• 제목/요약/키워드: $PM_{10}$ and $PM_{2.5}$ concentration

검색결과 2,039건 처리시간 0.038초

서울지역 미세먼지 농도가 호흡기계 및 심혈관계의 외래 방문 및 입원과 진료비에 미치는 영향 (Hospital Visits, Admissions and Hospital Costs among Patients with Respiratory and Cardiovascular Diseases according to Particulate Matter in Seoul)

  • 이형숙
    • 한국환경보건학회지
    • /
    • 제42권5호
    • /
    • pp.324-332
    • /
    • 2016
  • Objectives: The annual average of PM10 in Seoul was $45{\mu}/m^3$, which surpasses the WHO annual guidelines ($20{\mu}/m^3$). Most previous analyses of the effects of PM exposure have been retrospective studies using single hospital data, and fewer studies have attempted to address the relationship of PM10 and hospital costs. This study was conducted to investigate the effects of the concentration of PM10 on hospital visits, admissions and hospital costs in patients with respiratory and cardiovascular diseases. Methods: Medical data from the National Health Insurance Service and the monthly average of PM10 from National Institute of Environmental Research were used to identify the effects of PM10 on hospital visits, admissions and hospital costs. We applied Poisson regression and linear regression to perform the analysis. Results: The relative risks for admissions per $10{\mu}/m^3$ increase in PM10 were 23.11%, 10.2% and 6.9% increases for acute bronchiolitis, asthma and bronchitis, respectively. The relative risk for hospital visits per $10{\mu}/m^3$ increase in PM10 were 10.4%, 6.7% and 5.9% for chronic obstructive pulmonary disease, asthma and chronic sinusitis, respectively. For cardiovascular disease, the relative risk for admissions per $10{\mu}/m^3$ increase in PM10 were 2.2% and 2.1% increases in angina and acute myocardial infarction, respectively. A $10{\mu}/m^3$ increase in the monthly average of PM10 corresponded to 170,723,000 won (95% CI: 125,587,000-215,860,000 won), 123,636,000 won (95% CI: 47,784,000-199,487,000 won) and 78,571,000 won (95% CI: 29,062,000-128,081,000 won) increases in hospital costs for asthma, acute tonsillitis and chronic sinusitis, respectively. Conclusion: Hospital admissions for respiratory and cardiovascular disease were associated with PM10 levels. PM10 exposure is also associated with increased costs for respiratory diseases.

동아시아 지역의 계절별 기상패턴에 따른 우리나라 PM2.5 농도 및 기여도 특성 분석: 2015년 집중측정 기간을 중심으로 (Analysis of PM2.5 Concentration and Contribution Characteristics in South Korea according to Seasonal Weather Patternsin East Asia: Focusing on the Intensive Measurement Periodsin 2015)

  • 남기표;이대균;장임석
    • 환경영향평가
    • /
    • 제28권3호
    • /
    • pp.183-200
    • /
    • 2019
  • 본 연구에서는 지상 $PM_{2.5}$ 측정 자료와 일기도 자료, WRF 및 CMAQ 모델을 활용하여 동북아시아 지역의 계절별 $PM_{2.5}$ 거동특성을 분석하였으며, 대기질 모델에 BFM을 적용하여 우리나라 $PM_{2.5}$ 농도에 대한 계절별 국내외 기여도를 평가하였다. 일기도 자료를 기반으로 국내 $PM_{2.5}$ 측정 자료 및 대기질 모사결과를 통해 $PM_{2.5}$의 거동특성을 분석한 결과, 동북아 지역에서의 $PM_{2.5}$는 장거리 수송된 대기오염 물질의 유입 및 대기정체 현상에 기인한 농도의 증가 또는 깨끗한 공기의 유입에 따른 농도의 감소 등의 특징이 계절별 종관기상 특성에 따라 상이하게 나타났다. 대기질 모델에 BFM (Brute-Force Method)을 적용하여 우리나라 6개 집중측정소 지점의 $PM_{2.5}$ 농도에 대한 국내외 기여도 평가를 수행한 결과, 백령도 지역은 낮은 자체 배출량과 동시에 중국으로부터 인접한 지리적 특성으로 인해 국외로부터의 기여가 지배적인 영향을 미치는 것으로 나타났다. 반면, 서울, 울산과 같이 높은 자체 배출량 특성을 나타내는 지역의 경우, $PM_{2.5}$에 대한 국외 기여도는 타 지역에 비해 상대적으로 낮게 나타남과 동시에 계절에 따른 기여도의 표준편차는 상대적으로 높게 나타나는 특징을 보였다. 본 연구는 우리나라를 중심으로 계절별 기상조건 변화에 따른 동북아 지역의 $PM_{2.5}$ 거동특성을 분석하여 국내 대기오염물질 현상에 대한 이해를 증진함과 동시에, 지역 배출특성에 따라 $PM_{2.5}$ 농도에 대한 국내외 기여도는 상이할 수 있음을 알려 향후 대기질 개선 대책 수립시 기초자료로 활용될 수 있을 것으로 기대된다.

