• Title/Summary/Keyword: $L_2$ 이득

Search Result 224, Processing Time 0.023 seconds

The Clinical Significance of Follow Up SCC Levels in Patients with Recurrent Squamous Cell Carcinoma of the Cervix (재발성 자궁경부 편평상피암 환자들에서 Squamous Cell Carcinoma 항원의 유용성)

  • Choi Young Min;Park Sung Kwang;Cho Heung Lae;Lee Kyoung Bok;Kim Ki Tae;Kim Juree;Sohn Seung Chang
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.353-358
    • /
    • 2002
  • Purpose : To investigate the clinical usefulness of a follow-up examination using serum squamous cell carcinoma antigen (SCC) for the early detection of recurrence in patients treated for conical squamous cell carcinoma. Materials and Methods : 20 patients who were treated for recurrent cervical squamous cell carcinoma between 1997 and 1998, who had experienced a complete remission after radiotherapy and who underwent an SCC test around the time when recurrence was detected, were included in this study. The levels of SCC were measured from the serum of the patients by immunoassay and values less than 2 ng/mL were regarded as normal. The sensitivity of the SCC test for use in the detection of recurrence, the association between the SCC values and the recurrence patterns and the tumor size and stage, and the temporal relation between the SCC increment and recurrence detection were evaluated. Results : The SCC values were above normal in 17 out of 20 patients, so the sensitivity of the SCC test for the detection of recurrence was $85\%$, and the mean and median of the SCC values were 15.2 and 9.5 ng/mL, respectively. No differences were observed in the SCC values according to the recurrence sites. For 11 patients, the SCC values were measured over a period of 6 months before recurrence was detected, and the mean and median values were 13.6 and 3.6 ng/mL, respectively. The SCC values of 7 patients were higher than the normal range, and the SCC values of the other 4 patients were normal but 3 among them were above 1.5 ng/mL. At the time of diagnosis, the SCC valuess were measured for 16 of the 20 recurrent patients, and the SCC values of the patients with a bulky tumor $(\geq4\;cm)$ or who were in stage IIb or III were higher than those of the patients with a non-bulky tumor or who were in stage Ib or IIa. Conclusion : The SCC test is thought to be useful for the early detection of recurrence during the follow up period in patients treated for cervical squamous cell carcinoma. When an effective salvage treatment is developed in the future, the benefit of this follow-up SCC test will be increased.

DC ∼ 45 GHz CPW Wideband Distributed Amplifier Using MHEMT (MHEMT를 이용한 DC ∼ 45 GHz CPW 광대역 분산 증폭기 설계 및 제작)

  • Jin Jin-Man;Lee Bok-Hyung;Lim Byeong-Ok;An Dan;Lee Mun-Kyo;Lee Sang-Jin;Ko Du-Hyun;Beak Yong Hyun;Oh Jung-Hun;Chae Yeon-Sik;Park Hyung-Moo;Kim Sam-Dong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.12
    • /
    • pp.7-12
    • /
    • 2004
  • In this paper, CPW wideband distributed amplifier was designed and fabricated using 0.1 $\mum$ InGaAs/InAlAs/GaAs Metamorphic HEMT(High Electron Mobility Transistor). The DC characteristics of MHEMT are 442 mA/mm of drain current density, 409 mS/mm of maximum transconductance. The current gain cut-off frequency(fT) is 140 GHz and the maximum oscillation frequency(fmax) is 447 GHz. The distributed amplifier was designed using 0.1 $\mum$ MHEMT and CPW technology. We designed the structure of CPW curve, tee and cross to analyze the discontinuity characteristics of the CPW line. The MIMIC circuit patterns were optimized electromagnetic field through momentum. The designed distributed amplifier was fabricated using our MIMIC standard process. The measured results show S21 gain of above 6 dB from DC to 45 GHz. Input reflection coefficient S11 of -10 dB, and output reflection coefficient S22 of -7 dB at 45 GHz, respectively. The chip size of the fabricated CPW distributed amplifier is 2.0 mm$\times$l.2 mm.

