• Title/Summary/Keyword: $UV-TiO_2$

Search Result 760, Processing Time 0.027 seconds

Pore Size Control of a Highly Transparent Interfacial Layer via a Polymer-assisted Approach for Dye-sensitized Solar Cells

  • Lee, Chang Soo;Lee, Jae Hun;Park, Min Su;Kim, Jong Hak
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.392-399
    • /
    • 2019
  • A highly transparent interfacial layer (HTIL) to enhance the performance of dye-sensitized solar cells (DSSCs) was prepared via a polymer-assisted (PA) approach. Poly(vinyl chloride)-graft-poly(oxyethylene methacrylate) (PVC-g-POEM) was synthesized via atom-transfer radical polymerization (ATRP) and was used as a sacrificial template. The PVC-g-POEM graft copolymer induced partial coordination of a hydrophilic titanium isopropoxide (TTIP) sol-gel solution with the POEM domain, resulting in microphase separation, and in turn, the generation of mesopores upon calcination. These phenomena were confirmed using Fourier-transform infrared (FT-IR) spectroscopy, UV-visible light transmittance spectroscopy, scanning electron microscopy (SEM), and X-ray diffraction (XRD) analysis. The DSSCs incorporating HTIL60/20 (consisting of a top layer with a pore size of 60 nm and a bottom layer with a pore size of 20 nm) exhibited the best overall conversion efficiency (6.36%) among the tested samples, which was 25.9% higher than that of a conventional blocking layer (BL). DSSC was further characterized using the Nyquist plot and incident-photon to electron conversion efficiency (IPCE) spectra.

Thickness Determination of Ultrathin Gate Oxide Grown by Wet Oxidation

  • 장효식;황현상;이확주;조현모;김현경;문대원
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.107-107
    • /
    • 2000
  • 최근 반도체 소자의 고집적화 및 대용량화의 경향에 다라 MOSFET 소자 제작에 이동되는 게이트 산화막의 두께가 수 nm 정도까지 점점 얇아지는 추세이고 Giga-DRAM급 차세대 UNSI소자를 제작하기 위해 5nm이하의 게이트 절연막이 요구된다. 이런 절연막의 두께감소는 게이트 정전용량을 증가시켜 트랜지스터의 속도를 빠르게 하며, 동시에 저전압동작을 가능하게 하기 때문에 게이트 산화막의 두께는 MOS공정세대가 진행되어감에 따라 계속 감소할 것이다. 따라서 절연막 두께는 소자의 동작 특성을 결정하는 중요한 요소이므로 이에 대한 정확한 평가 방법의 확보는 공정 control 측면에서 필수적이다. 그러나, 절연막의 두께가 작아지면서 게이트 산화막과 crystalline siliconrksm이 계면효과가 박막의 두께에 심각한 영향을 주기 때문에 정확한 두께 계측이 어렵고 계측방법에 따라서 두께 계측의 차이가 난다. 따라서 차세대 반도체 소자의 개발 및 양산 체계를 확립하기 위해서는 산화막의 두께가 10nm보다 작은 1nm-5nm 수준의 박막 시료에 대한 두께 계측 방법이 확립이 되어야 한다. 따라서, 본 연구에서는 습식 산화 공정으로 제작된 3nm-7nm 의 게이트 절연막을 현재까지 알려진 다양한 두께 평가방법을 비교 연구하였다. 절연막을 MEIS (Medim Energy Ion Scattering), 0.015nm의 고감도를 가지는 SE (Spectroscopic Ellipsometry), XPS, 고분해능 전자현미경 (TEM)을 이용하여 측정 비교하였다. 또한 polysilicon gate를 가지는 MOS capacitor를 제작하여 소자의 Capacitance-Voltage 및 Current-Voltage를 측정하여 절연막 두께를 계산하여 가장 좋은 두께 계측 방법을 찾고자 한다.다. 마이크로스트립 링 공진기는 링의 원주길이가 전자기파 파장길이의 정수배가 되면 공진이 일어나는 구조이다. Fused quartz를 기판으로 하여 증착압력을 변수로 하여 TiO2 박막을 증착하였다. 그리고 그 위에 은 (silver)을 사용하여 링 패턴을 형성하였다. 이와 같이 공진기를 제작하여 network analyzer (HP 8510C)로 마이크로파 대역에서의 공진특서을 측정하였다. 공진특성으로부터 전체 품질계수와 유효유전율, 그리고 TiO2 박막의 품질계수를 얻어내었다. 측정결과 rutile에서 anatase로 박막의 상이 변할수록 유전율은 감소하고 유전손실은 증가하는 결과를 나타내었다.의 성장률이 둔화됨을 볼 수 있다. 또한 Silane 가스량이 적어지는 영역에서는 가스량의 감소에 의해 성장속도가 둔화됨을 볼 수 있다. 또한 Silane 가스량이 적어지는 영역에서는 가스량의 감소에 의해 성장속도가 줄어들어 성장률이 Silane가스량에 의해 지배됨을 볼 수 있다. UV-VIS spectrophotometer에 의한 비정질 SiC 박막의 투과도와 파장과의 관계에 있어 유리를 기판으로 사용했으므로 유리의투과도를 감안했으며, 유리에 대한 상대적인 비율 관계로 투과도를 나타냈었다. 또한 비저질 SiC 박막의 흡수계수는 Ellipsometry에 의해 측정된 Δ과 Ψ값을 이용하여 시뮬레이션한 결과로 비정질 SiC 박막의 두께를 이용하여 구하였다. 또한 Tauc Plot을 통해 박막의 optical band gap을 2.6~3.7eV로 조절할 수 있었다. 20$0^{\circ}C$이상으로 증가시켜도 광투과율은 큰 변화를 나타내지 않았다.부터 전분-지질복합제의 형성 촉진이 시사되었다.이것으로 인하여 호화억제에 의한 노화 방지효과가 기대되었지만 실제로 빵의 노화는 현저히 진행되었다

