• Title/Summary/Keyword: $Z_2$

Search Result 7,099, Processing Time 0.038 seconds

The Investigation Image-guided Radiation Therapy of Bladder Cancer Patients (방광암 환자의 영상유도 방사선치료에 관한 고찰)

  • Bae, Seong-Soo;Bae, Sun-Myoung;Kim, Jin-San;Kang, Tae-Young;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.39-43
    • /
    • 2012
  • Purpose: In hospital image-guided radiation therapy in patients with bladder cancer to enhance the reproducibility of the appropriate amount, depending on the patient's condition, and image-guided injection of saline system (On-Board Imager system, OBI, VARIAN, USA) three of the Cone-Beam CT dimensional matching (3D-3D matching) to be the treatment. In this study, the treatment of patients with bladder cancer at Cone-Beam CT image obtained through the analysis of the bones based matching and matching based on the bladder to learn about the differences, the bladder's volume change injected saline solution by looking at the bladder for the treatment of patients with a more appropriate image matching is to assess how the discussion. Materials and Methods: At our hospital from January 2009 to April 2010 admitted for radiation therapy patients, 7 patients with bladder cancer using a Folly catheter of residual urine in the bladder after removing the amount determined according to individual patient enough to inject saline CT-Sim was designed after the treatment plan. After that, using OBI before treatment to confirm position with Cone-Beam CT scan was physician in charge of matching was performed in all patients. CBCT images using a total of 45 bones, bladder, based on image matching and image matching based on the difference were analyzed. In addition, changes in bladder volume of Eclipse (version 8.0, VARIAN, USA) persuaded through. Results: Bones, one based image matching based on the bladder and re-matching the X axis is the difference between the average $3{\pm}2mm$, Y axis, $1.8{\pm}1.3mm$, Z-axis travel distance is $2.3{\pm}1.7mm$ and the overall $4.8{\pm}2.0mm$, respectively. The volume of the bladder compared to the baseline showed a difference of $4.03{\pm}3.97%$. Conclusion: Anatomical location and nature of the bladder due to internal movement of the bones, even after matching with the image of the bladder occurred in different locations. In addition, the volume of saline-filled bladder showed up the difference between the 4.03 percent, but matched in both images to be included in the planned volumes were able to confirm. Thus, after injection of saline into the bladder base by providing a more accurate image matching will be able to conduct therapy.

  • PDF

An Inter-Laboratory Comparison Study on Chlorophyll a Determination in Seawater (해수 중 엽록소 a 측정방법에 대한 실험실 간 비교연구)

  • Moon, Cho-Rong;Kang, Dong-Jin;Park, Mi-Ok;Noh, Jae Hoon;Yoo, In-Jae;Moon, Jeong-Eon;Shin, Kyung-Hoon;Kim, Yun Sook;Choi, Joong-Ki;Suh, Young Sang
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.1
    • /
    • pp.76-87
    • /
    • 2014
  • Chlorophyll a in seawater which is an indicator of phytoplankton biomass and primary production is determined by High Performance Liquid Chromatography (HPLC), Fluorometry and Spectrophotometry. In this study, various methods for chlorophyll a determination in seawater are compared using in situ seawater samples from Korean seas. Three inter-laboratory comparison campaigns were carried out using chlorophyll a standard samples (R0) and in situ seawater samples, collected from the East China Sea (R1) and the East Sea (R2). 6 laboratories by HPLC methods, 4 laboratories by fluorometry, and 3 laboratories by spectrophotometry participated. Precisions, defined as the coefficient of variation (CV) were within 9% in standard samples, 0.8~20% (average: 6.1%) in R1, 4~21% (average: 13.2%) in R2. Discrepancy in three methods was approximately 20% within the range of the sample homogeneity intended the laboratory precision (R1: 8%, R2: 15%). The discrepancy in laboratories was greater than the discrepancy in methods. The chlorophyll a concentrations can be produced within 20% discrepancy in spite of using different methods. It is recommended to consider this 20% discrepancy when using the chlorophyll a data produced by different laboratories and different methods.