Transparent Rectangular Patch Antenna Using Square Metal Mesh Transparent Electrode (정방형 메탈메쉬 투명전극을 이용한 투명 사각 패치 안테나)

  • Kang, Seok Hyon;Jung, Chang Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.277-284
    • /
    • 2018
  • This paper reports the transparent electrode, which would be applied to transparent displays and smart glasses. Herein, a squared metal mesh with the most widely used copper wire in microwaves is studied for the alternating thin-film-type transparent and conducting indium tin oxide(ITO), with a low conductivity(sheet resistance > $5{\Omega}/sq.$). The electromagnetic performance of a patch antenna with metal mesh is analyzed. This paper presents the results of the optical(OT, optical transparent) and electrical(sheet resistance) characteristics of a squared metal mesh, which is a basic design. To improve the OT, copper wire(w=0.2 mm) is used in fabricating the squared metal mesh and the relationship between the OT and the antenna performance(radiation gain, radiation pattern) was analyzed according to the mesh size(l=1, 2 mm). The measurement results show that the antenna performance and the optical characteristic are in inverse proportion to each other. In real applications, the optical and electrical characteristics, and the costs of production are to be considered.

Error Performance Analysis of DS/CDMA-Trellis Coded QPSK Signal with MRC Diversity Reception in Wireless Data Communication (무선 데이터 통신에서 MRC 다이버시티 수신시의 DS/CDMA-Trellis Coded QPSK 신호의 오율 해석)

  • 노재성;김영철;박기식;강희조;조성준
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.3
    • /
    • pp.317-329
    • /
    • 1998
  • In this paper, we have analyzed the packet error probability of DS/CDMA-Trellis Coded QPSK modulation signal with MRC(Maximum Ratio Combining) diversity reception in Rician fading, multi-user interferences and multipath channel. And then we have evaluated the performance and capacity of DS/CDMA-Trellis Coded QPSK system using the MRC diversity reception as a function of direct power to indirect power ratio ($K_R$), the number of diversity branch(M), the number of multi-user(U), PN chip rate(PN), the number of multipath channel($L_P$), and packet length(PL). From the results, we know that the coding gain of DS/CDMA-Trellis Coded QPSK system with 2 branch MRC diversity is about 6 dB against uncoded DS/CDMA BPSK system with 2 branch MRC diversity in Rician fading ($K_R=6dB), 5 multi-user interferences, and 3 multipath channel. And, we know that coded QPSK signal designed for the AWGN channel also perform well on a Rician fading channel with MRC diversity reception. Consequently, we expected that proposed system structure is reliable to the wireless data communication system in Rician fading, multi-user interferences, and multipath channel.

  • PDF

A Study on the Ultra Small Size 25 Watt High Power Amplifier for Satellite Mobile Communications System at L-Band (L-band 위성통신 시스템을 위한 극소형 25 Watt 고출력증폭기에 관한 연구)

  • Jeon, Joong-Sung;Ye, Byeong-Duck;Kim, Dong-Il
    • Journal of Navigation and Port Research
    • /
    • v.26 no.1
    • /
    • pp.22-27
    • /
    • 2002
  • The 25 Watt hybrid MIC SSPA has been developed in the frequency rang from 1.6265 GHz to 1.6465 GHz for uplink of INMARST's earth station. To simplify the fabrication process, the whole system is designed of two parts composed of a friving amplifier and a power amplifier. The Motorolas MRF-6401 is used for driving part, the Motorolas MRF-16006 and MRF-16030 is used the power amplifier. We reduced weight and volume of high power amplifier through arranging the bias circuits in the same housing. The realized SSPA has more than 30 dB for gain within 20 MHz bandwidth, and the voltage standing wave ratios(VSWR) of input and output port are less than 1.7, respectively. The output power of 44 dBm is achieved at the 1 dB gain compression point of 106365 GHz These results reveal a high power amplifier of 25 Watt which is the design target. The Proposed SSPA manufacture techniques in this paper can be applied to the implementation of high power amplifiers for some radars and SCPC.

