• Title/Summary/Keyword: $Vs^{30}$

Search Result 1,724, Processing Time 0.029 seconds

Effect of the Artificial Shrinkage on the Development of the Vitrified Bovine Embryos

  • Ha, A-Na;Cho, Su-Jin;Deb, Gautam-Kumar;Bang, Jae-Il;Kwon, Tae-Hyeon;Choi, Byeong-Hyun;Kong, Il-Keun
    • Journal of Embryo Transfer
    • /
    • v.25 no.1
    • /
    • pp.9-14
    • /
    • 2010
  • This study was conducted to find out the effects of artificial shrinkage (AS) on post-thaw development of bovine embryos. The blastocoelic cavity of blastocyst was punctured to remove its fluid contents and then incubated in the holding medium (HM) for 10 min. The punctured and non-punctured (control) blastocysts were equilibrated in vitrification solution 1 (VS1; TCM-199+20% FBS+10% EG) for 5 min and vitrification solution 2 (VS2; TCM199+20% FBS+35% EG+5% PVP+0.5 M Sucrose) for 1 min and vitrified by direct dropping into the liquid nitrogen. Vitrified blastocysts (punctured and control) were thawed and cultured in vitro (12 hr) for studying survival and hatching rates. The levels of shrinkage were measured by the volume of the blastocyst during equilibration in VS1 (at 1, 3 and 5 min of equilibration) and VS2 (at 30 and 60 sec of equilibration) that was considering the volume of non-punctured blastocyst in HM as 100%. The levels of shrinkage were higher in punctured group (62.4, 64.6, 64.3% at 1, 3 and 5 min in VS1; 50.6 and 52.7% at 30 and 60 sec in VS2) than control group (84.8, 86.6, 86.4% at 1, 3 and 5 min in VS1; 72.1 and 68.8% at 30 and 60 sec in VS2), but within each group the levels of shrinkage were similar. The survival (90.9%) and hatching (50.0%) rates of vitrified blastocysts at 12 hr post-thaw were higher in punctured group than that in control group (76.9% and 0.0% respectively). We confirmed that vitrification solutions (VS1 and VS2) have no toxic effect on the survival of blastocysts because the survival rates of blastocysts exposed to VS1 and VS2 for 24 hr were similar between punctured and control groups (94.3 vs. 96.0%; p>0.05). In conclusion, the preliminary data show that AS of blastocyst may improve survival and hatching rate after thawing.

Preliminary Study of Semi-continuous Liquid Recirculating Anaerobic Digestion for Source Separated Food Waste (음식물류 폐기물 처리를 위한 준 회분식 액순환 건식 혐기성 소화법에 대한 기초연구)

  • Cho, Chan-Hui;Lee, Byong-Hi
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.2
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, the experiment was carried out to produce methane by applying Semi-Continuous Leachate Recirculation Anaerobic Digestion System fed with source separated food waste from school cafeteria. There were two systems and each system consisted of a bioreactor and a liquid tank. Each bioreactor had a screen near the bottom of the reactor. 2.5L of separated liquid was transferred to the liquid tank for 30min each day by using a tubing pump and the liquid from the liquid tank was pumped to the bioreactor at the upper of the bioreactor as soon as the transfer was ended. Through this circulation, the liquid having high concentration of VFAs was supplied to the top of bioreactor. At the beginning of the experiment, food waste/inoculum anaerobic sludge volume ratio was 2:8 that is 9g VS/L of OLR(Organic Loading Rate). Feeding was conducted every two weeks. Experimental results showed that the contents of moisture, combustible matter, ash were 65.91%, 32.73%, and 1.36%, respectively. Two different food waste loading were studied. The average organic loading rates were 3.51g VS/d for System A and 3.86g VS/d for System B, respectively. The average produced methane based on food waste fed to bioreactor were observed as $6.30m^3CH_4/kgVS{\cdot}d$ for system A and $4.94m^3CH_4/kgVS{\cdot}d$ for System B, respectively.

