• 제목/요약/키워드: $NO_2$ Sensor

검색결과 604건 처리시간 0.031초

An Optical Intense 2D Electric Field Sensor Using a Single LiNO3 Crystal

  • Zhang, Yuanying;Zhang, Jiahong;Li, Yingna;Lei, Hongyi
    • Current Optics and Photonics
    • /
    • 제6권2호
    • /
    • pp.183-190
    • /
    • 2022
  • Based on the linear electro-optic (EO) effect of lithium niobite (LiNbO3, LN) crystal, an intense two-dimensional (2D) electric field sensor was analyzed, fabricated and experimentally demonstrated. The linear polarized light beam transmits along the optical axis (z-axis) of the LN crystal, and the polarization direction of the polarized light is 45° to the y-axis. The sensor can detect the intensity of a 2D electric field that is perpendicular to the z-axis. Experimental results demonstrated that the minimum detectable electric field of the sensor is 10.5 kV/m. The maximum detected electric field of the sensor is larger than 178.9 kV/m. The sensitivity of the sensor is 0.444 mV/(kV·m-1). The variation of the sensitivity is within ±0.16 dB when the sensor is rotated around a z-axis from 0° to 360°. The variation of the sensor output optical power is within ±1.4 dB during temperature change from 19 ℃ to 26 ℃ in a day (from 7:00 AM to 23:00 PM) and temperature change from 0 ℃ to 40 ℃ in a controllable temperature chamber. All theoretical and experimental results revealed that the fabricated sensor provides technology for the direct detection of intense 2D electric fields.

폐수의 악취측정을 위한 금속산화물 반도체 및 전기화학식 가스센서 어레이 특성 평가 (Evaluation of Metal Oxide Semiconductor and Electrochemical Gas Sensor Array Characterization for Measuring Wastewater Odor)

  • 임봉빈;이석준;김선태
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.29-34
    • /
    • 2015
  • This study aimed to evaluate the characterization of a metal oxide semiconductor and electrochemical gas sensor array for measuring wastewater odor. The sensitivity of all gas sensors observed in sampling method by stripping was 6.7 to 20.6 times higher than that by no stripping, except sensor D (electrochemical gas sensor). The average reduction ratio of sensor signal as a function of initial dilution rate of wastewater was in the order of food plant > food waste reutilization facility > plating plant. The sensitivity of gas sensors was dependent on both the type of wastewater and the dilution rate. The sensor signals observed by the gas sensor array were correlated with the dilution factor (OU) calculated by the air dilution sensory test with several wastewater ($r^2=0.920{\sim}0.997$), except the sensor signals of sensor D measured in the plating plant wastewater. It seems likely that the gas sensor array plays a role in the evaluation of odor in wastewater and is useful tool for on-site odor monitoring in the wastewater facilities.

CNG 대형엔진에서 이중 O2 센서를 활용한 피드백 제어를 통한 삼원촉매 정화효율 향상 (Feedback Control using Dual O2 Sensors for Improving the Conversion Efficiency of a Three-way Catalyst in a Heavy-duty CNG Engine)

  • 윤성준;이준순;박현욱;이용규;김창업;오승묵
    • 한국분무공학회지
    • /
    • 제24권4호
    • /
    • pp.163-170
    • /
    • 2019
  • In this study, feedback logic using dual O2 sensor values were developed to increase the purification capability of a three-way catalyst (TWC) in a compressed natural gas (CNG) engine. A heavy-duty inline 6-cylinder engine was used and the CNG was supplied to the engine through a mixer. This study consists of two main parts, namely, the proportional integral (PI) control with a front O2 sensor and the feedback control with dual O2 sensors. In the PI control experiment, effects of various parameters, such as P gain, I gain, and lean delay, on the TWC capability were identified. Based on the results of the PI control experiment, the feedback logic using dual O2 sensor values were developed. In both cases, the nitrogen oxides (NOX) emissions were nearly zero. However, the carbon monoxide (CO) emissions were reduced significant in the feedback logic with dual O2 sensors than in the PI control with the front O2 sensor.

피치계 활성탄소섬유기반 가스센서 제조 및 유해가스 감응 특성 (Preparation of Gas Sensor from Pitch-based Activated Carbon Fibers and Its Toxic Gas Sensing Characteristics)

  • 김민일;이영석
    • 공업화학
    • /
    • 제25권2호
    • /
    • pp.193-197
    • /
    • 2014
  • 피치계 활성탄소섬유의 유해가스 감응특성을 알아보고자 피치계 활성탄소섬유와 폴리비닐알코올(PVA)을 이용하여 가스센서용 전극을 제조하였다. 제조된 가스센서용 활성탄소섬유 전극의 물리화학적 특성은 주사전자현미경(SEM) 및 비표면적 측정기(BET)를 이용하여 분석하였다. 또한, 전극의 유해가스 감응특성은 $NH_3$, NO 및 $CO_2$와 같은 여러 유독가스를 이용하여 확인하였다. 가스센서용 활성탄소섬유 전극의 비표면적은 바인더인 PVA에 의하여 활성탄소섬유보다 33% 감소하였지만, 전극의 기공크기분포는 PVA에 의하여 크게 영향을 받지 않았다. 가스센서용 활성탄소섬유 전극은 반도체 기반 가스센서와는 다르게 전자도약에 의해서 유해가스를 감응하였다. 본 연구에서, 활성탄소섬유 전극의 저항은 100 ppm의 $NH_3$ 유해가스에 대하여 7.5% 감소하였으며, 그 $NH_3$ 가스 감응특성이 다른 유해가스보다 뛰어남을 확인하였다.

