• Title/Summary/Keyword: $Tm_2O_3$

Search Result 142, Processing Time 0.03 seconds

Analysis on correlation between bone strength by FEA, micro-CT parameters and bone mineral density (유한요소법에 의한 골강도와 micro-CT 지표 및 골밀도간의 상관관계)

  • Yoon, Young-Nam;Lee, Wan;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • Purpose : Bone mineral density (BMD) and bone microarchitecture are important determinants for bone strength. Recently micro-CT have provided possibilities for measuring a variety of structural indices to characterize bone microarchitecture. The objective of this study was to compare the BMD and micro-CT parameters with Young's modulus calculated by finite element analysis (FEA) for the evaluation of bone strength. Materials and Methods Bone specimens were obtained from the 18 female rabbits aged 16 weeks. Of those, 36 samples (right and left femur) were selected for 3D micro-CT analysis $(ANT^{TM},\;SKYSCAN,\;Belgium)$ and BMD by PIXlmus 2 (GE Lunar Co. USA). Five microstructural parameters of micro-CT, such as trabecular thickness (Tb.Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI) and degree of anisotropy (DOA) were studied. Young's modulus was obtained by software program (ANSYS 9.0, ANSYS Inc, Canonsburg, PA) based on micro-CT three dimensional images. Results : Young's modulus assessed by FEA correlated significantly with Tb.Th, BV/TV, BS/BV and SMI respectively. Young's modulus showed higher correlation with these rnicrostructural parameters of micro-CT than BMD. Microstructural parameters except DOA showed significant correlations within the examined group. Conclusion The microarchitectural parameters o( micro-CT and BMD represented some informations in the evaluation of bone strength assessed by FEA.

  • PDF

Chemical Changes of Kanjang Made with Barley Bran (보리등겨로 제조한 간장의 각종 성분 변화)

  • Lee, Eun-Jeong;Kwon, O-Jun;Im, Moo-Hyeog;Choi, Ung-Kyu;Son, Dong-Hwa;Lee, Suk-Il;Kim, Dae-Gon;Cho, Young-Je;Kim, Woo-Seong;Kim, Sung-Hong;Chung, Yung-Gun
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.751-756
    • /
    • 2002
  • For the development of functional jang-products, kanjang was prepared using barley bran. Optical density of barley bran kanjang was significantly high at 15 days after fermentation, and the amount of extract was $2{\sim}3$ fold higher than that of soybean kanjang. Among the flavor components identified in barley bran kanjang, the content of 2-furancarboxaldehyde was the highest, followed by 4-vinyl-2-methoxy-phenol, benzene-acetaldehyde, palmitic acid, and methyl-9,12-octadecadienoate. In barley bran and soybean mixtare (1 : 1) kanjang, the content of 2-furancarboxaldehyde was the highest, followed by benzeneacetaldehyde, diethyl phtalate, palmitic acid, and 2-chloroethyl linoleate. Flavor components detected in both barley bran kanjang and barey bran and soybean mixture kanjang were 2-furancarboxaldehyde, benzaldehyde, benzeneacetaldthyde, 4-vinyl-2-mehtoxy-phenol, 1-furfuryl-2-formy pyrrole, dimethyl-1,2-benzenedicarboxylate, diethyl phtalate, palmiticacid, dibutyl-1,2-benzenedicarboxylate, and di-(2-ethylhexyl)phthalate.

THE EFFECT OF LIGHT CURING METHODS AND RESIN ADHESIVES ON THE MICROLEAKAGE OF RESTORATIONS IN PRIMARY TEETH (광중합 방법 및 레진 접착제의 종류에 따른 유치 수복물의 미세누출)

  • Jeong, Young-Nam;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.592-599
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the effects of several light curing methods and several adhesives on the microleakage of composite resin restorations in primary teeth. Materials and methods : In 150 extracted human primary anterior teeth, O-shaped cavities were prepared in the labial surface ; the cavity diameter and depth were 1.6mm. The cavities were filled with light-activated composite resin, Compoglass. Four kinds of adhesives were used. Each filling materials were polymerized with three light cure methods. The restorations were polished using Sof-Lex discs(3M Co., USA). The samples were thermocycled 1,000 times between $5^{\circ}C$ and $55^{\circ}C$ with a 1-minute dwell time. Then, they were immersed in a 2% methylene blue solution(pH 7) for 12hours. Subsequently they were sectioned labio-lingually through the center of the restoration with a diamond saw at low speed with a water coolant, and evaluated by stereomicroscopy. Microleakage analyses were done, using scores from 0 to 4. Results : Results showed the least microleakage in Compoglass group(P<0.05). There were less microleakage in SBMP group among the adhesive groups, but no significant difference was observed(P>0.05). And there were no significant differences among the groups depending on curing methods(P>0.05).

