• Title/Summary/Keyword: $Hg^{+2}$

Search Result 2,745, Processing Time 0.024 seconds

A Selective Determination Method of Inorganic and Organic Mercury (무기수은과 유기수은의 선택정량)

  • Kim, Chon Han
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.8
    • /
    • pp.392-398
    • /
    • 1997
  • A method of selective determination of inorganic and organic mercury compounds has been described. The $CHCl_3$ solution of a high molecular quaternary alkylammonium salt, Aliquat 336 was used for the simultaneous preconcentration of both inorganic, $Hg^{2+}$ as its thiocyanate complex, and organic mercury compounds, $CH_3HgCl$ and $C_2H_3O_2$ $HgC_6H_5$ by extraction from their aqueous solution. Selective separation of the inorganic mercury from the extract was followed by stripping with 3 M $HClO_4 $ solution for the subsequent determination by CVAAS. Organic mercury was also determined by CVAAS after removal of $CHCl_3solvent$ from the extract and decomposition of the residue with 4% $KMnO_4 $-1 MH_2$S0_4$. The mixtures of inorganic and organic mercury compounds contained 1.0 $\mug$ as Hg in 50 mL of sample solution(0.02 ${\mu}gHg/mL$) were analysed within ${\pm}6%$ by absolute errors.

  • PDF

HgCdTe Junction Characteristics after the Junction Annealing Process (열처리 조건에 따른 HgCdTe의 접합 특성)

  • Jeong, Hi-Chan;Kim, Kwan;Lee, Hee-Chul;Kim, Hong-Kook;Kim, Jae-Mook
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.2
    • /
    • pp.89-95
    • /
    • 1995
  • The structure of boron ion-implanted pn junctio in the vacancy-doped p-type HgCdTe was investigated with the differential Hall measurement. The as-implanted junction showed the electron concentration as high as 1${\times}10^{18}/cm^{3}$ and the junction depth of 0.6.mu.m. When the HgCdTe junction was heated in oven, the electron concentration near the junction decreased and the junction depth increased as the annealing temperature and time increased. The junction structure after the thermal annealing was n$^{+}$/n$^{-}$/p. For the 200.deg. C 20min annealed sample, the electron mobility was 10$^{4}cm^{2}/V{\cdot}$s near the surface(n$^{+}$), and was larger thatn 10$^{5}cm^{2}/V{\cdot}$s near the junction(n$^{+}$). The junction formation mechanism is conjectured as follows. When HgCdTe is ion-implanted, the ion energy generates crystal defecis and displaced Hg atoms HgCdTe is ion-implanted, the ion energy generates crystal defecis and displaced Hg atoms near the surface. The displaced Hg vacancies diffuse in easily by the thernal treatment and a fill the Hg vacancies in the p-HgCdTe substrate. With the Hg vacancies filled completely, the GfCdTe substrate becomes n-type because of the residual n-type impurity which was added during the wafer growing. Therefore, the n$^{+}$/n$^{-}$/p regions are formed by crystal defects, residual impurities, and Hg vacancies, respectively.

  • PDF

Surgical treatment of congenital left ventricular outflow tract obstruction (선천성 좌심실유출로협착증의 수술요법)

  • 이상진
    • Journal of Chest Surgery
    • /
    • v.27 no.7
    • /
    • pp.576-580
    • /
    • 1994
  • For 26 months since August 1991, 10 consecutive patients with congenital left ventricular outflow tract obstruction underwent corrective surgery in Pusan Paik Hospital. Their ages ranged from 2 to 18 years. There were 6 male and 4 female patients. According to stenotic site, obstruction were classified into supravalvular [n = 5], subvalvular [n = 4], valvular stenosis [n = 1]. We have performed patch enlargement of ascending aorta [n = 2], supravalvular membrane resection and patch enlargement of ascending aorta [n = 3], subvalvular membrane resection [n = 2], subvalvular membrane resection and left ventricular myectomy [n = 2] and aortic annuloplasty with Dacron patch and aortic valve replacement [n = 1]. Preoperative mean value of systolic pressure gradient were 85.0 $\pm$29.2mmHg[supravalvular], 70.0mmHg[valvular], 72.5 $\pm$ 22.5mmHg[subvalvular], and 78.5 $\pm$ 24.3mmHg[total]. Postoperative mean value of systolic pressure gradient were 31.0 $\pm$ 8.9mmHg[supravalvular], 0mmHg[valvular], 15.0 $\pm$ 10.8mmHg[subvalvular], and 21.5 $\pm$ 13.9mmHg[total]. Postoperative systolic pressure gradient was decreased significantly[p = 0.001]. Postoperative course and short-term follow up results were good except one case of transient heart failure.

