• 제목/요약/키워드: $H_2S$ partial pressure

검색결과 80건 처리시간 0.024초

Magnetic Properties of Polycrystalline ${BaFe_{12}{O_{19}$ Films Grown by a Pulsed Laser Ablation Technique

  • Sang Won Kim;Choong Jin Yang
    • Journal of Magnetics
    • /
    • 제1권1호
    • /
    • pp.46-50
    • /
    • 1996
  • Highly oriented ${BaFe_{12}{O_{19}$ films were obtained by a KrF excimer laser ablation technique using (110)$(012){Al_2}{O_3}$(001)$(012){Al_2}{O_3}$ and $(012){Al_2}{O_3}$ substrates, respectively.The degree of alignment of more than 95% were achieved for (100) on (110)$(012){Al_2}{O_3}$ and (001)$(001){Al_2}{O_3}$ planes, and heteroepitaxial films of (114) on (012)$(012){Al_2}{O_3}$were possible to be grown with a lasing energy density of 6.67 J/$cm^2$ at an oxygen partial pressure ${PO_2}$ of 900 mTorr. The best magnetic properties were obtained from the as-deposited films at the substrate temperature of $700^{\circ}C$, and post annealing treatment was not needed to enhance the magnetic properties. Experimentally saturated magnetization ($4_pi M_S$) of 3600~3800 Gauss and coercivities $(H_c)$ of 3050~3080 Oe, which approach 85% of those of Ba-ferrite bulk composed of single domain particles, were obtained in this study.

  • PDF

Extracorporeal Membrane Oxygenation in Pediatric Patients with Respiratory Failure: Early Experience with the Double-Lumen Cannula Over 2 Years

  • Kim, Woojung;Kwon, Hye Won;Min, Jooncheol;Cho, Sungkyu;Kwak, Jae Gun;Kim, Woong Han
    • Journal of Chest Surgery
    • /
    • 제53권3호
    • /
    • pp.132-139
    • /
    • 2020
  • Background: The double-lumen cannula (DLC) has begun to be used worldwide for venovenous (VV) extracorporeal membrane oxygenation (ECMO). We aimed to examine whether the DLC could be an effective tool in the treatment of pediatric respiratory failure in Korea. Methods: We reviewed the records of patients weighing under 15 kg who underwent ECMO due to respiratory failure between January 2017 and December 2018. Outcomes of ECMO using a DLC and conventional ECMO using central method or 2 peripheral cannulas were compared. Results: Twelve patients were treated with ECMO for respiratory failure. Among them, a DLC was used in 5 patients, the median age of whom was 3.8 months (interquartile range, 0.1-49.7 months). In these patients, the median values of pH, partial pressure of carbon dioxide, and partial pressure of oxygen were 7.09, 74 mm Hg, and 37 mm Hg before ECMO and corrected to 7.31, 44 mm Hg, and 85 mm Hg, respectively, after ECMO cannulation. Median blood flow rate in the patients treated with ECMO using a DLC was slightly higher than that in the conventional ECMO group, but this difference was not statistically significant (86.1 mL/kg/min and 74.3 mL/kg/min, respectively; p=1.00). One patient from the DLC group and 3 patients from the conventional group were weaned off ECMO. Conclusion: VV ECMO using a DLC provided adequate oxygenation, ventilation, and blood flow rate in Korean pediatric patients with respiratory failure. Further prospective and randomized studies are warranted.

스크린 인쇄법을 이용한 NASICON 후막 SO2가스 센서의 제조 및 특성 (Fabrication and Sensing Properties of NASICON Thick Film SO2 Gas Sensor Using Screen-print Method)

