• Title/Summary/Keyword: % RSD

Search Result 533, Processing Time 0.03 seconds

Ultra-trace Arsenic Determination in Urine and Whole Blood Samples by Flow Injection-Hydride Generation Atomic Absorption Spectrometry after Preconcentration and Speciation Based on Dispersive Liquid-Liquid Microextraction

  • Shirkhanloo, Hamid;Rouhollahi, Ahmad;Mousavi, Hassan Zavvar
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.11
    • /
    • pp.3923-3927
    • /
    • 2011
  • A noble method for pre-concentration and speciation of ultra trace As (III) and As (V) in urine and whole blood samples based on dispersive liquid-liquid microextraction (DLLME) has been developed. In this method, As (III) was complexed with ammonium pyrrolidine dithiocarbamate at pH = 4 and Then, As (III) was extracted into the ionic liquid (IL). Finally, As (III) was back-extracted from the IL with hydrochloric acid (HCl) and its concentration was determined by flow injection coupled with hydride generation atomic absorption spectrometry (FI-HGAAS). Total amount of arsenic was determined by reducing As (V) to As (III) with potassium iodide (KI) and ascorbic acid in HCl solution and then, As (V) was calculated by the subtracting the total arsenic and As (III) content. Under the optimum conditions, for 5-15 mL of blood and urine samples, the detection limit ($3{\sigma}$) and linear range were achieved 5 ng $L^{-1}$ and 0.02-10 ${\mu}g\;L^{-1}$, respectively. The method was applied successfully to the speciation and determination of As (III) and As (V) in biological samples of multiple sclerosis patients with suitable precision results (RSD < 5%). Validation of the methodology was performed by the standard reference material (CRM).

A Comparison of Analytical Methods for the Content and Purity of Cefradine

  • Hyun, Myung-Ho;Jeong, Euh-Duck;Shin, Min-Seob;Jin, Jong-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.1185-1189
    • /
    • 2008
  • Two HPLC methods such as cefadroxil and cefalexin methods were compared in their performance for the quantitative analysis of the content and purity of $\beta$ -lactamic antibiotic, cefradine, for six bulk drug samples. Between the two methods, the cefadroxil method prescribed by the European Pharmacopoeia (EP) for the determination of impurities in cefradoxil was superior to the cefalexin method prescribed by the EP and by the United States Pharmacopeia (USP) for the determination of cefalexin impurity in cefradine in terms of the greater stability of the chromatogram baselines and the higher precision, i.e., the lower % relative standard deviation (RSD). Based on the comparison of the two HPLC methods, the cefadroxil method was recommended to replace the TLC method, which has been prescribed by the EP as the official method for determination of extraneous impurities in cefradine.

Analysis of Haloacetonitriles in Drinking Water Using Headspace-SPME Technique with GC-MS (Handspace Solid Phase Microextraction 방법에 의한 HANs 분석에 관한 연구)

  • Cho, Deok-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.628-637
    • /
    • 2004
  • In many drinking water treatment plants, chlorination process is one of the main techniques used for the disinfection of water. This disinfecting treatment leads to the formation of disinfection by-products (DBPs) such as haloacetonitriles (HANs), trihalomethanes (THMs), haloacetic acids (HAAs). In this study, headspace-solid phase microextraction (HS- SPME) technique was applied for the analysis of HANs in drinking water. The effects of experimental parameters such as selection of SPME fiber, the addition of salts, magnetic stirring, extraction temperature, extraction time and desorption time on the analysis were investigated. Analytical parameters such as linearity, repeatability and detection limits were also evaluated. The $50/30{\mu}m$-divinylbenzene/carboxen/polydimethylsiloxane fiber, extraction time of 30 minutes, extraction temperature of $20^{\circ}C$ and desorption time of 1 minute at $260^{\circ}C$ were the optimal experimental conditions for the analysis of HANs. The correlation coefficients ($r^2$) for HANs was 0.9979~0.9991, respectively. The relative standard deviations (%RSD) for HANs was 2.3~7.6%, respectively. Detection limits (LDs) for HANs was $0.01{\sim}0.5{\mu}g/L$, respectively.

