• Title/Summary/Keyword: $Vs^{30}$

Search Result 1,724, Processing Time 0.033 seconds

Boron Doping Method Using Fiber Laser Annealing of Uniformly Deposited Amorphous Silicon Layer for IBC Solar Cells (IBC형 태양전지를 위한 균일하게 증착된 비정질 실리콘 층의 광섬유 레이저를 이용한 붕소 도핑 방법)

  • Kim, Sung-Chul;Yoon, Ki-Chan;Kyung, Do-Hyun;Lee, Young-Seok;Kwon, Tae-Young;Jung, Woo-Won;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.456-456
    • /
    • 2009
  • Boron doping on an n-type Si wafer is requisite process for IBC (Interdigitated Back Contact) solar cells. Fiber laser annealing is one of boron doping methods. For the boron doping, uniformly coated or deposited film is highly required. Plasma enhanced chemical vapor deposition (PECVD) method provides a uniform dopant film or layer which can facilitate doping. Because amorphous silicon layer absorption range for the wavelength of fiber laser does not match well for the direct annealing. In this study, to enhance thermal affection on the existing p-a-Si:H layer, a ${\mu}c$-Si:H intrinsic layer was deposited on the p-a-Si:H layer additionally by PECVD. To improve heat transfer rate to the amorphous silicon layer, and as heating both sides and protecting boron eliminating from the amorphous silicon layer. For p-a-Si:H layer with the ratio of $SiH_4$ : $B_2H_6$ : $H_2$ = 30 : 30 : 120, at $200^{\circ}C$, 50 W, 0.2 Torr for 30 minutes, and for ${\mu}c$-Si:H intrinsic layer, $SiH_4$ : $H_2$ = 10 : 300, at $200^{\circ}C$, 30 W, 0.5 Torr for 60 minutes, 2 cm $\times$ 2 cm size wafers were used. In consequence of comparing the results of lifetime measurement and sheet resistance relation, the laser condition set of 20 ~ 27 % of power, 150 ~ 160 kHz, 20 ~ 50 mm/s of marking speed, and $10\;{\sim}\;50 {\mu}m$ spacing with continuous wave mode of scanner lens showed the correlation between lifetime and sheet resistance as $100\;{\Omega}/sq$ and $11.8\;{\mu}s$ vs. $17\;{\Omega}/sq$ and $8.2\;{\mu}s$. Comparing to the singly deposited p-a-Si:H layer case, the additional ${\mu}c$-Si:H layer for doping resulted in no trade-offs, but showed slight improvement of both lifetime and sheet resistance, however sheet resistance might be confined by the additional intrinsic layer. This might come from the ineffective crystallization of amorphous silicon layer. For the additional layer case, lifetime and sheet resistance were measured as $84.8\;{\Omega}/sq$ and $11.09\;{\mu}s$ vs. $79.8\;{\Omega}/sq$ and $11.93\;{\mu}s$. The co-existence of $n^+$layeronthesamesurfaceandeliminating the laser damage should be taken into account for an IBC solar cell structure. Heavily doped uniform boron layer by fiber laser brings not only basic and essential conditions for the beginning step of IBC solar cell fabrication processes, but also the controllable doping concentration and depth that can be established according to the deposition conditions of layers.

  • PDF

The Effects of Moxibustion at CV12 on Cerebral Blood Flow and Peripheral Blood Flow (중완(中脘)에 신기구 뜸시술이 뇌혈류 및 말초혈류 변화에 미치는 영향)