  • 배재철;이상태;전희권;방영일;이덕동;허증수
    • 한국재료학회지
    • /
    • 제13권2호
    • /
    • pp.115-119
    • /
    • 2003
  • The thick film type sensor having Pt/Na Super Ionic Conductor(NASICON) solid electrolyte/Pt/$Na_2$$SO_4$/Pt catalyst system for $SO_2$gas was fabricated by screen-print method. The phase of Na Super Ionic Conductor solid electrolyte sintered at different temperature of 1050, 1150,$ 1250^{\circ}C$ and for different time of 1.5, 2.5, 3.5 hr were investigated by XRD. The Electromotive Force variation of the sensor with $SO_2$concentrations and operating temperatures were investigated. The major phase of Na Super Ionic Conductor film sintered at 115$0^{\circ}C$ for 3.5 hr was sodium zirconium silicon phosphate($Na_3$Zr$_2$$Si_2$PO$_{12}$). The Nernst's slope of Na Super Ionic Conductor sensor for $SO_2$gas with the variation of concentration from 10 to 100 ppm was 167.14 ㎷/decade at the operating temperature of $500 ^{\circ}C$. The increase of oxygen partial pressure was not affected to the variation of Nernst's slope.e.

$BaHfO_3$ 완충층을 사용한 IBAD MgO 기판 위에 제조된 고임계전류밀도의 $GdBa_2Cu_3O_y$ 박막 (High-$J_c$ $GdBa_2Cu_3O_y$ films on $BaHfO_3$ buffered IBAD MgO template)

  • 고경필;이정우;고락길;문승현;오상수;유상임
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.6-11
    • /
    • 2011
  • The $BaHfO_3$ (BHO) buffer layer on the IBAD MgO template was turned to be effective for a successful fabrication of $GdBa_2Cu_3O_{7-{\delta}}$ (GdBCO) films with high critical current density ($J_c$). Both the BHO buffer layers and GdBCO films were prepared by pulsed laser deposition (PLD). The effects of the PLD conditions, including substrate temperature ($T_s$), oxygen partial pressure ($PO_2$), and deposition time on the in-plane texture, surface roughness, and microstructures of the BHO buffer layers on the IBAD MgO template were systematically studied for processing optimization. The c-axis oriented growth of BHO layers was insensitive to the deposition temperature and the film thickness, while the in-plane texture and surface roughness of those were improved with increasing $T_s$ from 700 to $800^{\circ}C$. On the optimally processed BHO buffer layer, the highest $J_c$ value (77 K, self-field) of 3.68 $MA/cm^2$ could be obtained from GdBCO film deposited at $780^{\circ}C$, representing that BHO is a strong candidate for the buffer layer on the IBAD MgO template.

SULFIDATION PROCESSING AND Cr ADDITION TO IMPROVE OXIDATION RESISTANCE OF Ti-Al INTERMETALLIC COMPOUNDS AT ELEVATED TEMPERATURES

  • Narita, Toshio;Izumi, Takeshi;Yatagai, Mamoru;Yoshioka, Takayuki
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 1999년도 춘계학술발표회 초록집
    • /
    • pp.5-5
    • /
    • 1999
  • A novel process is proposed to improve oxidation resistance of Ti-Al intermetallic compounds at elevated temperatures by both Cr addition and pre-sulfidation, where TiAl alloys withlor without Cr addition were sulfidized at 1173K for 86.4ks at a 1.3 Pa sulfur partial pressure in a $H_2-H_2S$ gas mixture. The pre-sulfidation treatment formed a thin Cr-Al alloy layer as well as 7~10 micrometer $TiAl_3$ and $TiAl_2$ layer, due to selective sulfidation of Ti. Oxidation resistance of the pre-sulfidation processed TiAl 4Cr alloy was examined under isothermal and heat cycle conditions between room temperature and 1173K in air. Changes in $TiAl_3$ into $TiAl_2$ and then TiAl phases as well as their effect on oxidation behavior were investigated and compared with the oxidation behavior of the TiAl-4Cr alloy as TiAl and pre-sulfidation processed TiAl aHoys. After oxidation for up to 2.7Ms a protective $Al_2O_3$ scale was formed, and the pre-formed $TiAl_3$ changed into $TiAl_2$ and the $Al_2Cr$ phase changed into a CrAlTi phase between the $Al_2O_3$ scale and $TiAl_2$ layer. The pre-sulfidation processed TiAl-4Cr alloy had very good oxidation resistance for longer times, up to 2.7 Ms, in contrast to those observed for the pre-sulfidation processed TiAl alloy where localized oxidation occurred after 81 Oks and both the TiAl and TiAl-4Cr alloys themselves corroded rapidly from the initial stage of oxidation

