• Title/Summary/Keyword: (0,1)-matrix

검색결과 2,545건 처리시간 0.031초

전처리 필터를 이용한 선형 위성 LOT 기저의 설계에 관한 연구 (On the Design of the Linear Phase Lapped Orthogonal Transform Bases Using the Prefilter Approach)

  • 이창우;이상욱
    • 전자공학회논문지B
    • /
    • 제31B권7호
    • /
    • pp.91-100
    • /
    • 1994
  • The lapped orthogonal transform(LOT) has been recently proposed to alleviate the blocking effects in transform coding. The LOT is known to provide an improved coding gain than the conventional transform. In this paper, we propose a prefilter approach to design the LOT bases with the view of maximizing the transform coding gain. Since the nonlinear phase basis is inappropriate to the image coding only the linear phase basis is considered in this paper. Our approach is mainly based on decomposing the transform matrix into the orthogonal matrix and the prefilter matrix. And by assuming that the input is the 1st order Markov source we design the prefilter matrix and the orthogonal matirx maximizing the transform coding gain. The computer simulation results show that the proposed LOT provides about 0.6~0.8 dB PSNR gain over the DCT and about 0.2~0.3 dB PSNR gain over the conventional LOT [7]. Also, the subjective test reveals that the proposed LOT shows less blocking effect than the DCT.

  • PDF

폴리에틸렌옥사이드를 이용한 세파트리진프로필렌글리콜 서방성매트릭스 정제의 제조 및 평가 (Pharmaceutical Formulation and Evaluation of Sustained - Release Hydrophilic Matrix Tablet of Cefatrizine Propyleneglycol Using Polyethylene Oxide)

  • 이언형;박선영;지웅길;김동출
    • Journal of Pharmaceutical Investigation
    • /
    • 제31권1호
    • /
    • pp.37-41
    • /
    • 2001
  • Various characteristics of polyethylene oxide (PEO) are useful for drug delivery systems. In this study, PEO was used as a sustained release matrix system containing cefatrizine propyleneglycol (Cefa-PG) which is a new semi-synthetic broad-spectrum and orally active cephalosporin. Five kinds of sustained release matrix tablets were formulated with various content of PEO and other ingredients. And three types of matrix tablets were formulated of which compositions were the same but the hardness was different. It was found that PEO content influenced drug release rate. Increasing PEO content, the drug release rate from matrix tablets was decreased. In addition, Avicel, one of the ingredients of matrix components, changed the drug release from the sustained release PEO matrix tablets. With increasing Avicel content, the rate of drug release was increased. For the effect of hardness of matrix tablets, the rate of drug release is decreased with increasing hardness. In comparison of bioavailability parameters after oral administration of Cefa-PG PEO matrix tablets and general Cefa-PG capsule in beagle dog, the sustained release PEO matrix tablets is more useful than a general dosage form. $AUC^{0-12}$ of the sustained release PEO matrix tablet and the general dosage form was 1.16 and 0.644 respectively.

  • PDF

Morphological optimization of process parameters of randomly oriented carbon/carbon composite

  • Raunija, Thakur Sudesh Kumar;Manwatkar, Sushant Krunal;Sharma, Sharad Chandra;Verma, Anil
    • Carbon letters
    • /
    • 제15권1호
    • /
    • pp.25-31
    • /
    • 2014
  • A microstructure analysis is carried out to optimize the process parameters of a randomly oriented discrete length hybrid carbon fiber reinforced carbon matrix composite. The composite is fabricated by moulding of a slurry into a preform, followed by hot-pressing and carbonization. Heating rates of 0.1, 0.2, 0.3, 0.5, 1, and $3.3^{\circ}C/min$ and pressures of 5, 10, 15, and 20 MPa are applied during hot-pressing. Matrix precursor to reinforcement weight ratios of 70:30, 50:50, and 30:70 are also considered. A microstructure analysis of the carbon/carbon compacts is performed for each variant. Higher heating rates give bloated compacts whereas low heating rates give bloating-free, fine microstructure compacts. The compacts fabricated at higher pressure have displayed side oozing of molten pitch and discrete length carbon fibers. The microstructure of the compacts fabricated at low pressure shows a lack of densification. The compacts with low matrix precursor to reinforcement weight ratios have insufficient bonding agent to bind the reinforcement whereas the higher matrix precursor to reinforcement weight ratio results in a plaster-like structure. Based on the microstructure analysis, a heating rate of $0.2^{\circ}C/min$, pressure of 15 MPa, and a matrix precursor to reinforcement ratio of 50:50 are found to be optimum w.r.t attaining bloating-free densification and processing time.

