• Title/Summary/Keyword: $Implantium^{(R)}$ implant

Search Result 10, Processing Time 0.03 seconds

The analysis of short term success rate and healing patterns of $Implantium^{(R)}$ Implant (($Implantium^{(R)}$) implant의 단기 생존율 및 치유 양상에 대한 연구)

  • Chae, Gyung-Joon;Chung, Sung-Min;Jung, Ui-Won;Cho, Kyoo-Sung;Chai, Jung-Kyu;Kim, Chong-Kwan;Choi, Seong-Ho;Kim, Chang-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.683-691
    • /
    • 2006
  • This study is an analysis of distribution of patients who installed Implantium implant in Yonsei University Dental Hospital and types of implant site for about 1 years recall check and success rate. 164 implants were installed to 52 patients in this study. It shows the conclusion below. 1. Patients at the age of 40s and 50s were 65% of all implant cases and average number of implant was 4 (man), and 2.7 (woman). 75 implants were operated on maxilla and 89 were mandible. 19 implants on anterior region and 145 implants on posterior region. 2. Most distribution of bone qaulity for implant site was type III(37.2%) and bone quantity was type C(61. 7%) 3. The majority of implants were those of 10, 12mm in length (85%) and regular diameter in width (48.8%). 4. 30 implants were installed with the advanced technique-GER, window opemng, osteotome technique. 5. Two implants were removed before prosthodontic treatment due to the osseointegraton failure. The success rate was 98.8% in 15.2 months follow up period and the marginal bone loss was 0.28mm. The results provided us with basic data on patient type, implant distribution, bone condition, and survival rate. Within the limit of present study, It was concluded that Implantium implant could be used satisfactorily in various clinical situations.

Comparison of Clinical Initial Stability of Hydroxy-apatite Coated Implant and Sandblasted, Large-grit and Acid-etched Implant (수산화인회석 코팅 임플란트와 Sandblasted, Large-grit and Acid-etched Implant의 임상적 초기 안정성 비교)

  • Lim, Hyoung-Sup;Kim, Su-Gwan;Oh, Ji-Su
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.2
    • /
    • pp.112-116
    • /
    • 2012
  • Purpose: This study attempts to compare the stability of hydroxy-apatite coating implant with that of sandblasted, large-grit and acid-etched surface implant at an early state of installation. Methods: 35 implants were installed in 18 patients, who had visited hospital for implant installation. The early stability at operation, 6 weeks and 12 weeks after operation using Osstell$^{TM}$ mentor (Integration Diagnostics, Savedalen, Sweden) and Periotest$^{(R)}$ (Siemens AG, Benssheim, Germany) were measured, and subsequently analyzed statistically. Results: OsstellTM mentor value of hydroxy-apatite coated implant (HAPTITE) was measured as $70.14{\pm}9.07$ at the stage of installation, $76.98{\pm}5.25$ at 6 weeks and $80.28{\pm}4.23$ at 12 weeks after installation. A statistically significant increase in measurement value was observed after 6 weeks and 12 weeks than when implants were placed. In case of IMPLANTIUM (DENTIUM Co. Ltd., Seoul, Korea), the measurement value was $74.68{\pm}7.42$ at installation, $79.03{\pm}4.39$ at 6 weeks and $80.59{\pm}3.59$ at 12 weeks after installation. In addition, a statistically significant increase in the value was observed when comparative analysis of the value at after installation and 12 weeks after installation was carried out. However, no significant difference between HAPTITE and IMPLANTIUM was observed. The average measurement value of periotest$^{(R)}$ was $-1.94{\pm}3.90$ at installation of HAPTITE, $-4.03{\pm}1.48$ at 6 weeks and $-5.00{\pm}1.71$ at 12 weeks after installation. Moreover, whilst comparing the value at after installation and 12 weeks after installation, statistically significant decrease in the value was observed. In case of IMPLANTIUM, the average measurement value was measured as $-4.25{\pm}1.76$ at installation, $-4.76{\pm}0.97$ at 6 weeks and $-5.18{\pm}0.91$ at 12 weeks after installation and no statistically significant difference was observed. Furthermore, no statistically significant difference was observed between HAPTITE and IMPLANTIUM. Conclusion: In this study, both the implants demonstrated favorable early stability at the time of measurement using Osstell$^{TM}$ mentor and Periotest$^{(R)}$. Moreover, based on the observed results, both HAPTITE and IMPLANTIUM are considered as potent to exhibit clinically stable and prognostic results.

