• 제목/요약/키워드: $K^+$ current

검색결과 42,993건 처리시간 0.074초

조동의 전류효율에 미치는 직류 및 가변전류의 영향 (The Effect of Direct and Variable Current on Current Efficiency of Copper Anode)

  • 안승천;이상문;김용환;정원섭
    • 한국표면공학회지
    • /
    • 제39권5호
    • /
    • pp.223-228
    • /
    • 2006
  • The current efficiency of copper anode containing impurities in copper sulfate solution for electrorefining was studied at various current type such as direct current, variable current and periodic reverse current. The passivity behavior was investigated by galvanostatic technique. The results obtained were that current efficiency of variable current was higher than those of direct current and periodic reverse current. The increased current efficiency could be explained by the formation of slime structure with lower average resistance due to variable current. The frequency of various factors in variable current condition has a greatest effect on current efficiency. It appeared that frequency increased current efficiency when increased from 1 to 4, but further increases did not have an effect.

Flyback Converter를 이용한 Active Current Bias 제어 (the Active Current Bias Control using Flyback Converter)

  • 황선남;임성규;이준영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.84-87
    • /
    • 2006
  • 본 연구는 Current Mirror에 있어서 Active Current Bias에 관하여 기술하였다. Current mirror에서 Active Current Bias를 걸어주는 보편적인 방법은 Current Bias단에 저항을 연결하여 저항값을 조절함으로 해서 Current를 제어하는 방법을 사용한다. Reference 전류를 제어하는데 있어 새로이 제안하는 것은 Flyback Converter를 이용하여 Acitve Current Bias를 제어 하려 한다. 트랜지스터를 이용하여 Current Mirror Circuit를 구성하고 Current Bias 측에 Flyback Converter Circuit을 연결한다. Flyback Converter의 PWM의 Duty Ratio를 조절함으로 해서 전류를 제어하는 특징을 이용하여 Active Current Bias를 제어한다.

  • PDF

과전류 인가 시 고온초전도 선재의 ?치 특성 (Quench characteristics of HTS tapes applied over-current)

  • 임성우;최용선;황시돌;한병성
    • Progress in Superconductivity
    • /
    • 제4권2호
    • /
    • pp.184-188
    • /
    • 2003
  • Voltage-current characteristics of High Temperature Superconductor(HTS) tapes after applying the current beyond their critical current was investigated. When over-current is applied, the current begins to flow through the metal sheath instead of superconductor. The HTS tapes quenched were analyzed using V-I curve with various magnitudes of current. Two kinds of tapes were compared with each other to examine the influence of critical current on quench development. As a result, it was found that the resistance of superconductors and joule heat due to the over-current affect current distribution in HTS tapes. Critical current of HTS tapes was considered as a main factor deciding over-current characteristics.

  • PDF

A Fast Response Integrated Current-Sensing Circuit for Peak-Current-Mode Buck Regulator

  • Ha, Jung-Woo;Park, Byeong-Ha;Kong, Bai-Sun;Chun, Jung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권6호
    • /
    • pp.810-817
    • /
    • 2014
  • An on-chip current sensor with fast response time for the peak-current-mode buck regulator is proposed. The initial operating points of the peak current sensor are determined in advance by the valley current level, which is sensed by a valley current sensor. As a result, the proposed current sensor achieves a fast response time of less than 20 ns, and a sensing accuracy of over 90%. Applying the proposed current sensor, the peak-current-mode buck regulator for the mobile application is realized with an operating frequency of 2 MHz, an output voltage of 0.8 V, a maximum load current of 500 mA, and a peak efficiency of over 83%.

예측 전류를 적용한 3 션트 PWM 인버터의 전류 복원 기법 (three phase current reconstruction method applying predictive current in three shunt sensing PWM inverter)

  • 홍성우;김도윤;원일권;김영렬;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.99-100
    • /
    • 2016
  • In a AC motor used by three phase inverter, the phase current must be measured to control instantaneous torque. It is expensive to use current sensor for measuring current in low cost motor. So, shunt resistor is used to measure current. But, the method sensing the phase current using shunt resistor cannot perform the vector control in high speed because of the area that impossible to restore three phase current. In this paper, predictive current is proposed for reconstructing the current in the impossible current sensing area that reduce the current ripple in TSSI(Three shunt sensing inverter) for PMSM.