A Study on the Precise End-Point Detection in Titration by Using the Phase Angle Measurements (위상각 측정에 의한 적정의 정확한 종말점 검출법에 관한 연구)

  • Park, Byung-Bin;Shin, Ho-Sang;Lee, Han-Hyoung
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.290-298
    • /
    • 1999
  • A study on the application of impedance phase angle for redox titration, acid-base titration, chelate titration and precipitation titration has been carried out. A constant alternating current was passed between two platinum electrodes. One of them was a polarizable micro-electrode of $0.1cm^2$ or $0.026cm^2$ surface area and the other a non-polarizable large electrode of $1cm^2$ surface area dipped in the solution to be titrated. The impedance and the phase angle of the titration cell were measured with lock-in amplifier to obtain well behaved titration curve respectively. In titration of oxalic acid vs. potassium permanganate, the end-point was obtained successfully from the phase angle titration curve. In this experiment, the concentration of 0.0005 M to 0.05 M, the current of $50{\mu}A$ and the frequency of near 50 Hz were used. In titration of phosphoric acid vs. sodium hydroxide, the first end-point was obtained successfully on the optimum experimental condition of 0.001 M concentration, $50{\mu}A$ current and 25~97 Hz frequency. However, the end-point in titration of cupric sulfate vs. disodium-EDTA couldn't be obtained clearly. The end-point was obtained with the out-of-phase impedance curve on the experimental condition of 0.01 M concentration, $100{\mu}A$ current, 5~35 Hz frequency range. In titration of sodium chloride vs. silver nitrate, the end-point was obtained successfully on the experimental condition of 0.1 M concentration, $100{\mu}A$ current and 5~47 Hz frequency range. This study showed that the impedance phase angle was applicable for the detection of the end-points in redox titration curve, acid-base titration curve, chelate titration curve and precipitation titration curve.

  • PDF

Community Structure of Forest Vegetation in Mt. Geumsusan belong to Woraksan National Park (월악산국립공원 금수산 산림식생의 군집구조)

  • Kim, Ho-Jin;Shin, Jae-Kwon;Lee, Cheol-Ho;Yun, Chung-Weon
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.2
    • /
    • pp.202-219
    • /
    • 2017
  • The purpose of this study was to analyze the community structure of forest vegetation in Mt. Geumsusan belong to Woraksan National Park for providing basic information of ecological management. Data were collected by 41 plots from June to November in 2016 using Z-M phytosociology method, which was analyzed with vegetation types, mean importance value and coincidence method. As the results, the forest vegetation was classified into Quercus mongolica community group including Cornus controversa community, Castanea crenata community(Vegetation unit 3), Quercus variabilis community(Vegetation unit 4) and Q. mongolica community(Vegetation unit 5). C. controversa community was divided into two groups such as Ulmus davidiana var. japonica group(Vegetation unit 1) and Parthenocissus tricuspidata group(Vegetation unit 2). Mean importance percentage of vegetation unit 1 was showing Fraxinus rhynchophylla 14.9%, Morus bombycis 8.7% and Acer pictum subsp. mono 8.3%, that of unit 2 was Larix kaempferi 23.2%, C. controversa 20.1% and P. tricuspidata 6.5%, that of unit 3 was Q. mongolica 15.8%, C. crenata 13.4% and F. rhynchophylla 9.8%, that of unit 4 was Q. mongolica 26.6%, Q. variabilis 20.8% and Pinus densiflora 16.7%, that of unit 5 was Q. mongolica 48.3%, Styrax obassia 7.5%, F. rhynchophylla 5.3% in the order, respectively. Each vegetation unit was classified with dependance on environmental factors as 700m of altitude, $20^{\circ}$ of slope degree, middle slope of topography, 20% of bare rock, 30 taxa of present species, 80% of tree layer coverage rate and 20m of tree layer height. In conclusion, it was preferentially considered that development of peculiar and specific management methods with vegetation unit classified above should be needed for ecological and sustainable forest vegetation management.