  • PDF

Selective Chemosensing of Hg2+ Ions by Diazatetrathia-crown Ether Having Nitrobenzoxadiazolyl Subunits

  • Kim, So-Hee;Youn, Na-Jin;Park, Ji-Yeon;Choi, Myung-Gil;Chang, Suk-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.10
    • /
    • pp.1553-1556
    • /
    • 2006
  • A diazatetrathia crown ether derivative that has two appended nitrobenzoxadiazolyl moieties showed selective OFF-ON type fluoroionophoric signaling properties toward Hg2+ ions over other transition metal ions. The compound also exhibited a pronounced chromogenic behavior toward Hg2+ ions by changing the solution color from light orange to yellow, which can easily be detected with naked-eye. The detection limit for the analysis of Hg2+ ions in 90% aqueous acetonitrile was found to be 4.8??10-6 M, which suggests that the compound may be used as a chemosensor for analyzing sub-millimolar Hg2+ ions in aqueous environments.

Pyrene Appended Hg2+-selective Fluoroionophore Based upon Diaza-Crown Ether

  • Choi, Myung-Gil;Kim, Hee-Jung;Chang, Suk-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.567-570
    • /
    • 2008
  • A new pyrene appended diaza-18-crown-6 ether derivative 1 has been prepared and its fluoroionophoric properties toward transition metal ions were investigated. Compound 1 exhibited a high Hg2+-selectivity over other transition metal ions as well as alkali and alkaline earth metal ions in aqueous acetonitrile solution. The ratiometric analysis of the monomer and excimer emissions of pyrene successfully signals the presence of Hg2+ ions. The detection limit for Hg2+ ions was found to be 3.1 ´ 10-6 M in 50% aqueous acetonitrile solution at pH 8.1. Competition experiments also suggest that the compound could be utilized as a selective and sensitive fluorescent chemosensor for the analysis of micromolar Hg2+ ions in physiological and environmental samples.

Beneficial Effect of Scutellaria baicalensis Georgi Extract on Mercury Chloride-Induced Membrane Transport Dysfunction in Rabbit Renal Cortical Slices (황금약침액(黃芩藥鍼液)이 가토(家兎) 신피질절편(腎皮質切片)에서 수은(水銀)에 의한 세포막(細胞膜) 물질이동(物質移動) 기능장애(機能障碍)에 미치는 영향(影響))

  • Kim, Hong-Soo;Song, Choon-Ho
    • Journal of Pharmacopuncture
    • /
    • v.4 no.2
    • /
    • pp.49-56
    • /
    • 2001
  • This study was undertaken to determine whether Scutellaria baicalensis Georgi (SbG) extract exerts the protective effect against $HgCl_2$-induced alterations in membrane transport function in rabbit renal cortical slices. The slices were treated with 0.1 mM $HgCl_2$ for 60 min at $37^{\circ}C$. $HgCl_2$ caused an inhibition in PAH uptake by renal cortical slices. Such an effect was accompanied by depressed $Na^+-K^+$-ATPase activity and ATP depletion. SbG prevented $HgCl_2$-induced inhibition of PAH uptake in a dose-dependent manner at the concentration ranges of 0.01-0.1%. $HgCl_2$-induced inhibition of $Na^+-K^+$-ATPase activity and ATP depletion were significantly prevented by 0.05% SbG. These results suggest that SbG prevents $HgCl_2$-induced alterations in membrane transport function in rabbit renal cortical slices. Such protective effects of SbG may be attributed to inhibition of peroxidation of membrane lipid.