  • Kim, Do-Hyung;Park, Seung-Chan;Cho, Min-Kyoung;Kwon, Jung-Nam;Hong, Jin-Woo;Lee, In
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.1
    • /
    • pp.24-36
    • /
    • 2014
  • Objectives : This study was performed to evaluate the effects of moxibustion on cerebral blood flow, peripheral blood flow and blood pressure. Methods : We designed a randomized, cross-over study that included 20 healthy, male volunteers who were randomly assigned to one of two groups (the moxibustion group or the control group). The initial trial was followed by a washout period of one week before the groups were switched and the trial repeated. The cerebral blood flow and peripheral blood flow of the volunteers in both groups were measured by mean velocity (Vm), peak systolic velocity (Vs), pulsatility index (PI), perfusion units (PU) and mean blood pressure (BP) before the intervention (baseline), 30 minutes after the intervention, and again 60 minutes after the intervention. Results : 1. The Vm increased significantly in the moxibustion group. The Vs also constantly increased in moxibustion group, but there was no significant difference. 2. The PI decreased significantly in the control group at 0-30 minutes and in the moxibustion group at 30-60 minutes. 3. The PU constantly decreased in moxibustion group. In control group, the PU decreased at 30 minutes and increased slightly at 60 minutes. 4. The mean blood pressure did not show any significant difference between the two groups. Conclusions : This study shows that moxibustion at CV12 increased the cerebral blood flow. Based on this result, we can suggest that moxibustion at CV12 might be helpful in improving the functional recovery of stroke patients. However, further research needs to be conducted on a larger numbers of subjects in order to confirm these effects.

Biogas Production from Sewage Sludge in 30L Microbial Electrolysis Cell (30L 미생물전기분해전지의 하수슬러지로부터 바이오가스 생산 특성)

  • Lee, Myoung-Eun;Ahn, Yongtae;Shin, Seung Gu;Seo, Sun-Chul;Chung, Jae Woo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.4
    • /
    • pp.25-33
    • /
    • 2019
  • Operating characteristics of a 30 L microbial electrolysis cell (MEC) for producing biogas from sewage sludge was studied. During the 32-day inoculation period, carbon dioxide concentration decreased and methane concentration increased with operating time, and the overall methane content of biogas was 69.1% with a production rate of 171.6 mL CH4/L·d. In fed-batch experiments for 6 operating cycles, CH4 concentration of 66.5~77.2% was obtained at a production rate of 184.9~372.9 mL CH4/L·d, COD, TS and VS removal efficiency ranged from 28.2 to 42.1%, 20.7 to 37.5% and 18.5 to 36.9%, respectively. The MEC system was observed to be stabilized as operating cycles were repeated after inoculation. In the last operating cycle, 5221 mL/L of methane was produced with CH4 yield of 316.7 L CH4/kg CODrem, and the energy recovery was 73%.

Solubilization Characteristics of Piggery Slurry by Different Storage type and Temperature Conditions (돈분 슬러리의 저장형태 및 온도에 따른 가용화 특성)

  • Park, Woo-Kyun;Jun, Hang-Bae;Park, Noh-Back;Hong, Seung-Gil
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.4
    • /
    • pp.348-353
    • /
    • 2010
  • The current study investigated the fate of organic matter in piggery slurry under two different store systems(closed store system and open store system) in association with different temperature. Thirty days after storing in both systems at $20^{\circ}C$, it was observed that the content of organic matter remained in piggery slurry with closed store system was twice more than that with open store system implying more efficient degradation of organic matter with open store system. Temperature also influenced on the organic matter degradation in piggery slurry as shown decline in TS and VS contents as the temperature increased. With store at $35^{\circ}C$, 29% of initial organic matter was reduced while there was only 23% reduction of organic matter at $20^{\circ}C$. There was no difference in the type of organic fatty acids(VFAs) produced under the range of temperature(20, $35^{\circ}C$) simulating summer condition. Increases in organic fatty acids contents with hydrolysis and acid producing microbial was observed from 15 days after initiating store of the piggery slurry and the total organic acid amount produced 30 days after store was $2,829\;mg{\cdot}COD/L$ and $9,123\;mg{\cdot}COD/L$ at $20^{\circ}C$ and $35^{\circ}C$, respectively. These corresponded to 5.4% and 17.4% of the initial organic matter contents in piggery slurry, respectively.