Bone-to-Implant Contact according to the Surface Roughness of the Implants (임플란트의 표면조도가 골융합에 미치는 영향)

  • Choi, Kwi-Hyun;Herr, Yeek;Lee, Man-Sub;Kwon, Young-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.4
    • /
    • pp.717-728
    • /
    • 2003
  • This study was performed to evaluate the difference of the bone-to-implant contact according to the surface roughness of the implants. Two beagles were used in the experiment. Extraction of the all premolars was performed in the mandible. In 3 months of healing, screw-shaped pure titanium machined surface implants (Implantium(R), Dentium Co. Korea), implants blasted with 45${\mu}m$ $TiO_2$ particles, (Implantium(R), Dentium Co. Korea) and implants blasted with 100${\mu}m$ $TiO_2$ particles (Implantium(R), Dentium Co. Korea) in diameter 3.4mm and length 6mm were installed in the edentulous mandible. Each dog was sacrificed at 4, 12 weeks after placement and then nondecalcified specimens were prepared for histologic analysis. The results of this study were as follows. 1. At 4 , 12 weeks after the surgery, bone-to-implant contact in the surface blasted with $TiO_2$ particles was higher than that in the pure titanium machined surface respectively. 2. Osseointegration in the surface blasted with 45${\mu}m$ $TiO_2$ particles was more increased than that in the surface blasted with 100${\mu}m$ $TiO_2$ particles. 3. Bone-to-implant contact was increased with time independent of surface roughness. 4. Bone formation was in the outfolded area more than inside the threads independent of surface roughness. From the above results, we were able t o find the most bone-to-implant contact in 45${\mu}m$ $TiO_2$ blasted implant.

Retrospective study of the $Implantium^{(R)}$ implant with a SLA surface and internal connection with microthreads (SLA 표면 처리와 미세나사선을 가진 내측 연결형의 국산 임플란트에 대한 후향적 연구)

  • Doh, Re-Mee;Moon, Hong-Suk;Shim, Jun-Sung;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.136-147
    • /
    • 2009
  • Statement of problem: Since the introduction of the concept of osseointegration in dental implants, high long-term success rates have been achieved. Though the use of dental implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. Purpose: The aim of this retrospective study was to provide long-term data on the $Implantium^{(R)}$ implant, which features a sandblasted and acid-etched surface and internal connection with microthreads. Material and methods: 106 $Implantium^{(R)}$ implants placed in 38 patients at Yonsei University Hospital were examined to determine the effect of various factors on implant success and marginal bone loss, through clinical and radiographic results during a 6 to 30 month period. Results: 1. Out of a total of 106 implants placed in 38 patients, one fixture was lost, resulting in a 99.1% cumulative survival rate. 2. Among the 96 implants which were observed throughout the study period, the survival rates were 97.0% in the maxilla and 100% in the mandible. The survival rate in the posterior regions was 98.9% and 100% in the anterior regions. 3. The mean bone loss during the first year after prosthesis placement was 0.17 mm, while the mean annual bone loss after the first year was 0.04 mm, which was statistically less than during the first year(P<.05). 4. There was no significant difference in marginal bone loss according to age during the first year(P>.05), but after the first year, the mean annual bone loss in patients above 50 years was significantly greater(P<.05) compared with patients under 50 years. 5. No significant difference in marginal bone loss was found according to the following factors: gender, jaw, location in the arch, type of implant(submerged or non-submerged), presence of bone grafts, type of prostheses, and type of opposing dentition(P<.05). Conclusion: Based on these results, the sole factor influencing marginal bone loss was age, while factors such as gender, jaw, location in the arch, type of implant, presence of bone grafts, type of prostheses and type of opposing dentition had no significant effect on bone loss. In the present study, the success rate of the $Implantium^{(R)}$ implant with a SLA surface and internal connection with microthreads was satisfactory up to a maximum 30 month period, and the marginal bone loss was in accord with the success criteria of dental implants.