Ambient Fine and Ultrafine Particle Measurements and Their Correlations with Particulate PAHs at an Elementary School Near a Highway

  • Song, Sang-Hwan;Paek, Do-Myung;Lee, Young-Mee;Lee, Chul-Woo;Park, Chung-Hee;Yu, Seung-Do
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권2호
    • /
    • pp.96-103
    • /
    • 2012
  • Ambient particulate matter (PM) and particle-bound polycyclic aromatic hydrocarbon (PAH) concentrations were measured continuously for 70 days at a Korean elementary school located near a highway. The $PM_{10}$, $PM_{2.5}$, and $PM_1$ values were measured with a light-scattering, multi-channel, aerosol spectrometer (Grimm, Model 1.107). The number concentrations of the particles were measured using a scanning mobility particle sizer and counter (SMPS+C) which counted particles from 11.1 to 1083.3 nm classified in 44 channels. Particle-bound PAHs were measured with a direct reading, photoelectric aerosol sensor. The daily $NO_2$, $SO_2$, and CO concentrations were obtained from a national air-monitoring station located near the school. The average concentrations of $PM_{10}$, $PM_{2.5}$, and $PM_1$ were 75.3, 59.3, and $52.1{\mu}g/m^3$, respectively. The average number concentration of the ultrafine particles (UFPs) was $46,307/cm^3$, and the averaged particle-bound PAHs concentration was $17.9ng/cm^3$ during the study period. The ambient UFP variation was strongly associated with traffic intensity, particularly peak concentrations during the traffic rush hours. Particles <100 nm corresponded to traffic-related pollutants, including PAHs. Additional longterm monitoring of ambient UFPs and high-resolution traffic measurements should be carried out in future studies. In addition, transient variations in the ambient particle concentration should be taken into consideration in epidemiology studies in order to examine the short-term health effects of urban UFPs.

Exposure to Atmospheric Particulates and Associated Respirable Deposition Dose to Street Vendors at the Residential and Commercial Sites in Dehradun City

  • Prabhu, Vignesh;Gupta, Sunil K.;Madhwal, Sandeep;Shridhar, Vijay
    • Safety and Health at Work
    • /
    • 제10권2호
    • /
    • pp.237-244
    • /
    • 2019
  • Background: Street vendors spend relatively more time near roadways and are vulnerable to air pollution related health disorders. However, there is limited information on the quality of the air they breathe. The objectives of this present study were to calculate the mass concentration of atmospheric particulate matter (PM) in eight size fractions ($PM_{0.4-0.7}$, $PM_{0.7-1.1}$, $PM_{1.1-2.1}$, $PM_{2.1-3.3}$, $PM_{3.3-4.7}$, $PM_{4.7-5.8}$, $PM_{5.8-9.0}$, and $PM_{9.0--0{\mu}m}$) at commercial (CML) and residential site (RSL) in Dehradun city from November 2015 to May 2016. To estimate the corresponding respiratory deposition dose (RDDs) in alveolar (AL), tracheobronchial (TB), and head airway (HD) region on street vendors working at CML and RSL. To find the association of atmospheric PM with RDDs and the incidence of respiratory related disorders among street vendors. Methods: Andersen cascade impactor was employed for calculating the PM mass concentration. Questionnaire based health survey among street vendors were carried out through personal interview. Results: A significant difference (p < 0.05; t-test) between the mean $PM_{0.4-10{\mu}m}$ mass concentration at CML and RSL was observed with ($mean{\pm}SD$) $84.05{\pm}14.5$ and $77.23{\pm}11.7{\mu}g\;m^{-3}$, respectively. RDDs in AL, TB and HD region at CML was observed to be 9.9, 7.8, and 7.3% higher than at RSL, respectively. Health survey revealed 1.62, 0.96, 0.04, and 0.57 times higher incidence of cold, cough, breathlessness, and chest pain, respectively with street vendors at CML compared to RSL. Conclusion: The site characteristics plays a major role in the respiratory health status of street vendors at Dehradun.