Elliptical Centric Techniques and Tricks About the Usefulness of the Clinical Application (Elliptical Centric과 TRICKS 기법의 임상 적용에 관한 유용성 연구)

  • Kim, Sae-Ssak;Goo, Eun-Hoe;Dong, Kyung-Rae;Kweon, Dae-Chel;Lee, Jae-Seung;Cho, Jae-Hwan;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • To prospectively determine the diagnostic performance a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of the head and neck vascular diseases. Over a period of two months, A total of 100 patients(average ages : $50{\pm}8$, male : 60, female : 40) with head and neck vascular diseases were performed on the GE excite 3.0 T units with 8-channel head coil and 4-channel NV coil. Imaging parameters for a typical study were as follow: SBC(TR/ TE/ FA/ SliceThicken./ Slab/ Freq./ FOV/ BW/Scan Time) = 5.4/ min/ 30/ 2/ zip2/ 70/ $224{\times}448$/ 30/ 62.50/ 28, TRICKS(TR/ TE/ FA/ Slice Thicken/Slab/ Freq./ FOV/ BW/ Temp Res./ Scan Time = 3.6/ min/ 25/ 4/ 30/ $160{\pm}384$, zip512/ 30/ 100/ 1 to 1.5/ 23). The analysis of all MR images, which have respect-ively classified two techniques into some diseases. The results of the former were divided into two groups(SBC, TRICKS)with 4 grading of two reader, respectively. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed(p < 0.05). In 33 of 100 patients, arterio-venous malformation was 11% at TRICKS, subclavian vein stenosis : 8%, fistular sinus : 4%, jugular vein stenosis:6%, Middle Cerebral Artery bypass surgery : 4%, p < 0.05). The rest of 67 patients were considered as the results of SBC(14% in the basilar artery stenosis, carotid stenosis : 16%, vertebral stenosis : 17%, central neuro-cytoma : 5%, meningioma : 5%, Not appliable : 10%, p < 0.05). Sensitivity and specificity of TRICKS MR angiography in SVS, FS, JVS, MCABS were improved compared with those at standard MR angiography. In SBS MR angiography which were improved in BAS, CS, VS, CN, Meningioma. In conclusion, TRICKS MR angiography of the SVS, FS, JVS, MCABS is superior to standard MR angiography regarding the number of diagnostic grading. The SBS MR angiography were improved in BAS, CS, VS, CN, Meningioma. and assessment of the degree of luminal narrowing on both TRICKS and SBS.

  • PDF

Investigation of Spherical LiMn2O4 Cathode Materials by Spray-drying with Different Electrochemical Behaviors at High Rate (분무건조법으로 제조한 구형 스피넬계 LiMn2O4 양극소재의 합성 조건에 따른 고출력 거동에 대한 연구)

  • Song, Jun Ho;Cho, Woosuk;Kim, Young Jun
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.2
    • /
    • pp.50-56
    • /
    • 2016
  • Spherical lithium manganese oxide spinel, $Li_{1.10}Mn_{1.86}Al_{0.02}Mg_{0.02}O_4$ was prepared by wet-milling, spray-drying, and sintering process. In the spray-drying process, solid content in slurry was varied from 20 to 30 wt%. In the sintering process, the precursors have been sintered under air or $O_2$ atmosphere. While the as-prepared samples exhibit excellent electrochemical properties at room temperature, the discharge voltage profiles at 5.0C are very different one from another. The origin for the difference especially at initial state of discharge is oxygen defect. The sample prepared in air has larger capacity related to the plateau at 3.3 V (vs. $Li/Li^+$) which is caused by the oxygen defects than the one prepared in $O_2$. The difference of discharge voltage profiles especially at the final state of discharge comes from different diffusion rate of $Li^+$ ions. The sample prepared from 30 wt% solid content of slurry shows twice higher diffusion rate than the samples prepared from 20 wt% solid content, which is attributed to better compactness between primary particles for the sample prepared from 30wt % solid content than the one prepared by 20 wt%.