Cytotoxicity and Antigenotoxic Effects of Cordyceps militaris Extracts (번데기동충하조(Cordyceps militaris) 추출물의 세포독성 및 유전독성 억제효과)

  • 김미남;최승필;이득식;함승시
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.5
    • /
    • pp.921-927
    • /
    • 2001
  • This study was performed to investigated the effects on the cytotoxicity and antigenotoxicity of Cordyceps militaris extracts on the human cancer cell lines. The ethanol extract and five fractions which were hexane, chloroform, ethylacetate, butanol and aqueous were screened for crytotoxicity on human lung carcinoma(A549). human breast adenocarcinoma (MCF-7) human epitheloid carcinoma(HeLa), human fibrosarcoma(HT1080) human hepatocellular carcinoma(Hep3B), human gastric carcinoma(KATOIII) and chronic myelogenous leukemia(K562) cell by SRB and MTT assays. The results showed that growth inhibition rates of the human cancer cell in the presence of Cordyceps militaris were inhibited with increasing concentration of the extract. The ethanol extract from Cordyceps militaris had strong inhibitory effects in1 mg/mL treatment by SRB assay , showing 89.4%, 85.7%, 72.9% and 65.5% inhibition in HT1080, HeLa, Hep3B and A549, respectively. The treatment of 1 mg/mL hexane fraction by SRB assay had the strongest cytotoxicity with 97.0% on HT1080 followed by MCF-7(92.9%) and HeLA(90.3%). The inhibition ration on KATOIII by MTT assay was much higher in the butanol (83.7%) and aqueous (80.4%) than in the ethanol extract (61.5%) And also, K562 showed similar tendency with KATOIII. The effects of Cordyceps militaris extracts on the frequencies of micronucleated polychromatic erythrocytes (MNPCEs) induced by N-methyl-N-nitro-N-nitrosoguanidime(MNNG) were investigated in the bone-marrow cells of ICR male mice. The amount of 10, 20, 40 and 80 mg/kg of each extract were administered to animals immediately after injection of MNNG, and the exposure time was 36 hours. Significant reductions(p<0.05) with 39.7%, 52.7%, 71.4% and 83.9% were observed in the frequencies of MNPCE when 10, 20, 40 and 80 mg/kg of the hexane fraction of Coryceps militarus extracts were given to the mice.

  • PDF

Development of Position Encoding Circuit for a Multi-Anode Position Sensitive Photomultiplier Tube (다중양극 위치민감형 광전자증배관을 위한 위치검출회로 개발)

  • Kwon, Sun-Il;Hong, Seong-Jong;Ito, Mikiko;Yoon, Hyun-Suk;Lee, Geon-Song;Sim, Kwang-Souk;Rhee, June-Tak;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.469-477
    • /
    • 2008
  • Purpose: The goal of this paper is to present the design and performance of a position encoding circuit for $16{\times}16$ array of position sensitive multi-anode photomultiplier tube for small animal PET scanners. This circuit which reduces the number of readout channels from 256 to 4 channels is based on a charge division method utilizing a resistor array. Materials and Methods: The position encoding circuit was simulated with PSpice before fabrication. The position encoding circuit reads out the signals from H9500 flat panel PMTs (Hamamatsu Photonics K.K., Japan) on which $1.5{\times}1.5{\times}7.0\;mm^3$ $L_{0.9}GSO$ ($Lu_{1.8}Gd_{0.2}SiO_{5}:Ce$) crystals were mounted. For coincidence detection, two different PET modules were used. One PET module consisted of a $29{\times}29\;L_{0.9}GSO$ crystal layer, and the other PET module two $28{\times}28$ and $29{\times}29\;L_{0.9}GSO$ crystal layers which have relative offsets by half a crystal pitch in x- and y-directions. The crystal mapping algorithm was also developed to identify crystals. Results: Each crystal was clearly visible in flood images. The crystal identification capability was enhanced further by changing the values of resistors near the edge of the resistor array. Energy resolutions of individual crystal were about 11.6%(SD 1.6). The flood images were segmented well with the proposed crystal mapping algorithm. Conclusion: The position encoding circuit resulted in a clear separation of crystals and sufficient energy resolutions with H9500 flat-panel PMT and $L_{0.9}GSO$ crystals. This circuit is good enough for use in small animal PET scanners.