The Respiratory and Hemodynamic Effect of Prone Position in Patients with ARDS (급성호흡부전증후군에서 Prone Position의 호흡 및 혈류역학적 효과)

  • Lim, Chae-Man;Koh, Youn-Suck;Jung, Bok-Hyun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1105-1113
    • /
    • 1997
  • Background : Prone position improves oxygenation in some patients with ARDS. According to some authors, prone position can also improve the deteriorated hemodynamics induced by PEEP. But these respiratory and hemodynamic effects of prone position has not yet been fully established. Methods : Twentythree consequtive patients with ARDS(M : F= 11 : 12, $62.1{\pm}20.8yrs$) were the subjects for this study. ABGA, static compliance of the respiratory system, mean arterial pressure and pulse rate were obtained in supine position and at 5min, 0.5h and 2h of prone position. Positive respiratory response was defined as 20mmHg or more increase in $PaO_2/FIO_2$ within 2h of prone position. Early of late respiratory responses were defined if the positive response was observed within of after 3 day of ARDS onset, respectively. Positive hemodynamic response was defined as 10mmHg or more increase in mean arterial pressure at 5min of prone position. Results : Fifteen patients (65%) showed positive respiratory response. In the respiratory responders, $PaO_2$ was $69.8{\pm}17.6mmHg$ in supine position, $83.2{\pm}22.6mmHg$ in prone position 0.5h, $96.8{\pm}22.7mmHg$ in prone position 2h(p<0.001), and $PaO_2/FIO_2$ was $108{\pm}41mmHg$, $137{\pm}57mmHg$, $158{\pm}50mmHg$, respectively(p=0.001). Age, sex, cause of ARDS, supine $PaO_2$ and $PaO_2/FIO_2$ were not different between the respiratory responders and the nonresponders. The respiratory responders, however, showed higher mean arterial pressure than the nonresponders($91.1{\pm}13.1mmHg$ vs. $76.0{\pm}18.7mmHg$, p=0.035), and tendency of higher survival rate(9/15 vs. 2/8, p=0.074). Static compliance of the respiratory system was decreased in prone position 0.5h($28.4{\pm}7.9ml/cm$ $H_2O$ vs. $23.8{\pm}7.6ml/cm$ $H_2O$, p=0.007). The overall rate of early response(n=23) and late response(n=11) were similar(14/23 vs. 7/11, p>0.05). But patient without early response showed late response only in 25%(1/4), while patient with early response showed late response in 85.7%(6/7)(p=0.072). Five patients(22%) showed positive hemodynamic response, two of them being respiratory nonresponders. There were no differences in the baseline mean arterial pressure or the level of PEEP applied in supine between the hemodynamic responders and the hemodynamic nonresponders. Conclusions : Prone position either improved oxygenation or increased arterial pressure in significant proportion of patients with ARDS. And the respiratory response to prone position was thought to be determined in the early stage of ARDS.

  • PDF

Determination of Hg22+ Ions Using a Modified Glassy Carbon Electrode with 2,2':6':2''-Terpyridine