Optimization of In Vivo Embryo Production and Pregnancy following Embryo Transfer in Hanwoo Cattle

  • Jeon, Soon-Hong;Jung, Kyoung Sub;Choi, Jae-Won;Heo, Young-Tae;Xu, Yong-Nan;Kim, Nam-Hyung
    • Journal of Embryo Transfer
    • /
    • v.28 no.4
    • /
    • pp.307-314
    • /
    • 2013
  • Embryos formed in vivo were collected from 171 donors housed in Chung Cheong Buk-Do Institute of Livestock and Veterinary Research of the Chungbuk community during the years 2009~2012. We evaluated annual embryo collection, effect of follicle stimulating hormone (FSH), controlled internal drug release (CIDR) and prostaglandin (PG) administration to the donor for superovulation and controlling the estrus cycle, seasonal effects of embryo collection and compared the number of embryos recovered as per the collection days and pregnancy rate. In all, 1,243 embryos were collected from 118 donors with an average of $7.31{\pm}5.35$ embryos per donor, out of which 69.4% were transferable. Dosages of FSH required for inducing superovulation in various donors were compared. Average number of embryos collected from donors administered with 30 AU of FSH ($7.13{\pm}5.74$ per donor) was not significantly different from that of donors who were given an injection of 24 AU of FSH ($7.53{\pm}4.91$ per donor). However, the percentage of transferable embryos in the 30AU FSH-administered group (63.2 %, 449 of 711) was higher than that in the 24AU FSH-administered group (77.8%, 414 of 532). In the group of donors under a natural estrus cycle, the FSH dose administered did not influence the number of transferable embryos produced ($7.49{\pm}6.25$ per donor for 30 AU of FSH vs $7.49{\pm}4.92$ per donor for 24 AU of FSH). However, in donors administered with CIDR and PG for controlling the estrus cycle, the FSH dose affected the average number of transferable embryos collected ($4.25{\pm}2.87$ per donor for 30 AU of FSH vs $8.50{\pm}6.36$ per donor for 24 AU of FSH). We collected embryos from donors 6, 7 or 8 days after artificial insemination (AI). Results showed that the percentage of transferable embryos among those collected 8 days after AI was significantly higher than that among embryos collected 6 or 7 days after AI. Seasonal variations did not affect number of recovered embryos and pregnancy rates in natural estrus cycle and CIDR treatment groups (48.28% and 42.55%) but higher than pregnancy rate of frozen embryos (19.63%). These results indicated that administration of FSH beyond a threshold dose (at least 24 AU) has no beneficial effect on the production embryos and that collection of embryos 7~8 days after AI is optimal for embryo recovery. CIDR treatment induced superovulation in short term and had no influence on the natural estrus cycle. Finally, although good-quality embryos were transferred, freezing significantly reduced the pregnancy rates after transfer.

Measurement of Growth and Chlorophyl in Barley Exposed by X-ray (X선에 노출된 보리의 생장과 엽록소 측정)

  • Lee, Won-Jeong;Lee, Mo-Kwon;Lee, Jung Rok;Kim, Ha Neul;Yoo, Se-Jong;Lee, Bae-Won;Jeong, Sun-Cheol
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.253-260
    • /
    • 2021
  • The purpose of this study is to measure of growth and chlorophyl in barley exposed by X-ray. Barley seed was soaked 24h duration in water, then was classified into two group; pre-seed germination group (Pre-G) or post-seed germination group (Post-G). Also, divided as control subgroup and experimental subgroup(10Gy, 20Gy, 30Gy) in each group. Experimental subgroups were exposed by X-ray using linear accelerator (Clinac IS, VERIAN, USA). Expose condition was 6 MV X-ray, SSD 100 cm, 18×10 cm, 600 MU/min. Length was measured every day for 10 days and 10th day for weight. Chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) in l0th day. Data analysis was performed using SPSS ver 22.0(Chicago, IL, USA), ANOVA test (Dunnett_T3) between control subgroup and experimental subgroup in group and Independent T-test between Pre-G and Post-G in subgroup. In Pre-G, length of barley was significantly difference between control and 30Gy in 4th day (4.3 vs. 1.5, p= 0.011). Length of 30Gy was statistical difference with control(10th day; 14.4 vs. 6.3, p < 0.01), and was not in 10Gy or 20Gy in all day. In experimental subgroup, length was shorter as increasing radiation dose. In Post-G, length of barley was not difference statistically between control and experimental subgroup in first day, but more difference between two subgroup with increasing duration after exposing. Length of experimental subgroup was shorter significantly compared with control in 10th day, and no significant difference between experimental subgroup. Density of chlorophyl was increasing with increasing radiation dose in Pre-G and Post-G. Chlorophyl density of control was lower than 30Gy; 0.26ppm in Pre-G, 0.29ppm in Post-G). Growth and chlorophyl of barley was effected by X-ray. It is expected to be used as basic data for future radiobiological research.

