• 제목/요약/키워드: $PM_{over-10}$

검색결과 2,168건 처리시간 0.028초

Effect of Inhaled Tiotropium on Spirometric Parameters in Patients with Tuberculous Destroyed Lung

  • Yum, Ho-Kee;Park, I-Nae
    • Tuberculosis and Respiratory Diseases
    • /
    • 제77권4호
    • /
    • pp.167-171
    • /
    • 2014
  • Background: In Korea, patients with destroyed lung due to tuberculosis (TB) account for a significant portion of those affected by chronic pulmonary function impairment. The objective of our research was to evaluate the efficacy of inhaled tiotropium bromide in TB destroyed lung. Methods: We compared the effectiveness of inhaled tiotropium bromide for 2 months between pre- and post-treatment pulmonary function tests performed on 29 patients with destroyed lung due to TB. Results: The mean age of the total number of patients was $63{\pm}9$ years, where 15 patients were male. The pre-treatment mean forced expiratory volume in 1 second ($FEV_1$) was $1.02{\pm}0.31L$ ($44.1{\pm}16.0%$ predicted). The pre-treatment mean forced vital capacity (FVC) was $1.70{\pm}0.54L$ ($52.2{\pm}15.8%$ predicted). Overall, the change in $FEV_1%$ predicted over baseline with tiotropium was $19.5{\pm}19.1%$ (p<0.001). Twenty patients (72%) got better than a 10% increase in $FEV_1$ over baseline with tiotropium, but one patient showed more than a 10% decrease in $FEV_1$. Overall, the change in FVC% predicted over baseline with tiotropium was $18.5{\pm}19.9%$ (p<0.001). Seventeen patients (59%) experienced greater than a 10% increase in FVC over baseline with tiotropium; 12 (41%) patients had stable lung function. Conclusion: The inhaled tiotropium bromide therapy may lead to improve lung functions in patients with TB destroyed lung. However, the long-term effectiveness of this treatment still needs to be further assessed.

천연 다당류 먼지포집제를 이용한 지하철 터널 내 PM10 제어에 대한 연구 (A Study on PM10 Control in Subway Tunnels Using Natural Polysaccharide Dust Collecting Agent)

  • 이한섭;황수진;황현석
    • 한국환경보건학회지
    • /
    • 제43권2호
    • /
    • pp.122-129
    • /
    • 2017
  • Objectives: Most of the $PM_{10}$ in subway stations is spread by the train-induced wind from the tunnels. Therefore, in order to improve air quality in subway stations, it is important to remove the $PM_{10}$ from the tunnels. After the installation of PSD (platform screen doors), the influence of train-induced wind and $PM_{10}$ at the platform has decreased, but is estimated to have increased in subway tunnels. This study was conducted to investigate the control of $PM_{10}$ in subway tunnels by applying a 500-fold diluted solution mixed with a humectant using a natural polymer. Methods: For this purpose, we tested the dust reduction effect in a laboratory and corrosion test and water pollution using fish and aquatic plants for the natural dust collecting agent. In the tunnel of a subway station, we used the natural dust collecting agent over 15 days. The study was carried out on $PM_{10}$ control during operation, which accounts for more than 70% of subway dust. Results: As results, the natural dust collecting agent exhibited an excellent dust control effect, and it was safe for water quality and soil. It showed the effect of controlling $PM_{10}$ in the subway tunnel by 49.5- 64.7% over 15 days. The use of the dust collecting agent for the control of $PM_{10}$ could be confirmed in the subway. Conclusion: It is necessary to clearly explain the major portions of chemical components contained in $PM_{10}$ to figure out the characteristics of $PM_{10}$ and to develop effective reduction measures to decrease the adverse effects of $PM_{10}$ in the subway.

