• Title/Summary/Keyword: $H_2$ sensor

Search Result 1,048, Processing Time 0.029 seconds

A Study on the Pressure Sensor for the Direct Detection of the Approach to the Dangerous Power Facilities Using Pb-free BNKT Ceramics (무연 BNKT 세라믹스를 이용한 위해(危害)전력설비 접근 직접감지용 압력센서에 관한 연구)

  • Hong, Jae-Il;Yoo, Ju-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.31-34
    • /
    • 2006
  • A infrared rays sensor or ultrasonic sensor can detect the object at the narrow area, however a pressure sensor can detect man and animal at the wide area. It is necessary to manufacture the sensor by using Pb-free ceramics in the respect of environmental protection. Piezoelectric properties of ceramics added 0.2wt% $La_2O_3\;into\;0.96Bi_{0.5}(Na_{0.84}K_{0.16})_{0.5}+0.04SrTiO_3$ were 0.4 of kp, $31{\times}$10^{-3}Vm/N\;of\;g_{33}$. The output voltage of the pressure sensor is 0.48 V at 20 in$H_2O$. The output voltage of the pressure sensor with driving circuit is 9.8 V, 37 ms width.

A Study on the Development of Ultrasonic Urine Volume Detection Sensor and the Correlation between Urine Volume and Bladder Interwall Distance (초음파 뇨량검출 센서의 제작 및 방광 벽간거리와 뇨량과의 상관관계에 관한 연구)

  • Choi, H.H.;Lee, E.H.
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.256-267
    • /
    • 2000
  • In this paper, we studied the ultrasonic urine volume sensor of urinary alarm system for home use to detect the time of urination as a assistive methodology for the incontinence patients and the correlation between urine volume and bladder interwall distance by using developed sensor. The developed sensor was designed to minimize the measurement error by using ultrasound with 2.25 MHz center frequency which provides higher resolution as well as longer penetration depth. To verify usefulness of the developed sensor, we performed a preliminary experiment of estimating bladder volume from the measured distance between interior and posterior wall of bladder. In the preliminary experiment, bladder volume estimated from the result using a commercial ultrasonography system. The experimental results show there exists god correlation between the actual urine volume and the measured interwall distance of the bladder. In conclusion, the developed ultrasound bladder volume sensor can be applied to an urine alarm system which provides patient the exact time of urination, it will be contribute in health care and welfare society.

  • PDF

Quasi-Solid-State Hybrid Electrolytes for Electrochemical Hydrogen Gas Sensor

  • Kim, Sang-Hyung;Han, Dong-Kwan;Hong, SeungBo;Jeong, Bo Ra;Park, Bok-Seong;Han, Sang-Do;Kim, Dong-Won
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.294-301
    • /
    • 2019
  • The quasi-solid-state hybrid electrolytes were synthesized by chemical cross-linking reaction of methacrylate-functionalized $SiO_2$ ($MA-SiO_2$) and tetra (ethylene glycol) diacrylate in aqueous electrolyte. A quasi-solid-state electrolyte synthesized by 6 wt.% $MA-SiO_2$ exhibited a high ionic conductivity of $177mS\;cm^{-1}$ at room temperature. The electrochemical $H_2$ sensor assembled with quasi-solid-state electrolyte showed relatively fast response and high sensitivity for hydrogen gas at ambient temperature, and exhibited better durability and stability than the liquid electrolyte-based sensor. The simple construction of the sensor and its sensing characteristics make the quasi-solid-state hydrogen sensor promising for practical application.