Quality of Life Findings of Adjuvant FOLFOX4 vs. XELOX in Stage III Colon Cancer Patients

  • Youn Jung Choi;Seun Ja Park;Moo In Park;Won Moon;Sung Eun Kim;Jae Hyun Kim;Byung Kwon Ahn;Sung Uhn Baek;Seung Hyun Lee;Seung Hun Lee
    • Journal of Digestive Cancer Research
    • /
    • v.5 no.2
    • /
    • pp.73-85
    • /
    • 2017
  • Background: To compare the quality of life (QoL), the convenience of chemotherapy and satisfaction between colon cancer patients treated with FOLFOX4 and XELOX. Methods: The study was conducted in 26 patients with stage III colon cancer. Patients were received FOLFOX4 (n=17) or XELOX (n=9). QoL, convenience, and satisfaction were assessed using the Quality of Life Questionnaire-C30 (QLQ-C30), Quality of Life Questionnaire-Chemotherapy Induced Peripheral neuropathy (QLQ-CIPN) and Functional Assessment of Chronic Illness Therapy Chemotherapy Convenience and Satisfaction Questionnaire (FACIT-CCSQ), respectively. Patients completed questionnaires at baseline, at cycle 4 (C4) and cycle 8 (C8) (FOLFOX4) or at cycle 3 (C3) and cycle 6 (C6) visits (XELOX) and at their final visit. Results: In the QLQ-C30, at the final visit, XELOX patients had better functional scores than FOLFOX4 patients (physical: 85.7 vs.60.4, p=0.03; role: 83.3 vs. 57.5, p=0.04) as well as better symptom scores (constipation: 9.5 vs. 40.4, p=0.01). In CIPN, at the C6/C8 visit, XELOX patients had lower motor scale scores than FOLFOX4 patients (3.8 vs. 21.6, p=0.02). Moreover, at the C6/C8 visit, XELOX was more convenient than FOLFOX4 in FACIT-CCSQ (79.7 vs. 55.5, p=0.04). Male patients were especially likely to consider XELOX to be more convenient (90.0 vs. 55.0, p=0.01) and satisfactory (55.4 vs. 26.2, p=0.03) and fewer concern (91.0 vs. 65.0, p=0.03) than FOLFOX4. XELOX patients spent fewer days on hospital visits at C3/C4, C6/C8 and final visit (2.8 vs. 4.2, p=0.01; 2.7 vs. 4.1, p=0.01; 3.0 vs. 4.5, p=0.01). Conclusion: XELOX may be a better adjuvant chemotherapy choice for patients with colon cancer than FOLFOX4 in terms of QoL, convenience, and satisfaction.

  • PDF

The Simplest Flowchart Stating the Mechanisms for Organic Xenobiotics-induced Toxicity: Can it Possibly be Accepted as a "Central Dogma" for Toxic Mechanisms?

  • Park, Yeong-Chul;Lee, Sundong;Cho, Myung-Haing
    • Toxicological Research
    • /
    • v.30 no.3
    • /
    • pp.179-184
    • /
    • 2014
  • Xenobiotics causing a variety of toxicity in biological systems could be classified as two types, inorganic and organic chemicals. It is estimated that the organic xenobiotics are responsible for approximately 80~90% of chemical-induced toxicity in human population. In the class for toxicology, we have encountered some difficulties in explaining the mechanisms of toxicity caused especially by organic chemicals. Here, a simple flowchart was introduced for explaining the mechanism of toxicity caused by organic xenobiotics, as the central dogma of molecular biology. This flowchart, referred to as a central dogma, was described based on a view of various aspects as follows: direct-acting chemicals vs. indirect-acting chemicals, cytochrome P450-dependent vs. cytochrome P450-independent biotransformation, reactive intermediates, reactivation, toxicokinetics vs. toxicodynamics, and reversibility vs. irreversibility. Thus, the primary objective of this flowchart is to help better understanding of the organic xenobiotics-induced toxic mechanisms, providing a major pathway for toxicity occurring in biological systems.

