• Title/Summary/Keyword: $Tm_2O_3$

Search Result 142, Processing Time 0.03 seconds

VLSI Design of Reed-Solomon Decoder over GF($2^8$) with Extreme Use of Resource Sharing (하드웨어 공유 극대화에 의한 GF($2^8$) Reed-Solomon Decoder의 VLSI설계)

  • 이주태;이승우;조중휘
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.3
    • /
    • pp.8-16
    • /
    • 1999
  • This paper describes a VLSI design of Reed-Solomon(RS) decoder using the modified Euclid algorithm, with the main theme focused on the $\textit{GF}(2^8)$. To get area-efficient design, a number of new architectures have been devised with maximal register and Euclidean ALU unit sharing. One ALU is shared to replace 18 ALUs which computes an error locator polynomial and an error evaluation polynomial. Also, 18 registers are shared to replace 24 registers which stores coefficients of those polynomials. The validity and efficiency of the proposed architecture have been verified by simulation and by FLEX$^TM$ FPGA implementation in hardware description language VHDL. The proposed Reed-Solomon decoder, which has the capability of decoding RS(208,192,17) and RS(182,172,11) for Digital Versatile Disc(DVD), has been designed by using O.6$\mu\textrm{m}$ CMOS TLM Compass$^TM$ technology library, which contains totally 17k gates with a core area of 2.299$\times$2.284 (5.25$\textrm{mm}^2$). The chip can run at 20MHz while the DVD requirement is 3.74MHz.

  • PDF

A study of $Smartpeg^{TM}'s$ lifetime according to sterilization for implant stability (임플랜트 안정성을 위한 자기공명막대의 소독방법에 따른 수명에 관한 연구)

  • Won, Ho-Yeon;Cho, In-Ho;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.42-52
    • /
    • 2008
  • Purpose: Resonance Frequency Analysis(RFA) technique can be used as an effective method in measuring the implant stability and documenting the clinical results. This technique also determines how stable the implant is before performing a prosthetic practice. Having become one the guidelines of the implant therapy whose final objective is the immediate loading, the $Osstell^{TM}$ mentor is giving a lot of information to the clinicians recently. In this communication, experiments were performed to investigate how reliable the measured ISQ values by $Osstell^{TM}$ mentor are, and to see if those are also stable even after sterilization. As five objectives: 1) How stable measured ISQ values after fixation $Smartpeg^{TM}s$ for 400 times. 2) How stable measured ISQ values after 'attach-detach'$Smartpeg^{TM}'s$ for 400 times. 3) How stable measured ISQ values after clinical sterilization methods. 4) How stable measured ISQ values after repeatedly sterilization in autoclave for 10 times. 5) What is the critical temperature which is lost the magnetism of $Smartpeg^{TM}$. Materials and Methods: Clinical sterilization methods(Autoclave sterilization, Dentistar sterilization, Ultra violet sterilization, Vacuum dry unit sterilization, Boiling water sterilization, combined $H_{2}O_{2}$ and Alcohol sterilization).$Smartpeg^{TM}s$. D3 Block bone($3{\times}9{\times}2cm$). Osstem implant(${\emptyset}4.1$-10mm).$Osstell^{TM}$ mentor. Individual experiment was used 8 number of $Smartpeg^{TM}s$ and they had measured to ISQ values of before experiment and after experiment. Results: 1. The measured ISQ values did not change after fixation $Smartpeg^{TM}s$ for 400 times. 2. There was no significant changes in the measured ISQ values of 'attach-detach $Smartpeg^{TM}s'$ for 400 times. 3. The measured ISQ values did not change after the usual clinical sterilization methods. 4. The measured ISQ values did not change after sterilization in autoclave for 10 times. 5. It was impossible to exactly measure the critical temperature which is lost the magnetism of $Smartpeg^{TM}s$. But, the results was resulted to lost its magnetism in higher temperature than $150^{\circ}C$/10 minute. Conclusion: The measured ISQ values showed insignificant differences in case of no changes in the magnetism of the $Smartpeg^{TM}s$. It seems that the $Smartpeg^{TM}s$ can be used repeatedly in every measurement if the original magnetisms of the $Smartpeg^{TM}s$ can be recognized. There seems to be no significant changes in the measured ISQ values of 'attach-detach $Smartpeg^{TM}s'$ only if the screw pitches were unimpaired. The clinical sterilization methods seems acceptable because the result was resulted to lost its magnetism in higher temperature than $150^{\circ}C$/10minute.