  • PDF

A Study of Electro-Optical Properties of Polyester Acrylate-Based Polymer-Dispersed Liquid Crystals Using TIZO/Ag/TIZO Multilayer Transparent Electrodes (TIZO/Ag/TIZO 다층막 투명전극을 이용한 폴리에스터 아크릴레이트 기반 고분자분산액정의 전기광학적 특성 연구)

  • Cho, Jung-Dae;Heo, Gi-Seok;Hong, Jin-Who
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.50-57
    • /
    • 2022
  • Ti-In-Zn-O (TIZO)/Ag/TIZO multilayer transparent electrodes were prepared on glass substrates at room temperature using RF/DC magnetron sputtering. Obtained multilayer structure comprising TIZO/Ag/TIZO (10 nm/10 nm/40 nm) with the total thickness of 60 nm showed a transmittance of 86.5% at 650 nm and a sheet resistance of 8.1 Ω/□. The multilayer films were expected to be applicable for use in energy-saving smart window based on polymer-dispersed liquid crystal (PDLC) because of their transmittance properties to effectively block infrared rays (heat rays). We investigated the effects of the content ratio of prepolymer, the thickness of the PDLC coating layer, and the ultraviolet (UV) light intensity on electro-optical properties, and the surface morphology of polyester acrylate-based PDLC systems using new TIZO/Ag/TIZO transparent conducting electrodes. A PDLC cell with a thickness of 15 ㎛ PDLC layer photocured at an UV intensity of 1.5 mW/cm2 exhibited good driving voltage, favorable on-state transmittance, and excellent off-haze. The LC droplets formed on the surface of the polymer matrix of the PDLC composite had a size range of 1 to 3 ㎛ capable of efficiently scattering incident light. Also, the PDLC-based smart window manufactured using TIZO/Ag/TIZO multi-layered transparent electrodes in this study exhibited a light brown, which will have an advantage in terms of aesthetics.

