• 제목/요약/키워드: $NO_2$ reduction

검색결과 3,627건 처리시간 0.036초

CO2/NOx 초저배출형 HCCI 엔진 연소기술과 신촉매제어기술 (HCCI Combustion Engines with Ultra Low CO2 and NOx Emissions and New Catalytic Emission Control Technology)

  • 김문현
    • 한국환경과학회지
    • /
    • 제17권12호
    • /
    • pp.1413-1419
    • /
    • 2008
  • The Kyoto Protocol, that had been in force from February 16, 2005, requires significant reduction in $CO_2$ emissions for all anthropogenic sources containing transportation, industrial, commercial, and residential fields, etc, and automotive emission standards for air pollutants such as particulate matter (PM) and nitrogen oxides $(NO_x)$ become more and more tight for improving ambient air quality. This paper has briefly reviewed homogeneous charge compression ignition (HCCI) combustion technology offering dramatic reduction in $CO_2,\;NO_x$ and PM emissions, compared to conventional gasoline and diesel engine vehicles, in an effort of automotive industries and their related academic activities to comply with future fuel economy legislation, e.g., $CO_2$ emission standards and corporate average fuel economy (CAFE) in the respective European Union (EU) and United States of America (USA), and to meet very stringent future automotive emission standards, e.g., Tier 2 program in USA and EURO V in EU. In addition, major challenges to the widespread use of HCCI engines in road applications are discussed in aspects of new catalytic emissions controls to remove high CO and unburned hydrocarbons from such engine-equipped vehicles.

X선 진단시 피폭선량을 반으로 줄이기 위한 Cu Filter의 두께 (The thickness of Cu Filter to reduce 1/2 of the patient dose)

  • 김정민;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권1호
    • /
    • pp.17-22
    • /
    • 2001
  • Medical X-ray examination are increased double for the last $6{\sim}8$ years. Therefore a patient exposure dose should be decrease half every 7 years. We made an experiment on copper filter thickness to decrease a patient exposure dose up to half and compared to the Image quality by MTF. The results as follow 1. A thin region like extremities needs a thicker Cu filter as compared a thick region. 2. 1/2 reduction filter must be thicker when kVp Increase. 3. Exposure factor should be increas when using 1/2 reduction filter ; extremity is 4.0 times, chest 2.9 times, skull 1.62 times, and abdomen 1.58 times 4. The MTF of using 1/2 reduction filter is lower than without filter. But no difference of visual image. 5. 1/2 reduction filter compared with double speed screen showed almost same image quality.

  • PDF

전과정을 고려한 도로-철도 Modal Shift $CO_2$ 저감효과 분석 ($CO_2$ Reduction Effect Analysis of Modal Shift from Road to Rail using Life Cycle Thinking)

  • 김초영;이철규;최요한;이건모
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2921-2927
    • /
    • 2011
  • Modal Shift from road to rail has been adapted in several countries as one of effective ways of reducing $CO_2$ emissions caused by transport. Generally, effect analysis of $CO_2$ reduction toward modal shift is calculated mainly from use stage and less consideration from other stages of life cycle, even though, in some case of modal shift needs that new line construction or new vehicle manufacturing. In this study, modal shift effect analysis is performed with considering construction, manufacturing vehicle and use stage. As a result we can get total $CO_2$ reduction effect using life cycle thinking and check the necessity of including other life cycle stage not only considering use stage. In conclusion, there is no $CO_2$ reduction effect if the reduction amount of $CO_2$ in use stage is not bigger than allocated annual amount of $CO_2$ in construction and manufacturing vehicle stage. According to this fact, analysing $CO_2$ reduction effect of Modal Shift should be considered not only the use stage.

  • PDF

Catalytic Reduction of ortho- and meta-Nitroaniline by Nickel Oxide Nanoparticles

  • Jeon, Sugyeong;Ko, Jeong Won;Ko, Weon Bae
    • Elastomers and Composites
    • /
    • 제55권3호
    • /
    • pp.191-198
    • /
    • 2020
  • Nickel oxide (NiO) nanoparticles were synthesized by a reaction of nickel nitrate hexahydrate (Ni(NO3)2·6H2O) and sodium hydroxide (NaOH). The synthesized NiO nanoparticles were examined with X-ray diffraction, scanning electron microscopy, Raman spectroscopy, and ultraviolet-visible (UV-vis) spectroscopy. The NiO nanoparticles were used as the catalyst for the reduction of o- and m-nitroaniline to phenylenediamine. The reduction rate of m-nitroaniline was faster than that of o-nitroaniline. The reduction rate for both o- and m-nitroaniline increased as the reaction temperature increased. The rate of reduction for nitroaniline followed a pseudo first-order reaction rate law.