  • PDF

식품보장과 수분활성에 관한 연구 1. 조절기류에 의한 건조말쥐치육의 등온흡습곡선의 측정 (Studies on Food Preservation by Controlling Water Activity 1. Measurement of Sorption Isotherm of Dried Filefish Muscle by Equilibration in Dynamic Stream of Conditioned Air)

  • 한봉호;최수일
    • 한국수산과학회지
    • /
    • 제14권4호
    • /
    • pp.189-193
    • /
    • 1981
  • 등온흡습곡선측정시의 건제품이 주어진 대상습도에서 평형에 이르는 시간을 단축시키기 위하여 조절기류를 이용하는 장치를 만들고, 이를 이용하여 $25^{\circ}C$에서 말쥐치 건제품의 등온흡습곡선을 측정하였다. 1. 조절기류를 이용함으로써 주어진 수분활성에서보다 높은 수분활성에 이르는 시간을 평균 45 시간으로 단축시킬 수 있었다. 2. 단분자의 수분함양은 고형물 1kg당 0.092kg이었으며, 건조말쥐치의 제품에 대하여 $8.42\%$였다. Symbols used in the text A : surface, $m^2$ $a_w$: water activity $A_s$ : specific surface, $m^2/kg$ dry matter C : constant related to the heat of adsorption $K_g$ : gas film coefficient of mass transfer, $kg water/hr{\cdot}Pa{\cdot}m^2$ n : number of molecular layers $n_s$ : moisture content, kg water /kg dry matter $n_{sa}$ : mean moisture content, kg water/kg dry matter $n_{se}$ : equilibrium moisture content, kg water/kg dry matter $n_{sm}$ : moisture content for monolayer, kg water/kg dry matter $P_g$ : saturated vapor pressure at wet-bulb temperature, Pa $P_a$ : partial vapor pressure of water in air, Pa $R_d$ : resistance factor against diffusion, $m^2{\cdot}hr/kg$ dry matter $R_s$ : resistance factor against drying, $m^2{\cdot}hr/kg$ dry matter R.H. : relative humidity, $\%$ $\varphi$ : R.H./100

  • PDF

시간응답특성을 고려한 2광원 1센서 방식의 capnograph 시스템용 NDIR식 $CO_2$ 가스 챔버 설계 및 측정 회로의 구현 (An implementation of NDIR type $CO_2$ gas sample chamber and measuring hardware for capnograph system in consideration of the time response characteristics)

  • 박일용;이인기;이성기;강경목;강신원;조진호
    • 센서학회지
    • /
    • 제10권5호
    • /
    • pp.279-285
    • /
    • 2001
  • 본 논문에서는 동맥혈중 이산화탄소 분압을 실시간으로 추정하는 capnograph 시스템에 상용되는 대부분 NDIR 흡수식(non-dispersive infrared absorption) 광챔버와 신호처리회로를 설계 및 구현하였다. 광챔버 설계시 일반 정상인의 capnogram을 주파수 분석하여 적합한 광쵸핑 주파수를 결정한 뒤, 이에 근거하여 시간응답을 고려한 광챔버를 설계하였으며, 열잡음에 대한 영향을 줄이기 위해 2광원 1센서 방식의 $CO_2$ 농도 신호처리회로를 구현하였다. 구현된 광챔버에 대한 가스배출시간을 조사하였으며 신호처리회로를 외부 온도 변화 실험에 적용한 결과 2광원 1센서 방식이 안정된 출력 신호를 얻을 수 있음을 확인하였고, 실제 사람의 호흡에 대한 실험결과 정상적인 capnogram 형태의 $CO_2$ 농도 변화 곡선을 보였다.