Electrical Properties of semiconducting $VO_2$-based Critical Temperature Sensors (반도성 $VO_2$계 급변온도센서의 전기적 특성)

  • 유광수;김종만;정형진
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.10
    • /
    • pp.866-870
    • /
    • 1993
  • For VO2-based sensors applicable to temperature measurements and optical disk materials by the nature of semiconductor to metal transition, the crystallinity and temperature vs. resistance characteristics were investigated as a function of the heat treatment temperature. The bead-type sensors were prepared through typical sensor fabrication processing and heat-treated at 40$0^{\circ}C$, 50$0^{\circ}C$, and $600^{\circ}C$, respectively, for 30 minutes in H2 gas atmosphere. As results of the temperature vs. resistance measurements, the electrical resistance in the phase transition range was decreased by 102 order for the VO2 sensor and by 103 order for the V71P11Sra18 system. It was estimated that the hysteresis, temperature vs. resistance, and current vs. voltage characteristics of the V71P11Sr18 system could be utilized for commericialization as a temperature sensor.

  • PDF

Diagnostic Ability of High-definition Imaging Using Ultraslim Endoscopes in Early Gastric Cancer

  • Sugita, Tomomi;Suzuki, Sho;Ichijima, Ryoji;Ogura, Kanako;Kusano, Chika;Ikehara, Hisatomo;Gotoda, Takuji;Moriyama, Mitsuhiko
    • Journal of Gastric Cancer
    • /
    • v.21 no.3
    • /
    • pp.246-257
    • /
    • 2021
  • Purpose: It is unclear whether high-definition (HD) imaging improves visibility and diagnostic ability in early gastric cancer (EGC) compared with standard-definition (SD) imaging. We aimed to compare the diagnostic performance and visibility scores of HD and SD ultraslim endoscopes in EGC. Materials and Methods: We used HD and SD ultraslim endoscopes to obtain 60 images with similar compositions of gastric environments. Of the 60 images, 30 showed EGC (15 images for each modality) and 30 showed no EGC (15 images for each modality). Seventeen endoscopists evaluated the presence and location of the lesions in each image. Diagnostic ability was compared between modalities. The color difference between a lesion and the surrounding mucosa (ΔE) was measured and compared between the modalities. Results: The ability of HD to detect EGC was significantly higher than that of SD (accuracy: 80.8% vs. 71.6%, P=0.017; sensitivity: 94.9% vs. 76.5%, P<0.001; positive predictive value, 76.2% vs. 55.3%, P<0.001; and negative predictive value (NPV), 94.1% vs. 73.5%, P<0.001). The ability of HD to determine the horizontal extent of EGC was significantly higher than that of SD (accuracy: 71.0% vs. 57.8%, P=0.004; sensitivity: 75.3% vs. 49.0%, P<0.001; NPV, 72.9% vs. 55.9%, P<0.001; and area under the curve: 0.891 vs. 0.631, P=0.038). The mean ΔE was significantly higher for HD than for SD (10.3 vs. 5.9, P=0.011). Conclusions: The HD ultraslim endoscope showed a higher diagnostic performance in EGC than the SD endoscope because it provided good color contrast.

Effect of Flocculant Injection Ratio in NIR (Near-Infrared Ray) Drying for BIO-SRF (Solid Recovered Fuel) of Swage Sludge (하수슬러지 BIO-SRF (Solid Recovered Fuel) 생산을 위한 NIR (Near Infrared Ray) 건조시 응집제 주입비율이 미치는 영향)

  • Lee, Kang-min;Lee, Seung-Won
    • Journal of Environmental Science International
    • /
    • v.30 no.2
    • /
    • pp.135-143
    • /
    • 2021
  • This study executed evaluation of drying characteristics based on the polymer injection rate (8%, 10% and 12%) and the drying method[NIF(near-infrared ray). According to this study analyzed VS, VS/TS, and calorific value compared with 'the auxiliary fuel standard of the thermoelectric power plant and the combined heat & power plant'. The results are as follows. In the case of NIR, the VS was slightly changed at the early stage of the material preheating period and the constant drying rate period with low moisture evaporation. But VS reduction was shown higher as moisture was dried. In the case of non-digested sludge with high VS content, the VS reduction rate by drying was shown lower than that of digested sludge. As the flocculant injection rate increased, the VS loss due th drying was found to be small. Also, the higher the flocculant injection rate was the longer the drying time. Especially, in the case of the NIR drying equipment, as the moisture content of sewage sludge decreased(moisture content 20~40%), the loss of net VS also showed a tendency to increase sharply. It is shown that the high calorific value according to the drying time of the non-digested sludge was changed from 590 kcaℓ/kg to 3,005 kcaℓ/kg and from 539 kcaℓ/kg to 2,796 kcaℓ/kg.