Fabrication and Current Transport Properties of TmBCO Coated Conductors (TmBCO Coated Conductors 제조 및 전류 전송 특성 평가)

  • Kwon, O-Jong;Ko, Rock-Kil;Bae, Sung-Hwan;Koo, Hyun;Jung, Myung-Jin;Oh, Sang-Soo;Park, Chan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1307_1308
    • /
    • 2009
  • 고온초전도체 REBCO(RE=rare earth) 선재는 높은 전류전송밀도를 가지고 있기 때문에 고용량의 전류가 요구되는 응용분야에 사용되어 전력기기 등의 성능을 높일 수 있을 것으로 기대되고 있다. 이전까지 대부분의 REBCO 선재 연구들은 GdBCO, NdBCO, YBCO 등 비교적 Tc값이 높은 고온초전도체에 집중되어 왔다. 반면에 TmBCO는 대부분의 REBCO 보다 Tc값이 낮기 때문에 선재 연구 분야에서 거의 주목받지 않았다. 하지만 본 연구 결과에 따르면 TmBCO 선재는 비교적 낮은 Tc(88K) 값에도 불구하고 우수한 전류전송밀도(Jc=2.3MA/$cm^2$) 특성을 나타내기 때문에 고온초전도 선재로서 활용이 가능하다. 또한 NdBCO 선재에 비해 낮은 기판온도에서 제조가 가능함으로써 공정상의 이점을 가질 수 있음을 확인하였다.

  • PDF

Parameter Estimation of VfloTM Distributed Rainfall-Runoff Model by Areal Rainfall Calculation Methods - For Dongchon Watershed of Geumho River - (유역 공간 강우 산정방법에 따른 VfloTM 분포형 강우-유출 모형의 매개변수 평가 - 금호강 동촌 유역을 대상으로 -)

  • Kim, Si Soo;Jung, Chung Gil;Park, Jong Yoon;Jung, Sung Won;Kim, Seong Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.1
    • /
    • pp.9-15
    • /
    • 2013
  • This study is to evaluate the parameter behavior of VfloTM distributed rainfall-runoff model by applying 3 kinds of rainfall interpolation methods viz. Inverse Distance Weighting (IDW), Kriging (KRI), and Thiessen network (THI). For the 1,544 $km^2$ Dongcheon watershed of Nakdong river, the model was calibrated using 4 storm events in 2007 and 2009, and validated using 2 storm events in 2010. The model was calibrated with Nash-Sutcliffe model efficiency of 0.97 for IDW, 0.94 for KRI, and 0.95 for THI respectively. For the sensitive parameters, the saturated hydraulic conductivity ($K_{sat}$) for IDW, KRI, and THI were 0.33, 0.31, and 0.43 cm/hr, and the soil suction head at the wetting front (${\Psi}_f$) were 4.10, 3.96, and 5.19 cm $H_2O$ respectively. These parameters affected the infiltration process by the spatial distribution of antecedent moisture condition before a storm.