In vitro 환경에서 엘라스틴을 혼합한 콜라겐 진피 지지체의 내구성 (The Durability of Elastin-Incorporated Collagen Matrix for Dermal Substitute in Vitro Condition)

  • 유대현;홍종원;탁관철
    • Archives of Plastic Surgery
    • /
    • 제35권1호
    • /
    • pp.7-12
    • /
    • 2008
  • Purpose: Since the report of artificial dermis manufacturing method using collagen by Yannas in 1980, collagen has been effectively used as dermal substitute with its merits such as, lower antigeneicity, controllable biodegradation rate, and minimal inflammatory cytotoxic properties in the dermal tissue engineering field. However, weak mechanical durability was the main drawback of collagen dermal substitute. To improve its stability, mechanical or chemical cross-linking was used. Despite of such process, its clinical use was restricted due to weak durability. To improve the durability of collagen matrix, we designed elastin-incorporated collagen matrix and compared its durability with conventional collagen matrix. Methods: 15mm diameter with 4mm thick collagen dermal matrix was made according to Yannas protocol by mixing 0.5% bovine collagen and chondroitin-6-sulfate followed by degassing, freeze drying, dehydrodermal cross-linking and chemical cross-linking procedure. In elastin incorporated collagen matrix, same procedure was performed by mixing elastin to previous collagen matrix in 4:1 ratio(collagen 80% elastin 20%). In comparison of the two dermal matrix in vitro tests, matrix contracture rate, strain, tensile strength, was measured and stiffness was calculated from comparative analysis. Results: In terms of matrix contracture, the elastin-incorperated added collagen dermis matrix showed 1.2 times more contraction compared to conventional collagen matrix. However, tensile strength showed 1.6 times and stiffness showed 1.6 times increase in elastin-incorporated matrix. Conclusion: Elastin incorperated collagen matrix manufactured by our team showed increased durability due to improvement in tensile strength and stiffness compared to previous collagen matrix($Integra^{(R)}$).

ON GENERALIZED TRIANGULAR MATRIX RINGS

  • Chun, Jang Ho;Park, June Won
    • East Asian mathematical journal
    • /
    • 제30권3호
    • /
    • pp.259-270
    • /
    • 2014
  • For a generalized triangular matrix ring $$T=\[\array{R\;M\\0\;S}]$$, over rings R and S having only the idempotents 0 and 1 and over an (R, S)-bimodule M, we characterize all homomorphisms ${\alpha}$'s and all ${\alpha}$-derivations of T. Some of the homomorphisms are compositions of an inner homomorphism and an extended or a twisted homomorphism.

MSPD 방법에 의한 돈육중 Carbadox와 Olaquindox 분석법 연구 (A study on determination of carbadox and olaquindox in swine tissues by matrix solid Phase disperse method")

  • 황래홍;김영수;김기근
    • 한국동물위생학회지
    • /
    • 제19권2호
    • /
    • pp.163-171
    • /
    • 1996
  • This study was carried out to determination of carbadox and olaquindox residues in swine tissues by MSPD(matrix solid phase disperse)method. The results obtained were as follows ; 1. Optimal wavelengths of UV for carbadox and olaquindox were 310 and 370nm, respectively 2. Ethyl acetate-Acetonitrile(8:2) was found to be adequate as extractant in this method. 3. The average overall recovery of carbadox at the 0.01, 0.05, and 1.0PPM spike levels was 89. 2% and that of olaquindox was 89.9%, and the detection limits were 0.5ng for carbadox and olaquindox.

