• 제목/요약/키워드: $LN_2$(Liquid Nitrogen)

검색결과 146건 처리시간 0.02초

Liquid Nitrogend의 감찰효과 -물리적 현상에 의한 절삭력- (The Lubrication Effect of Liquid Nitrogen in Cryogenic Machining [I]- Part 1: Cutting Force Component with Physical Evidences -)

  • Jun Seong Chan;Jeong Woo Cheol
    • 대한안전경영과학회지
    • /
    • 제4권2호
    • /
    • pp.209-221
    • /
    • 2002
  • Machinability improvement by the use of liquid nitrogen in cryogenic machining has been reported in various studies. This has been mostly attributed to the cooling effect of liquid nitrogen. However, No study has been found in discussion on whether liquid nitrogen possesses lubrication effect in cryogenic cutting. In machining tests, cryogenic machining reduced the force component in the feed direction, indicating that the chip slides on the tool rake face with lower friction. This study also found that the effectiveness of LN2 lubrication depends on the approach how LN2 is applied regarding cutting forces related.

Liquid Nitrogen의 감찰 효과 -공구 마모에 의한 마찰 계수 이론적 전개- (The Lubrication Effect of Liquid Nitrogen in Cryogenic Machining [?$\pm$]-Part 2: Tool Wear and Chip Microstructures-)

  • Jun Seong Chan;Jeong Woo Cheol
    • 대한안전경영과학회지
    • /
    • 제4권2호
    • /
    • pp.223-235
    • /
    • 2002
  • This paper presents some indirect physical evidences indicating that reduced friction occurs in an economical cryogenic machining process, in which LN2 is applied selectively in well-controlled jets to the localized cutting zone. These evidences include cutting force components, tool wear rate and chip morphology. LN2 reduced the tool wear rate to a great extent and elongated the tool life up to four times compared to emulsion cooling. The friction reduction was further reflected in larger shear angle and less secondary deformation in the chip microstructures. This study also found that the effectiveness of LN2 lubrication depends on the approach how LN2 is applied.

Pancake coil형 고온초전도 기기의 응용을 위한 극저온 냉매의 절연파괴 특성 (Breakdown Properties of Cryogenic Coolant for Pancake Coil Type High $T_{c}$ Superconducting Equipment)

  • 백승명;정종만;이진호;김상현
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.185-188
    • /
    • 2002
  • In the design of superconducting power equipments such as transformer, cable and fault current limit, knowledge of the dielectric behavior of both liquid and gaseous at very low temperatures is very importance. Especially, Electrical properties of liquid nitrogen($LN_{2}$) and gaseous nitrogen($GN_{2}$) have become of great interest again since the discovery of high temperature superconductors. However, many sources of $LN_{2}$and $GN_{2}$ problems in the test of pancake coil model arising form the deficiency of insulation data. Therefore, this paper describes the results of an experimental study on the ac breakdown voltage($V_{B}$) properties of $LN_2$ and Air under the electrode of simulated HTS pancake coil. The ac breakdown voltage of $GN_{2}$ have been measured by pancake coil-pancake coil gaps over the temperature range of 293 K to 77 K.

  • PDF

액체 질소중 교류방전 진전에 따른 방사전자파의 주파수 스펙트럼 특성 (The Characteristics of Frequency Spectrum of Radiated Electromagnetic Waves with AC Discharge Progress in Liquid Nitrogen)

  • 박광서;윤대희;이상훈;이현동;김충년;최병주;김기채;이광식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권3호
    • /
    • pp.123-129
    • /
    • 2003
  • In this paper, a relationship between AC discharge progress and the radiated electromagnetic waves was investigated by measuring electromagnetic waves using a biconical antenna and a spectrum analyzer. The frequency spectrum of the radiated electromagnetic waves were measured at the atmospheric pressure in liquid nitrogen($LN_2$) during partial discharges progressed by AC high voltage in nonuniform electric field. Front the results of this study, a new method was introduced for measurement and analysis of the radiated electromagnetic waves with discharge progress in $LN_2$ Besides. according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting partial discharge and estimating discharge progress could be possible. It is considered that these results obtained from this investigation may be used as fundamental data for diagnosis and prediction of electric insulations about superconducting and cryogenic power equipments.

액체질소 분사 안정화를 통한 극저온가공 품질 향상 (Improvement of the Quality of Cryogenic Machining by Stabilization of Liquid Nitrogen Jet Pressure)

  • 강명구;민병권;김태곤;이석우
    • 한국정밀공학회지
    • /
    • 제34권4호
    • /
    • pp.247-251
    • /
    • 2017
  • Titanium alloy has been widely used in the aerospace industry because of its high strength and good corrosion resistance. During cutting, the low thermal conductivity and high chemical reactivity of titanium generate a high cutting temperature and accelerates tool wear. To improve cutting tool life, cryogenic machining by using a liquid nitrogen (LN2) jet is suggested. In cryogenic jet cooling, evaporation of LN2 in the tank and transfer tube could cause pressure fluctuation and change the cooling rate. In this work, cooling uniformity is investigated in terms of liquid nitrogen jet pressure in cryogenic jet cooling during titanium alloy turning. Fluctuation of jet spraying pressure causes tool temperature to fluctuate. It is possible to suppress the fluctuation of the jet pressure and improve cooling by using a phase separator. Measuring tool temperature shows that consistent LN2 jet pressure improves cryogenic cooling uniformity.

