• Title/Summary/Keyword: $Sol_0{^4}$

Search Result 787, Processing Time 0.033 seconds

Photocatalytic Degradation of Dibenzothiophene in Aqueous Phase (수중 Dibenzothiophene의 광촉매 분해에 관한 연구)

  • Jo, Sung-Hye;Yoe, Seok-Jun;Kim, Il-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.527-534
    • /
    • 2011
  • In this research, the photocatalytic degradation of dibenzothiophene (DBT) in $TiO_2$ aqueous suspension has been studied. $TiO_2$ photocatalysts are prepared by a sol-gel method. The dominant anatase-structure on $TiO_2$ particles is observed after calcining the $TiO_2$ gel at $500^{\circ}C$ for 1hr. Photocatalysts with various transition metals (Nd, Pd and Pt) loading are tested to evaluate the effect of transition metal impurities on photodegradation. The photodegradation efficiencies with $TiO_2$ including Pt and Pd are higher than pure $TiO_2$ powder. Also we investigated the applicability of $H_2O_2$ to increase the efficiency of the $TiO_2$ photocatalytic degradation of dibenzothiophene. The degradation efficiency increases with increasing dosage of $H_2O_2$ in the range of 0.01M to 0.1M . The effect of pH is investigated; we obtained the maximum photodegradation efficiency at pH 5. In addition, the intermediate analysis found dihydroxyl -dibenzothiophene as a reaction intermediate of dibenzothiophene during the photodegradation.

Effect of Composition and Coating of Precursor Solution on a Micro Structural Properties of PZT Thick Films (PZT 후막의 미세 구조적 특성에 조성과 전구체 용액의 코팅이 미치는 영향)

  • Park, Sang-Man;Noh, Hyun-Ji;Lee, Sung-Gap
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.11
    • /
    • pp.1014-1019
    • /
    • 2006
  • The influence of the number of solution coatings on the densification of the PZT thick films was studied. PZT powder and PZT precursor solution was prepared by a sol-gel method and PZT thick films were fabricated by the screen-printing method on the alumina substrates. The powder and solution of composition were (A) PZT(80/20)/PZT(20/80), (B) PZT(70/30)/PZT(30/70) and (C) PZT(60/40)/PZT(40/60), (D) PZT(52/48)/PT. The coating and drying procedure was repeated 4 times. And then the PZT precursor solution was spin-coated on the PZT thick films. A concentration of a coating solution was 0.5 moth and the number of coating was repeated from 0 to 6. The porosity of the thick films was decreased with increasing the number of coatings and the PZT thick films with 6-times coated showed the dense microstructure and thickness of about $60{\mu}m$. A grain size was increased with increasing the coating number. All PZT thick films showed the typical XRD patterns of a typical perovskite polycrystalline structure. The relative dielectric constant of PZT thick films was improved 30-100% as the number of coatings.

Properties of PZT(80/20) Thick Films with the Variation of the Number of Solution Coatings (Solution 코팅횟수에 따른 PZT(80/20)후막의 특성)

  • Park, Sang-Man;Lee, Sung-Gap;Lee, Young-Hi;Bae, Seon-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1418-1419
    • /
    • 2006
  • PZT(80/20) powder was prepared by a sol-gel method and PZT thick films were fabricated by the screen-printing method on the alumina substrates. The coating and drying procedure was repeated 4 times. And then the PZT(20/80) precursor solution was spin-coated on the multilayered thick films. A concentration of a coating solution was 0.5 mol/L and the number of coating was repeated from 0 to 6. The porosity of the thick films was decreased with increasing the number of coatings and the PZT thick films with 6-times coated showed the dense microstructure and thickness of about 60-65 ${\mu}m$. All PZT thick films showed the typical XRD patterns of a typical perovskite polycrystalline structure. The relative dielectric constant and the dielectric loss of the PZT-6 thick film were 275 and 3.5, respectively. And the PZT-6 film shows the remanent polarization of 22.1 $C/cm^2$ and coercive field of 13.7 kV/cm.

