• 제목/요약/키워드: $NO_2$ gas

검색결과 2,394건 처리시간 0.034초

$BaTiO_3$-슬러지 Packed-bed형 반응기에서 $NO_x$제거에 미치는 슬러지의 영향 (Effect of Sludge Pellets on $NO_x$ REmoval in $BaTiO_3$-sludge Packed-bed Reactor)

  • 박재윤;송원섭;고희석;박상현
    • 한국전기전자재료학회논문지
    • /
    • 제14권10호
    • /
    • pp.861-867
    • /
    • 2001
  • In this paper, in order to investigate the catalytic effect of the sludge exhausted from waterworks on NO$_{x}$ removal, we measure NO removal characteristics with and without sludge pellets in BaTiO$_3$-sludge packed-bed reactor of plate-plate geometry. NO initial concentration is 50 ppm balanced with air and a gas flow rate is 5ι/min. Gas temperature is changed from 25 to 10$0^{\circ}C$ to investigate the role of sludge pellet on removing active oxygen species and NO$_2$. BaTiO$_3$pellets is filled for coronal discharge at upstream of reactor and sludge pellets is filled for catalytic effect at downstream of reactor. The volume percent of sludge pellets to BaTiO$_3$pellets is changed from 0% to 100% and AC voltage is supplied to the reactor for discharging simulated gases. In the results, when sludge pellets is put at the downstream of plasma reactor, NO removal rate is slightly increased. However, NO$_2$and $O_3$ as by-products during NO removal is significantly decreased from 51ppm without sludge pellets to 5 ppm with sludge pellets and from 50 ppm without sludge pellets to 0.004ppm with sludge pellets, respectively. Therefore, NO$_{x}$(NO+NO$_2$) removal rate is increased up to 93%. It is thought that sludge pellet maybe react with active oxygen species and NO$_2$ generated by corona discharge in surface of BaTiO$_3$pellets, the then NO$_2$O$_3$as by-products are considerably decreased. When we increase gas temperature from room temperature to 10$0^{\circ}C$, NO removal rate is decreased, while NO$_2$ concentration is independent on gas temperature. These result suggest that the removal mechanism of active oxygen species and NO$_2$in sludge pellet is not absorption, but chemical reaction. Therefore we expect that sludge pellets exhausted for waterworks could be used as catalyst for NO$_{x}$ removal with high removal rate and low by-product.oduct.

  • PDF

$TiB_2$ 광촉매를 이용한 $NO_x$ 제거 (Removal of $NO_x$ by using of $TiB_2$ Photocatalysis)

  • 이용환;최인호
    • 환경위생공학
    • /
    • 제24권4호
    • /
    • pp.112-115
    • /
    • 2009
  • This research was performed to purify water quality through removing T-N, and T-P and to estimating rate of $NO_x$ by the response of photocatalyst using ceramics. The ceramics was a mixtures of Titanium Diboride($TiB_2$) which is used to develop armored cars with excellent protective power and lightness, Olivine, and Hwangto with water and was furnaced for an hour at $1160^{\circ}C$. Hwangto and Olivine used in the study are produced at Haenam-gun, Jeonnam, and Andong-city, Gyeongsangbuk-do, respectively. The ground Hwangto and Olivine were seived through PR $100{\times}200$, and $TiB_2$ was a product of SIGMA ALDRICH. The experiment was performed under the sunlight, Mass flow controller was used for constant flow to pass through the pyrex reactor which was fully charged with furnaced ceramics. The concentration of $NO_2$ gas passed through the pyrex reactor was measured by Multi Gas Monitor. The reaction took for 60 minutes, The material was exposed to sunlight for 40 minutes. The sunlight was interrupted before and after the exposure for 10 minutes. The result showed that the concentration of $NO_2$ gas of the ceramics with $TiB_2$ and without $TiB_2$ became reduced and then maintained the same concentration under the sunlight, and became increased when the sunlight is interrupted. The $NO_2$ removing efficiency of the ceramics mixed with $TiB_2$ was 14~43% higher than that of the ceramics without $TiB_2$ under the sunlight. The study showed that the removing rate of $NO_2$ was 80% when the mixture rate of Hwangto, Olivine, and $TiB_2$ was 68%, 30% and 2%.