Growing Density and Cavity Volume of Container Influence Major Temperate Broad-leaved Tree Species of Physiological Characteristics in Nursery Stage (용기의 생육밀도와 용적에 따른 온대 주요 활엽수의 생리 특성 변화)

  • Cho, Min Seok;Jeong, Jaeyeob;Yang, A-Ram
    • Journal of Korean Society of Forest Science
    • /
    • v.106 no.1
    • /
    • pp.40-53
    • /
    • 2017
  • The purpose of this study was to evaluate the effects of container types on physiological characteristics of Zelkova serrata, Fraxinus rhynchophylla and Quercus serrata in the container nursery stage. We used 16 container types [4 growing densities (100, 144, 196 and $256\;seedlings/m^2$)${\times}4$ cavity volumes (460, 380, 300 and $220cm^3/cavity$)] and performed two-way ANOVA to test the differences in photosynthesis, photochemical efficiency and chlorophyll content among container types. Also, multiple regression analysis was conducted to correlate container dimensions with photosynthetic rate. Container types had a strong influence on photosynthesis of three species seedlings. Growing densities and cavity volumes had a significant interaction effect on photosynthetic rate, water use efficiency, stomatal conductance and chlorophyll contents except stomatal conductance of Q. serrata. In all three species, however, interactions between the two factors of container type were not found with regard to photochemical efficiency. Growing density was negatively correlated with photosynthetic rate of F rhynchophylla and Q. serrata, while cavity volumes positively affected on those of three species seedlings. The range of optimal container types was determined by multiple regression analysis based on photosynthetic rate. Consequently, optimal growing density and cavity volume of container by each tree species were found to be approximately $160{\sim}210\;seedlings/m^2$ and $430{\sim}460cm^3/cavity$ for Z. serrata, $130{\sim}150\;seedlings/m^2$ and $390{\sim}440cm^3/cavity$ for F. rhynchophylla and $130{\sim}170\;seedlings/m2$ and $420{\sim}460cm^3/cavity$ for Q. serrata, respectively. Application of adequate container will induce higher quality seedling production in nursery stage, which will also increase seedling growth in plantation stage.

Effects of Primisulfuron and Terbufos on Growth and Acetolactate Synthase Activity in Several Corn Cultivars (Primisulfuron과 살충제(殺蟲劑) Terbufos의 상호작용(相互作用)이 옥수수품종(品種)의 생장(生長) 및 Acetolactate Synthase산소(酸素) 활성(活性)에 미치는 영향(影響))

  • Piao, R.Z.;Pyon, J.Y.;Roh, S.W.;Ahn, B.S.
    • Korean Journal of Weed Science
    • /
    • v.18 no.2
    • /
    • pp.171-178
    • /
    • 1998
  • Growth response and acetolactate synthase(ALS) activity were examined to determine the resistance of corn cultivars to primisulfuron when primisulfuron and/ or insecticide Terbufos were applied. Pioneer 3571 IR showed resistance to primisulfuron regardless of Terbufos treatment, but Pioneer 3571 was greatly injured with primisulfuron plus Terbufos treatment. Suwon 118 was relatively tolerant to primisulfuron compared to Chalok 2, but crop injury was occurred at both cultivars by primisulfuron plus Terbufos treatment. ALS activity at Pioneer 3751 IR was very high in primisulfuron and/ or Terbufos treatment. Suwon 118 also showed higher ALS activity compared to Pioneer 3751 and Chalok 2, but ALS activities were greatly decreased by primisulfuron plus Terbufos treatment at Suwon 118 and Chalok 2. The $I_{50}$ concentration for 50% inhibition of the ALS enzyme was 10.0, 0.06, 7.75, and 0.04${\mu}M$ for Pioneer 3751 IR, Pioneer 3751, Suwon 118, and Chalok 2, respectively. Consequently, resistance of corn cultivars to primisulfuron was significantly related to ALS activity. Crop injury and lower ALS activity were recognized in susceptible corn cultivars by primisulfuron plus Terbufos treatment.