  • PDF

In-Situ Synthesis of PS/(-)Silica Composite Particles in Dispersion Polymerization Using An ($\pm$) Amphoteric Initiator

  • Hwang, Deok-Ryul;Hong, Jin-Ho;Lee, Jeong-Woo;Shim, Sang-Eun
    • Macromolecular Research
    • /
    • v.16 no.4
    • /
    • pp.329-336
    • /
    • 2008
  • Core/shell ($\pm$)PS/(-)silica nanocomposite particles were synthesized by dispersion polymerization using an amphoteric initiator, 2,2'-azobis [N-(2-carboxyethyl)-2,2-methylpropionamidine] ($HOOC(CH_2)_2HN$(HN=) $C(CH_3)_2CN$=NC $(CH_3)_2C$(=NH)NH $(CH_2)_2COOH$), VA-057. Negatively charged (-6.9 mV) silica was used as the stabilizer. The effects of silica addition time and silica and initiator concentrations were investigated in terms of polymerization kinetics, ultimate particle morphology, and size/size distribution. Uniform hybrid microspheres with a well-defined, core-shell structure were obtained at the following conditions: silica content = 10-15 wt% to styrene, VA-057 content=above 2 wt% to styrene and silica addition time=0 min after initiation. The delay in silica addition time retarded the polymerization kinetics and broadened the particle size distribution. The rate of polymerization was strongly affected by the silica content: it increased up to 15 wt% silica but then decreased with further increase in silica content. However, the particle size was only marginally influenced by the silica content. The zeta potential of the composite particles slightly decreased with increasing silica content. With increasing VA-057 concentration, the PS microspheres were entirely coated with silica sol above 1.0 wt% initiator.

Slug Characteristics in a Bubbling Fluidized Bed Reactor for Polymerization Reaction (기포유동층 고분자 중합 반응기에서의 슬러그 특성)

  • Go, Eun Sol;Kang, Seo Yeong;Seo, Su Been;Kim, Hyung Woo;Lee, See Hoon
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.651-657
    • /
    • 2020
  • Fluidization processes in which solid particles vividly move like gas or liquid have been widely used in various industrial sectors, such as thermochemical energy conversion and polymerization processes for general purpose polymer resins. One of the general purpose polymer resins, LLDPE(Linear low-density polyethylene) resins have been produced in bubbling fluidized bed processes in the world. In a bubbling fluidization polymerization reactors, LLDPE particles with relatively larger particle size and low density are fluidized by hydrogen gas for polymerization reaction. Though LLDPE polymerization reactors are one of bubbling fluidization processes, slugs that have negative impact for reaction exist or occur in these processes. Therefore, the fluidization state of LLDPE particles was investigated in a simulation model similar to a pilot-scale polymerization reactor (0.38 m l.D., 4.4 m High). In particular, the effect of gas velocity (0.45-1.2 m/s), solid density (900-199 kg/㎥), solid sphericity (0.5-1.0), and average particle size (120-1230 ㎛), on bed height and fluidization state were measured by using a CPFD(Computational particle-fluid dynamics) method. With CPFD analysis, the occurrence of a flat slug was visualized. Also, the change in particle properties, such as particle density, sphericity, and size, could reduce the occurrence of slug and bed expansion.

Comparison analysis of before and after use of periodontal instruments on strength and agility of hands (치주기구사용 전·후의 손의 근력 및 민첩성 비교분석)

  • Yoo, DooHan;Kyung, So-jin;Back, Eun-jeong;Oh, Hyeon-hoei;Won, Sol-hee;Jang, Sol;Chae, Na-ri;Kang, Kyung-hee
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.117-122
    • /
    • 2019
  • This study aimed to provide the basic data for the prevention of carpal tunnel syndrome by measuring and comparatively analyzing the changes in muscular strength, grasping force, and agility of hands before/after practice, targeting the dental hygiene students taking the scaling practice course. Targeting total 15 students(4th-year) of Dental Hygienics who had no problems with anatomical structure, muscular strength, grasping force, and senses of hands, the muscular strength, grasping force, and agility of hands were measured before/after the scaling practice. The collected data was processed by using the PASW Statistics 18.0(SPSS) Program. In the results of this study, the muscular strength and grasping force of hands were decreased after the practice compared to the ones before the practice. The agility of hands was increased after the practice compared to the one before the practice. Based on such results of this study, it would be necessary to avoid such exhausting hand gestures for scaling, and also to develop the preventive exercise to build up the strength of hands like stretching before/after scaling.