Retrospective Study of Sandblasted, Large-grit and Acid-etched Implant (Sandblasted, Large-grit and Acid-etched Implant에 대한 후향적 임상 연구)

  • Jo, Ji-Ho;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su;Park, Jin-Ju;Jung, Jong-Won;Yoon, Dae-Woong;Yang, Seong-Su;Jeong, Mi-Ae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.4
    • /
    • pp.352-358
    • /
    • 2011
  • Purpose: This study evaluated the prognosis and survival rate of SLA (Sandblasted, Large-grit and Acid-etched) implants and it also evaluated the prosthodontic complications and the associated factors. Methods: Twenty seven patients (14 men and 13 women, mean age: 54.9) who visited Chosun University Hospital Implant Center with the chief desire for placement of an implant in an edentulous area from March, 2008 to December 2008 and who received placement of a SLA implant ($Implantium^{(R)}$, Dentium Co., Korea) were selected for this study. Results: The average follow-up period was 15 months and the study was based on the treatment records, radiographs and clinical examinations. A total of 69 implant cases were retrospectively assessed for the width and length of the implant, the primary and secondary stability, the combined surgery, the employed bone graft material and barrier membrane, the status of the opposing tooth, implant failure and the prosthetic complications. During the follow-up period (average: 15 months), the accumulative survival rate of the 69 implants in 27 patients was 100%. Complications such as infection, sinusitis and fixture exposure after surgery were seen for 5 implants in 4 patients. Complications such as screw loosening, contact loosening and peri-implant gingivitis after prosthodontic treatment occurred in 7 cases (10.14%). Conclusion: This study reports placement of SLA implants may cause various complications, yet the final accumulative survival rate was 100%. The SLA implant ($Implantium^{(R)}$) has an excellent clinical survival rate and outcome.

FIT OF FIXTURE/ABUTMENT/SCREW INTERFACES OF INTERNAL CONNECTION IMPLANT SYSTEM

  • Kim, Jin-Sup;Kim, Hee-Jung;Chung, Chae-Heon;Baek, Dae-Hwa
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.338-351
    • /
    • 2005
  • Statement of problem. Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. Purpose. This study is to evaluate the machining accuracy and consistency of the implant fixture/ abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) Materials and methods. The implant systems selected in this study were internal connection type implants from AVANA(Osstem^{\circledR}), Bioplant(Cowell-Medi^{\circledR}), Dio(DIO^{\circledR}), Neoplant(Neobiotech 􀋓), Implantium(Dentium􀋓)systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and conclusions. 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.

The influence of implant diameter, length and design changes on implant stability quotient (ISQ) value in artificial bone (임플란트의 직경, 길이 및 디자인변화가 임플란트 안정성지수(ISQ)에 미치는 영향)

  • Lee, Jeong-Yol;Lee, Won-Chang;Kim, Min-Soo;Kim, Jong-Eun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.292-298
    • /
    • 2012
  • Purpose: The purpose of this study is to ascertain the stability of the implant by comparing the effects of the change of implant diameter, length and design on implant stability quotient. Materials and methods: To remove the variable due to the difference of bone quality, the uniform density (0.48 g/$cm^3$) Polyuretane foam blocks (Sawbones$^{(R)}$, Pacific Research Laboratories Inc, Vashon, Washington) were used. Implants (Implantium$^{(R)}$, Dentium, Seoul, Korea) were placed with varying diameters (${\phi}3.8$, ${\phi}4.3$ and ${\phi}4.8$) and length (8 mm, 10 mm and 12 mm), to assess the effect on implant stability index (ISQ). Also the influence of the design of the submerged and the non-submerged (SimplelineII$^{(R)}$, Dentium, Seoul, Korea) on ISQ was evaluated. To exclude the influence of insertion torque, a total of 60 implants (n = 10) were placed with same torque to 35 N. Using Osstell$^{TM}$ mentor (Integration Diagnostic AB, Sweden) ISQ values were recorded after measuring the resonant frequency, one-way ANOVA and Tukey HSD test results were analyzed. (${\alpha}$=0.05). Results: 1. The change of the diameter of the implant did not affect the ISQ (P>.05), but the increase of implant length increased the ISQ(P<.001). 2. The change in implant design were correlated with the ISQ, and the ISQ of submerged design was significantly higher than that of the non-submerged design(P<.05). Conclusion: In order to increase implant stability, the longer implant is better to be selected, and on the same length of implant, submerged design is thought to be able to get a higher ISQ than the non-submerged.