잡견에서 분리폐관류 방법으로 투여된 고농도 cisplatin의 페독성에 관한 연구 (A Study on Pulmonary Toxic Effect of High-Dose Cisplatin Administered by Isolated Lung Perfusion in Dogs)

  • 김관민;한정호;김주현
    • Journal of Chest Surgery
    • /
    • 제33권9호
    • /
    • pp.697-706
    • /
    • 2000
  • Background: Isolated lung perfusion(ILP) was developed as a new treatment approach to non-resectable primary or metastatic lung cancer, because of its ability to reduce systemic toxicity while delivering high-dose chemotherapeutic agents to the target organs. This research was planned to evaluate the direct toxic effect of high-dose cisplatin to the lung tissue during isolated lung perfusion. Material and Method: Fifteen mongrel dogs were divided in the perfusate for 40 minutes. The second group was composed of 5 mongrel dogs which underwent ILP with cisplatin 2.5 mg/Kg added to the perfusate for 30 minutes and 10 minutes with washing solution without cisplatin. The third group underwent the same procedure as the second group except cisplatin 5.0 mg/Kg in the perfusate. Activities of serum angiotensin converting enzyme(ACE), tumor necrosis factor-$\alpha$(TNF-$\alpha$), and concentration of serum lactate dehydrogenase(LDH) and blood urea nitrogen/creatinine (BUN/Cr) were analyzed in each groups at the time of pre-perfusion, 1 hour, 1 day, 1 week, and 2 weeks after ILP. Result: Serum ACE activities before and 1 hour, 1 day, 1 week, and 2 weeks after ILP in control group were 45.1$\pm$6.3, 44.6$\pm$9.3, 46.7$\pm$9.5, 50.8$\pm$9.1, 46.1$\pm$4.3 U/L. Those in cisplatin 2.5 and 5.0 mg/Kg groups were 49.4$\pm$12.6, 39.0$\pm$8.6, 42.3$\pm$15.9, 50.0$\pm$2.6, 53.8$\pm$8.3 and 55.5$\pm$12.3, 47.0$\pm$6.3, 45.1$\pm$6.9, 74.8$\pm$19.5, 60.2$\pm$12.0 U/L, respectively. Serum TNF-$\alpha$ activities in each group before and after ILP were 5.0$\pm$1.5 / 7.7$\pm$2.2 / 6.6$\pm$2.5 / 4.3$\pm$1.3 / 5.2$\pm$1.1(control), 8.7$\pm$1.6 / 9.9$\pm$2.2 / 7.9$\pm$1.5 / 6.3$\pm$2.2 / 7.4$\pm$2.4 (cisplatin 2.5 mg/Kg), and 6.9$\pm$0.7 / 8.9$\pm$3.4 / 7.9$\pm$4.0 / 3.3$\pm$0.9 / 5.8$\pm$1.3 pg/ml(cisplatin 5.0 mg/Kg). Mean LDH levels of each group were 225.7 / 271.3 / 328.9 / 350.8 / 255.7(control), 235.7 / 265.7 / 336.0 / 379.5 / 299.2 (cisplatin 2.5 mg/Kg), and 259.6 / 285.2 / 340.6 / 433.4 / 292.4 IU/L(cisplatin 5.0 mg/Kg). So there was no significant difference in serum ACE, TNF-$\alpha$, and LDH activity changes after ILP between the 3 groups. And, there was no significant changes in BUN/Cr in each groups, which was independent of ILP and perfused concentration of cisplatin. In addition, all dogs survived the ILP and there was no significant evidence of pulmonary vascular injury after 2 weeks of ILP with cisplatin. Conclusion: There was no harmful effect of cisplatin to the lund tissue of the mongrel dog up to 5.0 mg/Kg in perfusate. Therefore, it is perceived to be safe and effective to deliver high-dose cisplatin to the lung without pulmonary toxicity and renal damage with ILP.