Effects of Operating Parameters on Electrochemical Degradation of Rhodamine B and Formation of OH Radical Using BDD Electrode (BDD 전극을 이용한 OH 라디칼 생성과 염료 분해에 미치는 운전인자의 영향)

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.19 no.9
    • /
    • pp.1143-1152
    • /
    • 2010
  • The purpose of this study is to degradation of Rhodamine B (RhB, dye) and N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the electro-generation of OH radical) in solution using boron doped diamond (BDD) electrode. The effects of applied current (0.2~1.0 A), electrolyte type (NaCl, KCl, and $Na_2SO_4$) and electrolyte concentration (0.5~3.0 g/L), solution pH (3~11) and air flow rate (0~4 L/min) were evaluated. Experimental results showed that RhB and RNO removal tendencies appeared with the almost similar thing, except of current. Optimum current for RhB degradation was 0.6 A, however, RNO degradations was increased with increase of applied current. The RhB and RNO degradation of Cl type electrolyte were higher than that of the sulfate type. The RhB and RNO degradation were increased with increase of NaCl concentration and optimum NaCl dosage was 2.5 g/L. The RhB and RNO concentrations were not influenced by pH under pH 7. Optimum air flow rate for the oxidants generation and RhB and RNO degradation were 2 L/min. Initial removal rate of electrolysis process was expressed Langmuir - Hinshelwood equation, which is used to express the initial removal rate of UV/$TiO_$2 process.

Study of Degradation of Bisphenol A with $TiO_2$ Powder in CPC System (CPC (Compound Parabolic Collector) 내 이산화티탄을 이용한 비스페놀 A (Bisphenol A)의 분해에 관한 연구)

  • Hwang, An-Na;Park, Myung-Hee;Lim, Beom-Guk;Khim, Jee-Hyeong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.107-112
    • /
    • 2011
  • In this study, photocatalytic degradation and mineralization of bisphenol A (BPA), which has been listed as one of endocrine disruptors, were carried out in the CPC system using $Tio_2$ slurry and UVA irradiation. The degradation efficiency has been investigated under the controlled parameters including initial concentration (5, 10, 20 mg/L), dosage of $Tio_2$ (0.1, 0.5, 1.0 g/L), UVA power (0, 80, 120 W) and temperature (0, 20, 30). At 10mg/L of initial concentration, BPA was degraded above 80% after 10min, BPA were degraded 97% and 49% at 20 mg/L and 30 mg/L, respectively. At $Tio_2$ dosage was 0.1 and 0.5 g/L, the degradations of BPA showed similar trend and were about 70% after 1 hr, and the degradation of BPA was above 80% after 30 min at 1 g/L of $Tio_2$ dosage. The increase of degradation seem to be due to the increase in the total surface area, namely number of active sites, available for the photocatalytic reaction as the dosage of photocatalyst increased. When the UVA power was 120 W, BPA was degraded rapidly above 60% after 10min of reaction time. To investigate the effect of temperature, carried out experiment controlled temperature, there were no significant differences depending on the temperature. After 1hr, the degradation of BPA were 46%, 67%, and 69% at 10, 20 and $30^{\circ}C$.

Optimization and Characteristics of Removal Condition of Livestock Wastewater Using a Photocatalytic Process (광촉매공정 적용시 축산폐수의 처리특성 및 최적화)

  • Park, Jae-Hong
    • Clean Technology
    • /
    • v.13 no.3
    • /
    • pp.222-227
    • /
    • 2007
  • The photocatalytic degradation of livestock wastewater has been investigated over $TiO_2$ photocatalysts irradiated with a ultraviolet (UV) light. The effect of operational parameters, i.e., distance, reaction area, concentration of suspended solids(SS), and column diameter on the degradation of livestock wastewater has been performed in lab-scale. The optimal conditions for livestock wastewater were determined: distance was 3 cm (less than 7 cm), reaction area was $3.6\;m^2$, SS concentration was 40 mg/L (less than 300 mg/L) and column diameter was 5 mm (less than 10 mm). Under the optimal conditions, COD, color and coliform removal efficiencies were approximately 49%, 53% and 100%, respectively. Non-biodegradable COD removal efficiency increased with 57% using by photocatalysis process. Therefore, it is shown that photocatalysis has an effect on degradation of non-biodegradable organic matter.