산란광 광량 적산시 Digital Dust Indicator에 의한 도서관과 학생회관내 $PM_{10}$ 농도의 일변화 (Diurnal Variation of $PM_{10}$ Concentrations in Library and Student Buildings using Scattering Light Integrated Type Digital Dust Indicator)

  • 김만구;권영진;정영림
    • 한국대기환경학회지
    • /
    • 제13권2호
    • /
    • pp.115-122
    • /
    • 1997
  • Diurnal variation of $PM_{10}$ concentration was investigated for 24 sites in library including reading room, bookstock room, lobby, office and so on, and 9 sites in student building at Kangwon National University using scattering light integrated type digital dust indicator. The dimensional conversion factors for mass concentrations (K) were determined by comparing between the $PM_{10}$ concentrations collected by $PM_{10}$ hig volume air sampler and the digital dust indicator. The dimensional conversion factor (K) was 3.33 for indoor air in this experiment. The highest concentrations were 649 $\mug/m^3$/day for smoking room in the library and 242 $\mug/m^3$/day for circle room in the student building. Most of spaces in the library except a office and bookstock rooms were over 150 $\mug/m^3$/day of $PM_{10}$ concentrations and 6 indoor spaces were over the guideline for indoor air quality in student building except a health center and two restaurants. Therefore, it should be required to make an improvement on the indoor air quaility for public facilities in the university buildings.

  • PDF

시정자료를 이용한 황사의 미세먼지 농도추정 방법 연구 (Study of Methodology for Estimating PM10 Concentration of Asian Dust Using Visibility Data)

  • 이효정;이은희;이상삼;김승범
    • 대기
    • /
    • 제22권1호
    • /
    • pp.13-28
    • /
    • 2012
  • The $PM_{10}$ concentration data is useful for indentifying intensity and a transport way of Asian dust. However, it is difficult to identify them properly due to the limited spatial resolution and coverage. Therefore, a methodology to estimate $PM_{10}$ concentration using visibility data obtained from synoptic observation was developed. To derive the converting function, correlation between visibility and $PM_{10}$ concentration is investigated using visibility and $PM_{10}$ concentration data observed at 20 stations in Korea from 2005 to 2009. To minimize bias due to atmospheric moisture, data with higher relative humidity over a critical value were eliminated while deriving $PM_{10}$-visibility relationship. As a result, an exponentially decreasing function of visibility is obtained under the condition that relative humidity is less than 82%. Verification of the visibility converting function to $PM_{10}$ concentration was carried out for the dust cases in 2010. It was found that spatial distributions of $PM_{10}$ calculated by visibility are in good agreement with the observed $PM_{10}$ distribution, especially for the strong dust cases in 2010. And correlation between the derived and observed $PM_{10}$ concentration was 0.63. We applied the function to obtain distributions of $PM_{10}$ concentration over North Korea, in which concentration data are not available, and compared them with satellite derived dust index, IODI distributions for dust cases in 2010. It is shown that the visibility function estimates quite similar patterns of dust concentration with IODI image, which suggests that it can contribute for prediction by indentifying transport route of Asian dust.

Perturbation of Background Atmospheric Black Carbon/PM1 Ratio during Firecracker Bursting Episode

  • Majumdar, Deepanjan;Gavane, Ashok Gangadhar
    • Asian Journal of Atmospheric Environment
    • /
    • 제11권4호
    • /
    • pp.322-329
    • /
    • 2017
  • Perturbation in ambient particulate matter ($PM_1$, $PM_{2.5}$, $PM_{10}$) and black carbon (BC) concentrations was studied during a firecracker bursting episode in Diwali (Festival of Lights) celebrations in Nagpur, India. Firecracker bursting resulted in greater escalation in fine particulates over coarse particulates while $PM_{2.5}$ was found to be dominated by $PM_1$ concentration. On the Diwali day, daily mean concentration of $PM_{2.5}$ and $PM_{10}$ exceeded Indian National Ambient Air Quality Standards by over 1.8 and 1.5 times, respectively, while daily mean BC concentration on the same day was almost two times higher than the previous day. The BC/$PM_1$ ratio reduced remarkably from about 0.26 recorded before fire-cracker bursting activity to about 0.09 during fire-cracker bursting on Diwali night in spite of simultaneous escalation in ambient BC concentration. Such aberration in BC/$PM_1$ was evidently a result of much higher escalation in $PM_1$ than BC in ambient air during firecracker bursting. The study highlighted strong perturbations in ambient $PM_1$, $PM_{2.5}$, $PM_{10}$ concentrations and BC/$PM_1$ during the firecracker bursting episode. Altered atmospheric BC/$PM_1$ ratios could serve as indicators of firecracker-polluted air and similar BC/$PM_1$ ratios in local and regional air masses might be used as diagnostic ratios for firecracker smoke.

