• Title/Summary/Keyword: $Theta^*$

Search Result 2,013, Processing Time 0.036 seconds

Optimization of Optics Design for 3D Laser Scanner (3차원 부품 레이저 용접용 스캐너 광학 최적설계)

  • Choi, Hae Woon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.6
    • /
    • pp.96-101
    • /
    • 2020
  • In this paper, we present the results of our research to perform 3D laser scanning functions by adding a focusing lens to a conventional 2D laser scanner. For the optical design, the ray-tracing technique was used along with a total of four lenses as the variable incident focusing lens, the collimating lens, and the F-Theta lens. As design variables, the curvature of the incident focusing lens (Lens #1) was assumed to be us, l mm and sumed mm, and the incident angles were set at 0cidenus, l. In addition, the distance between the focusing lens and the collimating lens was set to vary from 5 mm to 15 mm. When the incident focal length was varied from 5 mm to 15 mm, the exit focal length was calculated to vary from 67.5 mm to 56.8 mm for the lens with R = 100 mm and from 108.5 mm to 99.0 mm for the lens with R = 150 mm. When the incident angle was 0°, the focal aberration was only slightly observable at 10㎛ in both the x- and y-direction. At 7.5° was the focal aberration of approximately 20~50㎛ was measured at 20㎛. To investigate the chromatic aberration of the designed optical device, the distortion of the focus was observed when the 550 nm beam was simulated on lens designed for a 980 nm wavelength.

RF magnetron sputtering법으로 제작된 IGZO 박막의 Annealing 변화에 따른 특성 연구

  • Jin, Chang-Hyeon;Kim, Hong-Bae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.184.1-184.1
    • /
    • 2015
  • RF magnetron sputtering법을 이용하여 IGZO박막을 RF power 100W로 일정하게 유지시켜, 열처리 변화에 따른 구조적, 전기적, 광학적 특성 분석을 연구하였다. IGZO 타겟은 $In_2$ $O_3$, $Ga_2$ $O_3$, ZnO 분말을 각각 1:1:2 mol% 조성비로 혼합하여 소결한 타겟을 사용하였고, $20mm{\times}20mm$ XG glass 기판위에 IGZO박막을 증착하였다. sputtering의 조건은 base pressure $2.0{\times}$10^-6Torr, working pressure $2.0{\times}$10^-2Torr, RF power 100 W, 증착온도는 실온으로 고정, 증착된 박막은 Annealing장비로 $500^{\circ}C$, $700^{\circ}C$, $800^{\circ}C$로 열처리를 하였다. XRD 분석 결과 열처리 $700^{\circ}C$부터 2theta=31.4도에서 peak intensity가 증가하며 결정화가 진행되는 것을 확인하였다. AFM분석 결과 열처리 $700^{\circ}C$에서 최소 0.31 Roughness를 갖는 것을 확인하였고, Hall 측정 결과 열처리 $700^{\circ}C$에서 carrier concentration $4.91{\times}$10^19cm^-3, Mobility 14.4cm^2/V-s, Resistivity $8.7{\times}$10^-5${\Omega}-cm$로 확인하였으며, UV-Visible-NIR을 이용하여 열처리 한 모든 IGZO박막은 가시광선 영역에서 평균 85%이상의 광 투과성을 확인하였다.

  • PDF

Wetting Behavior of Dolomite Substrate by Liquid Fe-19%Cr-10%Ni Alloy at 1753K

  • Shin, Min-Soo;Lee, Joon-Ho;Park, Joo-Hyun
    • Korean Journal of Materials Research
    • /
    • v.19 no.2
    • /
    • pp.115-118
    • /
    • 2009
  • The use of dolomite refractories has increased during the past several years in the manufacturing of clean steel during the stainless steelmaking process. However, at the same time, the use of dolomite refractories has led to what is known as the skull formation. In the present work, to understand the skull formation, the wetting characteristics of dolomite substrates by liquid Fe-19wt%Cr-10wt%Ni alloys in various oxygen partial pressures were initially investigated at 1753K using the sessile drop technique. For comparison, the wetting characteristics of alumina substrates were investigated with the same technique. It was found that the wetting index, (1+$cos{\theta}$), of dolomite is approximately 40% higher compared to those of alumina. In addition, the oxygen partial pressure to generate the surface oxide, which may capture the liquid metal on the refractory surface, for dolomite is much lower than that for alumina. From this study, it was concluded that the use of dolomite is much more closely associated with the skull formation compared to the use of alumina due to the stronger wettability and the surface oxide formation at a lower oxygen partial pressure of dolomite.