  • PDF

금연정책 시행이 전국 PC방의 간접흡연에 미치는 영향 (Impact of the Smoke-free Law on Secondhand Smoke in Computer Game Rooms)

  • 곽수영;이기영;김성렬;김성천;양원호;하권철
    • 한국환경보건학회지
    • /
    • 제41권1호
    • /
    • pp.11-16
    • /
    • 2015
  • Objectives: This study assessed the impact of the smoke-free law on secondhand smoke exposure in computer game rooms by measuring concentrations of particulate matter smaller than $2.5{\mu}m$($PM_{2.5}$). Methods: Indoor $PM_{2.5}$ concentrations were measured in 56 (during the smoke-free guidance period) and 118 computer game rooms (after the law went into effect) in four cities (Seoul, Cheonan, Daegu and Kunsan) in Korea. The number of smokers in the computer game rooms was also counted every five minutes. Results: Although a smoking ban had been implemented nationally, smoking was observed in 47% of the computer game rooms. Smoking density decreased from 1.62 persons per $100m^3$ during the guidance period to 0.32 persons per $100m^3$ after the smoke-free law. There is no statistically significant difference of $PM_{2.5}$ concentrations before and after the smoking ban. The $PM_{2.5}$ concentration was two times higher than the US NAAQS of $35{\mu}g/m^3$. The $PM_{2.5}$ concentration in computer game rooms without smokers was two times higher than the outdoor concentration. Conclusion: The smoke-free law in computer game rooms was complied with, even after the guidance period, in Korea. Indoor $PM_{2.5}$ concentration after smoke-free law implementation was high due to this non-compliance. High $PM_{2.5}$ concentration in computer game rooms without smokers might be due to smoking booths. The complete prohibition of smoking in computer game rooms should be implemented to protect patrons from secondhand smoke exposure.

광주지역 PM2.5의 고농도 오염현상 조사 (Investigation of PM2.5 Pollution Episodes in Gwangju)

  • 유근혜;조성용;배민석;이권호;박승식
    • 한국대기환경학회지
    • /
    • 제31권3호
    • /
    • pp.269-286
    • /
    • 2015
  • 24-hr integrated $PM_{2.5}$ measurements were performed between December 2013 and October 2014 at an urban site in Gwangju and the collected samples were analyzed for organic carbon (OC), elemental carbon (EC), ionic species, and elemental species. Objectives of this study were to identify $PM_{2.5}$ pollution episodes, to characterize their chemical components, and to examine their probable origins. Over the course of the study period, average $PM_{2.5}$ concentration was $37.7{\pm}23.6$ $(6.0{\sim}121.5){\mu}g/m^3$. Concentrations of secondary ionic species; $NH_4{^+}$, $NO_3{^-}$, and $SO_4{^{2-}}$ was on average $5.54{\mu}g/m^3$ (0.28~ 20.86), $7.60{\mu}g/m^3$ (0.45~ 33.53), and $9.05{\mu}g/m^3$ (0.50~ 34.98), accounting for 13.7% (4.6~ 22.7), 18.6% (2.9~ 44.8), and 22.9% (4.9~ 55.1) of the $PM_{2.5}$ concentration, respectively. Average OC and EC concentrations were $5.22{\mu}g/m^3$ and $1.54{\mu}g/m^3$, taking possession of 4.6 and 22.2% (as organic mass) of the $PM_{2.5}$, respectively. Frequencies at which 24-hr averaged $PM_{2.5}$ exceeded a 24-hr averaged Korean $PM_{2.5}$ standard of $50{\mu}g/m^3$ (termed as an "episode" in this study) were 30, accounting for 21.3% of total 141 measurements. These pollution episodes were mostly associated with haze phenomenon and weak surface wind speed. It is suggested that secondary formation of aerosol was one important formation mechanism of the episodes. The episodes were associated with enhancements of organic mass, $NO_3{^-}$ and $SO_4{^{2-}}$ in winter, of $NO_3{^-}$ and $SO_4{^{2-}}$ in spring, and of $SO_4{^{2-}}$ in summer. Potential source contribution function results indicate also that $PM_{2.5}$ episodes were likely attributed to local and regional haze pollution transported from northeastern China in winter, to atmospheric processing of local emissions rather than long-range transport of air pollutants in spring, and to the $SO_4{^{2-}}$ driven by photochemistry of $SO_2$ in summer.

