Magnetoelectric Characteristics on Layered Ni-PZT-Ni, Co, Fe Composites for Magnetic Field Sensor (자기센서용 Ni-PZT-Ni, Co, Fe 적층구조 소자의 ME 특성)

  • Ryu, Ji-Goo;Jeon, Seong-Jeub
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.92-98
    • /
    • 2015
  • The magnetoelectric characteristics on layered Ni-PZT-Ni, Co, Fe composites by epoxy bonding for magnetic field sensor were investigated in the low-frequency range. The ME coefficient of Ni-PZT-Ni, Ni-PZT-Co and Ni-PZT-Fe composites reaches a maximum of $200mV/cm{\cdot}Oe$ at $H_{dc}=110$ Oe, $106mV/cm{\cdot}Oe$ at $H_{dc}=90$ Oe and $87mV/cm{\cdot}Oe$ at $H_{dc}=160$ Oe, respectively. A trend of ME charateristics on Ni-PZT-Co, Ni-PZT-Fe composites was similar to that of Ni-PZT-Ni composites. The ME output voltage shows linearly proportional to ac field $H_{ac}$ and is about 0~150 mV at $H_{ac}$=0~7 Oe and f=110 Hz in the typical Ni-PZT-Ni sample. The frequency shift effect due to the load resistance $R_L$ shows that the frequency range for magnetic field sensor application can be modulated with appropriate load resistance $R_L$. This sample will allow for a low-magnetic ac field sensor in the low-frequency (near f=110 Hz).

Binary Metal Oxide ($IrO_2-RuO_2$) pH Sensor Prepared by Sol-gel Method (Sol-gel 법을 이용한 이성분 금속산화물 ($IrO_2-RuO_2$) pH 센서)

  • Lee, Jeong-Ran;Oh, Se-Lim;Han, Won-Sik;Hong, Tae-Kee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.190-196
    • /
    • 2014
  • The sol-gel method was used to prepare binary metal oxide ($IrO_2-RuO_2$) pH sensor. The electrodes that mole percent compositions (mol%) of $IrO_2$ and RuO2 were 70:30 and 30:70 were selected. The characterizations of Nernstian response over pH range, response rate, interference on alkaline metals and reproducibility were investigated. Also the electroanalytical properties of these electrodes were evaluated in comparison with a commercial glass pH electrode. The composition of $IrO_2:RuO_2$ 70:30 mol% was chosen as better electrode formulation. The electrode was not susceptible to the action of interfering ions such as $Li^+$, $Na^+$ and $K^+$.

Hydrogen sensor using Pt-loaded porous In2O3 nanoparticle structures (백금 담지 다공성 산화인듐 나노입자 구조를 이용한 수소센서)

  • Sung Do Yun;Yoon Myung;Chan Woong Na
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.6
    • /
    • pp.420-426
    • /
    • 2023
  • We prepared a highly sensitive hydrogen (H2) sensor based on Indium oxides (In2O3) porous nanoparticles (NPs) loaded with Platinum (Pt) nanoparticle in the range of 1.6~5.7 at.%. In2O3 NPs were fabricated by microwave irradiation method, and decorations of Pt nanoparticles were performed by electroless plating on In2O3 NPs. Crystal structures, morphologies, and chemical information on Pt-loaded In2O3 NPs were characterized by grazing-incident X-ray diffraction, field-emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, respectively. The effect of the Pt nanoparticles on the H2-sensing performance of In2O3 NPs was investigated over a low concentration range of 5 ppm of H2 at 150-300 ℃ working temperatures. The results showed that the H2 response greatly increased with decreasing sensing temperature. The H2 response of Pt loaded porous In2O3 NPs is higher than that of pristine In2O3 NPs. H2 gas selectivity and high sensitivity was explained by the extension of the electron depletion layer and catalytic effect. Pt loaded porous In2O3 NPs sensor can be a robust manner for achieving enhanced gas selectivity and sensitivity for the detection of H2.

Gas sensing pattern in chungkukjang production using household fermentation system (가정용 발효기를 이용한 청국장 제조과정의 가스감지 패턴)

  • Jung, H.C.;Choi, S.Y.;Kim, J.B.
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.72-76
    • /
    • 2009
  • The sensing system was designed and fabricated to investigate the ferment environment of soybeans. $NH_3$ gas was saturated after about 7 h and $CO_2$ gas was reached the peak after about 8 h in the inoculation of Bacillus subtilis. However, times that $CO_2$ gas and $NH_3$ gas were reached maximum value without Bacillus subtilis were about 15 h and 18 h, respectively. The sample that inoculated Bacillus subtils had deeper taste than one without it. We found that the peak time of $CO_2$ gas means the starting time of fermentation. If we control the operating time after the start of fermentation, it is expected to make a suitable Chungkukjang to individual preference.

A Study on Pattern Analysis of Odorous Substances with a Single Gas Sensor

  • Kim, Han-Soo;Choi, Il-Hwan;Kim, Sun-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.423-430
    • /
    • 2016
  • This study used a single metal oxide semiconductor (MOS) sensor to classify the major odorous gases hydrogen sulfide ($H_2S$), ammonia ($NH_3$) and toluene ($C_6H_5CH_3$). In order to classify these odorous substances, the voltage on the MOS sensor heater was gradually reduced in 0.5 V steps 5.0 V to examine the changes to the response by the cooling effect on the sensor as the voltage decreased. The hydrogen sulfide gas showed the highest sensitivity compared to odorless air under approximately 2.5 V and the ammonia and toluene gases showed the highest sensitivity under approximately 5.0 V. In other words, the hydrogen sulfide gas reacted better in the low temperature range of the MOS sensor, and the ammonia and toluene gases reacted better in the high-temperature range. In order to analyze the response characteristics of the MOS sensor by temperature in a pattern, a two-dimensional (2D) x-y pattern analysis was introduced to clearly classify the hydrogen sulfide, ammonia, and toluene gases. The hydrogen sulfide gas was identified by a straight line with a slope of 1.73, whereas the ammonia gas had a slope of 0.05 and the toluene gas had a slope of 0.52. Therefore, the 2D x-y pattern analysis is suggested as a new way to classify these odorous substances.