Mixed Convection between Inclined Parallel Plates with different Temperatures (온도차를 갖는 경사진 평행평판 내의 혼합대류 열전달)

  • Piao, R.L.;Kwon, O.B.;Bae, D.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.33-39
    • /
    • 2005
  • Experiments are performed to study the mixed convection flow and heat transfer in an inclined parallel plates with the upper part cooled and the lower part heated uniformly. The Reynolds number ranges from $4.0{\times}10^{-3}\;to\;6.2{\times}10^{-2}$, the angle of inclination, ${\theta}$, from 0 to 45 degree from the horizontal line, and Pr of the high viscosity fluid is 909. In this paper, the PIV(Particle image velocimetry) with TLC(Thermo-sensitive liquid crystal) tracers is used for visualizing and analysis. This method allows simultaneous measurement of velocity and temperature field at a given instant of time. Quantitative data of the temperature and velocity are obtained by applying the color-image processing to a visualized image, and neural network is applied to the color-to-temperature calibration. This paper describes the methods, and presents the quantitative visualization of mixed convection. From this study, it is found that the flow pattern can be classified into three patterns which are affected by Reynolds number and the angle of inclination.

  • PDF

The Durability and Exhaust Emission Characteristics of an IDI Diesel Engine Using Biodiesel Fuel (바이오디젤유를 사용하는 간접분사식 디젤기관의 내구 및 배기 특성)

  • Ryu, Kyung-Hyun;Oh, Young-Taig
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.115-122
    • /
    • 2006
  • To evaluate the durability characteristics of in-direct injection diesel engine using BDF 20(a blend of 20% biodiesel fuel and 80% diesel fuel in volume), an IDI diesel engine used to commercial vehicle was operated on BDF 20 for 300 hours. Engine dynamometer testing was completed at regularly scheduled intervals to investigate the combustion characteristics, engine performance and exhaust emissions. The engine performance and exhaust emissions were sampled at 1 hour interval for analysis. From the results, the combustion variations such as the combustion maximum pressure($P_{max}$) and the crank angle at which this maximum pressure occurs(${\Theta}_{Pmax}$) were not appeared during long-time dynamometer testing. Also, BSFC with BDF 20 resulted in lower than with diesel fuel. The peak pressure with BDF 20 was higher than that with diesel fuel due to the oxygen content in BDF. And, BDF 20 resulted in lower emissions of carbon monoxide, carbon dioxide, and smoke emissions with a little increase of oxides of nitrogen than diesel fuel. It was concluded that there was no unusual deterioration of the engine, or any unusual change in exhaust emissions during the durability test of an IDI diesel engine using BDF 20.

A Study on the Tumble Flow Test Rig Used to Developing Engine Induction System (엔진 흡기시스템 개발 시 사용하는 텀블유동 시험장치의 고찰)

  • Yun, Jeong-Eui;Kim, Myung-Hwan;Nam, Hyeon-Sik;Min, Sun-Ki;Sim, Dae-Gon;Park, Pyeong-Wan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.184-189
    • /
    • 2006
  • Tumble flow test rig has been used as the useful tool in the developing intake system because major flow pattern induced by intake port of DOHC engine is tumble. Angular momentum of in-cylinder tumble flow can not be directly measured by impulse torque meter in the test rig like that of in-cylinder swirl flow due to rotational axis of the flow. Therefore the adaptor to transform tumble to swirl flow must be adapted in the test rig. In this study, using the commercial CFD code STAR-CD, we studied the effects on measured results due to the variation of the major design variables in the adaptor, tube length(L), tube diameter(D) and cylinder height(H). The effect of the attached angle($\theta$) of the test head to the adaptor also was simulated.