Evaluation on the Potential of 18 Species of Indoor Plants to Reduce Particulate Matter

  • Jeong, Na Ra;Kim, Kwang Jin;Yoon, Ji Hye;Han, Seung Won;You, Soojin
    • 인간식물환경학회지
    • /
    • 제23권6호
    • /
    • pp.637-646
    • /
    • 2020
  • Background and objective: The main objective of this study is to measure the amount of particulate matter (PM) reduction under different characteristics of leaves in 18 different species of indoor plants. Methods: First, a particular amount of PM was added to the glass chambers (0.9×0.86×1.3 m) containing the indoor plant (height = 40 ± 20 cm), and the PM concentration were measured at 2-hour intervals. The experiment with the same conditions was conducted in the empty chamber as the control plot. Results: The range of PM reduction per unit leaf area of 18 species of experimental plants was 3.3-286.2 ㎍·m-2 leaf, total leaf area was 1,123-4,270 cm2, and leaf thickness was 0.14-0.80 mm and leaf size 2.27-234.47 cm2. As time passed, the concentration of PM decreased more in the chamber with plants than in the empty chamber. Among the 18 indoor plants, the ones with the greatest reduction in PM2.5 in 2 hours and 4 hours of exposure to PM2.5 were Pachira aquatica and Dieffenbachia amoena. As the exposure time of PM increased, the efficiency of reducing PM2.5 was higher in plants with medium-sized leaves than plants with large or small leaves. The effect of reducing PM2.5 was higher in linear leaves than round or lobed leaves. Plants with high total leaf area did not have advantage in reducing PM because the leaves were relatively small and there were many overlapping parts between leaves. In the correlation between leaf characteristics and PM 2.5 reductions, all leaf area and leaf thickness showed a negative and leaf size showed a positive correlation with PM reduction. Conclusion: The PM reduction effect of plants with medium-sized leaves and long linear leaves was relatively high. Moreover, plants with a large total leaf area without overlapping leaves will have advantaged in reducing PM. Plants are effective in reducing PM, and leaf characteristics are an important factor that affects PM reduction.

Fatty Acid and Carotenoid Production by Sporobolomyces ruberrimus when Using Technical Glycerol and Ammonium Sulfate

