• Title/Summary/Keyword: $NO_2$ Sensor

Search Result 600, Processing Time 0.031 seconds

Development of a New Training System for the Improvement of Equibrilium Sense (평형 감각 증진을 위한 새로운 훈련 장치의 개발)

  • Lee Jung Ok;Park Young Gun;No Pang Hwang;Hong Chul Un;Kim Nam Gyun
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.465-469
    • /
    • 2004
  • We propose a new training system for the improvement of equilibrium sense using unstable platform. This system consists of unstable platform, computer interface and various softwares. The unstable platform was a simple structure of elliptical-type which included tilt sensor and wireless RF module. To evaluate the effort of balance training, we measured the parameters such as the moving time to the target and duration to maintain cursor in the target of screen. Balance training was carried out for two weeks and we classified the subjects into two groups by the training program. As a result, the moving time was reduced and duration time was lengthened through the repeating training of equilibrium sense using training program of sine curve trace(SCT) and Block game. Especially, there was remarkable improvement at direction which was too difficult for the subjects to balance their body. It was showed that this system had an effort on improving equilibrium sense and might be applied to clinical use as an effective balance training system.

A Basic Study on Miniature Size Electrostatic Induction Meter (소형(小型) 정전(靜電) 유도형(誘導型) 모터의 기초(基礎) 연구(硏究))

  • Moon, Jae-Duk;Lee, Dong-Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.65-74
    • /
    • 1993
  • A miniature size electrostatic induction motor has been fabricated and studied with emphasis on the role of the surface resistivity, the relative dielectric constant and the charge relaxation time constant of the rotor surface materials and the rotor liner materials, which, however, control the surface charge induction and relaxation on the rotor material surface and the field intensity between the rotor and the stator of the motor. It is found that the surface resistivity and/or the relative dielectric constant, and the charge relaxation time constant of the rotor surface material enfluenced significantly to motor speed controlled by the surface charge induction and relaxation on the rotor surface depending on the applied voltage and/or frequency changing. The resistivity of the rotor liner material is also found to be effected to the motor speed greatly by control of the field intensity between the rotor and the stator and of the surface charge distribution of the induced charge on the rotor. As a result, a maximum no load rotor speed of the motor tested was about 5500 rpm at the applied voltage of 4.5 kV and the frequency of 220 Hz for the case of the rotor surface material of $BaTiO_{3}$ 80% in the resin binder layered on the copper-foil rotor liner material.

  • PDF

A Study on Light Condition between Pinus densiflora and Quercus variabilis Natural Mixed Forest Stands by Using the Hemispherical Photo Method (수관사진법을 이용한 소나무-굴참나무 천연림에 있어서의 광 조건 연구)

  • Chung Dong-Jun;Kim Young-Chai
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.1 no.2
    • /
    • pp.127-134
    • /
    • 1999
  • This study was performed to obtain the basic data to present rational silvicultural tending plan. It makes these widely distributed pine-oak mixed stand and each of pure stand in middle province on object of this study and do comparative analysis of light condition about stand parameter and natural regeneration according to each slope(north, west and south) conditions of location in central part of South Korea. Sample plots for pine-oak mixed stand and pine and oak pure stand were established on each of southern, northern and western slopes based upon site and growth conditions of the slope. Sample plot was a circle of 0.05ha with a diameter of 25.24 m. A sample plot has between 30 and 40 tree in it. Total 23 sample plots were established; 9 pure pine stands, 8 pine-oak mixed stands. and 6 pure oak stands across lower, middle, upper parts of slopes. Relative light intensity within a stand was' measured by crown- photo(fish-eye lens; 180$^{\circ}$) system through fish-eye lens and by comparing each plot with the denuded through PAR-sensor. The crown closure ratio of pure pine stand (75%) shows much lower than that of mixed stand (90.9%) and pure oak stand (93%). The relative light intensity within a stand showed an opposite result. The crown closure of mixed stands tended to become gradually low as the slope moves from the north to the south, but the relative light Intensity within the stand tended to rise. By analyzing the relationship between the relative light intensity within a stand and stand parameter, light intensity within a stand tended to decrease as the diameter and N/ha increase. Number of oak seedlings and light intensity within a stand is in a straight-line regression relation. In particular, the number of oak seedlings was the highest in mixed stands on the southern slope. But no single pine seedling was found. The unfavorable conditions of l0cm thick litter layer and low relative light intensity in a stand (ranging between 4% and 8%) is considered to prevent pine seeds from germinating.