침대평판전극에서의 NOx 제거특성 (Reduction characteristics of NOx on point-plane electrode)

  • 김건호;김종달;김정달;김치원;이덕출;고희석;박재윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1317-1319
    • /
    • 1995
  • In this paper, we studied reduction characteristics of NOx gas produced from diesel engine combustion using by point-plane electrode. Here, input voltage forms were types of three [DC, AC, DC Positive pulse] and NOx gas of 1700ppm was composed of NO 1665ppm, $NO_2$ 35ppm on balance of $N_2$. We investigated NOx reduction characteristics as various of parameters, are gas flow rate, input voltage form and, humidity. From the results of study, reduction characteristics of NOx exhibited good when gas flow rate was small, input voltage was DC and much humidity were contained to NOx gas.

  • PDF

박막형 $WO_{3}$계 가스센서의 NOx 감도 특성 (NOx Sensing Characteristics of the $WO_{3}$-Based Thin-Film Gas Sensors)

  • 유광수
    • 센서학회지
    • /
    • 제5권5호
    • /
    • pp.39-46
    • /
    • 1996
  • $WO_{3}$에 미량의 Pd 또는 Pt가 첨가된 박막을 이용한 NOx 센서를 제조하였다. $WO_{3}$계 박막은 고진공, 저항가연식 evaporator를 이용하여 분위기온도에서 증착한 다음 $500^{\circ}C$에서 열처리하였다. 5 ppm의 $NO_{2}$가스에 대하여 $200^{\circ}C$에서 측정한 가스감도($R_{gas}/R_{air}$)는 0.5 wt.% $Pt-WO_{3}$ 센서에서 50으로서 최대값을 가졌다.

  • PDF

Environmental awareness and economical profits of replacing gas turbines in gas compressor stations: A case study of Polkalleh station in Iran

  • Sadrnejad, Amin;Noorollahi, Younes;Sadrnejad, Tohid
    • Environmental Engineering Research
    • /
    • 제21권2호
    • /
    • pp.132-139
    • /
    • 2016
  • In early 90s the worldwide awareness about the energy crisis and global warming had been increased and emission reduction (by improving energy efficiency), as well as increasing the capacity of clean and renewable energies, showed themselves as the most important steps towards the sustainable development approach. However, investigations on Iran's environmental situation show huge decline in recent decades and apparently there is no sense of urgency about these issues through the vision of Iranian politicians. In this article the idea of replacing the old gas turbines of Polkalleh natural gas compressor station - as one of the main compressor stations of Iran - with newer and more efficient gas turbines is evaluated, emphatically for reducing greenhouse gases emissions and their environmental costs and decreasing natural gas consumption as well. Clearly such idea is costly, but analyzing its economic impacts, huge declines in annual costs and greenhouse gases emissions can be seen as well. So an investment about $95 million can decrease 40% of Polkalleh compressor station annual costs, 25% of natural consumption and 30% of $CO_2$ and $NO_x$ emissions. Besides the simple payback period of this investment is about 2.5 years from the cut-expenses of annual costs.

Optical Properties of Multi-layer TiNO/AlCrNO/Al Cermet Films Using DC Magnetron Sputtering

  • Han, Sang-Uk;Park, Soo-Young;Kim, Hyun-Hoo;Jang, Gun-Eik;Lee, Yong-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권5호
    • /
    • pp.280-284
    • /
    • 2015
  • Among many the oxynitrides, TiNO and AlCrNO, have diverse applications in different technological fields. We prepared TiNO/AlCrNO/Al thin films on aluminum substrates using the method of dc reactive magnetron sputtering. The reactive gas flow, gas mixture, and target potential were applied as the sputtering conditions during the deposition in order to control the chemical composition. The multi-layer films have been prepared in an Ar and O2+N2 gas mixture rate. The surface properties were estimated by performing scanning electron microscopy (SEM). At a wavelength range of 0.3~2.5 μm, the exact composition and optical properties of thin films were measured by Auger electron spectroscopy (AES) and Ultraviolet-visible-near infrared (UV-Vis-NIR) spectrophotometry. The optimal absorptance of multi-layer films was exhibited above 95.5% in the visible region of the electromagnetic spectrum, and the reflectance was achieved below 1.89%.