Cryoanalgesia vs Bupivacain Intercostal Nerve Block for the Post -thoracotomy Pain (개흉술 후 흉부동통억제를 위한 늑간신경냉동 요법과 약물주입요법에 관한 비교연구)

  • 최영호
    • Journal of Chest Surgery
    • /
    • v.27 no.11
    • /
    • pp.942-947
    • /
    • 1994
  • Post-thoracotomy pain is so severe that lead to postoperative pulmonary complications due to the patient`s inability to cough, deep breathing and chest wall motion. Many authors have been trying to reduce the post-thoracotomy pain, but there is no method of complete satisfaction. In 1990, we reported the result that the cryoanalgesia reduce the immediate postoperative pain significantly. We try to compare the effect of cyroanalgesia with the effect of Bupivacain intercostal nerve block for the post-thoracotomy pain control. Ninety patients, who undergoing thoracotomy in Korea University Medical Center Guro Hospital between the January 1993 and September 1993, were evaluated. The patients were divided into three groups : Group A, control, the patients without pain control procedure [N=30], Group B, the patients with Bupivacain intercostal nerve block [N=30], Group C, the patients with cryoanalgesia [N=30]. Postoperative analgesic effects were evaluated by the scoring system which made arbiturary by author. The results were that the Bupivacain intercostal nerve block markedly reduced the immediate postoperative pain compare with two other groups, the cryoanalgesia reduced the immediate postoperative pain significantly compare with control group, the pain reduction effect of the two groups- cryoanalgesia and Bupivacain intercostal nerve block- were not different at postoperative seventh day, probably due to the action time of Bupivacain and the result that there were no significant complications of the procedures.

  • PDF

Effect of Sputtering Working Pressure on the Optical and Electrical Properties of InZnO Thin-Film Transistors (스퍼터링 공정 압력이 InZnO 박막트랜지스터의 광학 및 전기적 특성에 미치는 영향)

  • Park, Ji-Min;Kim, Hyoung-Do;Jang, Seong Cheol;Kim, Hyun-Suk
    • Korean Journal of Materials Research
    • /
    • v.30 no.4
    • /
    • pp.211-216
    • /
    • 2020
  • Amorphous In-Ga-Zn-O (a-IGZO) thin film transistors, because of their relatively low mobility, have limits in attempts to fulfill high-end specifications for display backplanes. In-Zn-O (IZO) is a promising semiconductor material for high mobility device applications with excellent transparency to visible light region and low temperature process capability. In this paper, the effects of working pressure on the physical and electrical properties of IZO films and thin film transistors are investigated. The working pressure is modulated from 2 mTorr to 5 mTorr, whereas the other process conditions are fixed. As the working pressure increases, the extracted optical band gap of IZO films gradually decreases. Absorption coefficient spectra indicate that subgap states increase at high working pressure. Furthermore, IZO film fabricated at low working pressure shows smoother surface morphology. As a result, IZO thin film transistors with optimum conditions exhibit excellent switching characteristics with high mobility (≥ 30㎠/Vs) and large on/off ratio.