Immobilization of the Thenoyltrifluoroacetone on Sodium Dodecyl Sulfate Modified Magnetite Nanoparticles for Magnetic Solid Phase Extraction of Pb (II) from Water Samples

  • Sadeghi, Meysam;Yekta, Sina;Babanezhad, Esmaeil
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.636-647
    • /
    • 2016
  • Magnetite nanoparticles ($Fe_3O_4$ NPs) were synthesized by co-precipitating method under optimized condition. The $Fe_3O_4$ NPs coated with sodium dodecyl sulfate-thenoyltrifluoroacetone ($Fe_3O_4$ NPs-SDS-TTFA) were then exerted as the magnetic solid phase extraction (MSPE) adsorbent for the extraction process prior to introducing to a flame atomic adsorption spectrometry (FAAS). The synthesized $Fe_3O_4$ NPs-SDS-TTFA were applied for the extraction of Pb(II) ions from different water samples. The characterization studies of nanoparticles were performed via scanning electron microscopy-energy dispersive micro-analysis (SEM-EDAX), X-ray diffraction (XRD) and vibrating sample magnetometer (VSM) techniques. The substantial parameters affecting the extraction efficiency were surveyed and optimized. A dynamic linear range (DLR) of $10-400{\mu}g\;L^{-1}$ was obtained and the limit of detection (LOD, n=7) and relative standard deviation (RSD%, n= 6, $C=20{\mu}g\;L^{-1}$) were found to be $2.3{\mu}g\;L^{-1}$ and 1.9%, respectively. According to the results, the proposed method successfully applied for the extraction of Pb(II) ions from different environmental water samples and satisfactory results achieved.

Solid Phase Extraction of Trace Cu(II), Mn(II), Pb(II) and Zn(II) in Water Samples with Pulverized Silica-salen(NEt2)2

  • Kim, Young-Sang;In, Gyo;Choi, Jong-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.10
    • /
    • pp.1557-1561
    • /
    • 2006
  • The use of chemically modified silica-salen$(NEt_2)_2$ was studied for the separation and concentration of the metal ions from an aqueous solution by a solid phase extraction. After the salen(NEt2)2 was synthesized, it was chemically bonded to silica gel by a diazonium coupling reaction. The adsorption capacities and binding constants were obtained with respect to Cu(II), Mn(II), Pb(II) and Zn(II) by a graphical method. Some experimental conditions were optimized for the determination of the trace elements. After the silica-salen(NEt2)2 was pulverized in a sample solution of which the pH was adjusted, the solution was stirred to pre-concentrate the metal ions. The metal ions adsorbed were desorbed with nitric acid solution. And the concentrated analytes were determined by a flame AAS. The method proposed here was so rarely influenced by a sample matrix that the procedure was applied to 3 types of water samples. The reproducible results of less than 10% RSD were obtained at the concentration level of ca. 100 ng/mL and the recoveries of 95-109% were obtained in the spiked samples in which given amounts of analytes were added.

Development of a Multi - channel Detector for Capillary Electrophoresis System (모세관 전기영동 장치용 Photodiode Array 다채널 검출기의 개발에 관한 연구)

  • Hong, Seung Guk;Kim, Hai-Dong
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.96-104
    • /
    • 1998
  • A photodiode array multichannel detector system for capillary electrophoresis was developed. The photodiode array detector for capillary electrophoresis (CE-PDA) has 1024 photodetectors and can analyze sample by measuring UV/VIS absorption spectrum in 275~675 nm wavelength range. The CE-PDA instrument can get a spectrum in 30 ms during sample separation and can be programmed by a PC to control various experimental conditions required for sample analysis. The performance of the multichannel CE-PDA instrument was tested using L-ascorbic acid and alizarin yellow GG mixture. The reproducibility test of the CE-PDA system showed 5.6% RSD.

  • PDF

Research for the Analytical Method of Various Pesticides in Raw Milk by Gas Chromatography-Mass Spectrometry (GC/MSD를 사용한 원유 내 잔류농약의 분석법 연구)

  • Oh, N.S.;Shin, Y.K.;Baick, S.C.
    • Food Science of Animal Resources
    • /
    • v.29 no.4
    • /
    • pp.482-486
    • /
    • 2009
  • The aim of this study was to optimize a simple, fast, and economical analysis procedure for the determination of 16 different pesticides in raw milk via GC/MSD. Analyses were performed via gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode (GC/MSD-SIM) using Pentachloronitrobenzene as the internal standard. The modified sample preparation methodology was based on the Pesticide Analytical Manual (PAM) of the FDA concerning fat extraction, ACN-ether partitioning, and clean-up of the Sep-Pak florisil cartridge. The modified methodology for the determination of the 16 pesticides was validated. The range of LOQs of the 16 pesticides was likely three times lower than their Maximum Residence Levels (MRLs). The recoveries of most of the pesticides were acceptable at the fortification levels of 0.5 and 1.0 ${\mu}g/mL$ and their RSD (%) level was less than 20%. None of the 16 pesticides were detected in the selected raw milk samples.