  • PDF

Corrections on CH4 Fluxes Measured in a Rice Paddy by Eddy Covariance Method with an Open-path Wavelength Modulation Spectroscopy (개회로 파장 변조 분광법과 에디 공분산 방법으로 논에서 관측된 CH4 플럭스 자료의 보정)

  • Kang, Namgoo;Yun, Juyeol;Talucder, M.S.A.;Moon, Minkyu;Kang, Minseok;Shim, Kyo-Moon;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.1
    • /
    • pp.15-24
    • /
    • 2015
  • $CH_4$ is a trace gas and one of the key greenhouse gases, which requires continuous and systematic monitoring. The application of eddy covariance technique for $CH_4$ flux measurement requires a fast-response, laser-based spectroscopy. The eddy covariance measurements have been used to monitor $CO_2$ fluxes and their data processing procedures have been standardized and well documented. However, such processes for $CH_4$ fluxes are still lacking. In this note, we report the first measurement of $CH_4$ flux in a rice paddy by employing the eddy covariance technique with a recently commercialized wavelength modulation spectroscopy. $CH_4$ fluxes were measured for five consecutive days before and after the rice transplanting at the Gimje flux monitoring site in 2012. The commercially available $EddyPro^{TM}$ program was used to process these data, following the KoFlux protocol for data-processing. In this process, we quantified and documented the effects of three key corrections: (1) frequency response correction, (2) air density correction, and (3) spectroscopic correction. The effects of these corrections were different between daytime and nighttime, and their magnitudes were greater with larger $CH_4$ fluxes. Overall, the magnitude of $CH_4$ flux increased on average by 20-25% after the corrections. The National Center for AgroMeteorology (www.ncam.kr) will soon release an updated KoFlux program to public users, which includes the spectroscopic correction and the gap-filling of $CH_4$ flux.

Effects of Dissolved Oxygen and Depth on the Survival and Filtering Rate and Pseudofeces Production of a Filter-feeding Bivalve (Unio douglasiae) in the Cyanobacterial Bloom (남조류 대발생 환경에서 수심과 용존산소 변화에 따른 담수산 이매패(말조개)의 생존율, 여과율 및 배설물 생산)

  • Park, Ku-Sung;Kim, Baik-Ho;Um, Han-Yong;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.spc
    • /
    • pp.50-60
    • /
    • 2008
  • We performed the experiment to evaluate the effect of different DO concentrations (0.5, 4.5 and 9.0 $mgO_2L^{-1}$) and water depths (20, 50 and 80 cm) on the filtering rate, mortality, and pseudifeces production of Unio douglasiae against the cyanobacterial bloom (mainly Microcystis aeruginosa). A solitary-living bivalve U. douglasiae was collected in the upstream region of the North Han River (Korea). The harvested mussels were carefully transferred to the laboratory artificial management system, which was controlled temperature $(18{\pm}2^{\circ}C)$, flow rate (10L $h^{-1}$), food $(Chlorella^{TM})$, sediment (pebble and clay), light intensity (ca. $20{\mu}mol$ photons), and photocycle (12 L : 12 D). In the field observation, the mussel mortality was significantly correlated with water temperature, pH and DO concentration (P<0.05). The mortality was decreased with water depth; 65, 90, 80% of mortality at 20, 50, 80 cm water-depth, respectively. Filtering rate (FR) showed the highest value at 50 cm water depth, and thereby the concentration of chlorophyll-${\alpha}$ decreased continuously by 94% of the control at the end of the experiment. In contrast, FR decreased by 34% of the initial concentration at 20 cm water depth. Over the given water-depth range, the mussel FR ranged from $0.15{\sim}0.20L\;gAFDW^{-1}hr^{-1}$ during the 18hrs of experiment, and thereafter, they appeared to be approximately 0.11, 0.26 and 0.30 L $gAFDW^{-1}hr^{-1}$ at 20, 50 and 80cm water depth, respectively. FR was highest with the value of 0.46L $gAFDW^{-1}hr^{-1}\;at\;0.5mgO_2 L^{-1}$ at the early stage of the experiment, while it increased with DO concentration. Maximum pseudofaeces production was 11.2 mg $gAFDW^{-1}hr^{-1}\;at\;9.0mgO_2L^{-1}$. Our results conclude that U. douglasiae has a potential to enhance water quality in eutrophic lake by removing dominant cyanobacteria, but their effects vary with environmental parameters and the water depth at which they are located.