The Classification of the Schizophrenia EEG Signal using Hidden Markov Model (은닉 마코프 모델을 이용한 정신질환자의 뇌파 판별)

  • 이경일;김필운;조진호;김명남
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.217-225
    • /
    • 2004
  • In this paper, a new automatic classification method for the normal EEC and schizophrenia EEC using hidden Markov model(HMM) is proposed. We used the feature parameters which are the variance for statistical stationary interval of the EEC and power spectrum ratio of the alpha, beta, and theta wave. The results were shown that high classification accuracy of 90.9% in the case of normal person, and 90.5% in the case of schizophrenia patient. It seems that proposed classification system is more efficient than the system using complicate signal processing process. Hence, the proposed method can be used at analysis and classification for complicated biosignal such as EEC and is expected to give considerable assistance to clinical diagnosis.

A Study of Characteristics of lnxGa1-xP by Photoreflectance measurement (Photoreflectance 측정에 의한 InxGa1-xP의 특성 연구)

  • Kim D. L.;Yu J. I.
    • Laser Solutions
    • /
    • v.8 no.3
    • /
    • pp.5-10
    • /
    • 2005
  • [ $InxGa_{1-x}P/GaAs$ ] structures were grown by chemical beam epitaxy(CBE), Pure phosphine($PH_3$) gases were used as group V sources. for the group III sources, TEGa, TmIn were used. $InxGa_{1-x}P$ epilayer was grown on SI-GaAs substrate and has a 1-${\mu}m$ thick. We have investigated the characteristics of $InxGa_{1-x}P$ by the photoreflectance(PR) spectroscopy, The PR spectrum of $InxGa_{1-x}P$ shows third-derivative feature whose Peaks Provide energy gap. The energy gap of $InxGa_{1-x}P$ has deduced composition x. From temperature dependance of PR spectra, temperature coefficient is $dEg/dT=-3.773{\times}10^{-4}$ eV/K, and Varshni coefficients $\alpha$ and $\beta$ values obtained $4{\times}10^4$ eV/K and 267 K respectively. Also, interaction $\alpha$B was 19.4 meV using the Bose-Einstein temperature relation, and $\Theta$ value related the average phonon frequency were 101.4 K. In particular, shoulder peak related to defects observed in PR signal that measured in temperature 82 K.

  • PDF

Perception of the English Epenthetic Stops by Korean Listeners

  • Han, Jeong-Im
    • Speech Sciences
    • /
    • v.11 no.1
    • /
    • pp.87-103
    • /
    • 2004
  • This study investigates Korean listeners' perception of the English stop epenthesis between the sonorant and fricative segments. Specifically this study investigates 1) how often English epenthetic stops are perceived by native Korean listeners, given the fact that Korean does not allow consonant clusters in codas; and 2) whether perception of the epenthetic stops, which are optional phonetic variations, not phonemes, could be improved without any explicit training. 120 English non-words with a mono-syllable structure of CVC1C2, where C1=/m, n, $\eta$, 1/, and C2=/s, $\theta$, $\int$/, were given to two groups of native Korean listeners, and they were asked to detect the target stops such as [p], [t], and [k]. The number of their responses were computed to determine how often listeners succeed in recovering the string of segments produced by the native English speaker. The results of the present study show that English epenthetic stops are poorly identified by native Korean listeners with low English proficiency, even in the case where stimuli with strong acoustic cues are provided with, but perception of epenthetic stops is closely related with listeners' English proficiency, showing the possibility of the improvement of perception. It further shows that perception of epenthetic stops shows asymmetry between coronal and non-coronal consonants.

  • PDF

Wall Heat Conduction and Convection Heat Transfer from a Cylinder in Cross Flow (원형 실린더 주위의 전도-대류 열전달)

  • 이상봉;이억수;김시영
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.1-8
    • /
    • 2001
  • With uniform heat generation within the wall of the cylinder placed in a cross flow, heat flows by conduction in the circumferential direction due to the asymmetric nature of the fluid flow around the perimeter of the cylinder. The circumferential heat flow affects the wall temperature distribution to such an extent that in some cases significantly different results may be obtained for geometrically similar surfaces. In the present investigation, the effects of circumferential wall heat conduction on local convective heat transfer is investigated for the case of forced convection around horizontal cylinder in cross flow of air. Two-dimensional temperature distribution $T_w$/(${\gamma}$,${\theta}$) is presented through the numerical analysis. The one-dimensional and two-dimensional solutions are in good agreement with experimental results of local heat transfer coefficients.

  • PDF