• Title/Summary/Keyword: $H_{2}$ gas sensor

Search Result 292, Processing Time 0.029 seconds

Development of Assembly for Fast BOD Estimation and Its Applications (신속한 BOD 측정장치의 개발과 응용)

  • Soon, Moo-Jeong;Kim, Eun-Jeong;Jang, Seh-Yong;Hong, Daeil
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.285-291
    • /
    • 1994
  • A microbial BOD sensor for the continuous estimation of BOD was been developed by immobilizing Trichosporon cutaneum, which was immobilized between a dialysis and a gas-permeable membrane, on an oxygen electrode. The optimum pH and temperature for BOD measurement using this sensor were pH 7.0 and $32{\sim}33^{\circ}C$, respectively. The best result was obtained at 2~3ml/min flow rate in 0.1M phosphate buffer solution. A linear relationship was observed between ${\Delta}DO$ and the concentration of standard GGA solution below 60mg/l(90ppm $BOD_5$). The reproducibility was found to be within 3% for the standard solution containing glucose 30mg/l and glutamic acid 30mg/l. The output DO value of this sensor was almost constant for 30 dalys. The response time and the recovery time were about 5 and 10 min, respectively. This sensor was employed for the BOD measurement of waste pollutants and was compared with $BOD_5$ method.

  • PDF

Solvent Sensing Properties of Thin Films Based on Zinc phthalocyanine (ZnPc) Compounds (Zinc phthalocyanine(ZnPc)화합물의 이용한 유기용제 센서)

  • Kim D.H.;Kang Y.G.;Kim J.H.;Roh S.C.;Kim H.J.
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.4 s.29
    • /
    • pp.26-29
    • /
    • 2005
  • In this paper, the solvent sensing properties of the metallophthalocyanine macrocyclic compounds(ZnPc) have been deposited as thin films by the spin-coated method and evaporated methods onto alumina substrates and quartz substrates. And then the spin-coated materials of Zinc phthalocyanine solutions blended with $N,N'-diphenyl-N,N'-bis(1-naphthyl)-1,\;1-biphenyl-4,4'-diamine\;and/or\; Poly[2-methoxy-5-(2'-ethylhexyloxy)-1,4-phenylene-vinylene]$ solutions. The influences of the blended metallophthalocyanine macrocyclic compounds on the resistance have been measured and analysed in five different vapour organic compounds.

  • PDF

Fabrications of Pd/poly 3C-SiC schottky diodes for hydrogen gas sensor at high temperatures (고온 가스센서용 Pd-다결정 3C-SiC 쇼트키 다이오드 제작)

  • Ahn, Jeong-Hak;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.78-79
    • /
    • 2008
  • In this paper, poly 3C-SiC thin films were grown on $SiO_2$/Si by atmospheric pressure chemical vapor deposition (APCVD) using HMDS, $H_2$, and Ar gas at $1100^{\circ}C$ for 30 min, respectively. And then, palladium films were deposited on poly 3C-SiC by RF magnetron sputter. Thickness, uniformity, and quality of these samples were performed by SEM. Crystallinity and preferred orientationsof palladium were analyzed by XRD. And Pd/poly 3C-SiC schottky diodes were fabricated and characterized by current-voltage measurements. Its electric current density Js and barrier height voltage were measured as $2\times10^{-3}$ A/$cm^2$, 0.58 eV, respectively. And these devices operated about $350^{\circ}C$. From results, Pd/poly 3C-SiC devices are promising for high temperature hydrogen sensor and applications.

  • PDF

Gas Sensing Properties of Powder Prepared from Waste Thermoelectric Devices by Wet Reduction Process

  • So, Hyeongsub;Im, Dong-Ha;Jung, Hyunsung;Lee, Kun-Jae
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.1
    • /
    • pp.90-93
    • /
    • 2018
  • In this study, n-type $Bi_2Te_3$ in thermoelectric scrap is recovered through a wet reduction process. The recovered powder (tellurium) is grafted onto gas sensor in a new application that is not a thermoelectric device. Bismuth-rich powder is prepared by adding hydrazine when pH of the solution is brought to 13 using NaOH. The pH of the filtered solution was reduced using $HNO_3$, and then hydrazine was added to perform the re-reduction reaction. The tellurium-rich powder can be obtained through this reaction. The elemental analysis for these powders is confirmed by energy dispersive X-ray spectroscopy (EDS) analysis ; the successful separation of bismuth and tellurium is confirmed. Separated tellurium powder is mixed with DMF solvent and ethyl cellulose binder to confirm gas sensing properties. The tellurium paste was exposed in $NO_x$ atmosphere and exhibited a rapid reaction rate and recovery rate of less than 3 minutes for the gas.