  • PDF

Experiment on Reduction of Pollutants in Titanium Dioxide Photocatalytic Ventilation System (이산화티탄 광촉매 환기장치의 오염물질 저감 실험)

  • Song, Yong Woo
    • Land and Housing Review
    • /
    • v.13 no.2
    • /
    • pp.117-123
    • /
    • 2022
  • In this study, titanium dioxide photocatalyst was applied to the ventilation system to reduce particulate matter and nitrogen oxides (NOx), which are representative indoor harmful substances. A reaction device capable of installing an ultraviolet lamp was designed and manufactured so that the pollutant decomposition effect of the titanium dioxide photocatalyst identified through previous studies could be applied indoors. The reaction device was used on the indoor ventilation system and applied to the Mock-Up test. As a result of the Mock-up test, the NOx reduction performance according to the change in air volume once per hour and five times per hour was confirmed. As a result, it was confirmed that as the number of ventilation increases, the NOx reduction time decreases proportionally, and the reduction performance increases.

The Mineralogical and Geochemical Study on Korean Scheelites and its Application to the Ore Prospecting (한국산 灰重石鑛의 광물학적, 지화학적 연구 및 그의 探査에의 이용)

  • So, Chil-Sup;Park, Maeng-Eon
    • Economic and Environmental Geology
    • /
    • v.12 no.2
    • /
    • pp.79-93
    • /
    • 1979
  • Twenty five samples of the scheelite-powellite series from twelve Korean tungsten deposits of various geologic settings were studied mineralogically and geochemically. Variations in the trace-element contents of the scheelite minerals are considered in relation to geologic settings and mineralogic properties. Scheelites from ore deposits developed in similar geologic settings and under similar physicochemical conditions are characterized by specific combinations of trace elements.

  • PDF

Numerical Analysis on Thermal-Induced Degradation of n-i-p Structure Perovskite Solar Cells Using SCAPS-1D (SCAPS-1D 시뮬레이션을 이용한 n-i-p 구조 페로브스카이트 태양전지의 열적 열화 원인 분석)

  • Kim, Seongtak;Bae, Soohyun;Jeong, Younghun;Han, Dong-Woon;Kim, Donghwan;Mo, Chan Bin
    • Current Photovoltaic Research
    • /
    • v.10 no.1
    • /
    • pp.16-22
    • /
    • 2022
  • The long-term stability of PSCs against visual and UV light, moisture, electrical bias and high temperature is an important issue for commercialization. In particular, since the operation temperature of solar cell can rise above 85℃, a study on thermal stability is required. In this study, the cause of thermal-induced degradation of PSCs was investigated using the SCAPS-1D simulation tool. First, PSCs of TiO2/CH3NH3PbI3/Spiro-OMeTAD/Au structure were exposed to a constant temperature of 85℃ to observe changes in conversion efficiency and quantum efficiency. Because the EQE reduction above 500 nm was remarkable, we simulated PSCs performance as a function of lifetime, doping density of perovskite and spiro-OMeTAD. Consequently, the main cause of thermal-induced degradation is considered to be the change in the perovskite doping concentration and lifetime due to ion migration of perovskite.

Determination of Optimized Operational Parameters for Photocatalytic Oxidation Reactors Using Factorial Design (요인분석법을 이용한 광촉매 산화반응조의 최적 운영인자 도출)

  • Hur, Joon-Moo;Cheon, Seung-Yul;Rhee, In-Hyoung;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.2
    • /
    • pp.85-91
    • /
    • 2004
  • The objective of this study is to determine the optimum conditions of operational parameters using factorial design for phenol degradation in photocatalytic oxidation reactors. Factorial design is widely used to select the dominant factors and their ranges in experiments involving several factors where it is necessary to study the effect of factors on a response. The effects of initial concentration of phenol, intensity of UV light and surface area of catalyst on phenol degradation were investigated. Two levels were considered in this study so that the experiment was a $2^3$ factorial design with three replicates. The experimental results show that an increase in initial concentration of phenol from 5 to 50 mg/L intensity of UV light from 5,000 to $20,000\;{\mu}W/cm^2$, and surface area of catalyst from 740 to $2,105\;cm^2$ enhanced the phenol degradation rate by an average of 1.86, 1.79, and 2.10 mg/L hr, respectively. Interaction effects do not appear to be as large on the phenol degradation rate as the main effects of single factors. The optimum working condition for photocatalytic oxidation reactors, despite the higher three factors the better removal rate, is the highest surface area or catalyst.