도시가스와 혼합가스($H_2$, CO) 적용 시 점화시기 및 공연비에 따른 발전효율 및 질소산화물 배출량 비교 (Comparison of effects of spark timing and fuel ratio on engine efficiency and $NO_x$ emission for fuel of city gas and syngas($H_2$ and CO))

  • 정철영;이경택;송순호;전광민;남상익
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.817-820
    • /
    • 2009
  • Research on usage of syngas produced by waste gasification is on going all around the world. Syngas which consists of $H_2$, CO, $CO_2$, $N_2$, has different combustion characteristics from current city gas; due to distinct flame propagation speed of the fuel, syngas has different spark timing and air fuel ratio at maximum generating efficiency. This is why finding both the optimum point of spark timing and air fuel ratio is so important in order to improve thermo efficiency and secure stable running of gas generated by relatively low heating value syngas. Moreover, since emission of $NO_x$ is strictly regulated, it is important to operate lean burn condition that reduces NOx emission.

  • PDF

Fabrication, Structure and Gas Sensing Properties of Pt-functionalized ZnS Nanowires

  • Kim, Soohyun;Park, Sunghoon;Jung, Jihwan;Lee, Chongmu
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.315.2-315.2
    • /
    • 2014
  • Pt-functionalized ZnS nanowires were synthesized on Au-deposited c-plane sapphire substrates by thermal evaporation of ZnS powders followed by wet Pt coating and annealing. The $NO_2$ gas sensing properties of multiple-networked Pt-functionalized ZnS nanowire sensors were examined. Scanning electron microscopy showed the nanowires with diameters of 20-80 nm. Transmission electron microscopy and X-ray diffraction showed that the nanowires were wurtzite-structured ZnS single crystals. The Pt-functionalized ZnS nanowire sensors showed enhanced sensing performance to $NO_2$ gas at $150^{\circ}C$ compared to pristine ZnS nanowire sensors. Pristine and Pt-functionalized ZnS nanowire sensors showed responses of 140-211% and 207-488%, respectively, to 1-5 ppm $NO_2$, which are better than or comparable to those of many oxide semiconductor sensors. In addition, the underlying mechanism of the enhancement of the sensing properties of ZnS nanowires by Pt functionalization is discussed.

  • PDF

Effects of Additive and Preheat on the Partially Premixed $CH_4-Air$ Counter Flow Flames Considering Non-gray Gas Radiation

  • Park Won-Hee;Chang Hee-Chul;Kim Tae-Kuk
    • Journal of Mechanical Science and Technology
    • /
    • 제20권2호
    • /
    • pp.242-250
    • /
    • 2006
  • Detailed structures of the counterflow flames formed for different inlet fluid temperatures and different amount of additives are studied numerically. The detailed chemical reactions are modeled by using the CHEMKIN-II code. The discrete ordinates method and the narrow band based WSGGM with a gray gas regrouping technique (WSGGM-RG) are applied for modeling the radiative transfer through non-homogeneous and non-isothermal combustion gas mixtures generated by the counterflow flames. The results compared with those obtained by using the SNB model show that the WSGGM-RG is very successful in modeling the counterflow flames with non-gray gas mixture. The numerical results also show that the addition of $CO_2\;or\;H_2O$ to the oxidant lowers the peak temperature and the NO concentration in flame. But preheat of fuel or oxidant raises the flame temperature and the NO production rates. $O_2$ enrichment also causes to raise the temperature distribution and the NO production in flame. And it is found that the $O_2$ enrichment and the fuel preheat were the major parameters in affecting the flame width.

저온플라즈마에 의한 질소산화물의 제거에 관한 연구 (A Study on Removal of NOx by Low Temperature Plasma)

  • 박희재;이내우;최재욱;임우섭
    • Korean Chemical Engineering Research
    • /
    • 제48권4호
    • /
    • pp.540-543
    • /
    • 2010
  • 가스 중에 포함되어 있는 질소산화물을 안전하게 처리하기 위하여 저온 플라즈마 반응기를 제작하여 반응기내에 공급되는 반응물질의 유량과 방전주입전력량에 대한 장치의 특성을 실험적으로 조사하고, 유효성을 검정하였다. 반응가스는 $NO/N_2$ 혼합가스와 $N_2/O_2$ 혼합가스를 이용하여 초기 NO 농도를 설정하고, 유속을 1~4 l/min으로 공급하였다. 반응물질의 유량이 증가할 때 NO의 감소율이 낮고, 방전주입전력이 높을 때 NO의 분해가 용이하였다. 또한 반응물질의 지연시간이 길고 방전주입전력이 높을수록 NO의 분해에너지 효율이 높았으며, 유량이 많고 방전 주입 전력량이 증가할수록 오존의 생성량이 증가하였다.