Applications of response dimension reduction in large p-small n problems

  • Minjee Kim;Jae Keun Yoo
    • Communications for Statistical Applications and Methods
    • /
    • 제31권2호
    • /
    • pp.191-202
    • /
    • 2024
  • The goal of this paper is to show how multivariate regression analysis with high-dimensional responses is facilitated by the response dimension reduction. Multivariate regression, characterized by multi-dimensional response variables, is increasingly prevalent across diverse fields such as repeated measures, longitudinal studies, and functional data analysis. One of the key challenges in analyzing such data is managing the response dimensions, which can complicate the analysis due to an exponential increase in the number of parameters. Although response dimension reduction methods are developed, there is no practically useful illustration for various types of data such as so-called large p-small n data. This paper aims to fill this gap by showcasing how response dimension reduction can enhance the analysis of high-dimensional response data, thereby providing significant assistance to statistical practitioners and contributing to advancements in multiple scientific domains.

Optical and Dielectric Properties of Reduced SrTiO3 Single Crystals

  • Kang, Bong-Hoon
    • 한국세라믹학회지
    • /
    • 제48권4호
    • /
    • pp.278-281
    • /
    • 2011
  • The optical band gap energy for $SrTiO_3$ by reduction at high temperature was 3.15 eV. The reflectivity of reduced $SrTiO_3$ single crystals showed little variation, however, the reflectivity by the reduction condition had no effect. For the phonon mode at about 790 $cm^{-1}$, a blue-shift took place upon $N_2$ reduction and the decreased. However, a red-shift took place upon a $H_2-N_2$ reduction and the increased at the same phonon mode. With decreasing temperature the dielectric constant decreased rapidly. The thermal activation energies were 0.92-1.02 eV.

곽향(Agastache rugosa)을 포함한 21종의 한약재가 대식세포주 RAW 264.7 세포의 nitric oxide(NO) 생산 조절에 미치는 효과 (Modulatory Effects of 21 kinds of Medicinal Herbs Including Herba Pogostemi (Agastache rugosa) on Nitric Oxide Production in Macrophage Cell line RAW 264.7 cells)

  • 김승현;강미영;남석현
    • Applied Biological Chemistry
    • /
    • 제48권4호
    • /
    • pp.411-417
    • /
    • 2005
  • 마우스 대식세포주인 RAW264.7 세포에서 곽향(Agastache rugosa)을 포함한 21종의 한약재에서 제조한 열수추출물의 NO생산에 대한 조절효과를 조사하였다. 모든 한약재 추출물은 LPS자극으로 생산된 NO에 대하여 뚜렷한 소거활성을 보이지 않았으나, LPS 무처리 조건에서 곽향이 RAW264.7 세포의 NO생산을 강력하게 유도하였다. $200{\mu}M$의 NOS2의 저해제인 $N^G-monomethyl-L-arginine(N^GMMA$)의 처리에 의하여 곽향이 유도하는 NO 생산은 유의적으로 감소되었다. 또한 $NF-{\kappa}B$ 저해제인 pyrrolidine dithiocarbamate(PDTC)의 처리로 NO 생산이 $100{\mu}M$에서 약 79%까지 감소하였다. 이상의 실험 결과는 곽향 열수추출물이 RAW264.7 세포의 NOS2 발현의 이차적인 세포 내 신호를 발생시킬 수 있으며, NO는 L-arginine 의존적 경로에 의하여 생성된다는 사실을 시사하였다.

세라믹 시트 필터에 부착된 V2O5-WO3/TiO2 촉매의 NO 환원 성능 (NO Reduction Performance of V2O5-WO3/TiO2 Catalyst Supported on a Ceramic Sheet Filter)

  • 최주홍
    • 청정기술
    • /
    • 제24권1호
    • /
    • pp.27-34
    • /
    • 2018
  • 분진과 질소 산화물을 동시에 처리할 수 있는 이원적 기능을 가진 촉매 필터는 산업체 적용에 많은 장점을 갖고 있다. 통기성이 높은 시트 형 세라믹 필터를 촉매 필터 소재로 활용하면 배기가스 처리 공정의 타당성을 더욱 높일 것이다. 그러나 시트 필터는 두께가 얇아서 촉매 지지층에 촉매를 부착할 수 있는 공간이 부족하므로 효과적인 촉매필터를 제조하기가 쉽지 않다. 본 연구에서는 국산 시트 필터를 사용하여 촉매 필터를 제조하고 실험실 장치에서 제조된 촉매 필터의 NO 환원 성능이 평가되었다. 현재 시판되고 있는 시트 필터로 촉매 필터를 제조할 경우 여과속도 $2m\;s^{-1}$에서 700 ppm NO 농도에 대한 NO 전환율이 92% 이하로써 촉매 필터 재료로써 좋은 특성을 나타내지 못했다. 이와 같이 저조한 특성을 보이는 이유는 시트 필터의 촉매 지지층의 기공이 균일하지 못하여 필요 이상의 큰 기공이 존재하기 대문으로 해석되었다. 필터에 존재하는 큰 기공의 사이즈를 줄이기 위하여 필터를 제조하는 원재료에 작은 입자를 혼합하여 시트 필터의 기공을 줄이는 효과를 통하여 NO 전환율 96% 이상을 달성하였다. 또한 촉매 지지체로써 큰 입자의 $TiO_2$를 혼합하여 촉매층의 기공을 팽창시켜서 개선된 촉매 필터는 상용 요구에 충족되는 98% 이상의 NO 전환율을 보였다. 위 두 경우 모두 촉매층 내에 존재할 수 있는 큰 기공을 효과적으로 메워서 적절한 촉매층이 형성되면 촉매 필터의 성능이 향상되는 결과를 보인 것이다. 따라서 이와 같이 통기도가 우수한 장점을 가진 시트 필터가 촉매 필터의 소재로 잘 활용될 수 있음을 보였다.