Colossal Magnetoresistance and Mossbauer Studies of La-Ca-Mn-O Compound Doped with $^{57}Fe$ ($^{57}Fe$를 미량 치환한 La-Ca-Mn-O의 초거대자기저항과 Mossbauer분광학연구)

  • 박승일;김성철
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.6
    • /
    • pp.335-340
    • /
    • 1998
  • Colossal magnetoresistance $La_{0.67}Ca_{0.33}Mn_{0.99}^{57}Fe_{0.01}O_3$ material has been produced by a metal-salt routed sol-gel process method. Magnetic properties of $La_{0.67}Ca_{0.33}Mn_{0.99}^{57}Fe_{0.01}O_3$ have been studied with x-ray diffraction, Rutherford back-scattering spectroscopy(RBS), vibrating sample magnetometer, and Mossbauer spectroscopy. Crystalline $La_{0.67}Ca_{0.33}Mn_{0.99}^{57}Fe_{0.01}O_3$ was perovskite cubic structure with a lattice parameter $a_0=3.868$\AA$$. And there was no appreciable change in the value of the lattice parameter when a small amount (x=0.01) of iron was added. However, Mossbauer and VSM data indicate the Curie temperature of the $La_{0.67}Ca_{0.33}Mn_{0.99}^{57}Fe_{0.01}O_3$ decreased from 282 to 270 k and also the saturation magnetization from 84 to 81 emu/g at 77 K. Mossbauer spectra of $La_{0.67}Ca_{0.33}Mn_{0.99}^{57}Fe_{0.01}O_3$ have been taken at various temperatures ranging form 4.2 K to room temperature. Analysis of $^{57}Fe$ Mossbauer data in terms of the local configurations of Mn atoms has permitted the influence of the magnetic hyperfine interactions to be monitored. The isomer shifts show that the charge state of all Fe ions are ferric. The magnetoresistance of $La_{0.67}Ca_{0.33}Mn_{0.99}^{57}Fe_{0.01}O_3$ was about 33 % at semiconductor-metal transition temperature $T_{SC-M}=250K$.

  • PDF

Differences in Treatment Outcomes According to the Insertion Method Used in Extracorporeal Cardiopulmonary Resuscitation: A Single-Center Experience

  • Han Sol Lee;Chul Ho Lee;Jae Seok Jang;Jun Woo Cho;Yun-Ho Jeon
    • Journal of Chest Surgery
    • /
    • v.57 no.3
    • /
    • pp.281-288
    • /
    • 2024
  • Background: Venoarterial extracorporeal membrane oxygenation (ECMO) is a key treatment method used with patients in cardiac arrest who do not respond to medical treatment. A critical step in initiating therapy is the insertion of ECMO cannulas. Peripheral ECMO cannulation methods have been preferred for extracorporeal cardiopulmonary resuscitation (ECPR). Methods: Patients who underwent ECPR at Daegu Catholic University Medical Center between January 2017 and May 2023 were included in this study. We analyzed the impact of 2 different peripheral cannulation strategies (surgical cutdown vs. percutaneous cannulation) on various factors, including survival rate. Results: Among the 99 patients included in this study, 66 underwent surgical cutdown, and 33 underwent percutaneous insertion. The survival to discharge rates were 36.4% for the surgical cutdown group and 30.3% for the percutaneous group (p=0.708). The ECMO insertion times were 21.3 minutes for the surgical cutdown group and 10.3 minutes for the percutaneous group (p<0.001). The factors associated with overall mortality included a shorter low-flow time (hazard ratio [HR], 1.045; 95% confidence interval [CI], 1.019-1.071; p=0.001) and whether return of spontaneous circulation was achieved (HR, 0.317; 95% CI, 0.127-0.787; p=0.013). Low-flow time was defined as the time from the start of cardiopulmonary resuscitation to the completion of ECMO cannula insertion. Conclusion: No statistically significant difference in in-hospital mortality was observed between the surgical and percutaneous groups. However, regardless of the chosen cannulation strategy, reducing ECMO cannulation time was beneficial, as a shorter low-flow time was associated with significant benefits in terms of survival.

