• Title/Summary/Keyword: $O_2$ Sensor

Search Result 1,272, Processing Time 0.03 seconds

Analysis of the Characteristics of Flue Gas in Infrared Mobile Heaters for Gas Room Heating (가스난방용 적외선 히터의 연소배기가스 특성해석)

  • Kim Young-Gyu;Kwon Jeong-Rock;Kim Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.66-73
    • /
    • 1998
  • This paper deals with the combustion characteristics of flue gas in infared mobile heaters. The experimental work has been performed to obtain the concentration levels and combustion characteristics of flue gas with varying chamber size and room temperature. The experimental results showed that oxygen depletion sensor device was operated at the oxygen concentration level of $18.3\%$ for all the chamber size. The combustion characteristics of oxygen and carbon dioxide show a linearity After 10 minutes the combustion property of carbon monoxide occurs at random without a level of oxygen and carbon dioxide in closed space of the heater. In these results, it is very important to prevent incomplete combustion through a sufficient ventilation, and accident prevention with a reduction of the oxygen and diffusion of toxic carbon monoxide.

  • PDF

Magnetoresistive Properties of Array IrMn Spin Valves Devices (어레이 IrMn 스핀밸브 소자의 자기저항특성 연구)

  • Ahn, M.C.;Choi, S.D.;Joo, H.W.;Kim, G.W.;Hwang, D.G.;Rhee, J.R.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.156-161
    • /
    • 2007
  • To develop array magnetic sensors, specular-type giant magnetoresistive- spin valve (GMR-SV) film of Glass/Ta(5)MiFe(7)/IrMn(10)NiFe(5)/$O_2$/CoFe(5)/Cu(2.6)/CoFe(5)/$O_2$/NiFe(7)/Ta(5)(nm) was deposited by using a high-vacuum sputtering system. One of 15 way sensors in the area of $8{\times}8mm^2$ was Patterned a size of $20{\times}80{\mu}m^2$ in multilayer sample by Photo-lithography. All of 15 sensors with Cu electrodes were measured a uniform magnetic properties by 2-probe method. The highest magnetic sensitivity of MR and output voltage measured nearby an external magnetic field of 5 Oe were MS = 0.5%/Oe and ${\triangle}$V= 3.0 mV, respectively. An easy-axis of top-free layers of $CoFe/O_2/NiFe$ with shape anisotropy was perpendicular to one of bottom-pinned layers $IrMn/NiFe/O_2/CoFe$. When the sensing current increased from 1 mA to 10 mA, the output working voltage uniformly increased and the magnetic sensitivity was almost stable to use the nano-magnetic devices with good sensitive properties.

Fabrication of Micro-Flow Sensors with High-response Time (고속응답 마이크로 유량센서의 제작)

  • Chung, Gwiy-Sang;Hong, Seok-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.17-20
    • /
    • 2000
  • This paper describes on the fabrication and characteristics of hot-film type micro-flowsensors integrated with Pt-RTD's and micro-heaters on the Si substrate, in which MgO thin-films were used as medium layer in order to improve adhesion of Pt thin-films to $SiO_2$ layer, The MgO layer improved adhesion of Pt thin-films to $SiO_2$ layer without any chemical reactions to Pt thin-films under high annealing temperatures. In investigating output characteristics of the fabricated micro-flowsensors, the output voltages increased as gas flow rate and its conductivity increased due to increase of heat-loss from sensor to external. Output voltage was 82 mV at $N_2$ flow rate of 2000 seem/min, heating power of 1.2W.

  • PDF

Simultaneous Detection of Tartrazine-Sunset Yellow in Food Samples Using Bioxide/Carbon Paste Microcomposite with Lanthanum and Titanium

  • Nagles, Edgar;Ceroni, Mario;Hurtado, John
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.421-429
    • /
    • 2020
  • This report describes the simultaneous detection of the two dyes most commonly used in food, tartrazine (TZ) and sunset yellow (SY), based on a microcomposite of carbon paste decorated with La2O3 and TiO2. Anodic currents for SY-TZ were observed at 0.89-1.21 V by cyclic voltammetry (CV) separated with a ΔV of 0.32 V. The increased anodic peak currents compared to that of the unmodified carbon paste electrode were almost 50 and 41% for SY-TZ, respectively. The detection limits with the optimal amount of La2O3-TiO2 were 0.02 and 0.03 µmol/L, respectively. The relative standard deviation (RSD) based on fifty measurements was less than 3%. The versatility and novelty of the sensor were tested with food samples containing these substances and other substances.

Characteristics of AlN thin films for SAW filters based on substrates (기판의 종류에 따른 SAW 필터용 AlN 박막의 특성)

  • Ko, Bong-Chul;Nam, Chang-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.240-245
    • /
    • 2007
  • AlN thin film for SAW filter application was deposited on (100) silicon, sapphire, $Si_{3}N_{4}$/Si, and $Al_{2}O_{3}$/Si substrates by reactive magnetron sputtering method, respectively. The structural characteristics were dependent on the structure of substrates. Scanning Electron Microscope (SEM), X-ray Diffraction (XRD) and Atomic Force Microscope (AFM) have been used to analyze structural properties and preferred orientation of AlN thin films. Preferred orientation and SAW characteristic of AlN were improved by insertion of $Al_{2}O_{3}$ buffer layer. Insertion loss of SAW devices using AlN/Si and AlN/$Al_{2}O_{3}$/Si were about 33.27 dB and 30.20 dB, respectively.