Three-dimensional finite element analysis on stress distribution of the mandibular implant-supported cantilever prostheses depending on the designs (임플란트 지지 하악 캔틸레버 보철물의 디자인에 따른 저작압 분산에 관한 삼차원 유한요소 분석)

  • Ban, Jae-Hyurk;Shin, Sang-Wan;Kim, Sun-Jong;Lee, Jeong-Yeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.70-81
    • /
    • 2009
  • Statement of problem: The position and length of cantilever influence on the stress distribution of implants, superstructure and bone. In edentulous mandible, implant-supported cantilever prostheses that based 4 or 6 implants between mental foramens has been attempted. Excessive bite force loaded at cantilever prosthesis causes bone resorption and breakage of superstructure prosthesis around posterior implants. To complement the cantilever length of conventional prosthesis, In 1992, (McCartney) introduced "cantilever-rest-implant" and Malo reported "All-on-Four" in 2003. Purpose: Analyze and compare the stress distribution of conventional cantilever prostheses with rest implant and All-on-$Four^{TM}$ implant prostheses. Material and method: The external loads(300 N vertically, 75 N horizontally) are applied to first molar area. The stress value, stress distribution and aspect of stress dispersion are analyzed by three-dimensional finite element analysis program, ANSYS ver. 10.0. Results: 1. The rest implant and "All-on-Four" implant system are superior to conventional cantilever prostheses to reduce stress on the bone and the superstructure around implants. 2. The rest implant was of the greatest advantage to stress distribution on bone, implant and superstructure. 3. With same number of implants, distally tilted implants are preferred to conventional cantilever prostheses for reducing the length of cantilever.

[ $^1H$ ] MR Spectroscopy of the Normal Human Brains: Comparison between Signa and Echospeed 1.5 T System (정상 뇌의 수소 자기공명분광 소견: 1.5 T Signa와 Echospeed 자기공명영상기기에서의 비교)

  • Kang Young Hye;Lee Yoon Mi;Park Sun Won;Suh Chang Hae;Lim Myung Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2004
  • Purpose : To evaluate the usefulness and reproducibility of $^1H$ MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. Materials and Methods : Localized $^1H$ MR spectroscopy ($^1H$ MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS $H_2O$ suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG : 64/128, and NEX=2/8 (Signa/Echospeed). Results : The SNR was about over $30\%$ higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). Conclusion : Both conventional and new MRI systems are highly reliable and reproducible for $^1H$ MR spectroscopic examinations in human brains and there are no significant differences in applications for $^1H$ MRS between two different MRI systems.

  • PDF

Bit-Rate Control Using Histogram Based Rate-Distortion Characteristics (히스토그램 기반의 비트율-왜곡 특성을 이용한 비트율 제어)

  • 홍성훈;유상조;박수열;김성대
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.9B
    • /
    • pp.1742-1754
    • /
    • 1999
  • In this paper, we propose a rate control scheme, using histogram based rate-distortion (R-D) estimation, which produces a consistent picture quality between consecutive frames. The histogram based R-D estimation used in our rate control scheme offers a closed-form mathematical model that enable us to predict the bits and the distortion generated from an encoded frame at a given quantization parameter (QP) and vice versa. The most attractive feature of the R-D estimation is low complexity of computing the R-D data because its major operation is just to obtain a histogram or weighted histogram of DCT coefficients from an input picture. Furthermore, it is accurate enough to be applied to the practical video coding. Therefore, the proposed rate control scheme using this R-D estimation model is appropriate for the applications requiring low delay and low complexity, and controls the output bit-rate ad quality accurately. Our rate control scheme ensures that the video buffer do not underflow and overflow by satisfying the buffer constraint and, additionally, prevents quality difference between consecutive frames from exceeding certain level by adopting the distortion constraint. In addition, a consistent considering the maximum tolerance BER of the voice service. Also in Rician fading channel of K=6 and K=10, considering CLP=$10^{-3}$ as a criterion, it is observed that the performance improment of about 3.5 dB and 1.5 dB is obtained, respectively, in terms of $E_b$/$N_o$ by employing the concatenated FEC code with pilot symbols.

  • PDF

An Improvement Plan of the Interactive ROK Army Interactive Electronic Technical Manuals (육군 전자식 기술교범 개선방안 연구)

  • Lee, Pan-Ju;Shim, Sang-Ryul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.399-406
    • /
    • 2020
  • The R.O.K Army has developed and operated TM to maintain the operation of weapons systems since its establishment. As more modern weapons systems were developed, the more efficient operation was limited by a large quantity. As a countermeasure, the DAPA has operated the IETM using the KAIS TOOL since 2003. However, 16 years later, they were shunned by operators for software instability and other reasons. Based on the results of an operational test and evaluation team of the Army headquarters, the analysis results of software instability, limited compatibility and integration, limited real-time updates, etc. were analyzed. It was confirmed that KAIS development tools were urgently needed. Therefore, in order to solve this current problem for the Army IETM, the first phase of this paper focused on improving the IETM by maintaining the application present, the second of the Army Electronic Technology manual, phase going to propose improvement plans for operational test and evaluation by lining 11 elements of comprehensive logistics support with an electronic technology code.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.