Retrospective studies of dental implant placement at each intraoral site and situation (임플란트 식립 유형에 따른 후향적 연구)

  • Hong, Ji-Youn;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chae, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.805-824
    • /
    • 2007
  • Purpose: Developments in micro/macrostructures of implants and surgical techniques brought out stable outcomes of implant dentistry. The aim of this study was to evaluate the distributions of implant patients, the types of implanted sites, and the success or survival rates of various implant systems and to analyze the implant placement done at each specificintraoral site and situation. Materials and Methods: The data of dental implantations collected between 1992 and 2006 at the Department of Periodontology in 00000 University Hospital were analyzed. Results: 1. Largest part of the patients were at the age of 40s and 50s in bothgender who lost their teeth mostly by periodontaldiseases and caries at the posterior intraoral sites as major ones. Bone densities of type II(mandible) and III(maxilla) were likely to be seen with quantity of type B. Lengths of the implants between 10 and 15 mm and wide platform took the largest part. 2. Survival rates of $Implantium^{(R)}(98.8%)$, $Xive^{(R)}(100%)$ and ITI $TE^{(R)}(100%)$ were high when $Frialit-2^{(R)}$ showed 82%(poor bone density area) or 87.2%(combined with additional therapy). $IMZ^{(R)}$ had lowest cumulative survival(67.5%) and success rate(49.4%) amongst all. 3. Replacement with 2 wide or 3 regular platforms showed no significant differences in survival rate and marginal bone loss atmandibular posterior area. In single restoration of mandibular second molar, 5-year success rate of machined surface $Br{\aa}nemark^{(R)}(70.37%)$ was lower than that of rough surface $ITI^{(R)}$ SLA(100%). 4. Replacement of single tooth in anterior area showed high survival rate of 94.5%. 5. The success rates of $Br{\aa}nemark$ Ti-Unite and ITI SLA at posterior maxilla with poor bone density both showed stable outcomes. 6. 10-year cumulative survival rate of implants with maxillary sinus augmentation by lateral window approach appeared to be 96.60%. Low survival rate(75%) was shown when there were more than two complications combined. Height of grafted bone remained stable above the implant apex. Conclusions : Rough surfaced implants showed stable outcomes in most of the situation including poor bone density and additional therapy combined.

Comparision of Osseointegration Depending on Surface Treatment (임플란트 표면처리에 따른 골융합의 차이)

  • Hwang, Ha-Jun;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.4
    • /
    • pp.699-709
    • /
    • 2004
  • The present study was performed to evaluate histomorphological difference in various surface-treated implants in beagle. Implants($Implantium^{(R)}$, Dentium Co. Korea) with pure titanium machined surface, acid treated surface, and $Al_2O_3(50{\sim}100\;{\mu}m)$blasted with acid treated surface were used in this study. All mandibular premolars of $1.5{\sim}2$ year old male beagle dogs were extracted. At 3 months after extraction, the implants(${\Phi}$ 4mm, l 6mm) were installed. The beagle were sacrificed at 1, 3 months after installation and then tissues including implants were prepared for non-decalcified specimens. These specimens were analyzed comparatively under light microscope. The results of this study were as follow 1. Higher rate of osseointegration were showed in the $Al_2O_3(50{\sim}100\;{\mu}m)$blasted with acid-treated surface. 2. Increased osseointegration were showed in the $Al_2O_3(50{\sim}100\;{\mu}m)$blasted with acidtreated surface with time. 3. Higher maturation of integration were showed in the $Al_2O_3(50{\sim}100\;{\mu}m)$blasted with acid-treated surface. In conclusion, surface treatment of $Al_2O_3blasted$ with acid might be considered to shorten healing time and improve success rate as increasing contact of implant and bone.