increasing water content. While greater screw speeds enhanced WSI and yellowness, higher moisture contents decreased the expansion ratio and WSI value. However, die temperature did not influence upon the response variables. The optimum extrusion conditions by numerical and graphical methods were similar: the screw speed, water content, and die temperature were 250 rpm, 22.43% and l28.16$^{\circ}C$ by the numerical method; 250 rpm, 22.43%, and 128.02$^{\circ}C$ by graphical method.

HMGCoA reductase inhibitor의 혈청 지질 개선효과

  • 이명묵
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.332-332
    • /
    • 1994
  • 식이습관을 바꾸지 않는 상태에서 4주간의 placebo 투여후 혈청 Total-C치가 240mg/dl 이상인 원발성 고콜레스테 혈증환자 25예씩 두군으로 하여 제1군은 lovastatin 20mg에서 80mg을 1일 1회 저녁에 12주간 투여하였고, 제2군은 pravastatin 5mg을 12주간 아침 저녁으로 2회 경구 투여하였다. Lovastatin과 pravastatin 12주 투여후 혈청 Total-C치는 309$\pm$46mg/d1에서 201$\pm$37mg/d1로, 281$\pm$41mg/d1에서 218$\pm$31mg/d1로, 혈청LDL-C치는 230$\pm$46mg/d1에서 125$\pm$40mg/d1로, 199$\pm$46mg/d1에서 137$\pm$37mg/d1로 각각 유의하게 감소 하였다. (p < 0.005)혈청 Apo B치는 183$\pm$32mg/d1에서 114$\pm$26mg/d1로, 164$\pm$38mg/d1에서 123$\pm$20mg/d1로, 혈청 Apo B / Apo A-1 ratio는 1.6$\pm$0.4에서 1.0$\pm$0.3으로, 1.4$\pm$0.5에서 1.0$\pm$0.3으로 각각 유의하게 감소하였다. (p < 0.005) Lovastatin 및 pravastatin 투여후 임상적으로 의미있는 중상이나 검사상 이상 소견은 관찰되지 않았다.

  • PDF

Raman Characteristics of Polycrystalline 3C-SiC Thin Films (다결정 3C-SiC 박막의 라만 특성)

  • Jeong, Jun-Ho;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.357-358
    • /
    • 2007
  • Raman spectra of poly (polycrystalline) 3C-SiC thin films, which were deposited on the oxidized Si substrate by APCVD, have been measured. They were used to study the mechanical characteristics of poly 3C-SiC grown in various temperatures. TO and LO modes of 2.0 m poly 3C-SiC grown at 1180 C occurred at 794.4 and $965.7\;cm^{-1}$. Their FWHMs (full width half maximum) were used to investigate the stress and the disorder of 3C-SiC. The broad FWHM can explain that the crystallinity of 3C-SiC grown at 1180 C becomes poly crystalline instead of the disordered crystal. The ratio of intensity $I_{(LO)}/I_{(TO)}$ 1.0 means that the crystal defect of 3C-SiC/$SiO_2$/Si is small. The biaxial stress of poly 3C-SiC was obtained as 428 MPa. In the interface of 3C-SiC/$SiO_2$, the phonon mode of C-O bonding appeared at $1122.6\;cm^{-1}$. The phonon modes related to D and G bands of C-C bonding were measured at 1355.8 and $1596.8\;cm^{-1}$ respectively.

  • PDF

Effect of Carbon Couch Side Rail and Vac-lok In case of Lung RPO irradiation (Lung RPO 선량전달시, Carbon Couch Side Rail과 Vac-lok이 미치는 영향)

  • Kim, Seok Min;Gwak, Geun Tak;Lee, Seung Hun;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.27-34
    • /
    • 2018
  • Purpose : To evaluate the effect of carbon couch side rail and vacuum immobilization device in case of lung RPO irradiation. Materials and Methods : The 10, 20, 30 mm thickness of vac-lok's right side were obtained. To measure of doses, glass dosimeters were used and measured reference point is left lung center at the phantom. A, B, C, and D points are left, right, down, and up directions based on the center point. In the state of Side-Rail-Out, place the without vac-lok, with the thickness of 10, 20, and 30 mm vac-lok. After the glass dosimeters was inserted in center, A, B, C, and D points, 100 MU of 6 MV X-ray were irradiated to the referenced center point in the condition of $10{\times}10cm^2$ field size, SAD 100 cm, gantry angle 225, 300 MU/min dose rate. Five measurements were made for each point. In the state of Side-Rail-In, five measurement were made for each point under the same conditions. The average is measured on each of the five Side-Rail-Out and Side-Rail-In measurements. Results : In the presence of side rail, the dose reduction ratio was -11.8 %, -12.3 %, -4.1 %, -12.3 %, -7.3 % for each A, B, C, and D points. In the state of Side-Rail-Out, the dose reduction ratio for the using 10 mm thickness of vac-lok was -0.9 % than without vac-lok. The dose reduction ratio for the using 20 mm thickness of vac-lok was -2.0 %, for the using 30 mm thickness of the vac-lok was -3.0 % than without vac-lok. In the state of Side-Rail-In, the dose reduction ratio for the using 10 mm thickness of vac-lok was -1.0 % than without vac-lok. The dose reduction ratio for the using 20 mm vac-lok was -2.1 %, for the using 30 mm vac-lok was -3.0 % than without vac-lok. Based on the value of no vac-lok dose in the Side-Rail-In state, The dose reduction ratios for the using 10 mm, 20 mm and 30 mm thickness of vac-loks In the Side-Rail-Out that the center point were -12.7 %, -13.7 %, -14.2 % and -12.8 %, -13.8 %, -14.5 % respectively at point A. The dose reduction ratios for the same conditions to the B point were -4.9 %, -6.1 %, -7.1 % and -13.4 %, -14.4 %, -15.5 % respectively at point C. The dose reduction ratios for the same conditions to the D point were -8.4 %, -9.0 %, -10.4 % respectively. Conclusion : The attenuation was caused by presence of side rails and thickness of vac-lok. Pay attention to these attenuation factors, making it a more effective radiation therapy.

  • PDF