Fabrication and Temperature Compensation of Silicon Piezoresistive Absolute Pressure Sensor for Gas Leakage Alarm System (가스누출 감지용 실리콘 압저항형 절대압센서의 제조 및 온도보상)

  • Son, Seung-Hyun;Kim, Woo-Jeong;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.171-178
    • /
    • 1998
  • Silicon piezoresistive absolute pressure sensor for gas leakage alarm system was developed. This sensor must operate normally in the range of $0{\sim}600\;mmH_{2}O$ pressure, and $0{\sim}100^{\circ}C$ temperature. To make the most of this sensor for gas leakage alarm system, gas must not leak from the sensor itself when the diaphragm of the sensor fractures. Thus, the sealed diaphragm cavity was anodically bonded to pyrex 7740 glass under the condition of $10^{-4}$ torr, at $400^{\circ}C$. The sensitivity of developed sensor was $4.06{\mu}V/VmmH_{2}O$ for $600\;mmH_{2}O$ full-scale pressure range. And temperature compensation method of this sensor is to change bridge-in put-voltage linearly in proportion to the temperature variation by using diode(PXIN4001) or Al thin film resistor. By these methods the temperature effect in the range of $0{\sim}100^{\circ}C$ was compensated over 80 % for offset drift, 95 % for sensitivity.

  • PDF

Yeast Loading BOD Biosensor (효모균을 이용한 BOD Biosensor)

  • Kim, Mal-Nam
    • The Korean Journal of Mycology
    • /
    • v.23 no.4 s.75
    • /
    • pp.354-358
    • /
    • 1995
  • A yeast loading biochemical oxygen demand (BOD) sensor was designed and constructed to quickly measure the concentration of biologically assimilable organic substances dissolved in water as BOD values to feed back to the waste water treating processes. The sensitivity of the BOD sensor reached maximum at around pH 7.0 and $30^{\circ}C$ where yeast showed the highest assimilation activity. Biomass also affected the sensor output, and biomass of $ 0.14\;mg/cm^2$ on the dialysis membrane appeared to be the optimum cell mass level. The sensitivity of the sensor depended on the kinds of pollutants and increased considerably when the yeast was preincubated in the solution of respective pollutants before loading on the sensor.

  • PDF

Fabrication and pH response characteristics of LAPS(Light addressable potentiometric sensor) with electrolyte/$Si_3N_4/SiO_2$/Si structure (Electrolyte/$Si_3N_4/SiO_2/Si$ 구조의 LAPS 제작 및 pH 응답특성)

  • Chang Su-Won;Koh Kwang-Nak;Kang Shin-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.40-44
    • /
    • 1998
  • The LAPS device of fast response and high sensitivity, based on electrochemical potential difference, and its system were fabricated for the precise measurement of pH changes and its characteristic were investigated. The electrostatic variation characteristics of LAPS according to the pH changes and parameters in the device were verified through a simulation using LAPS equivalent circuit model. The LAPS device and its system were fabricated on the basis of the result of simulation. The fabricated LAPS system showed linear sensitivity (about 56 mV/pH within the range of pH 2 to pH 11. In order to overcome the defect of general urea sensor (especially slow response time), urease immobilized nitrocellulose membrane was attached on the LAPS and resulted in the very fast response time, 0.29 mV/sec, 0.86 mV/sec at urea concentration of $50{\mu}g/ml,\; 500{\mu}g/ml$, respectively. And also in order to measure the uranyl ion, the uranyl ion selective sensing membrane with calix[6]arene derivative was used and its sensitivity was 25mV/concentration decade in the wide uranyl ion concentration range of $10^{-11}M\;to\;10^{-4}M$.

Sensitivity of BOD Sensor with Heavy Metal Tolerant Serratia marcescens LSY4 (Serratia marcescens LSY4 중금속 내성주를 이용한 BOD센서의 감응도)

  • Kim Mal-Nam;Lee Sun-Young
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.394-399
    • /
    • 2004
  • A BOD sensor was prepared with S. marcescens LSY4 and was applied for measurement of BOD values of a solution containing the standard organic pollutants. The sensor sensitivity was nearly independent of the culture time in the range of 9-16 hours. It was also affected little by the cell mass in the range of 0.22-0.75 mg $cm^{-2}$. A cyclic change in the solution pH in the range of 4-9 was accompanied by a reversible variation in the sensor sensitivity. However, the reversibility was lost when the solution pH became more acidic or more basic. Heavy metal ions lowered the sensor sensitivity, which took place more precipitously in the presence of $Cu^{2+}$ and $Ag^+$ rather than in the presence of $Zn^{2+}$ and $Cd^{2+}$. The reduction of the sensor sensitivity was significantly attenuated by loading heavy metal ion tolerance induced strain. The $Cu^{2+}$tolerance induced strain was more efficient for the attenuation than $Zn^{2+}$ and $Cd^{2+}$ tolerance induced strain.