• Title/Summary/Keyword: 'Two-File' technique'

Search Result 88, Processing Time 0.025 seconds

Injection technique에 의한 retroseal의 변연폐쇄능에 관한 실험적 연구 (A COMPARATIVE ANALYSIS BETWEEN INJECTION-MOLDED THERMOPLASTICIZED GUTTA-PERCHA AND SILVER AMALGAM AS RETROSEAL)

  • 신영근;최기운;이인숙
    • Restorative Dentistry and Endodontics
    • /
    • 제14권2호
    • /
    • pp.31-37
    • /
    • 1989
  • The purpose of these study was to compare the sealing ability of a injection-molded thermoplasticized gutta-percha and silver amalgam as retroseal material in vitro. Sixty two upper and lower extracted human teeth with single root were randomly selected and instrumented in a conventional method with H-file. After instrumentation the root canal was obturated with gutta-percha by lateral condensation technique with AH26 and an apicoectomy was performed by beveling the root tip 45 angle. In the experimental group 1 and 2, a class I preparation was made and filled with silver amalgam or gutta-percha and in the experimental group 3 an apicoectomy only was performed. All specimens were immersed in black Indian ink, decalcified and cleared. The depth of dye penetration into the canals were evaluated by califer. The results were as follows ; 1. The experimental group 1 displayed the smallest mean dye penetration as 0.45mm. 2. The experimental group 3 displayed the greatest mean dye penetration as 0.65mm. 3. There was the difference in dye penetration between each group, but the difference was not statistically significant(P>0.05).

  • PDF

레진 계통의 근관 충전재의 제거 용이성에 대한 평가 (Evaluation of retrievability using a new soft resin based root canal filling material)

  • 신수정;이윤;박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제31권4호
    • /
    • pp.323-329
    • /
    • 2006
  • 본 실험의 목적은 새로운 레진계통의 근관 충전재로 개발된 Resilon (Epiphany, 미국 Pentron사)의 재 치료 시 제거의 용이성을 평가하는 것 이었다. 27개의 발거된 단근치를 사용하였으며, 치관부를 삭제하여 치근의 길이가 12 mm가 되도록 조정하였다. Crown-down 방법에 따라 ProFile system을 이용하여 3%의 차아염소산 나트륨 용액과 17% EDTA 용액으로 세척하면서 ISO 크기 35번, 0.04 taper ProFile이 근관장에 도달할 때까지 근관 형성을 시행하였다. 제 1군 (n = 12)은 가타퍼챠와 AH26 플러스 실러를 사용하여 열가소성 가압 충전법으로 충전 하였으며, 제 2군 (n = 15)은 같은 방법으로 제조사의 지시에 따라 Resilon으로 충전하였다. 충전 후 표본은 밀폐를 하여 습도 100%, 섭씨 37도가 유지되는 곳에 일주일간 보관하였다. 재 치료를 위하여 Gates Glidden bur와 ProFile system을 이용하여 근관 충전 물질을 제거 하였으며 이전 근관 형성 보다 한 단계 더 큰 크기의 ProFile이 근관장에 도달하는 시점까지의 시간을 기록 하였다. 최종 세척은 3% NaOCl, 17% EDTA 그리고 증류수가 사용되었다. 그 후 치아는 수직 절단하여 주사전자 현미경하에 근관의 전반적인 청결도 및 충전 물질의 잔존 정도를 치근단, 중간, 치관부로 나누어서 75배 확대상으로 평가하였다. 근관 충전 물질을 제거하는 데에 걸린 시간은 분 단위로 기록되어서 실험군 간의 차이는 Student-t 검정을 사용하여 그 유의성을 검증하였다 (오차범위 0.05 미만). 주사전자 현미경 사진은 두 명의 관찰자가 5단계로 평가하였으며 Chi-square 검정을 통해서 통계학적 유의성을 검증하였다 (오차범위 0.05 미만). 충전 후 충전재의 제거에 걸린 시간은 제 1군이 $3.25\;{\pm}\;0.32$분, 제 2 군이 $3.05\;{\pm}\;0.34$분으로 두 실험군간 통계학적으로 유의성 있는 차이가 없었다. 근관 충전재의 제거 후 근관 벽의 청결도는 두 실험 군 모두에서 치관부 1/3이 중간이나 치근단 1/3보다 우수한 결과를 보였으며 두 군 간의 차이는 없었다. 본 실험을 통해서 새로운 근관 충전 재료인 Resilon이 기존의 가타퍼챠와 실러를 사용한 충전과 비슷한 정도의 제거 용이성 및 근관 벽의 청결도를 보였음을 알 수 있었다.