  • Kong, Young-Tae;Bae, Yun-Jung;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.2
    • /
    • pp.346-350
    • /
    • 2002
  • A glassy carbon electrode (GCE) modified with 2,2':6':2”-terpyridine (2,2':6':2”-TPR) using a spin coating method was applied for the highly selective and sensitive analysis of a trace amount of $Hg_2^{2+}$ ions. Various experimental parameters, which influenced the response of the 2,2':6':2”-TPR modified electrode to $Hg_2^{2+}$ ions, were optimized. The linear sweep and differential pulse voltammograms for the 2,2':6':2”-TPR modified electrode deposited with Hg show a well-defined anodic peak at +0.65 V (vs. Ag|AgCl). After a 25 min preconcentration time in an $Hg_2^{2+}$ ion solution (0.1 M acetate buffer, pH 5.0), differential pulse voltammetry(DPV) with 2,2':6':2”-TPR modified electrode shows a linear response between $1.0\;{\times}\;10^{-6}M\;and\;2.0\;{\times}\;10^{-7}M$. The least-square treatment of these data produce an equation of I[${\mu}A$] = 0.031 + 0.005C with r = 0.980(n = 5). The detection limit of this electrode with linear sweep voltammetry and differential pulse anodic voltammetry were $2.0\;{\times}\;10^{-6}M\;and\;8.0\;{\times}\;10^{-8}M$, respectively. The presence of Pb, Fe, Cd, Ti, Ni, Co, Mg, Al, Mn, and Zn did not interfere in the analysis of the $Hg_2^{2+}$ ion. The 2,2':6':2”-TPR modified GCE has been successfully applied in determination trace amounts of Hg in a human urine sample.

Separation and Concentration of Trace Mercury [Hg(II)] in Water Sample by Coprecipitation Flotation Technique (공침-부선기술에 의한 수용액 시료 중 흔적량 수은 [Hg(II)]의 분리 및 농축)

  • Lee Kang-Seok;Choi Hee-Seon;Kim Seon-Tae;Kim Young-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.355-361
    • /
    • 1991
  • The separative preconcentration of trace mercury[Hg(II)] in a water sample was studied by a coprecipitation flotation technique. The trace Hg(II) was precipitated together with Ce(OH)$_3$ by adding 3.0 ml of 0.1M Ce$^{3+}$ solution to 1,000 ml of water sample and adjusting pH to 11.0 with 1.0M NaOH solution. The hydrophobic precipitate[Ce(OH)$_3$-Hg(OH)$_2$], which was formed by adding 2.0 ml of 0.1${\%}$ ethanolic sodium oleate solution, were floated on the surface with an aid of tiny nitrogen gas bubbles. The floated materials were quatitatively collected in a suction flask and dissolved with 5.0 ml of 2.0M HNO$_3$. The solution was marked to 25.00 ml with a deionized water. The content of Hg(II) was determined by cold vapor atomic absorption spectrophotometry. Any interferences of concomitants such as Ag$^+$, Br$^-$, I$^- $, etc. were not observed on the whole procedure. The analytical result showed that Hg(II) found in the wastewater of Seochang Campus, Korea University was 1.98 ng/ml with the relative standard deviation of 3.6${\%}$. And recoveries of Hg(II) in the wastewater into which 1.0 ng/ml and 2.0 ng/ml were added were 95${\%}$ and 91${\%}$, respectively. From such results, this procedure could be concluded to be tolerably accurate and reproducible for the determination of trace mercury in a water sample.

  • PDF

Spectrophotometric Determination of Trace Hg(II) in Cetyltrimethylammonium Bromide Media

  • Jeoung, Moon-Sook;Choi, Hee-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.12
    • /
    • pp.1877-1880
    • /
    • 2004
  • The simple and convenient determination of trace Hg(II) with its 2-mercaptobenzothiazole (MBT) complex in cetyltrimethylammonium bromide (CTAB) media has been studied. The UV-visible spectrum of Hg(II)-MBT complex in CTAB media had a good sensitivity and reproducibility. The Hg(II)-MBT complex in CTAB solution was very stable at pH 10.0 and could be quantitatively complexed if MBT were added to the sample solution more than 10 equivalent of Hg(II). The optimum concentration of CTAB was 0.001%. The calibration curve of Hg(II)-MBT complex with good linearity ($R^2$ = 0.9985) was obtained at the concentration range between $1.0{\times}10^-7$ and $1.0{\times}10^-5$ M in 0.001% CTAB media. The detection limit was $3.1{\times}10^-8$ M (6.2 ng m$L^{-1}$). Hg(II) in the synthetic samples and in the wastewater of the university's wastewater tank and the industrial wastewater tank could also be determined. Based on the experimental results, this proposed technique could be applied to the simple and convenient determination of trace Hg(II) in real samples.