  • Razavi, Seyed Hadi;Mousavi, Seyed Mohammad;Yeganeh, Hassan Mehrabani;Marc, Ivan
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권10호
    • /
    • pp.1591-1597
    • /
    • 2007
  • The production of carotenoids, lipid content, and fatty acid composition were all studied in a strain of Sporobolomyces ruberrimus when using different concentrations of technical glycerol as the carbon source and ammonium sulfate as the nitrogen source. The total lipids represented an average of 13% of the dry weight, and the maximum lipids were obtained when using 65.5 g/l technical glycerol (133.63 mg/g). The optimal conditions for fatty acid production were at $27^{\circ}C$ using 20 g of ammonium sulfate and a pH range from 6 to 7, which produced a fatty acid yield of $32.5{\pm}1\;mg/g$, including $1.27{\pm}0.15\;mg$ of linolenic acid (LNA), $7.50{\pm}0.45\;mg$ of linoleic acid (LLA), $5.50{\pm}0.35\;mg$ of palmitic acid (PA), $0.60{\pm}0.03\;mg$ of palmitoleic acid (PAL), $1.28{\pm}0.11\;mg$ of stearic acid (SA), $9.09{\pm}0.22\;mg$ of oleic acid, $2.50{\pm}0.10\;mg$ of erucic acid (EA), and $4.25{\pm}0.20\;mg$ of lignoceric acid (LCA), where the palmitic, oleic, and linoleic acids combined formed about 37% of the total fatty acids. The concentration of total carotenoids was 2.80 mg/g when using 20 g of ammonium sulfate, and consisted of torularhodin (2.70 mg/g) and $\beta$-carotene (0.10 mg/g), at $23^{\circ}C$ and pH 6. However, the highest amount with the maximum specific growth rate was obtained (${\mu}_{max}=0.096\;h^{-1}$) with an ammonium sulfate concentration of 30 g/l.

건강성인의 혈구 참고치 산정 (Hematological Reference Values in the Healthy Adults)

  • 김영진;현명수;이현우
    • Journal of Yeungnam Medical Science
    • /
    • 제8권1호
    • /
    • pp.154-165
    • /
    • 1991
  • 1) 건강한 성인 2823명을 대상으로 자동혈구 계산기인 Coulter Counter Model S plus II를 이용하여 본원의 참고치를 설정하였다. 산출된 참고치는 기기의 설명서에 제시되어 임상 의사들이 사용하고 있는 참고치와 차이가 있었다. 2) 국내의 보고들과 비교해 볼 때 본원의 참고치와 대체로 비등하였고 기기의 설명서에 제시된 참고치와는 차이가 있으므로 본원의 참고치률 설정하여 사용하여야 하겠다. 3) 결과는 다음과 같다. (1) 백혈구 수는 남자 $6.800{\pm}2.680(2SD)/{\mu}l$, 여자 $5.950{\pm}2.380(2SD)/{\mu}l$ 이었다. (2) 적혈구 수는 남자 $428{\pm}60(2SD){\times}10^4/{\mu}l$, 여자 $415{\pm}56(2SD){\times}10^4/{\mu}l$ 이었다. (3) 혈색소량은 남자 $15.4{\pm}1.8(2SD)g/dL$, 여자 $13.0{\pm}1.6(2SD)g/dL$ 이었다. (4) 적혈구 용적은 남자 $45.3{\pm}5.0(2SD)%$, 여자 $38.2{\pm}4.6(2SD)%$ 이었다. (5) 평균 적혈구 용적은 남자 $93.8{\pm}5.8(2SD)fL$, 여자 $92.2{\pm}7.4(2SD)fL$ 이었다. (6) 평균 적혈구 혈색소량은 남자 $31.8{\pm}2.2(2SD)pg$, 여자 $31.4;{\pm}2.8(2SD)pg$ 이었다. (7) 평균 적혈구 혈색소농도는 남자 $34.0{\pm}1.2(2SD)%$, 여자 $33.9{\pm}1.2(2SD)%$ 이었다. (8) 적혈구 분포 폭은 남자 $12.7{\pm}1.0(2SD)%$, 여자 $12.6{\pm}1.4(2SD)%$ 이었다. (9) 혈소판 수는 남자 $242.9{\pm}87.8(2SD){\times}10^4/{\mu}l$, 여자 $242.2{\pm}89.0(2SD){\times}10^4/{\mu}l$ 이었다. (10) 혈소판 용적은 남자 $0.201{\pm}0.076(2SD)%$, 여자 $0.204{\pm}0.076(2SD)%$ 이었다. (11) 평균 혈소판 용적은 남자 $8.20{\pm}1.70(2SD)fL$, 여자 $8.36{\pm}1.82(2SD)fL$ 이었다. (12) 혈소판 분포 폭은 남자 $16.1{\pm}0.8(2SD)%$, 여자 $16.0{\pm}0.8(2SD)%$ 이었다.

  • PDF