  • PDF

기동방식을 고려한 DC급전계통 보호알고리즘 (A Protection Algorithm for DC Railway Systems Considering Train Starting)

  • 권영진;최동민;강상희;한문섭;이재경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.307-309
    • /
    • 2004
  • A DC railway system has low feeder voltage, The remote fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the train starting current. The train starting current increases step by step but the fault current increases all at once. So the type of $\bigtriangleup I\;relay(50F)$ was developed using the different characteristics between the load starting current and the fault current. As for the train starting current, the time constant of train current at each step is much smaller than that of the fault current. To detect faults in U railway systems, an algorithm that is independent of train starting current. This algorithm use the time constant calculated by the method of least squares is presented in this paper.

  • PDF

DC철도 급전계통 보호시스템 구성 (A Protection Scheme for DC Railway Systems)

  • 권영진;강상희;오광해;이재경;이명희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.91-94
    • /
    • 2003
  • A DC railway system has low feeder voltage, The fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases all at once. So the type of ${\Delta}I$ relay(50F) was developed using the different characteristics between the load starting current and the fault current. As for the load starting current, the time constant of load current at each step is much smaller than that of the fault current. First, to detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares is presented in this paper. Secondly, to compose a protection scheme for DC railway systems is presented in this paper.

  • PDF

고온초전도 전류제한기의 초기사고전류 제한시점 분석 (Analysis of the Initial Fault Current Limiting Point of the SFCLs)

  • 박충렬;두호익;두승규;김용진;김민주;조용선;최효상;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.292-292
    • /
    • 2008
  • The superconducting fault current limiter(SFCL) can be used to limit fault current level in electrical transmission line and power system. Up to now, there are several kinds of SFCL that have proposed and it is expects that they will be applied to appropriated position considering their own properties; initial fault current limiting instant and the current limiting characteristics. In this paper, we investigated the initial fault current limiting instant and the amplitude of initial fault current in the resistive type, the flux-lock type, the flux-coupling type and the transformer type SFCL. Experiment results show that the initial fault current limiting instant and the amplitude of initial fault current of the SFCLs are dependant on the ratio of inductance of primary and secondary coils.

  • PDF

A New Overlap Current Restraining Method for Current-source Rectifier

  • Qin, Haihong;Liu, Qing;Zhang, Ying;Zhang, Xin;Wang, Dan
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.615-626
    • /
    • 2018
  • To ensure a DC current path and avoid large voltage overshoot of the DC-link inductor, alternating PWM pulses in the current-source rectifier should be supplemented by overlap time, which generates an overlap current and causes input current distortion. In this study, the influence of overlap time is illustrated by comparing the AC-side current before and after overlap time is added. The overlap current distribution caused by overlap time is discussed under different modulation carriers, including triangle carrier, positive-going carrier, and negative-going carrier. The quantitative relationship between the extra harmonics of the AC-side current and overlap time is based on the Fourier analysis. Based on the commutation analysis, a new carrier modulation scheme that can restrain overlap current is proposed. A 3 kW prototype is established to verify the effectiveness of the influence of overlap time and the proposed restraining modulation scheme.

The effect of non-uniform current distribution on transport current loss in stacked high-Tc superconductor tapes

  • Choi, Se-Yong;Nah, Wan-Soo;Joo, Jin-Ho;Ryu, Kyung-Woo;Lee, Byoung-Seob;Yoon, Jang-Hee;Ok, Jung-Woo;Park, Jin-Yong;Won, Mi-Sook
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.16-19
    • /
    • 2012
  • The influence of current distribution on the transport current loss in vertically stacked high-$T_c$ superconductor (HTS) tapes was evaluated. AC loss was analyzed as a function of current distribution by introducing a current distribution parameter through a numerical method (finite element analysis). AC loss under non-uniform current distribution is always higher than that for a uniformly distributed transport current in a conductor. Although the effect of non-uniformity is relatively insignificant in low transport current, AC loss increases substantially in high transport current regions as non-uniformity is enlarged. The results verify that non-uniform current distribution causes extra loss by examining the cross-sectional view of current densities in stacked conductor.