Brute-force 방법을 이용한 한반도 미세먼지 농도에 대한 배출원의 기여도 산출 연구 (Evaluation of Contribution Rate of PM Concentrations for Regional Emission Inventories in Korean Peninsula Using Brute-force Sensitivity Analysis)

  • 이순환;이강열
    • 한국환경과학회지
    • /
    • 제24권11호
    • /
    • pp.1525-1540
    • /
    • 2015
  • In order to clarify the contribution rate of PM concentration due to regional emission distribution, Brute force analysis were carried out using numerical estimated PM data from WRF-CMAQ. The emission from Kyeongki region including Seoul metropolitan is the largest contribution of PM concentration than that from other regions except for emission of trans-country and source itself. Contribution rate of self emission is also the largest at Kyeongki region and its rate reach on over 95 %. And the rate at Gangwon region also higher than any region due to synoptic wind pattern. Due to synoptic wind direction at high PM episode, pollutants at downwind area along from west to east and from north to south tends to mix intensively and its composition is also complicated. Although the uncertainty of initial concentration of PM, the contribution of regional PM concentration tend to depend on the meteorological condition including intensity of synoptic and mesoscale wind and PM emission pattern over upwind region.

2002년 부산지역 봄철 황사/비황사시 PM10 중의 중금속 농도 특성 (Characteristics of Heavy Metallic Elements of PM10 for Yellow sand and Non-Yellow sand during Springtime of 2002 at Busan)

  • 전병일
    • 환경영향평가
    • /
    • 제12권2호
    • /
    • pp.99-108
    • /
    • 2003
  • We collected and analyzed PM10 samples to account for the characteristics of heavy metallic elements for yellow sand and non-yellow sand during springtime of 2002 at Busan, The mean PM10 mass concentration for springtime of 2002 was $219.82{\mu}g/m^3$ with the maximum $787.50{\mu}g/m^3$ and the minimum $19.44{\mu}g/m^3$. The mean concentration of metallic elements contained in PM10 are shown as follows : Si>Ca>Fe>Al>Na, respectively. The ratio of mean PM10 mass concentration for yellow sand($362.7{\mu}g/m^3$) to that for non-yellow sand($48.3{\mu}g/m^3$) was 7.5, the significant positive correlation (P<0.05) was found between yellow sand and non-yellow sand. The metallic elements concentration ratios of yellow sand to the non-yellow sand were over 10 times for Al, Ca, Mg, 4~8 times for Fe, Si, Mn. But the concentration of Na, Cu, Zn for non-yellow sand was higher than those of yellow sand. The crustal enrichment factor of Cd, Cu, Pb, Zn, Cr, K, Mn, Na, Ni for yellow sand was higher that of non-yellow sand over 10 times, and concentration rate of soil particles of yellow sand was increased 2.3 times that of nonyellow sand.

저장 조건에 따른 시유의 품질변화 (Changes on the Quality of Market Milk on the Storage Conditions)