CNG 버스용 NGOC의 CH4 저감 성능 향상을 위한 연구 (Research on Improvement of CH4 Reduction Performance of NGOC for CNG Bus)

  • 서충길
    • 한국산학기술학회논문지
    • /
    • 제18권5호
    • /
    • pp.708-715
    • /
    • 2017
  • 최근에 엄격한 배기가스규제를 충족시키기 위해 자동차와 선박용 후처리장치의 비중이 점차로 증가하고 있다. 이 연구의 목적은 CNG 버스에서 배출되는 유독성 가스를 저감하는 NGOC의 $CH_4$ 저감능력 향상을 연구하는 것이다. 13종의 천연가스산화촉매(NGOC)를 제조하였고, 지지체(support)의 종류, 귀금속의 담지량 영향 및 계면활성제와 열화에 따른 유해가스 전환 성능을 파악하였다. 3번 $NGOC(1Pt-1Pd-3MgO-3CeO_2/(46TiO_2+23Al_2O_3+23Zeolite)$에 담지된 지지체 Zeolite는 음이온 알칼리금속/토금속 성분으로 CO와 NO와의 산화반응성 및 귀금속 분산도를 향상시켜 $CH_4$ 저감능력을 향상시켰다. Pd는 $CH_4$에 대한 선택도가 큰 귀금속이며, 담지량이 증가할수록 반응사이트가 더 많아져 $CH_4$ 저감 능력이 향상되었다. Pt 11wt%가 담지된 9번 NGOC(11Pt-6Pd-3MgO/(40Zeolite+$40Al_2O_3$)의 경우, 과하게 담지된 Pt 담지량은 오히려 CO와 NO 전환율이 감소하였으며, 이는 Pt 분산도 저하 및 CO와 NO 산화반응에 선택적인 Zeolite 함량이 감소하였기 때문이다. 계면활성제가 첨가된 11번 NGOC(1Pt-1Pd-3MgO-$3CeO_2$/(Z 20+Al80)(pH=8.5)가 촉매 입자의 분산이 잘되어있고, 응집(agglomeration)되지 않아 $CH_4$ 저감 능력이 5-15% 향상되었다. Mild하게 48h 열적 열화된 13번 NGOC(2Pt-2Pd-3Cr-3MgO/$90Al_2O_3$)(48h aging)는 12번 NGOC(Fresh)에 비해 $CH_4$ 저감 능력이 약 10% 이하로 상승하였다.

중형 운행 경유차용 Urea-SCR 시스템의 아랫첨자 $NO_X$ 저감성능에 미치는 영향인자 (Influential Factors for NO_X Reduction Performance of Urea-SCR System for an In-use Medium Duty Diesel Engine)

  • 김홍석;정용일;송명호;이성욱;박현대;황재원
    • 한국자동차공학회논문집
    • /
    • 제17권1호
    • /
    • pp.154-161
    • /
    • 2009
  • This study is a part of project of urea-SCR system development for an in-use medium duty diesel engine. This study shows the effect of ammonia oxidation catalyst and SCR volume on $NO_X$ reduction performance. When AOC(Ammonia Oxidation Catalyst) is not used, the urea injection should be controlled accurately to prevent $NH_3$ slip. However, it is found that the accurate $NH_3$ slip control is not easy without AOC in real engine operating conditions, because $NH_3$ and $NO_X$ reaction characteristics change with many factors such as exhaust gas temperature and $NH_3$ absorbance on SCR. SCR volume is also one of important design parameters. This study shows that $NO_X$ reduction efficiency increases with increase of SCR volume especially at high space velocity and low exhaust gas temperature conditions. Additionally, this paper shows the emissions of EURO-2 medium duty diesel engine can be improved to the level of EURO-5 with a DPF and urea-SCR system.