  • PDF

Characteristics of Fish Community and Habitat Aspects of Cold-water Fish Speciesin the Bangtaecheon (Stream), Korea (방태천의 어류군집 특성 및 냉수성 어류의 서식양상)

  • Kwang-Seek Choi;Mee-Sook Han;Myeong-Hun Ko
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.6
    • /
    • pp.603-614
    • /
    • 2022
  • This study investigated the characteristics of fish communities in the Bangtaecheon Stream in Korea from April to October 2020. The survey collected 4,640 fish of 26 species in 9 families from 11 survey stations. The dominant and subdominant species were Rhynchocypris kumgangensis(relative abundance at 31.5%) and Zacco koreanus(27.8%), respectively. The next most abundant species were Ladislavia taczanowskii(15.9%), Pungtungia herzi(4.0%), Brachymystax lenok tsinlingensis(3.7%), Microphysogobio longidorsalis(2.4%), and Zacco platypus(2.3%). Among the collected fish species, 17 (65.4%) were Korean endemic species, 4 (15.4%), including Acheilognathus signifer, Pseudopungtungia tenuicorpa, Gobiobotia brevibarba, and B. l. tsinlingensis,were class II endangered wildlife as designated by the Ministry of Environment, and 1 species, Hemibarbus mylodon, was a natural monument. Moreover, two landlocked species (B. l. tsinlingensisand C. koreanus) were also collected. Additionally, four cold-water species (R. kumgangensis, L. taczanowskii, B. l. tsinlingensis,and Cottus koreanus) were collected, and all of them mainly inhabited the upper and middle streams. Fish community analysis showed a tendency for dominance and uniformity to decrease and abundance and diversity to increase from upstream to downstream and that the community structure was divided into upstream and downstream groups. The river health was rated as excellent (9 stations) and good (2 stations). Compared to the previous studies, three species (Carassius auratus, Leiocassis ussuriensis,and Siniperca scherzeri) appeared in the past but did not appear in this survey, and three species (Opsariichthys uncirostris amurensis, Microphysogobio yaluensis,and Orthrias nudus) that did not appear in the past appeared in this survey. Bangtaecheon Steam is well-preserved, and climate-sensitive species, endangered wildlife, and natural monuments inhabit the stream. Therefore, continuous attention and systematic conservation measures are required.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Effect of Flywheel Weight on the Vibration of Diesel Engine (플라이휠 중량(重量)이 디젤 기관(機關)의 진동(振動)에 미치는 영향(影響))

  • Myung, Byung Soo;Kim, Sung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.20 no.2
    • /
    • pp.167-180
    • /
    • 1993
  • Most of small size diesel engines are widely used with the same size and weight flywheel in the levels of 6.0kW and 7.5kW. This study was conducted to obtain basic data which affect the engine performance of the power tiller. The flywheel weight was considered as a major factor in this research. Basically, fuel consumption ratio, motoring loss, torque, vibration and mechanical efficiency of the engine were measured and analyzed on four levels of flywheel weight, 32.2, 29.4, 26.2 and $24.2kg_f$, respectively. Results were obtained as follows: 1. The weights of flywheel were $23.7kg_f$ from design program of JSME and $24.5kg_f$ from ASME and SAE design criteria. Therefore, the flywheel weight of $32.2kg_f$ might be reduced about $8kg_f$ in 7.5kW engine. 2. The rated outputs of 6.0kW and 7.5kW engine were actually 7.43kW and 7.85kW, respectively. When flywheel weight was reduced from $32.2kg_f$ to $24.2kg_f$, outputs were increased from 7.43kW to 7.70kW in 6.0kW engine and from 7.85kW to 8.25kW in 7.5kW engine. 3. When the flywheel weight was reduced from $32.2kg_f$ to $24.2kg_f$, fuel consumption ratio was decreased from 300.8 to 296.8g/kW-hr in 6.0kW engine and also from 313.6 to 312.8g/kW-hr in 7.5 kW engine, respectively. 4. When the flywheel weight was reduced from $32.2kg_f$ to $24.2kg_f$, mechanical efficiency of engine was increased from 76.1% to 76.8% in 6.0kW engine and also from 76.7% to 77.0% in 7.5kW engine, respectively. 5. When the flywheel weight was reduced from $32.2kg_f$ to $24.2kg_f$, vibration was decreased at X-axis and Z-axis in 6.0kW engine, however, slightly increased at Y-axis in 6.0kW engine and at all axes in 7.5kW engine. 6. When the flywheel weight was reduced from $32.2kg_f$ to $24.4kg_f$ motoring loss was decreased from 2.33kW to 1.75kW in 6.0kW engine and also from 2.46kW to 1.84kW in 7.5kW engine.

