• Title/Summary/Keyword: $I_c$ measurement

Search Result 716, Processing Time 0.03 seconds

An Optimal Algorithm of Harmonic State Estimation using Immune Algorithm on Power System (IA를 이용한 전력시스템 고조파 상태 추정 최적 알고리즘)

  • Park, I.P.;Wang, Y.P.;Chung, H.H.;Park, H.C.;Ahn, B.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.92-94
    • /
    • 2003
  • The design of a measurement system to perform Harmonic State Estimation(HSE) is a very complex problem. In particular, the number of available harmonic instruments (Continuous Harmonic Analysis in Real Time : CHART) is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents an optimal algorithm of HSE which is based on an optimal placement of measurement points using Immune Algorithm (IAs). This HSE has been applied to power system for the validation of an optimal algorithm of HSE. The study results have indicated an economical and effective method for optimal placement of measurement points using IAs in the HSE.

  • PDF

SiC(3C)/Si Photodetector (SiC(3C)/Si 수광소자)

  • 박국상;남기석;김정윤
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.2
    • /
    • pp.212-216
    • /
    • 1999
  • SiC(3C) photodiodes (PDs) were fabricated on p-type Si(111) substrates using chemical vapor deposition (CVD) technique by pyrolyzing tetramethylsilane (TMS) with $H_{2}$ carrier gas. Electrical properties of SiC(3C) were investigated by Hall measurement and current-voltage (I-V) characteristics. SiC(3C) layers exhibited n-type conductivity. Ohmic contact was formed by thermal evaporation Al metal through a shadow-mask. The optical gain $(G_{op})$ of the SiC(3C)/Si PD was measured as a function of the incident wavelength. For the analysis of the photovoltaic detection of the Sic(3C) n/p PD, the spectral response (SR) has calculated by using the electrical parameters of the SiC(3C) layer and the geometric structure of the PD. The peak response calculated for properly chosen parameters was about 0.75 near 550 nm. We expect a good photoresponse in the SiC(3C) heterostructure for the wavelength range of 400~600 nm. The SiC(3C) photodiode can detect blue and near ultraviolet (UV) radiation.

  • PDF

QUALITY IMPROVEMENT OF VEHICLE DRIFT USING STATISTICAL SIX SIGMA TOOLS

  • PARK T. W.;SOHN H. S.
    • International Journal of Automotive Technology
    • /
    • v.6 no.6
    • /
    • pp.625-633
    • /
    • 2005
  • Vehicle drift was reduced using statistical six sigma tools. The study was performed through four steps: M (measure), A (analyze), I (improve), and C (control). Step M measured the main factors which were derived from a fishbone diagram. The measurement system capabilities were analyzed and improved before measurement. Step A analyzed critical problems by examining the process capability and control chart derived from the measured values. Step I analyzed the influence of the main factors on vehicle drift using DOE (design of experiment) to derive the CTQ (critical to quality). The tire conicity and toe angle difference proved to be CTQ. This information enabled the manufacturing process related with the CTQ to be improved. The respective toe angle tolerance for the adjustment process was obtained using the Monte Carlo simulation. Step C verified and controlled the improved results through hypothesis testing and Monte Carlo simulation.

Effective professional intraoral tooth brushing instruction using the modified plaque score: a randomized clinical trial

  • Park, Se-Ho;Cho, Sung-Hee;Han, Ji-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.1
    • /
    • pp.22-33
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the efficacy of the modified plaque score (MPS) for assessing the oral hygiene status of periodontitis patients. Methods: A total of 116 patients were included in this study. After evaluation of the $L{\ddot{o}}e$ and Silness gingival index (GI), Silness and $L{\ddot{o}}e$ plaque index (PlI), O'Leary plaque control record (PCR), and MPS, patients were randomly assigned to either a conventional tooth brushing instruction (C-TBI) group (n=56) or a professional intraoral tooth brushing instruction (P-TBI) group (n=60). The MPS and clinical parameters were re-evaluated after scaling and a series of root planing. The convergent validity of MPS with the PlI and PCR was assessed. The measurement time for MPS and PCR was compared according to the proficiency of the examiner. Results: After root planing, the GI, PlI, PCR, and MPS improved from their respective baseline values in both groups. Three different plaque indices including the MPS, showed significant differences between the C-TBI group and the P-TBI group after root planing. The MPS showed significant concurrence with the PCR and PlI. The mean time for PCR measurement was $2.76{\pm}0.71$ times longer than that for MPS measurement after 2 weeks of training. Conclusions: MPS seems to be a practical plaque scoring system compared with the PlI and PCR. These findings suggest that repetitive plaque control combined with an easily applicable plaque index (MPS) may facilitate more effective oral hygiene education and improved periodontal health.

The annealing effects of Au/Te/Au n-GaAs structure (Au/Te/Au/ n-GaAs구조의 열처리 효과)

  • 정성훈;송복식;문동찬;김선태
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1013-1018
    • /
    • 1996
  • The annealing effects of Au/Te/Au/n-GaAs structure was investigated by using x-ray diffraction, scanning electron microscope, the specific contact resistance and I-V measurement. Increasing the annealing temperature, the intensity of Au-Ga peak by X-ray diffraction was increased. The Ga$\_$2/Te$\_$3/peak got evident for the samples annealed at 400.deg. C and GaAs peak by recrystallization appeared for the samples annealed at 500.deg. C. The variation from the schottky to low resistance contact was confirmed by I-V curve. The lowest value of the specific contact resistance of the samples annealed at 500.deg. C was 3.8*10$\^$-5/.ohm.-cm$\^$2/ but the value increased above 600.deg. C.