Investigation of Water Safety in Non-treated Drinking Water with Trace Toxic Metals

  • Ly, Suw Young;Kim, Dae Hong;Lee, Ga Eun
    • Toxicological Research
    • /
    • v.29 no.3
    • /
    • pp.211-215
    • /
    • 2013
  • The trace toxic metal copper was assayed using mercury immobilized on a carbon nanotube electrode (MCW), with a graphite counter and a reference electrode. In this study, a macro-scale convection motor was interfaced with a MCW three-electrode system, in which a handmade MCW was optimized using cyclic- and square-wave stripping voltammetry. An analytical electrolyte for tap water was used instead of an expensive acid or base ionic solution. Under these conditions, optimum parameters were 0.09 V amplitude, 40 Hz frequency, 0.01 V incremental potential, and a 60-s accumulation time. A diagnostic working curve was obtained from 50.0 to 350 ${\mu}g/L$. At a constant Cu(II) concentration of 10.0 ${\mu}g/L$, the statistical relative standard deviation was 1.78% (RSD, n = 15), the analytical accumulation time was only 60 s, and the analytical detection limit approached 4.6 ${\mu}g/L$ (signal/noise = 3). The results were applied to non-treated drinking water. The content of the analyzed copper using 9.0 and 4.0 ${\mu}g/L$ standards were 8.68 ${\mu}g/L$ and 3.96 ${\mu}g/L$; statistical values $R^2$ = 0.9987 and $R^2$ = 0.9534, respectively. This method is applicable to biological diagnostics or food surveys.

Analysis of Amadori Compounds in Tobacco Leaf by LC-MS/MS (LC-MS/MS를 이용한 담배 중 Amadori Compounds의 분석)

  • Min, Hye-Jeong;Kim, Young-Hoi;Lee, Jeong-Min;Jang, Gi-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.33 no.1
    • /
    • pp.21-27
    • /
    • 2011
  • Amadori compounds(1-deoxy-1-amino-2-ketoses) are important precursors of color, flavor and aroma produced in foods. Amadori compounds occur naturally in tobacco. The contribution of amadori compounds to smoke quality has been (of) interest because of their roles of the Maillard reaction in the leaf chemistry. The amounts of these compound in tobacco are affected by the processes of aging, drying and storage conditions. In this study, eight compounds were chemically synthesized because amadori compounds (have not been sold commercially these days.) were not available for obtaining commercially. The aim of this study was to develop the analytical method of amadori compounds in tobacco leaf by the liquid chromatography mass spectrometry using triple quadrupole analyzer(LC-MS/MS). This method was simple, rapid, selective and sensitive, and eight amadori compounds were simultaneously and quantitatively analyzed within 20 minutes. This method showed excellent accuracy and precision. Recovery rates of amadori compounds ranged from 86% to 102%, with relative standard deviation(RSD) ranged from 2.6% to 5.9%. This method was applied to analysis of amadori compounds contents of tobacco leaves in different varieties. Furthermore, it was expected that the method could be extended to the analysis of other amadori compounds.

Development of Analytical Method of Biotin in Complex Drugs and Dietary Supplements Using HPLC-UV

  • Huh, Yoon-Young;Kang, Yun-Pyo;Choi, Yong-Seok;Park, Jeong-Hill;Kwon, Sung-Won
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.1
    • /
    • pp.25-30
    • /
    • 2011
  • Recently, Korean Food and Drug Administration (KFDA) has focused on developing quality control guidelines for all commercial products in Korea to enforce regulations, improve the quality control, and protect consumers by developing prevalently used and efficient analytical tools to determine and quantify target compounds. Because the Korean Pharmacopeia (KP) presents microbiological assays for biotin, which is laborious and time-consuming, this study is focused on applying HPLC-UV to detect and quantify biotin in complex drugs and dietary supplements like multi-vitamin. Biotin in complex drugs was extracted from methanol and analyzed using mobile phase with 10 mM potassium phosphate (monobasic, pH=3.0) in distilled water and acetonitrile. Gradient condition was used to successfully detect and quantify biotin within 20 minutes. Validation result for linearity was significant that average $r^2$ was 0.999 (n=3) and its relative standard deviation (RSD) was 0.0578% which was less than 2%. Using this method, quantification of biotin in complex drugs was completed successfully and recovery tests were finished that recovery percentage greater than 95% with relative standard deviation less than 2%.