  • PDF

A study on Broad Quantification Calibration to various isotopes for Quantitative Analysis and its SUVs assessment in SPECT/CT (SPECT/CT 장비에서 정량분석을 위한 핵종 별 Broad Quantification Calibration 시행 및 SUV 평가를 위한 팬텀 실험에 관한 연구)

  • Hyun Soo, Ko;Jae Min, Choi;Soon Ki, Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.20-31
    • /
    • 2022
  • Purpose Broad Quantification Calibration(B.Q.C) is the procedure for Quantitative Analysis to measure Standard Uptake Value(SUV) in SPECT/CT scanner. B.Q.C was performed with Tc-99m, I-123, I-131, Lu-177 respectively and then we acquired the phantom images whether the SUVs were measured accurately. Because there is no standard for SUV test in SPECT, we used ACR Esser PET phantom alternatively. The purpose of this study was to lay the groundwork for Quantitative Analysis with various isotopes in SPECT/CT scanner. Materials and Methods Siemens SPECT/CT Symbia Intevo 16 and Intevo Bold were used for this study. The procedure of B.Q.C has two steps; first is point source Sensitivity Cal. and second is Volume Sensitivity Cal. to calculate Volume Sensitivity Factor(VSF) using cylinder phantom. To verify SUV, we acquired the images with ACR Esser PET phantom and then we measured SUVmean on background and SUVmax on hot vials(25, 16, 12, 8 mm). SPSS was used to analyze the difference in the SUV between Intevo 16 and Intevo Bold by Mann-Whitney test. Results The results of Sensitivity(CPS/MBq) and VSF were in Detector 1, 2 of four isotopes (Intevo 16 D1 sensitivity/D2 sensitivity/VSF and Intevo Bold) 87.7/88.6/1.08, 91.9/91.2/1.07 on Tc-99m, 79.9/81.9/0.98, 89.4/89.4/0.98 on I-123, 124.8/128.9/0.69, 130.9, 126.8/0.71, on I-131, 8.7/8.9/1.02, 9.1/8.9/1.00 on Lu-177 respectively. The results of SUV test with ACR Esser PET phantom were (Intevo 16 BKG SUVmean/25mm SUVmax/16mm/12mm/8mm and Intevo Bold) 1.03/2.95/2.41/1.96/1.84, 1.03/2.91/2.38/1.87/1.82 on Tc-99m, 0.97/2.91/2.33/1.68/1.45, 1.00/2.80/2.23/1.57/1.32 on I-123, 0.96/1.61/1.13/1.02/0.69, 0.94/1.54/1.08/0.98/ 0.66 on I-131, 1.00/6.34/4.67/2.96/2.28, 1.01/6.21/4.49/2.86/2.21 on Lu-177. And there was no statistically significant difference of SUV between Intevo 16 and Intevo Bold(p>0.05). Conclusion Only Qualitative Analysis was possible with gamma camera in the past. On the other hand, it's possible to acquire not only anatomic localization, 3D tomography but also Quantitative Analysis with SUV measurements in SPECT/CT scanner. We could lay the groundwork for Quantitative Analysis with various isotopes; Tc-99m, I-123, I-131, Lu-177 by carrying out B.Q.C and could verify the SUV measurement with ACR phantom. It needs periodic calibration to maintain for precision of Quantitative evaluation. As a result, we can provide Quantitative Analysis on follow up scan with the SPECT/CT exams and evaluate the therapeutic response in theranosis.