A Multi-sensor basedVery Short-term Rainfall Forecasting using Radar and Satellite Data - A Case Study of the Busan and Gyeongnam Extreme Rainfall in August, 2014- (레이더-위성자료 이용 다중센서 기반 초단기 강우예측 - 2014년 8월 부산·경남 폭우사례를 중심으로 -)

  • Jang, Sangmin;Park, Kyungwon;Yoon, Sunkwon
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.2
    • /
    • pp.155-169
    • /
    • 2016
  • In this study, we developed a multi-sensor blending short-term rainfall forecasting technique using radar and satellite data during extreme rainfall occurrences in Busan and Gyeongnam region in August 2014. The Tropical Z-R relationship ($Z=32R^{1.65}$) has applied as a optimal radar Z-R relation, which is confirmed that the accuracy is improved during 20mm/h heavy rainfall. In addition, the multi-sensor blending technique has applied using radar and COMS (Communication, Ocean and Meteorological Satellite) data for quantitative precipitation estimation. The very-short-term rainfall forecasting performance was improved in 60 mm/h or more of the strong heavy rainfall events by multi-sensor blending. AWS (Automatic Weather System) and MAPLE data were used for verification of rainfall prediction accuracy. The results have ensured about 50% or more in accuracy of heavy rainfall prediction for 1-hour before rainfall prediction, which are correlations of 10-minute lead time have 0.80 to 0.53, and root mean square errors have 3.99 mm/h to 6.43 mm/h. Through this study, utilizing of multi-sensor blending techniques using radar and satellite data are possible to provide that would be more reliable very-short-term rainfall forecasting data. Further we need ongoing case studies and prediction and estimation of quantitative precipitation by multi-sensor blending is required as well as improving the satellite rainfall estimation algorithm.

A Highly Selective Mercury(II) Ion-Selective Membrane Sensor (고 선택성 수은(II) 이온 막 센서)

  • Ensafi, Ali A.;Meghdadi, S.;Allafchian, Ali R.
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.4
    • /
    • pp.324-330
    • /
    • 2007
  • A new ion selective PVC membrane electrode is developed as a sensor for mercury(II) ions based on bis(benzoylacetone) propylenediimine (H2(BA)2PD) as an ionophore. The electrode shows good response characteristics and displays, a linear Emf vs. log[Hg2+] response over the concentration range of 1.0×10-6 to 1.0×10-1 M Hg(II) with a Nernstian slope of 29.8±0.75 mV per decade and with a detection limit of 2.2×10-7 M Hg(II) over the pH range of 2.5-11.5. Selectivity concentrations for Hg(II) relative to a number of potential interfering ions were also investigated. The sensor is highly selective for Hg(II) ions over a large number of cations with different charge. The sensor has been found to be chemically inert showing a fast response time of 60 s and was used over a period of 3 months with a good reproducibility (S = 0.27 mV). The electrode was successfully applied to determine mercury(II) in real samples with satisfactory results.

Characteristics of a-Si:H Multilayer for Contact-type Linear Image Sensor (밀착형 1차원 영상감지소자를 위한 a-Si:H 다층막의 특성)

  • Oh, Sang-Kwang;Kim, Ki-Wan;Choi, Kyu-Man
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.5-12
    • /
    • 1992
  • We have fabricated a-Si:H multilayer for contact-type linear image sensor by means of RF glow discharge decomposition method. The ITO/i-a-Si:H/Al structure has relatively high dark current due to indium diffusion and carrier injection from both electrodes, resulting in low photocurrent to dark current. To suppress the dark current and to enhance interface electric field between ITO and i-a-Si:H film we have fabricated ITO/insulator/i-a-S:H/p-a-S:H/Al multilayer film with blocking structure. The photocurrent of ITO/$SiO_{2}(300{\AA})$/i-a-Si:H/p-a-Si:H($1500{\AA}$)/Al multilayer sensor with 5V bias voltage became saturated at about 20nA under $20{\mu}W/cm^{2}$ light intensity, while the dark current was less than 0.1nA. To increase the light generation efficiency we have adopted ITO/$SiO_{x}N_{y}(300{\AA})$/i-a-Si:H/p-a-Si:H($1500{\AA}$)/Al structure, showing photocurrent of 30nA and dark current of 0.08nA with 5V bias voltage. Also the spectral photosensitivity of the multilayer was enhanced for short wavelength visible region of 560nm, compared with that of the a-Si:H monolayer of 630nm. And its photoresponse time was about 0.3msec with the film homogeneity of 5% deviation.