  • 이수원;황보식
    • 한국축산식품학회지
    • /
    • 제21권2호
    • /
    • pp.156-162
    • /
    • 2001
  • The quality changes of UHT market milk product were investigated by the season and storage conditions. Throughout the year, standard plate counts(SPC) wasnt increased significantly during storage at 5$\pm$1 and 7$\pm$1$^{\circ}C$ for 10 days. And except for summer, SPC was lower than 20,000 cfu/ml after storage at 10$\pm$1$^{\circ}C$ or 10 days. But SPC was rapidly increased from 3 days at 15$\pm$1$^{\circ}C$, and there was gas forming by yeast growth after storage at 30$\pm$1$^{\circ}C$. Values of pH and titratable acidity of market milk products were 6.49 to 6.71 and 0.155 to 0.16%, respectively. pH and titratable acidity were a lot changes at the temperature over 15$\pm$1$^{\circ}C$, and milk products showed a curd at 30$\pm$1$^{\circ}C$. Carbohydrate of market milk product had little difference throughout the year, whereas fat, protein and total solids of market milk products in autumn showed a little higher value than that of other seasons. There were no changes of milk composition during storage periods, but carbohydrate was decreased a little after storage over 20$\pm$1$^{\circ}C$.

  • PDF

KZ 필터법을 이용한 서울지역 미세먼지 농도의 장기변화 분석 (Long Term Analysis of PM10 Concentration in Seoul Using KZ Filter)

  • 이정영;공부주;한진석;이민도
    • 한국대기환경학회지
    • /
    • 제24권1호
    • /
    • pp.63-71
    • /
    • 2008
  • Local meteorological conditions exert a strong influence over day-to-day variations in air pollutant concentrations. Therefore, the meteorological fluctuations have to be removed in order for air quality planners and managers to examine underlying emissions-related trends and make better air quality management decisions for future. In this study, the meteorologically adjusted $PM_{10}$ trends in Seoul are investigated over the period $1999{\sim}2006$ using Kolmogorov-Zurbenco (KZ) filter. The result indicated that meteorologicaJ variability accounts for about 25% of $PM_{10}$ variability. Both the meteorologically adjusted and unadjusted Jong-term daily $PM_{10}$ concentrations had a significant downward trends and the difference between the meteorologically adjusted and unadjusted was small. So it was assumed that in long-term daily $PM_{10}$ changes, localized changes in emissions is more important than the changes caused by meteorological conditions.

익산지역에서 황사발생시 PM2.5, PM10 TSP의 농도 특성 (Concentration Characteristics of Atmospheric PM2.5, PM10 and TSP during the Asian Dust Storm in Iksan Area)

  • 강공언;김남송;김경숙;김미경;이현주
    • 한국환경보건학회지
    • /
    • 제33권5호
    • /
    • pp.408-421
    • /
    • 2007
  • The concentration characteristics of atmospheric particle matters (PM) including $PM_{2.5},\;PM_{10}$, and TSP were evaluated through the measurement data of PM_{2.5}$ (fine particulate), PM_{10-2.5}$ (coarse particulate), and PM_{over-10}$ collected using a MCI (multi-nozzle cascade impactor) sampler of a three-stage filter pack in spring of 2006 in Iksan area. During the sampling period of 10-15 March and 24 days from 8 April to 2 May, 32 samples for PM of each size fractions were collected, and then measured for PM mass concentrations and water-soluble inorganic ion species. Average concentrations of $PM_{2.5},\;PM_{10}$, TSP were $57.9{\pm}44.1mg/m^3$, $96.6{\pm}89.1mg/m^3$, and $114.8{\pm}99.7mg/m^3$, respectively. Water-soluble inorganic ion fractions to PM mass were found to be 36.5%, 18.0%, and 11.1% for $PM_{2.5}$, $PM_{10-2.5}$ and $PM_{over-10}$, respectively. By showing the high concentrations of PM samples during Asian dust events, those three fractions of PM were distinguished between the samples of Asian dust event and the samples of no event. However, the increase of PM concentrations observed during Asian dust events showed a different pattern for some Asian dust events. The differences of those three fractions in the size distribution may depend on differences on place of occurrence of Asian dust storm and course of transport from China continent to Iksan area in Korea. However, the extent of PM mass contribution during Asian dust events was generally dominated by the coarse particles rather than the fine fraction of PM. The variations of water-soluble inorganic ion species concentration in those three PM fractions between the samples of Asian dust event and the samples of no event were also discussed in this study.