네 가지 전동 Ni-Ti 파일의 danger zone에서의 근관성형력 (Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone)

  • 최석동;진명욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.446-453
    • /
    • 2004
  • 하악 대구치 근심치근의 danger zone에서 수종의 전동 니켈-티타늄 파일의 근관성형력을 근관성형 전후 치질 두께의 변화를 측정하여 평가하고자 하였다. 기구에 따라 총 40개의 하악 대구치를 10개씩 $Profile^{\circledR}$, GT Rotary file, Quantec 및 ProTaper 4개 군으로 나누고 각 치아당 2개의 근관을 straight up-and-down과 anticurvature 군으로 나누어 근단부 근관을 모두 30번 크기로 일정하게 확대하였다. 수정된 Bramante법을 사용하였으며 술전 및 술후의 근관 상아질 두께를 치수저 하방 1, 3 및 5 mm지점에서 측정, 이원변량분석법으로 통계분석하였다. 모든 군의 danger zone과 safe zone에서의 straight up-and-down 동작과 anticurvature 동작 사이에는 치근상아질 두께변화에 현저한 차이를 나타내지 않았다 (p > 0.05). ProTaper는 danger zone과 safe zone 모두에서 다른 기구에 비해 많은 량의 근관상아질 삭제를 보였으며 특히 분지부 3 mm 수준에서 현저하였다(p < 0.05).

MATLAB GUI 기반 GPS RINEX 관측 파일 생성 소프트웨어의 개발 (Development of MATLAB GUI Based Software for Generating GPS RINEX Observation File)

  • 김동욱;윤호;한덕화;장주영;기창돈;소형민;이기훈;장재규
    • 한국항행학회논문지
    • /
    • 제19권4호
    • /
    • pp.299-304
    • /
    • 2015
  • 본 논문에서는 MATLAB GUI 기반으로 개발된 GPS RINEX 관측 파일 생성 소프트웨어에 대해서 소개한다. 개발된 소프트웨어는 두 가지 데이터 생성 모드를 기반으로 기준국 혹은 동적 사용자의 실제 GPS 측정치와 유사한 L1/L2 의사거리, L1/L2 반송파 위상, 도플러 측정치를 정확하고 효율적으로 생성한다. 생성된 측정치 결과는 최종적으로 RINEX version 3.0 관측 파일로 출력된다. 본 논문에서는 소프트웨어 검증을 위해 기준국의 실측 데이터를 기반으로 측정치 바이어스, 변화율, 잡음 수준을 분석해보았다. 그 결과 개발된 소프트웨어가 실제 GPS 측정치와 RMS 약 0.7 m 수준의 바이어스 오차를 갖는 GPS 측정치를 생성함을 확인하였다.

최소경계사각형 압축 및 해슁 기법을 이용한 PDA용 공간색인 (A Spatial Index for PDA using Minimum Bounding Rectangle Compression and Hashing Techniques)

  • 김진덕
    • Spatial Information Research
    • /
    • 제10권1호
    • /
    • pp.61-76
    • /
    • 2002
  • 최근 무선 인터넷의 급속한 확산과 휴대장치 기술의 발전으로 PDA를 이용한 모바일 지도 서비스가 보편화되고 있다. 지도 서비스를 위한 공간 데이터는 용량이 크고,공간 연산 또한 비용이 매우 간 반면 PDA는 저장 장치의 용량이 작고 프로세서의 성능이 낮다 따라서 PDA용 공간 색인은 작은 규모이면서도 총간 연산의 여과 효율이 좋아야 한다 이 논문에서는 저용량, 낮은 성능의 PDA에 적합한 총간 색인 구조인 MHF를 제안한다. MHF는 간단한 구조로 공간 효율성을 높이면서, 직접 탐색 방법인 해슁을 도입하여 검색 효율을 높였다. 그러고 2차인 총간 색인의 80%이상을 차지하는 치소 경계사자형(MBR) 정보를 압축하기 위한 HMBR을 제안한다. HMBR은 MBR의 표현량을 약1/3으로 단축함에도 불구하고, 공간 데이터의 대부분을 차지하는 작은 객체인 경우에는 정량화에 의한 정보 손실이 전혀 없어 여과 효율이 좋다. 실험 결과 색인의 크기, MBR 비교 연산 횟수, 여과 효율, 공간 연산의 수행 시간 측면에서 제안한 HMBR을 이용한 MHF 공간 색인이 PDA에 가장 적합한 구조임을 보여주었다.