  • PDF

SF6 가스중의 공진주파수에 따른 신호특성 (Characteristic as a Resonance Frequency of $SF_6$ Gas)

  • 이용희;이현동;박정남;신양섭;박장수;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1867-1869
    • /
    • 2003
  • In this paper, chamber(Circuit breaker compartment of C-GIS) made of stainless steel with 4 mm width is used. Artificial defect was made on enclosure or HV conductor of chamber and $SF_6$ gas was injected into it according to pressure. In this experiment, Acoustic emission sensors of different types was used to compare sensitivity to detect acoustic signal occurred by Partial discharge(PD) of according to types and resonance frequency in $SF_6$ gas atmosphere. Sensors used in tests was R6I, R15I and 2/4/6 Pre-Amplifier connected with R6IU without pre. amp. In case of R6IU, gain was adjusted with 40 dB like other sensors and operated by differential mode. Post amplifier(post. amp) and band pass filter(BPF) were developed Gain of post. amp. is 60 dB and BPF has band width of $50{\sim}300$ kHz. Also, envelope circuit developed reduces frequency of AE sensor. As a result, in $SF_6$ atmosphere, R6IU and R6I had resonance frequency of 60 Hz was better than R15I. Also, R6IU was better than R6I because of type property of pre.amp. had differential mode.

  • PDF

R.F. 마그네트론 스퍼터링을 이용한 LiCoO2 양극활물질의 Ar 증착분압에 따른 박막전지 전극 특성 (Electrode Properties of Thin Film Battery with LiCoO2 Cathode Deposited by R.F. Magnetron Sputtering at Various Ar Partial Pressures)

  • 박호영;임영창;최규길;이기창;박기백;권미연;조성백;남상철
    • 전기화학회지
    • /
    • 제8권1호
    • /
    • pp.37-41
    • /
    • 2005
  • Ar공정 분압에 따라 스퍼터링된 $LiCoO_2$박막 양극의 $400^{\circ}C$저온 열처리를 통한 전기화학적 및 미세구조적 특성을 연구하였다. Ar분압이 변화함에 따라 양극 박막의 미세구조 및 조성이 변화하였으며, Ar분압이 증가할수록 $LiCoO_2$ 박막의 안정성 및 전기화학적 특성이 개선되었다. 순환전류전위법 및 정전류 충방전 시험에 의해 전극반응의 가역성 및 안정성 등을 고찰하였으며, 박막의 조성, 결정성, 표면 특성 등 물리적 특성은 ICP-AES, XRD, SEM 및 AFM을 통해 분석하였다.

고압 자전 고온반응 합성법에 의한 B4C-Al2O3복합분말 제조 (Preparation of B4C-Al2O3 Composite Powder by Self-propagation High-temperature Synthesis(SHS) Process under High Pressure)

  • 임경란;강덕일;김창삼
    • 한국세라믹학회지
    • /
    • 제40권1호
    • /
    • pp.18-23
    • /
    • 2003
  • 정량의 B$_2$O$_3$/A1/C의 혼합분말을 화학노 대신 고압의 알곤 분위기를 사용하여 SHS 공정으로 B$_4$C-A1$_2$O$_3$ 복합분말을 제조하였다. 2B$_2$O$_3$+4A1+C=B$_4$C-2A1$_2$O$_3$의 반응식에 해당하는 B$_2$O$_3$(-100 메쉬), Al(-200 메쉬), C(-200 메쉬)의 분말을 2시간 건식 볼밀로 혼합한 후, 고온 고압의 SHS 반응기에 넣고 약 10기압의 알곤 분위기에서 점화하여 SHS을 일으켰다. 반응 생성물은 XRD 분석으로 안과 겉이 균일하게 반응이 일어났으며 반응 생성물로 화학노 사용시 동반되는 부산물 AlB$_{12}$C$_2$가 없는 B$_4$C-A1$_2$O$_3$ 복합 분말을 얻었다. 이 복합 분말은 SEM으로 보면 약 0.3~l $mu extrm{m}$ 크기의 결정이 모인 약 60~100$\mu\textrm{m}$ 크기이었다. 그러나 약 15기압을 사용하였을 때는 부분 소결이 일어나 15~25$\mu\textrm{m}$ B$_4$C 분말에 0.1~0.2$\mu\textrm{m}$의 알루미나가 분산되어 있는 고강도의 복합 분말이 생성되었다.