  • PDF

Monitoring of itaconic acid production by a 2-dimensional fluorescence sensor

  • Jeong, Sang-Yun;Lee, Jong-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.270-273
    • /
    • 2001
  • The fluorescence sensor is utilized to monitor the complex fluorescence patterns of intra- and extracellular components in cultivation processes. Especially biogenic fluorophores such as proteins and peptides (tryptophan, phenylalanine), coenzymes (FAD, NAD(P)H) and vitamins (riboflavin, pyridoxine) within cells are detected by a fluorescence sensor. In this work a 2-dimensional fluorescence sensor has been used to monitor a production process of itaconic acid by Aspergillus terreus and the on-line monitored spectra data can be con-elated to off-line data measured by a few methods.

  • PDF

Highly Sensitive and Selective Gas Sensors Using Catalyst-Loaded SnO2 Nanowires

  • Hwang, In-Sung;Lee, Jong-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.167-171
    • /
    • 2012
  • Ag- and Pd-loaded $SnO_2$ nanowire network sensors were prepared by the growth of $SnO_2$ nanowires via thermal evaporation, the coating of slurry containing $SnO_2$ nanowires, and dropping of a droplet containing Ag or Pd nanoparticles, and subsequent heat treatment. All the pristine, Pd-loaded and Ag-loaded $SnO_2$ nanowire networks showed the selective detection of $C_2H_5OH$ with low cross-responses to CO, $H_2$, $C_3H_8$, and $NH_3$. However, the relative gas responses and gas selectivity depended closely on the catalyst loading. The loading of Pd enhanced the responses($R_a/R_g$: $R_a$: resistance in air, $R_g$: resistance in gas) to CO and $H_2$ significantly, while it slightly deteriorated the response to $C_2H_5OH$. In contrast, a 3.1-fold enhancement was observed in the response to 100 ppm $C_2H_5OH$ by loading of Ag onto $SnO_2$ nanowire networks. The role of Ag catalysts in the highly sensitive and selective detection of $C_2H_5OH$ is discussed.

$H_2$ sensor for detecting hydrogen in DI water using Pd membrane (발전기 스테이터의 냉각코일에 pinhole 발생을 검지 할 수 있는 수소센서 개발)

  • Choi, Sie-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.442-445
    • /
    • 1999
  • In this work, to detect of hydrogen in DI water in the generator area of nuclear power plants was fabricated Pd/Pt gate MISFET sensor using Pd membrane. $H_2$ permeation through Pd accounts for external mass transfer, surface adsorption and desorption, transitions to and from the bulk metal, and diffusion within the metal. The identification of pinholes in the generator area of plant is an important safety consideration, as hydrogen build-up gives rise to explosion. For this type of application the sensor needs to be isolated in DI water, accordingly, a Pd membrane was used to separate the DI water. The hydrogen in the DI water was then absorbed on the Pd thin film and diffused into the oil through the thin film. The Pd/Pt gate MISFET sensor, encapsulated by oil, will thereby detect permeated hydrogen.

  • PDF

Rapid detection of liposome by piezoresistive cantilever sensor (고감도 압저항 외팔보 센서를 이용한 Liposome의 검침)

  • Hyun, S.J.;Kim, H.S.;Kim, Y.J.;Jung, H.I.
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.156-159
    • /
    • 2005
  • Liposomes are microscopic spherical vesicles that form when lipids are hydrated and have been widely used for biochemical assay, drug delivery and molecular imaging. In particular, they are well known for artificial cell membranes to study cellular functions such as cell fusions and membrane proteins. Here, we firstly report the detection of liposomes by the highly sensitive microfabricated piezoresistive cantilever sensor chip and the phosphatidylserine recognition protein C2A which is chemically immobilized on the sensor surface. The signal created from the bending motion of piezoresistive cantilever after the liposome attachment has been monitored in real time.