  • PDF

Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics (연동펌프를 이용한 비료염 공급 관비재배기술 연구)

  • Kim, D.E.;Lee, G.I.;Kim, H.H.;Woo, Y.H.;Lee, W.Y.;Kang, I.C.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2015
  • This study was conducted to develop the fertigation system with a peristaltic hose pump and brushless DC motor. The fertigation system was consisted of sensor, main controller, motor control unit, peristaltic pump, water supply pump, control panel, and filter. The peristaltic pump discharges liquid by squeezing the tube with rollers. Rollers attached to the external circumference of the rotor compresses the flexible tube. The fluid is contained within a flexible tube fitted inside a circular pump casing. The developed fertigation system has no mixing tank but instead injects directly a concentrated nutrient solution into a water supply pipe. The revolution speed of the peristaltic pump is controlled by PWM (Pulse width modulation) method. When the revolution speed of the peristaltic pump was 300rpm, the flow rate of the 3.2, 4.8, 6.3mm diameter tube was 202, 530, 857mL/min, respectively. As increasing revolution speed, the flow rate of the peristaltic pump linearly increased. As the inner diameter of a tube larger, a slope of graph is more steep. Flow rate of three roller was more than that of four roller. Flow rate of a norprene tube with good restoring force was more than that of a pharmed tube. As EC sensor probe was installed in direct piping in comparison with bypass piping showed good performance. After starting the system, it took 16~17 seconds to stabilize EC. The maximum value of EC was 1.44~1.7dS/m at a setting value of 1.4dS/m. The developed fertigation system showed ±0.06dS/m deviation from the setting value of EC. In field test, Cucumber plants generally showed good growth. From these findings, this fertigation system can be appropriately suitable for fertigation culture for crops.

The Prevalence and Characteristics of Positional Obstructive Sleep Apnea

  • Kim, Cheon-Sik;Lee, Yong-Seok;Cho, Cheon-Ung;Pae, Sang-Ho;Lee, Sang-Ahm
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.2
    • /
    • pp.52-58
    • /
    • 2012
  • Patients with obstructive sleep apnea (OSA) often have more aggravated symptoms in the supine position. We tried to investigate the clinical characteristics and the predictive factors for positional OSA. Polysomnographic data were reviewed for OSA patients (apnea hypopnea index, $AHI{\geq}5$) from April, 2008 to April, 2011 at the Asan Medical Center. Clinical data, comorbid medical condition data and questionnaires (SF-36, MFI-20, ESS, BDI, STAI) were assessed. All patients were classified into two groups: positional patients (PP) group and non-positional patients (NPP) group. PP was defined as a patient who had the AHI in the supine position was at least twice as high as that in the lateral position. The body position of patients was confirmed by sleep position sensor and video monitor. All patients had at least 30 minutes of positional and 30 minutes of non-positional sleep. We compared clinical, medical, polysomnographic data, and questionnaire results between two (PP and NPP) groups and investigated predictive factors for the PP group using binary logistic regression analysis. In total, 371 patients were investigated. 265 (71.4%) was categorized as PP group and 106 (28.5%) as NPP group. The mean age ($mean{\pm}SD$) was higher in the PP group ($52.4{\pm}9.8$) than in the NPP group ($49.5{\pm}11.9$) (p<0.05). Comparison of sleep parameters between the PP and the NPP group showed that the PP group had significantly lower BMI (PP: $26.1{\pm}3.2kg/m^2$; NPP: $27.8{\pm}4.3kg/m^2$, p<0.001), neck circumference (PP: $39.7{\pm}2.8cm$; NPP: $41.5{\pm}3.7cm$, p<0.001) and hypertension rate (PP: n=89/265 (33.5%); NPP: n=48/106 (45.2%), p=0.0240). In the PP group, the percentage of deep sleep (PP: $8.7{\pm}8.1%$; NPP: $5.6{\pm}7.0%$, P=0.001) and rapid eye movement (REM) (PP: $17.5{\pm}6.1%$; NPP: $14.0{\pm}6.9%$, p<0.001) were significantly higher whereas the percentage of light sleep (stage N1) was significantly lower than the NPP group (PP: $30.4{\pm}12.3$; NPP: $44.5{\pm}20.8%$, p<0.001). During the sleep, the AHI in the supine position (PP: $48.6{\pm}19.5$; NPP: $60.5{\pm}22.6$, p<0.001) and in the non-supine position (PP: $9.4{\pm}8.9$; NPP: $48.4{\pm}24.8$, p=<0.001) were significantly lower and the minimal arterial oxygen saturation in non-REM sleep was significantly higher in the PP group (PP: $80.3{\pm}7.6$; NPP: $75.1{\pm}9.9$, p=<0.001). There were no significant differences in all questionnaires including quality of life. The results of the binary logistic regression analysis showed that age, the amount of REM sleep(%) and AHI were significant predictive factors for positional OSA. The significant predictive factors for positional OSA were older age, higher percentage of REM and lower AHI. The questionnaire results were not significantly different between the two groups.