  • PDF

150 nm Pitch Measurement using Metrological AFM (길이 소급성을 갖는 AFM을 이용한 150nm 피치 측정)

  • ;I. Misumi;S. Gonda;T. Kurosawa
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.264-267
    • /
    • 2003
  • Pitch measurements of 150 nm pitch one-dimensional grating standards were carried out using an contact mode atomic force microscopy(C-AFM) with a high resolution three-axis laser interferometer. It was called as 'Nano-metrological AFM' In Nano-metrological AFM, Three laser interferometers were aligned well to the end of AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$-stablilzed He-Ne laser at a wavelength of 633 nm. So, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM has a traceability to the length standard directly. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement(GUM). The Primary source of uncertainty in the pitch-measurements was derived from repeatability of pitch-measurement, and its value was approx 0.186 nm. Expanded uncertainty(k=2) of less than 5.23 nm was obtained. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

  • PDF

An Combustion Diagnosis Using Optical Measurement in D. I Diesel Engine with Dual Fuel Stratified Injection System (이종연료 층상분사를 적용한 디젤엔진에서 광 계측을 이용한 연소해석)

  • An, H.C.;Kang, B.M.;Yeom, J.K.;Chung, S.S.;Ha, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.7 no.3
    • /
    • pp.31-37
    • /
    • 2002
  • In previous study, diesel-methanol stratified injection system is manufactured and applied to a D.I. diesel engine in order to realize combustion improvement using methanol, which is oxygenated fuel with large latent heat. We know that NOx and soot is reduced by stratified injection of diesel fuel-methanol. Therefore, in the present study, combustion diagnosis using optical measurement is tried to make clear effect of methanol on simultaneous reduction of NOx and soot. Two-color method is used to measure flame temperature and KL value, which is approximately proportional to the soot consentration along the optical path. Laser induced scattering method was used to measure distribution of soot at two dimensional area. Also, it is compared exhaust characteristics of NOx and soot with results of optical measurement.

  • PDF

INSTRUMENTATION AND CONTROL STRATEGIES FOR AN INTEGRAL PRESSURIZED WATER REACTOR

  • UPADHYAYA, BELLE R.;LISH, MATTHEW R.;HINES, J. WESLEY;TARVER, RYAN A.
    • Nuclear Engineering and Technology
    • /
    • v.47 no.2
    • /
    • pp.148-156
    • /
    • 2015
  • Several vendors have recently been actively pursuing the development of integral pressurized water reactors (iPWRs) that range in power levels from small to large reactors. Integral reactors have the features of minimum vessel penetrations, passive heat removal after reactor shutdown, and modular construction that allow fast plant integration and a secure fuel cycle. The features of an integral reactor limit the options for placing control and safety system instruments. The development of instrumentation and control (I&C) strategies for a large 1,000 MWe iPWR is described. Reactor system modeling-which includes reactor core dynamics, primary heat exchanger, and the steam flashing drum-is an important part of I&C development and validation, and thereby consolidates the overall implementation for a large iPWR. The results of simulation models, control development, and instrumentation features illustrate the systematic approach that is applicable to integral light water reactors.

Development of Hard-wired Instrumentation and Control for the Neutral Beam Test Facility at KAERI

  • Jung Ki-Sok;Yoon Byung-Joo;Yoon Jae-Sung;Seo Min-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.359-365
    • /
    • 2006
  • Since the start of the KSTAR (Korea Superconducting Tokamak Advanced Research) project, Instrumentation and Control (I&C) of the Neutral Beam Test Facility (NB-TF) has been striving to answer diverse requests arising from various facets during the project's development and construction phases. Hard-wired electrical circuits have been designed, tested, fabricated, and finally installed to the relevant parts of the system. In relation to the vacuum system I&C, controlling functions for the rotary pumps, a Roots pump, two turbomolecular pumps, and four cryosorption pumps have been constructed. I&C for the ion source operation are the temperature and flow rate signal monitoring, Langmuir probe signal measurements, gradient grid current measurements, and arc detector circuit. For the huge power system to be monitored or safely operated, many temperature measurement functions have also been implemented for the beam line components like the neutralizer, bending magnet, ion dump, and calorimeter. Nearly all of the control and probe signals between the NB test stand and the control room were made to be transmitted through the optical cables. Failures of coolant flow or beam line vacuum pressure were made to be safely blocked from influencing the system by an appropriate interlock circuit that will shut down the extraction voltage application to the system or prevent damages to the vacuum components. Preliminary estimation of the beam power through the calorimetric measurement shows that 87.9% of the total power of the 60kV/18A beam with 200 seconds duration is absorbed by the calorimeter surface. Most of these I&C results would be highly appropriate for the construction of the main NBI facility for the KSTAR national fusion research project.