Solvent Extraction of Heavy Rare Earth Elements Using PC88A from Synthesis Solution of Low Concentration Rare Earth Solution (저농도 희토류 용액으로부터 PC88A를 이용한 중희토류의 용매추출 연구)

  • Ahn, Nak-Kyoon;Im, Byoungyong;Lee, Jieun;Park, Jae Ryang;Lee, Chan-Gi;Park, Kyung-Soo
    • Resources Recycling
    • /
    • v.26 no.4
    • /
    • pp.26-33
    • /
    • 2017
  • The behavior on the solvent extraction of heavy rare earths (HRE) by using PC88A was confirmed to demonstrate the possibility of recovery on the HRE from industrial wastewater, which consist of low concentration rare earth. We verified the extraction behavior of the HRE through a change of equilibrium pH, extractant concentration and A/O ratio, and also confirmed the stripping behavior depending on the type of mineral acids. At equilibrium pH 1.0, extraction of rare earth (RE) was completed from 95% to 100%. In all extraction conditions, it tend to be extracted in order of high atomic number. When A/O ratio was 10/1, Yb and Tm were concentrated at the maximum and increased 6-fold and 3-fold compared to initial concentration, respectively. To confirm the stripping behavior of the RE, three mineral acids were applied to the organic phase and consequently rate of stripping was increased in order of $HNO_3$, $H_2SO_4$ and HCl.

Fabrication and Characteristics Analysis of Ti:LiNbO$_{3}$ Optical Waveguide (Ti:LiNbO$_{3}$ 광도파로 제작 및 특성분석)

  • 윤형도;김성구;이한영;윤대원
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.7
    • /
    • pp.109-116
    • /
    • 1998
  • In this work was produced and analyzed a z-cut Ti:LiNbO$_{3}$ optical waveguide which applies for various optical devices.A waveguide channel with a thickness 8 .mu.m and a length 66,000.mu.m and a mach-zehnder interferometer type waveguide were fabricated at a diffusion temperature 1050.deg. C for 6-8hours in a wet $O_{2}$ environment. The resulting Ti:LiNbO$_{3}$ optical waveguide was measured to have a Ti-strip thickness of 950.angs. and low loss. Surfaces and cross-sections of a fabricated waveguide were analysed. The mode pattern anaysis revealed that the waveguide showed a single mode at a 1550nm wavelength. The effective dimension of the waveguide was calculated by measuring a gaussian profile; Wx=10.95.mu. and Wy=9.14.mu.m. a propagation loss, of 0.50dB/cm for a TM mode and 0.45dB/cm for a TE mode, was low enough to be accepatable for optical devices.

  • PDF

Evaluation of Dynamic X-ray Imaging Sensor and Detector Composing of Multiple In-Ga-Zn-O Thin Film Transistors in a Pixel (픽셀내 다수의 산화물 박막트랜지스터로 구성된 동영상 엑스레이 영상센서와 디텍터에 대한 평가)

  • Seung Ik Jun;Bong Goo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.359-365
    • /
    • 2023
  • In order to satisfy the requirements of dynamic X-ray imaging with high frame rate and low image lag, minimizing parasitic capacitance in photodiode and overlapped electrodes in pixels is critically required. This study presents duoPIXTM dynamic X-ray imaging sensor composing of readout thin film transistor, reset thin film transistor and photodiode in a pixel. Furthermore, dynamic X-ray detector using duoPIXTM imaging sensor was manufactured and evaluated its X-ray imaging performances such as frame rate, sensitivity, noise, MTF and image lag. duoPIXTM dynamic X-ray detector has 150 × 150 mm2 imaging area, 73 um pixel pitch, 2048 × 2048 matrix resolution(4.2M pixels) and maximum 50 frames per second. By means of comparison with conventional dynamic X-ray detector, duoPIXTM dynamic X-ray detector showed overall better performances than conventional dynamic X-ray detector as shown in the previous study.