A study on improving sensitivity to CO2 gases of Na solid electrolyte sensors adding CaO (CaO를 첨가한 Na고체전해질 센서의 CO2가스 감도향상에 관한 연구)

  • Kwak, Jong-Sig;Seo, Moo-Gyo;Choi, Soon-Don;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.218-223
    • /
    • 2002
  • NASICON sensors that the NASICON electrolytes with various CaO amounts were sintered at low temperature($900^{\circ}C$), were fabricated to improve $CO_2$ sensitivity and stability in sensing behaviors. The manufactured device was shown good sensing characteristics and stability of output electromotive force at $250^{\circ}C$, comparatively low operating temperature.

Raman Spectroscopy of the Solid Solution Limit in $Li_{1-X}Al_{2X}Ta_{1-X}O_3$ System (Raman 분광법을 이용한 $Li_{1-X}Al_{2X}Ta_{1-X}O_3$ 고용한계 분석)

  • Kim, Chong-Don;Hong, Kug-Sun;Joo, Gi-Tae
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.115-120
    • /
    • 1992
  • The upper limit of solid solution of $Al_2O_3$ in $LiTaO_3$ was investigated using X-ray diffraction and Raman spectroscopy. By substituting cations in $LiTaO_3$ with $Al^{3+}$, the melting temperature was lowed and the ferroelectric properties can be improved. It is easier at lower temperature to fabricate the single crystal used for SAW filters and IR sensors. From the measured lattice constants and Raman band broadening, the solubility limit was X=0.25mol in $Li_{1-X}Al_{2X}Ta{1-X}O_3$, above which $Al_2O_3$ was obsered as a second phase. The Raman band of sintered $LiTaO_3$ was compared with that of the single crystal to see the effect of grain size on the band broadening.

  • PDF

Fabrication and Characteristics of Surface-Acoustic-Wave Sensors for Detecting $NO_2$ GaS ($NO_2$ 가스 감지를 위한 표면탄성파 센서의 제작 및 특성)

  • Choi, D.H.
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.108-114
    • /
    • 1999
  • Surface acoustic wave (SAW) device is very attractive for gas sensor applications because of their small size, low cost, high sensitivity, and good reliability. A dual delay line surface acoustic wave $NO_2$ gas sensors have been designed and fabricated on the $LiTaO_3$ piezoelectric single crystal substrate. The capacitance of the fabricated IDTs was 326.34pF at the frequency of 79.3MHz. The maximum reflection loss of the impedence-matched IDTs was -16.74dB at the frequency of 79.3MHz. The SAW oscillator was constructed and the stable oscillation was obtained by controlling the gain of rf amplifier properly. The oscillation frequency shift of the SAW oscillator to the $NO_2$ gas was 28Hz/ppm.

  • PDF

The Structural and Optical Properties of ZnO : $Al_{2}O_{3}$ Compound by Reaction Sintering (Reaction Sintering에 의한 ZnO : $Al_{2}O_{3}$ 합성물의 구조 및 광학적 특성)

  • Kang, Byeong-Mo;Park, Gye-Choon;Yoo, Yong-Tek
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.218-224
    • /
    • 1998
  • 2nO and $Al_{2}O_{3}$ powder were weighed in 1 : 1 mole ratio and ball-milled in ethanol for 3 h. Dried mixture were pressed and then sintered at $900^{\circ}C{\sim}1200^{\circ}C$ for 3 h in vacuum($3{\times}10^{-5}$ Torr). According to XRD, remnant ZnO and $Al_{2}O_{3}$ not converted to $ZnAl_{2}O_{4}$ were observed up to $1100^{\circ}C$, which were completely changed to$ZnAl_{2}O_{4}$ ternary compound at $1200^{\circ}C$. Optical bandgap is calculated at 4.75 eV. With increasing sintering temperature, PL spectrums shifted to shorter wavelengths and are appeared 430nm at $1200^{\circ}C$.

  • PDF

Influence of Negative-Pressure Wound Therapy on Tissue Oxygenation of the Foot

  • Shon, Yoo-Seok;Lee, Ye-Na;Jeong, Seong-Ho;Dhong, Eun-Sang;Han, Seung-Kyu
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.668-672
    • /
    • 2014
  • Background Negative-pressure wound therapy (NPWT) is believed to accelerate wound healing by altering wound microvascular blood flow. Although many studies using laser Doppler have found that NPWT increases perfusion, recent work using other modalities has demonstrated that perfusion is reduced. The purpose of this study was to investigate the influence of NPWT on tissue oxygenation of the foot, which is the most sensitive region of the body to ischemia. Methods Transcutaneous partial pressure of oxygen ($TcpO_2$) was used to determine perfusion beneath NPWT dressings of 10 healthy feet. The sensor was placed on the tarso-metatarsal area of the foot and the NPWT dressing was placed above the sensor. $TcpO_2$ was measured until it reached a steady plateau state. The readings obtained at the suction-on period were compared with the initial baseline (pre-suction) readings. Results $TcpO_2$ decreased significantly immediately after applying NPWT, but gradually increased over time until reaching a steady plateau state. The decrease in $TcpO_2$ from baseline to the steady state was 2.9 to 13.9 mm Hg (mean, $9.3{\pm}3.6$ mm Hg; $13.5{\pm}5.8%$; P<0.01). All feet reached a plateau within 20 to 65 minutes after suction was applied. Conclusions NPWT significantly decrease tissue oxygenation of the foot by 2.9 to 13.9 mm Hg. NPWT should be used with caution on feet that do not have adequate tissue oxygenation for wound healing.