Novel Sulfonated Poly(arylene ether sulfone) Composite Membranes Containing Tetraethyl Orthosilicate (TEOS) for PEMFC Applications (고분자 전해질형 연료전지를 위한 TEOS가 함유된 술폰화 폴리아릴렌에테르술폰 복합막의 제조 및 특성)

  • Lee, Keun-Kyu;Kim, Tae-Ho;Hwang, Taek-Sung;Hong, Young-Taik
    • Membrane Journal
    • /
    • v.20 no.4
    • /
    • pp.278-289
    • /
    • 2010
  • A series of composite membranes based on sulfonated poly(arylene ether sulfone) (SPAES) were prepared via addition of tetraethyl orthosilicate (TEOS) and solution casting method. The morphological structure, water uptake, proton conductivity of the resulting composite membranes were extensively investigated as function of the content of TEOS. By the sol-gel reaction, TEOS molecules were not completely converted to $SiO_2$ particles, but formed only oligomer-type. Also, EDS confirms that the resulting silicon dioxide was homogeneously distributed in the composite membranes. As the content of TEOS increased, the prepared membranes increased water uptake and proton conductivity at high temperature and low relative humidity condition. In particular, considerably high proton conductivity (0.015 S/cm) at $120^{\circ}C$ and 48%RH was demonstrated in the composite membrane containing 200% TEOS, which is 10 times greater than that of unmodified SPAES membrane. Also, the composite membranes were found to have enhanced thermal stability compared to the unmodified membrane.

The Change of the Near Eye Position according to the Spectacle and Contact Lens Wearing (안경과 콘택트렌즈 착용에 따른 근거리안위의 변화)

  • Han, Sun-Hee;Kim, Bong-Hwan;Kim, Hak-Jun;Park, Jun-Sung;Park, Hae-Been;Kim, Mi-Jeong;Park, Ju-Hyeong;Kim, Jin-Sol;Lee, Kyeong-Hoon;Kim, Jong-Hwan;Ha, Na-Ri
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.4
    • /
    • pp.435-443
    • /
    • 2015
  • Purpose. This study was to investigate comparison of the near eye position according to the spectacle and contact lens wearing. Methods. We measured the AC/A ratio and near horizontal phoria using modified Thorington method in each case spectacle and contact lens wearing of equivalent spherical power after measuring the full corrected diopter for 20 subjects (men 5, woman 15, $21.15{\pm}1.35$ years) without specific ocular diseases, ocular surgery experience and vision anomalies. Results. It was shown high correlation between spectacle and contact lens wearing as AC/A ratio is a correlation coefficient 0.99 (p=0.00), near horizontal phoria is a correlation coefficient 0.95 (p=0.00). And contact lens wearing increased as AC/A ratio by $0.32{\pm}1.35$ ${\Delta}/D$ (p=0.31) and near horizontal phoria by $-0.17{\pm}2.18$ ${\Delta}$ (p=0.73) than spectacle wearing but there was no statistically significant difference. As the higher myopic grade AC/A ratio increased and then was shown decreased tendency in -6.00 D < $SED{\leq}-4.00$ D group (p>0.05) and as the higher myopic grade near exophoria increased but there was no statistically significant difference (p>0.05). Conclusions. We should consider that the subjects who had the lower AC/A ratio or higher near exophoria in -6.00 D < $SED{\leq}-4.00$ D group were necessary to measure AC/A ratio and near horizontal phoria when they were wearing contact lens because contact lens wearing tended to increase the near exophoria than spectacle wearing.