  • PDF

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF

Quality Characteristics of Jochung Containing Various Level of Letinus edodes Powder (표고버섯 가루를 이용한 조청의 품질 특성)

  • Park, Jung-Suk;Na, Hwan-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.768-775
    • /
    • 2005
  • Lentinus edodes powder was added at 1-3%(w/w) to improve functional properties of jocheong. Content of crude protein, ash, crude lipids, total mineral, free sugar and reducing sugar increased with increasing amount of L. edodes powder, while viscosity and solid and carbohydrate contents decreased. Through amino acid analysis, 17 amino acids were identified and quantified, glutamic acid being the major amino acid. No significant differences were observed in fatty acid composition and pH between control and L. edodes powder-added jocheong. Addition of mushroom powder in jocheong decreased lightness, yellowness and redness in Hunter's color value. Sensor score of jucheong containing 1% of L. edodes powder was similar to that of control. Results showed jocheong containing less than 2% L. edodes powder gave highest scores in quality characteristics and sensory evaluation.

Prediction Formulas of Pulmonary Function Parameters Derived from the Forced Expiratory Spirogram for Healthy Nonsmoking and Smoking Adults and Effect of Smoking on Pulmonary Function Parameters (비흡연 및 흡연 성년 한국인에서의 노력성호기곡선을 이용한 폐활량측정법 검사지표들의 추정상치 및 이에 대한 흡연의 효과)

  • Cho, Won-Kyoung;Kim, Eun-Ok;Myung, Seung-Jae;Kwak, Seung-Min;Koh, Youn-Suck;Kim, Woo-Sung;Lee, Moo-Song;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.5
    • /
    • pp.521-530
    • /
    • 1994
  • Background : The past studies on prediction formulas of pulmonary function parameters in healthy nonsmoking Korean adults have been performed in relatively small number of subjects and the reported results were restricted on a few parameters. Also there was no systematic investigation into the effect of smoking on pulmonary function parameters in smokers who have no respiratory symptoms. Therefore we attempted to establish prediction formulas of pulmonary function parameters and examined the effect of smoking on pulmonary function parameters. Methods We analyzed the result of parameters derived from the forced expiratory spirogram in 1,067 nonsmoking subjects from June in 1990 to December in 1991. They consisted of 306 males and 761 females and had neither respitatory symptoms nor history of respiratory disease. We derived prediction formulas by multiple linear regression method from their age, heights, and weights in each sex. To examine the effect of smoking on pulmonary function parameters, we classified 383 smoking men into three groups according to the past amount of smoking as follows : i.e. group of smokers who have smoked below 10 pack-years, 10-20 pack-years and above 20 pack-years. Regarding each group of past smoking as an independent dummy variable, we analyzed pulmonary function parameters including nonsmoking men as a baseline by multiple linear regression. We evaluated the smoking effect on pulmonary function parameters according to estimated p-value. Result : 1) Prediction formulas for pulmonary function parameters in each sex were derived. 2) The past smoking less than 10 pack-years does not give any effect on pulmonary function parameters. The past smoking of 10~20 pack-years showed significant negative correlation with $FEV_1$/FVC and FEF 25~75%, and the smoking above 20 pack years showed negative correlation with $FEV_1$ and $FEV_1$/FVC. Conclusion : We have got prediction formulas of pulmonary function parameters which is driven from forced expiratory spirogram in nonsmoking Korean adults by multiple linear regression from age, heights and weights of subjects. The past smoking more than 10 pack-years showed negative correlation with some pulmonary function parameters of airflow obstruction.