  • PDF

Short-term changes of human acellular dermal matrix (Megaderm) in a mouse model

  • Kim, Yang Seok;Na, Young Cheon;Yoon, Hyun Sik;Huh, Woo Hoe;Kim, Ji Min
    • 대한두개안면성형외과학회지
    • /
    • 제20권1호
    • /
    • pp.10-16
    • /
    • 2019
  • Background: Physicians tend to overcorrect when applying the acellular dermal matrix for reconstructive option because of volume decrement problem after absorption comparing with initial volume. However, there are no studies on the exact volume decrement and absorption rate with commercial products in South Korea. To figure out absorption rate of acellular dermal matrix product in South Korea (Megaderm), authors designed this experiment. Methods: Nine mice were used and randomly divided into three groups by the time with sacrificing. The implant (Megaderm) was tailored to fit a cuboid form ($1.0cm{\times}1.0cm$ in length and width and 2.0 mm in thickness). A skin incision was made at anterior chest with blade #15 scalpel with exposing the pectoralis major muscle. As hydrated Megaderm was located upon the pectoralis major muscle, the skin was sutured with Ethilon #5-0. After the surgical procedure, each animal group was sacrificed at 4, 8, and 12 weeks, respectively, for biopsies and histological analysis of the implants. All samples were stained with routine hematoxylin and eosin staining and Masson's trichrome staining and the thickness were measured. A measurements were analyzed using Friedman test. Statistically, the correlation between thicknesses of Megaderm before and after implantation was analyzed. Results: After sacrificing the animal groups at postoperative 4, 8, 12 weeks, the mean tissue thickness values were $2.10{\pm}1.03mm$, $2.17{\pm}0.21mm$, and $2.40{\pm}0.20mm$ (p= 0.368), respectively. The remaining ratios after absorption comparing with after initial hydrated Megaderm were 82.7%, 85.4%, and 94.5%, respectively. In histopathological findings, neovascularization and density of collagenous fiber was increased with time. Conclusion: Author's hypothesis was absorption rate of implant would be increased over time. But in this experiment, there is no statistical significance between mean absorption thickness of implant and the time (p= 0.368). Also it can be affected by graft site, blood supply, and animals that were used in the experiment.

부피바카인이 류마티스 관절염환자의 섬유모세포양 활막세포 배양시 세포증식과 금속단백분해효소 생산에 미치는 실험실적 영향 (In Vitro Effects of Bupivacaine in Cell Proliferation and Matrix Metalloproteinase of Cultured Fibroblast Like Synoviocytes from Rheumatoid Arthritis from Rheumatoid Arthritis)

  • 한태형;장혜진
    • The Korean Journal of Pain
    • /
    • 제13권1호
    • /
    • pp.1-7
    • /
    • 2000
  • Background: Intraarticular local anesthetic injection has been therapeutically applied for pain control in various arthritis patients. However, little physiologic effects of local anesthetics on their tissue were known. This study was conducted to determine its effects on the cell proliferation and matrix metalloproteinases (MMP) production of cultured fibroblast like synoviocytes (FLS) derived from synovial tissues of rheumatoid arthritis patients. Methods: Bupivacaine with varying concentrations 0 (control), 0.1, 0.25, 0.5% was applied to experimental cell groups growing as monolayers in culture plates for varying durations 0 (control), 30, 90, 180 seconds in the presence and absence of interleukin-$1\beta$. Results: No statistical significances were noted in thymidine incorporation between 0, 30, 90 and 180 seconds exposure groups with 0.5% bupivacaine after 1 day and 2 days. Thymidine incorporation between 0, 0.1, 0.25, 0.5% exposure groups 1 day and 2 days after 90 seconds exposure did not show any differences. After exposure to bupivacaine, there were statistically significant increases in MMP-1 (p=0.025) and MMP-3 productions (p=0.000) of FLS in the absence of IL-$1\beta$, but no differences among the groups in the presence of IL-$1\beta$. Conclusion: We concluded that in this short-term in vitro study, bupivacaine does not have injurious effect on cultured rheumatoid arthritic joint tissues. The long-term effect cannot be known from this investigation.

  • PDF

Cranial bone regeneration according to different particle sizes and densities of demineralized dentin matrix in the rabbit model

  • Nam, Jin-Woo;Kim, Moon-Young;Han, Se-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.27.1-27.9
    • /
    • 2016
  • Background: The objective of this study was to place bone graft materials in cranial defects in a rabbit model and compare their bone regenerating ability according to the size and density of demineralized dentin matrix (DDM). Methods: We selected nine healthy male rabbits that were raised under the same conditions and that weighed about 3 kg. Two circular defects 8 mm in diameter were created in each side of the cranium. The defects were grafted with DDM using four different particle sizes and densities: 0.1 mL of 0.25- to 1.0-mm particles (group 1); 0. 2 mL of 0.25- to 1.0-mm particles (group 2); 0.1 mL of 1.0- to 2.0-mm particles (group 3); and 0.2 mL of 1.0- to 2. 0-mm particles (group 4). After 2, 4, and 8 weeks, the rabbits were sacrificed, and bone samples were evaluated by means of histologic, histomorphometric, and quantitative RT-PCR analysis. Results: In group 1, osteoblast activity and bone formation were greater than in the other three groups on histological examination. In groups 2, 3, and 4, dense connective tissue was seen around original bone even after 8 weeks. Histomorphometric analysis of representative sections in group 1 showed a higher rate of new bone formation, but the difference from the other groups was not statistically significant. RT-PCR analysis indicated a correlation between bone formation and protein (osteonectin and osteopontin) expression. Conclusions: DDM with a space between particles of $200{\mu}m$ was effective in bone formation, suggesting that materials with a small particle size could reasonably be used for bone grafting.