Comparison of short-term outcomes of open and laparoscopic assisted pancreaticoduodenectomy for periampullary carcinoma: A propensity score-matched analysis

  • Utpal Anand;Rohith Kodali;Kunal Parasar;Basant Narayan Singh;Kislay Kant;Sitaram Yadav;Saad Anwar;Abhishek Arora
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.28 no.2
    • /
    • pp.220-228
    • /
    • 2024
  • Backgrounds/Aims: Postoperative pancreatic fistula is the key worry in the ongoing debate about the safety and effectiveness of total laparoscopic pancreaticoduodenectomy (TLPD). Laparoscopic-assisted pancreaticoduodenectomy (LAPD), a hybrid approach combining laparoscopic resection and anastomosis with a small incision, is an alternative to TLPD. This study compares the short-term outcomes and oncological efficacy of LAPD vs. open pancreaticoduodenectomy (OPD). Methods: A retrospective analysis of data of all patients who underwent LAPD or OPD for periampullary carcinoma at a tertiary care center in Northeast India from July 2019 to August 2023 was done. A total of 30 LAPDs and 30 OPDs were compared after 1:1 propensity score matching. Demographic data, intraoperative and postoperative data (30 days), and pathological data were compared. Results: The study included a total of 93 patients, 30 underwent LAPD and 62 underwent OPD. After propensity score matching, the matched cohort included 30 patients in both groups. The LAPD presented several advantages over the OPD group, including a shorter incision length, reduced postoperative pain, earlier initiation of oral feeding, and shorter hospital stays. LAPD was not found to be inferior to OPD in terms of pancreatic fistula incidence (Grade B, 30.0% vs. 33.3%), achieving R0 resection (100% vs. 93.3%), and the number of lymph nodes harvested (12 vs. 14, p = 0.620). No significant differences in blood loss, short-term complications, pathological outcomes, readmissions, and early (30-day) mortality were observed between the two groups. Conclusions: LAPD has comparable safety, technical feasibility, and short-term oncological efficacy.

Growth Performance of Nursery Pigs Fed 30% Distillers Dried Grain with Solubles (DDGS) and the Effects of Pelleting on Performance and Nutrient Digestibility

  • Zhu, Zhengpeng;Hinson, Rodney B.;Ma, Li;Li, Defa;Allee, Gary L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.6
    • /
    • pp.792-798
    • /
    • 2010
  • Four experiments with 2,020 nursery pigs (Triumph-4${\times}$PIC Camborough 22) were conducted at a commercial research site to evaluate the effects of including 30% distillers dried grain with solubles (DDGS) in late nursery diets on pig growth performance and to compare the effects of pelleted and meal diets containing 30% DDGS on growth performance and nutrient digestibility. In Exp. 1, 312 pigs (10.54${\pm}$0.16 kg) were allotted to two diets: corn-soybean meal based control diet and a corn-soybean meal diet containing 30% DDGS. In Exp. 2, 337 pigs (16.70${\pm}$0.14 kg) were used to validate Exp. 1 with similar diets. In Exp. 3, 665 pigs (11.77${\pm}$0.12 kg) were allotted to diets containing 30% DDGS, but in different forms: meal or pellet. Fecal samples were collected during the final day of the trials to measure nutrient and energy apparent total tract digestibility (ATTD). In Exp. 4, 706 pigs (18.40${\pm}$0.18 kg) were allotted to the same diets as Exp. 3. In Exp. 1 and 2, there was no (p>0.05) effect of DDGS on ADG, ADFI or G:F. In Exp. 3, pelleting improved (p<0.01) ADG (578 vs. 541 g/d) and G:F (714 vs. 674 g/kg), with no difference (p>0.05) in ADFI. The ATTD of most nutrients and energy were improved by pelleting (p<0.05). In Exp. 4, ADG (717 vs. 675 g/d) and G:F (680 vs. 648 g/kg) were improved by pelleting (p<0.01), with no difference (p>0.05) in ADFI. In conclusion, 10-23 kg pigs in late nursery phase can be fed up to 30% DDGS without having a detrimental effect on pig performance, and pelleting the diet will increase nutrient and energy availability.