수경재배용 배양액의 이온성분 분석을 위한 고체형 센서 모듈 개발 (Development of a Solid State Ion Sensor Module for Analysis of Hydroponic Nutrients)

  • 김기영;이상봉;장영창
    • Journal of Biosystems Engineering
    • /
    • 제32권5호
    • /
    • pp.348-353
    • /
    • 2007
  • A solid state ion sensor module has been developed and evaluated for hydroponic nutrients analysis. The sensor module consisted of five ion-selective electrodes (ISE) fabricated by screen-printing technology. The electrochemical responses of ion sensors for nitrate, ammonium, potassium, calcium, and pH were measured with specially designed 7-channel low voltage signal transducers. The analytical characteristics of the sensors were comparable with those of conventional ISE sensors. The solid state ion sensors exhibit linear relationships over five concentration decades. Detection limit of the sensors were $5.6{\times}10^{-5}{\sim}1.6{\times}10^{-7}M$ depends on ions. Performance test results showed that relative errors of measured ion concentrations were less than 5% for $NO_3{^-},\;K^+,\;Ca^{2+}$ ion, and pH. The concentration of $NO_3{^-},\;NH_4{^+},\;K^+,\;Ca^{2+}$, and pH ion in standard solution and nutrient solutions could be determined by direct potentiometric measurements without any conditioning before measurements.

구현방식이 용이한 텍스타일 터치센서 개발 및 구조적 설계 (Development and Structural Design of Textile Touch Sensor Easily Implemented)

  • 김지선;박진희;김주용
    • 한국의류학회지
    • /
    • 제45권1호
    • /
    • pp.168-179
    • /
    • 2021
  • This study presents and develops a textile type touch sensor structural design that is easy to implement. First, the design of the touch sensor circuit finds the size of the switch with the easiest finger contact and selects a structure with a long circuit with the lowest resistance value. An experiment is performed on a change in an electrostatic capacitance value that accompanies the distance on the electrode and the magnitude of the electrode area of the structure; however, the structure having the distance on the electrode and the large electrode area shows the best resistance change. The laundry assessment was conducted three times at a time and ten times at a time with an average standard deviation less than one ohm, with little change in resistance. Consequently, there were no problems with durability and performance for laundry. Finally, in the bending evaluation, the difference in resistance can be seen between 1-2 ohms and was developed as a smart wearable in the future; in addition, there was no problem as a difference in resistance can be seen between 1 and 2 ohms.

Gas-Flow Sensor using Optical Fiber Bragg Grating(FBG)

  • Shim, Joon-Hwan;Cho, Seok-Je;Yu, Yung-Ho;Sohn, Kyung-Rak
    • 한국항해항만학회지
    • /
    • 제32권9호
    • /
    • pp.717-722
    • /
    • 2008
  • We have proposed and demonstrated an gas-flow sensor using optical fiber bragg grating(FEG). The flow sensor has no electronics and no mechanical parts in its sensing part and the structure is th11s simple and immune to electromagnetic interference(EMI). The FEG sensor was consisted qf the sensing element and a coil heater. The metal coil was used to supply the current to the FEG. While some currents supply to the coil, the refractive index of the FEG under the coil is changed and thus the wavelength shift of fiber optic sensor was induced In this work, the wavelength shift according to flow-rate was experimentally studied and was used to evaluate the gas flow-rate in a gas tube. As a result, it was possible to measure the flow-rate in a linear range from 5 to $20{\ell}/min$ with a resolution of approximately $1{\ell}/min$ at the applied currents of 100 mA and 120 mA. The measured sensitivities were $15.3\;pm/\ell/min$ for 100 mA and $20.2\;pm/\ell/min$ for 120 mA.

Synthesis and Sensing Properties of Pd Nanoparticle-Functionalized SnO2 Nanowires

  • Akash, Katoch;Choi, Sun-Woo;Kim, Eun-Kyeong;Kim, Sang-Sub
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.289-293
    • /
    • 2011
  • Networked $SnO_2$ nanowires were uniformly functionalized with Pd nanoparticles via ${\gamma}$-ray radiolysis. The Networked $SnO_2$ nanowires were fabricated through a selective growth method. The sensing properties of the Pd-functionalized $SnO_2$ nanowires were analyzed in terms of their response to $NO_2$ and CO gases. The response time and sensitivity of the sensors were significantly improved for $NO_2$ at lower temperatures by the Pd functionalization. The enhancement in the sensing properties is likely to be due to the spillover effect of the Pd nanoparticles.

신경인지 검사를 위한 모션 센싱 시스템 (Motion Sensing System for Automation of Neuropsycological Test)

  • 조원서;천경민;류근호
    • 센서학회지
    • /
    • 제26권2호
    • /
    • pp.128-134
    • /
    • 2017
  • Until now, neuropsychological tests can diagnose the brain dysfunction, however, cannot distinguish the objective data of experiment enough to distinguish the relationships between brain dysfunction and cerebropathia. In this paper, an automatic cognitive test equipment system with 6-axis motion sensors was proposed for the automation of neuropsychological tests. Fist-Edge-Palm(FEP) test and Go-no go test were used to evaluate motor programming of frontal lobe. The motion data from the specially designed motion glove are transmitted wirelessly to a computer to detect the gestures automatically. The healthy 20 and 11 persons are investigated for the FEP and Go-No go test, respectively. The recognition rates of gestures of FEP and Go-No go test are min. 91.38% and 89.09%. In conclusion, the automations of cognitive tests are successful to diagnose the brain diagnostics quantitatively.