Quench에 의해 유도되는 액체 $N_2$의 절연파괴 특성 (Breakdown Characteristics of Liquid Nitrogen Induced by Quench)

  • 김영석;정종만;곽민환;정순용;김상현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권1호
    • /
    • pp.23-28
    • /
    • 1999
  • Electrical breakdown characteristics of liquid nitrogen($LN_2$) used as both coolant and insulator for high $T_c$ superconductor system are very important. This paper presents dynamic breakdown characteristics fo $LN_2$ by quench phenomena of thermal bubble under high electric field. Experimental results revealed dynamic breakdown voltage fell down drastically compared with the static breakdown voltage without the quench. Because of increasing heat power, bubble size becomes big and breakdown voltage decreases. The breakdown voltage mechanism of $LN_2$ depends on thermal bubble effect. In the Electrode arrangement, electrical breakdown voltage of horizontal arrangement appears lower than that of vertical arrangement. Also, we observed the behavior of thermal bubbles in $LN_2$ which were generated after quench using camera.

  • PDF

HTS pancake 코일을 모의한 전극계에서의 전기절연 특성 (Electrical insulation characteristics with simulated electrode system of HTS)

  • 정종만;백승명;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.58-63
    • /
    • 2002
  • For the experiment the four types of spacer were distinguished by arrangement. The flashover characteristic on each types of spacer was investigated and the flashover phenomena were observed to understand breakdown mechanism in liquid nitrogen($LN_{2}$). The spacer should be placed interior coil as an insulator, a cooling channel and s supporter of structures. The simulated electrode used in the experiment was made from five turns of HTS tape. Experimental results revealed that multi-layer and barrier effects did work well in Air but did not in $LN_{2}$. These result suggested that the flashover in LN2 caused by the bubbles due to partial discharge at micro gap, g. The flashover characteristics decreased to 70% when g is 0.2 mm. The degradation was improved by even treatment on surface of coil electrode.

  • PDF

액체로켓엔진의 연소가스와 액체질소 혼합에 의한 연소 가스 냉각 특성에 관한 연구 (Study on Cooling Characteristics of Mixed Gases with Hot Gas of Liquid Rocket Engine and Injected Liquid Nitrogen)

  • 전준수;유이상;김중일;김재호;고영성
    • 대한기계학회논문집B
    • /
    • 제36권10호
    • /
    • pp.1001-1009
    • /
    • 2012
  • 본 연구에서는 액체산소와 케로신을 추진제로 사용하는 액체로켓엔진의 연소 가스에 액체질소를 분사하여 연소 가스의 냉각 특성을 알아보고자 하였다. 일반적인 액체로켓엔진의 연소실 후단에 액체질소 분사기와 혼합용 연소실을 추가적으로 장착하였고, 혼합용 연소실 후단에 노즐을 연결하여 전체적인 시스템을 구성하였다. 연소실험은 안전을 고려하여 점화실험부터 순차적으로 수행하였으며, 최종적으로 20초 연소실험을 수행하였다. 그 결과 기존의 액체로켓엔진에 액체질소를 분사함으로써, 연소 가스의 온도를 저하시킬 수 있음을 확인하였다.

Study on the Dielectric Characteristics of Gaseous Nitrogen for Designing a High Voltage Superconducting Fault Current Limiter

  • Heo, Jeong-Il;Hong, Jong-Gi;Nam, Seok-Ho;Kang, Hyoung-Ku
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.28-31
    • /
    • 2012
  • The study on the dielectric characteristics of gaseous insulation medium is important for designing current leads of superconducting machines using a sub-cooled liquid nitrogen ($LN_2$) cooling method. In a sub-cooled $LN_2$ cooling system, the temperature of gaseous insulation medium surrounding current leads varies from the temperature of coolant to 300 K according to the displacement between the electrode system and the surface of sub-cooled $LN_2$. In this paper, AC withstand voltage experiments on gaseous nitrogen according to temperature are conducted. Also, AC withstand voltage experiments on gaseous nitrogen according to pressure, size of electrode, and gap length between two electrodes are performed. It is found that there is a functional relation between the electrical breakdown voltage and the field utilization factor (${\xi}$). As a result, the empirical formula for estimating an electrical breakdown voltage is deduced by adopting the concept of field utilization factors. It is expected that the experimental results presented in this paper are helpful to design current leads for a high voltage superconducting apparatus such as a superconducting fault current limiter (SFCL) using a sub-cooled $LN_2$ cooling system.

Lubrication Effect of Liquid Nitrogen in Cryogenic Machining Friction on the Tool-chip Interface

  • Jun Seong-Chan
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.936-946
    • /
    • 2005
  • The liquid nitrogen as an environmentally safe coolant has been widely recognized in cryo­genic machining, its function as a lubricant is plausible due to its chemical inertness, physical volatility and low viscosity. Since a reduced friction is a direct witness of the lubrication effect from a tribological viewpoint, this paper presents an evaluation of the apparent friction coefficient on the tool-chip interface in cryogenic cutting operations to prove and characterize the lubricity of LN2 in cryogenic machining. The cryogenic cutting technology used in this study is based on a cooling approach and liquid nitrogen delivery system which are intended to apply liquid nitrogen in well-controlled fine jets to selectively localized cutting zones and to penetrate liquid nitrogen to the tool-chip interface. It has been found that the apparent friction coefficient can be significantly reduced in cryogenic machining, depending on the approach of liquid nitrogen delivery.