  • PDF

Research for Space Activities of Korea Air Force - Political and Legal Perspective (우리나라 공군의 우주력 건설을 위한 정책적.법적고찰)

  • Shin, Sung-Hwan
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.18
    • /
    • pp.135-183
    • /
    • 2003
  • Aerospace force is a determining factor in a modem war. The combat field is expanding to space. Thus, the legitimacy of establishing aerospace force is no longer an debating issue, but "how should we establish aerospace force" has become an issue to the military. The standard limiting on the military use of space should be non-aggressive use as asserted by the U.S., rather than non-military use as asserted by the former Soviet Union. The former Soviet Union's argument is not even strongly supported by the current Russia government, and realistically is hard to be applied. Thus, the multi-purpose satellite used for military surveillance or a commercial satellite employed for military communication are allowed under the U.S. principle of peaceful use of space. In this regard, Air Force may be free to develop a military surveillance satellite and a communication satellite with civilian research institute. Although MTCR, entered into with the U.S., restricts the development of space-launching vehicle for the export purpose, the development of space-launching vehicle by the Korea Air Force or Korea Aerospace Research Institute is beyond the scope of application of MTCR, and Air Force may just operate a satellite in the orbit for the military purpose. The primary task for multi-purpose satellite is a remote sensing; SAR sensor with high resolution is mainly employed for military use. Therefore, a system that enables Air Force, the Korea Aerospace Research Institute, and Agency for Defense Development to conduct joint-research and development should be instituted. U.S. Air Force has dismantled its own space-launching vehicle step by step, and, instead, has increased using private space launching vehicle. In addition, Military communication has been operated separately from civil communication services or broadcasting services due to the special circumstances unique to the military setting. However, joint-operation of communication facility by the military and civil users is preferred because this reduces financial burden resulting from separate operation of military satellite. During the Gulf War, U.S. armed forces employed commercial satellites for its military communication. Korea's participation in space technology research is a little bit behind in time, considering its economic scale. In terms of budget, Korea is to spend 5 trillion won for 15 years for the space activities. However, Japan has 2 trillion won annul budget for the same activities. Because the development of space industry during initial fostering period does not apply to profit-making business, government supports are inevitable. All space development programs of other foreign countries are entirely supported by each government, and, only recently, private industry started participating in limited area such as a communication satellite and broadcasting satellite, Particularly, Korea's space industry is in an infant stage, which largely demands government supports. Government support should be in the form of investment or financial contribution, rather than in the form of loan or borrowing. Compared to other advanced countries in space industry, Korea needs more budget and professional research staff. Naturally, for the efficient and systemic space development and for the prevention of overlapping and distraction of power, it is necessary to enact space-related statutes, which would provide dear vision for the Korea space development. Furthermore, the fact that a variety of departments are running their own space development program requires a centralized and single space-industry development system. Prior to discussing how to coordinate or integrate space programs between Agency for Defense Development and the Korea Aerospace Research Institute, it is a prerequisite to establish, namely, "Space Operations Center"in the Air Force, which would determine policy and strategy in operating space forces. For the establishment of "Space Operations Center," policy determinations by the Ministry of National Defense and the Joint Chief of Staff are required. Especially, space surveillance system through using a military surveillance satellite and communication satellite, which would lay foundation for independent defense, shall be established with reference to Japan's space force plan. In order to resolve issues related to MTCR, Air Force would use space-launching vehicle of the Korea Aerospace Research Institute. Moreover, defense budge should be appropriated for using multi-purpose satellite and communication satellite. The Ministry of National Defense needs to appropriate 2.5 trillion won budget for space operations, which amounts to Japan's surveillance satellite operating budges.

  • PDF