A Study on the Design of Ku-band Mixer Using a HEMT (HEMT를 이용한 Ku-band 혼합기의 설계에 관한 연구)

  • 성혁제;구자건
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.7
    • /
    • pp.944-950
    • /
    • 1993
  • Diodes and GaAs have been commonly used in a mixer design until recently. However, diodes are not preferred to use at the front-end of DBS receiver due to the conversion loss large noise. HEMT has larger conversion gain and better noise characteristics comparing with GaAs MESFET. This paper describes the design procedure, structure, and performance of a mixer, utilizaing HEMT designed by OKI Co. . A mixer configuration in which the local oscillator(LO) signal is applied to the gate is used. When the LO power is 0.01 dBm, the conversion gain of 3.7dB is obtained at IF and the 3 dB bandwidth is 400MMz.

  • PDF

Design of UWB Antenna with Fork-type structure and circular patch (원형 패치와 포크형 구조가 결합된 UWB 안테나)

  • Ha, Yun-Sang;Kim, Gi-Rae;Choi, Young-Kyu;Yun, Joong-Han
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1837-1844
    • /
    • 2016
  • This paper proposes an antenna of the fork type structure that operates in the UWB (Ultra Wide Band) frequency band (3.1 ~ 10.6 GHz). The proposed antenna is attached a circular patch in order to obtain the UWB band characteristics to the fork-type patch antenna. The ground plane is implemented in a arc-shape configuration. The effect of various parameters of the modified fork type radiating patch and partial arc ground plane for UWB operation is investigated. The proposed antenna is made of $34.0{\times}50.0{\times}1.0mm^3$ and is fabricated on the permittivity 4.4 FR-4 substrate. The experiment results shown that the proposed antenna obtained the -10 dB impedance bandwidth 8200 MHz (2.7 ~ 10.9 GHz) covering the UWB bands. This result satisfied the characteristics of ultra-wideband and the proposed antenna will be applicable to an ultra wideband system.

Synthesis and Characterization of Porous Poly(ε-caprolactone)/Silica Nanocomposites (다공성 폴리(ε-카프로락톤)/실리카 복합체의 제조 및 특성평가)

  • Son, Siwon;Choi, Ji-Eun;Cho, Hun;Kang, DaeJun;Lee, Deuk Yong;Kim, Jin-Tae;Jang, Ju-Woong
    • Polymer(Korea)
    • /
    • v.39 no.2
    • /
    • pp.323-328
    • /
    • 2015
  • Poly(${\varepsilon}$-caprolactone) (PCL) nanofibers and PCL/silica membranes were synthesized by sol-gel derived electrospinning and casting, respectively. Smooth PCL nanofibers were obtained from the precursor containing N,N-dimethylformamide (DMF). PCL/silica membranes were prepared by varying the tetraethyl orthosilicate (TEOS) contents from 0 to 40 vol% to investigate the effect of silica addition on mechanical properties and cytotoxicity of the membranes. Although the strength of the membranes decreased from 12 to 8 MPa with increasing the silica content, the strength remained almost constant 7 weeks after dipping in phosphate buffered saline solution (PBS). The strength reduction was attributed to the presence of a patterned surface pores and micro-pores present in the walls between pores. The crystal structure of the membranes was orthorhombic and the crystallite size decreased from 57 to 18 nm with increasing the silica content. From the agar overlay test, the PCL/silica membranes exhibited neither deformation and discoloration nor lysis of L-929 fibroblast cells.