Effects of Al2O3-RE2O3 Additive for the Sintering of SiC and the Fabrication of SiCf/SiC Composites (SiC 소결에 미치는 Al2O3-RE2O3 첨가제의 영향과 SiCf/SiC 복합체의 제조)

  • Yu, Hyun-Woo;Raju, Kati;Park, Ji Yeon;Yoon, Dang-Hyok
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.6
    • /
    • pp.364-371
    • /
    • 2013
  • The sintering behavior of monolithic SiC is examined using the binary sintering additive of $Al_2O_3$-rare earth oxide ($RE_2O_3$, where RE = Sc, Nd, Dy, Ho, or Yb). Through hot pressing at 20 MPa and $1750^{\circ}C$ for 1 h in an Ar atmosphere for 52 nm fine ${\beta}$-SiC powder added with 5 wt% sintering additive, a SiC density of > 97% is achieved, which indicates the effectiveness of $Al_2O_3-RE_2O_3$ system as a sintering of additive for SiC. Based on this result, 7 wt% of $Al_2O_3-Sc_2O_3$ is tested as an additive system for the fabrication of a continuous SiC fiber-reinforced SiC-matrix composite ($SiC_f$/SiC). Electrophoretic deposition combined with the application of ultrasonic pulses is used to efficiently infiltrate the matrix phase into the voids of $Tyranno^{TM}$-SA3 fabric. After hot pressing, a composite density of > 97% is obtained, along with a maximum flexural strength of 443 MPa.

A Study on the Acousto-Optical Wavelength Tunable Filters Utilizing Tapered Directional Coupler SAW Guides (Tapered 방향성 가중 결합 음향파 도파로 구조를 이용한 음향광학형 파장가변 광 필터에 관한 연구)

  • Jeong, Gi-Jo;Kim, Jeong-Hui;Jeong, Hong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.1
    • /
    • pp.58-66
    • /
    • 2002
  • Acousto-optical wavelength tunable optical filters in LiNbO$_3$ have been demonstrated using taperd directional weighted coupling acoustic waveguides and Ti double diffusion technique. Conversion efficiency in excess of 61%, 86% and sidelobe intensity of -14.29㏈, -14.99㏈ were measured at a wavelength of 1551.1nm RF frequency of 173.58MHz and RF power of 35㎽ for both TE and TM input polarizations, respectivelv. A spectral width of ~l.8nm and linear tuning late of 8.6nm/MHz were demonstrated. A 2.82$mutextrm{s}$ switching time has been measured. With two channels with 2.5nmseparation, channel cross-talk was lower than -l4㏈ for single wavelength filtering due to sidelobe.

Effects of Al2O3 addition on nanocrystal formation and crystallization kinetics in (1-x)Li2B4O7-xAl2O3 glasses

  • Choi, Hyun Woo;Kim, Su Jae;Yang, Hang;Yang, Yong Suk;Rim, Young Hoon;Cho, Chae Ryong
    • Journal of Ceramic Processing Research
    • /
    • v.20 no.1
    • /
    • pp.63-68
    • /
    • 2019
  • We investigated the effects of Al2O3 addition on (1-x)Li2B4O7-xAl2O3 (LBAO; x = 0, 0.005, 0.01, 0.05, 0.07, and 0.1) glasses. The glasses were synthesized by a conventional melt-quench method. Structural transformations of the LBAO glasses were assessed via X-ray diffraction analysis. Estimations of ΔT, KGS = (Tc-Tg)/(Tm-Tc), activation energy, and the Avrami parameter were performed using differential thermal analysis and differential scanning calorimetry. An interpretation of non-isothermal kinetics of the crystallization process is presented using the modified Ozawa equation. The activation energy E increased from 3.3 to 3.5 eV for the LBAO (x < 0.01) glasses whereas those of the LBAO (x > 0.05) glasses slightly increased from 3.75 to 4.05 eV. The exponent n was estimated to be 3.9 ± 0.1 for the LBAO (x < 0.01) glasses and 3.2 ± 0.02 for the LBAO (x > 0.05) glasses. Microstructural characterization of the glassy and crystalline phases using atomic force microscopy was investigated. The effects of Al2O3 on the LBAO glasses include a decreased nucleation rate in the crystallization process and a significantly reduced crystal size.