  • PDF

하이브리드 플래시-디스크 저장장치용 Flash Translation Layer의 성능 개선을 위한 순차패턴 마이닝 기반 2단계 프리패칭 기법 (Improving Flash Translation Layer for Hybrid Flash-Disk Storage through Sequential Pattern Mining based 2-Level Prefetching Technique)

  • 장재영;윤언근;김한준
    • 한국전자거래학회지
    • /
    • 제15권4호
    • /
    • pp.101-121
    • /
    • 2010
  • 본 논문은 플래시 메모리와 하드디스크로 구성되는 하이브리드 저장장치의 성능을 높이기 위한 프리패칭 기법을 제안한다. 하이브리드 저장장치에 포함된 플래시 메모리는 하드디스크에 비해 쓰기/읽기 연산 속도가 상대적으로 빠르기 때문에 이를 캐시 공간처럼 활용하여 성능을 높일 수 있다. 프리패칭을 위한 기본 전략은 순차패턴 마이닝을 이용하는 것이며, 이를 이용하면 시간적 흐름을 가지는 과거 객체 참조열로부터 반복되는 객체 접근 패턴을 추출할 수 있다. 프리패칭 기법을 사용하여 하이브리드 저장장치의 성능을 최대화하기 위하여 본 논문은 두 가지 방법을 사용하였다. 첫 번째는 플래시 메모리 매핑을 위하여 기존의 FAST 알고리즘을 개선하였고, 두 번째는 제한된 플래시 메모리의 공간을 효율적으로 사용하기 위하여 프리패칭 단위로 파일 수준과 블록 수준을 동시에 고려하였다. 제안 기법의 효용성을 평가하기 위해 참조 지역성을 가지는 합성 데이터와 UCC 데이터를 활용하여 실험을 실시하여 제안된 방법의 우수성을 증명하였다.

수산화칼슘 제제의 제거 방법이 치근단 누출에 미치는 영향에 대한 전기화학적 연구 (Effect of two different calcium hydroxide paste removal techniques on apical leakage: an electrochemical study)

  • 박찬제;전경아;권호범
    • Restorative Dentistry and Endodontics
    • /
    • 제31권3호
    • /
    • pp.186-191
    • /
    • 2006
  • 본 연구의 목적은 근관내 약제로 사용되는 수산화칼슘의 제거방법이 근관충전 후 치근단 미세누출에 미치는 영향을 알아보기 위함이다. 70개의 발거된 단근치를 엔진구동형 ProFile로 근관형성한 후 수용성 수산화칼슘 제제를 1주일간 적용하고 두 군으로 나누어 각기 다른 방법으로 제거하였다. A군은 NaOCl로 근관세정만을 시행하였으며, B군은 근관형성 시 사용된 file보다 한 단계 큰 크기의 ProFile을사용하여 근관을 재형성한 후 NaOCl로 세척하였다. 근관충전 후 전기화학적 방법으로 24일 동안 치근단 누출을 측정, 비교하였다. 본 연구의 결과 수산화 칼슘 제거를 위한 두가지 방법은 근관충전후 치근단 미세누출에 있어서 차이가 없음을 알 수 있었다.

각종 근관충전법의 치근단 폐쇄효과에 관한 연구 (AN EXPERIMENTAL STUDY ON THE SEALING ABILITY OF DIFFERENT ROOT CANAL OBTURATION METHODS)

  • 허승면;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.143-154
    • /
    • 1991
  • The purpose of this study was to evaluate the sealing ability of five obturation methods in conjunction with sealer. Fifty extracted upper and lower anterior teeth were selected and the access cavities were prepared lingually with a round bur. The working length was determined with a #15K file, and the root canals were instrumented with a #40K file 1mm short of the apical foramen. The apical third of root canal was flared by step-back technique and the coronal two thirds of root canal using #2 - 3 Gates Glidden drills. And then, the teeth were randomly assigned to five groups of 10 teeth each. A thin coat of Tubliseal was placed into the canal into the canal using the # 35 reamer and the canals were filled by lateral condensation, vertical condensation, ultrasonic activated lateral condensation, ULTRAFIL injecting, and McSpadden compaction methods. All teeth were stored in 100 % relative humidity at 31c for 48 hours. The roots were suspended in 2 % methylene blue solution for 48 hours, left to dry for 24 hours and then, half side of root was removed longitudinally using the fissure bur. A Boley gauge wes used to measure the distance, to the nearest 0.1mm, from the apical foramen to the most coronal level of dye penetration. The measurement of dye penetration was statistically compared by Duncan's multiple range test The results were as follows 1. Ultrasonic group showed the best sealing ability among the all experimental groups, but there were statistically no significant difference in the sealing ability between ultrasonic group and vertical condensation group. 2. There were no statistically significant difference in the sealing ability among the lateral, vertical, and ultrasonic groups. 3. McSpadden group showed the worst sealing ability among the all exprimental groups.

  • PDF

혐기성세균모델을 이용한 봉함제(Sealer)의 미세누출에 관한 연구 (LEAKAGE EVALUATION OF SEVERAL SEALERS USING ANAEROBIC BACTERIAL LEAKAGE MODEL)

  • 배용규;오태석;윤수한
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.235-242
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate the sealing ability of three sealers(Sealapex, Pulp canal sealer, AH26) used with continuous wave method using an anaerobic bacterial leakage model. 53 extracted human teeth with straight and single canals were prepared with crown-down pressureless technique using .04, .06 taper Profile(Maillefer, Swiss). Master apical file was maintained as #35 K-file. All canals of the experimental teeth were obturated with continuous wave method using System B(Analytic technology, U.S.A.) The teeth were randomly divided into three experimental groups of 15 and two control groups of 4. Experimental group 1 was obturated with Sealapex and group 2 with Pulp canal sealer, and group 3 with AH26. A dual chamber anaerobic bacterial leakage model was assembled. Brain heart infusion with yeast extract, hemin, menadion, and the chromogenic indicator bromocresol purple was used as the culture broth for Fusobacterium nucleatum(VPI 10197), The specimens were incubated in anaerobic chamber at $37^{\circ}C$ and were observed every 2 to 3 clays, The coronal leakage was evaluated through the color change of culture broth in lower chamber for 60 days. The results were as follows: 1. The incidence of bacterial leakage in group 1 (Sealapex group was 80%, 53% in group 2 (Pulp canal sealer), 27% in group 3 (AH26). 2. There were statistically significant differences in leakage scores between group 1 and group 2, and between group 1 and group 3, respectively. (P<0.05) 3. There was no significantly difference in leakage score between group 2 and group 3. (P>0 05)

  • PDF

개방 근첨 치아의 근관 충전방법에 따른 치근단 폐쇄효과에 관한 연구 (THE SEALING ABILITY OF OBTURATION TECHNIQUES IN OPEN APEX)

  • 소현;최호영;최경규;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.435-445
    • /
    • 2000
  • The purpose of this study was to compare the leakage of four different obturation techniques in conjunction with immediate apical barrier of ${\beta}$-tricalcium phosphate(TCP) in teeth with open apex. Eighty single-rooted human premolar teeth were prepared and sectioned horizontally, so maximum diameter in apex was 4mm. Apical defects that were similar to open apex, were created with #1/2 round bur and SF104R bur. The apical foramen were opened to a size 80 file extended 3mm beyond the apex. The teeth were placed into the oasis block soaked saline to simulate periapical tissue often associated with pulpless teeth and received apical barriers consisting of TCP followed by obturation using lateral condensation technique, vertical condensation technique, continuous wave technique and thermoplasticized gutta-percha injection technique. Two unobturated teeth served as positive and negative controls. Teeth were immersed in resorcinol-formaldehyde resin for S days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were then sectioned horizontally at 1.5mm(level 1), 2.5mm(level 2) and 3.5mm(level 3) from the apex, and examined under a stereomicroscope at ${\times}40$ magnification. The photographs were taken at ${\times}40$ magnification of the filling in each level and scanned. The leakage length in tooth/resin interface was measured at each of the three levels. Each ratio of leakage was obtained by calculating the ratio of the leakage length of canal wall infiltrated with resin to the total length of the canal and was analyzed statistically(One-way ANOVA and Scheffe test). The result were as follows : 1. At the level 1, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), but there was statistically significant(p<0.05). 2. At the level 2, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), and the most leakage in the continuous wave technique group(group 3). There was statistically significant difference between the thermoplasticized gutta-percha injection technique group and the continuous wave technique group(p<0.05). 3. At the level 3, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), but there were no statistically significant differences between other groups(p>0.05). These results suggest that thermoplasticized gutta-percha injection technique which had 1mm apical gutta-percha matrix after the formation of TCP apical barrier, can demonstrate favorable apical sealing.

  • PDF