The Improvement of Sensitivity Characteristics of Pd doped $SnO_2$ Nanowire Gas Sensor (Pd 도핑에 따른 $SnO_2$ 나노선 가스센서의 감도 특성 개선)

  • Kim, Yeon-Woo;Kwon, Sun-Il;Park, Seung-Beom;Lee, Seok-Jin;Jung, Tae-Hwan;Yang, Kea-Joon;Lim, Dong-Gun;Park, Jae-Hwan;Kim, Hong-Oh
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.160-161
    • /
    • 2008
  • $SnO_2$는 n형 반도체로써 3.6 eV의 큰 밴드갭을 가지는 물질로 CO와 NOx 가스에 좋은 감도를 나타내는 것으로 보고되고 있다. 문헌에 따른 일반적인 $SnO_2$ 가스센서는 후막이나 벌크형태로 제작되었다. 근래에는 가스감응체가 $SnO_2$ 나노선 형태인 가스센서가 활발한 연구 중에 있다. 본 논문에서는 기판 위에 서로 분리된 전극 패턴에 Au를 촉매로 하여 네트워크 구조로 된 $SnO_2$ 나노선이 합성되었다. 제작된 가스센서에 Pd 도핑에 따른 영향을 알아보기 위하여 1.8 mM의 Pd 용액 ($PdCl_2{\cdot}xH_2O$ 3 mg + $H_2O$ 10 ml)을 이용하여 센서에 도핑하였다. 측정 시스템에서 $NO_2$ 가스에 대한 센서의 특성을 분석한 결과 도핑하지 않은 $SnO_2$ 센서보다 20%정도의 감도가 개선되었다.

  • PDF

Fabrication and Characteristics of Photoconductive Amorphous Silicon Film for Facsimile (팩시밀리용 비정질 실리콘 광도전막의 제작 및 특성)

  • Kim, Jeong-Seob;Oh, Sang-Kwang;Kim, Ki-Wan;Lee, Wu-Il
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.6
    • /
    • pp.48-56
    • /
    • 1989
  • Contact-type linear image sensors for facsimile have been fabricated by means of rf glow discharge decomposition method of silane. The dependence of their electrical and optical properties on rf power, $SiH_4$ flow rate, ambient gas pressure, $H_2SiH_4$ ratio and substrate temperature are described. The a-Si:H monolayer demonstriated photosensitivity of 0.85 and $I_{ph}/I_d$ ratio of 100 unger 100 lux illumination. However, this monolayer has relatively high dark current due to carrier injection from both electrodes, resulting in low $I_{ph}/I_{dd}$ ratio. To suppress the dark current we have fabricated $SiO_2/i-a-Si:H/p-a-Si:H:B$ multilayer film with blocking structure. The photocurrent of this multilayer sensor with 6 V bias became saturated ar about 20nA under 10 lux illumination, while the dark current was less than 0.2 nA. Moreover, the spectral sensitivity of the multilayer film was enhanced for short wavelength visible region, compared with that of the a-Si:H monolayer. These results show that the fabricated photocon-ductive film can be used as the linear image sensor of the facsimile.

  • PDF

The Biosensor for L-Glutamine Using Tissue Slices of Wistar Rat (Wistar 쥐 조직을 이용한 L-Glutamine 바이오센서)

  • Bae, Jin Hyeon;Choe, Seong Mun;Im, Dong Jun;Kim, Wi Rak
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.3
    • /
    • pp.200-207
    • /
    • 1994
  • A biosensor for the measurement of L-glutamine has been constructed by immobilizing the slice of Wistar rat kidney and it's organelle on $NH_3$ gas-sensing electrode. The effects of pH, buffer solution, temperature and thickness of slice were investigated in order to optimize electrode response. The tissue sensor had the linearity in the range of L-glutamine concentration $8.0{\times}10^{-5}{\sim}1.0{\times}10^{-2} M$ with a slope of 53.8 mV/decade in 0.05 M phosphate buffer solution, pH 7.8 at $30^{\circ}C$, and optimum thickness of slice and response time were 30 ${\mu}m$ and 3∼5 min, respectively. The organelle sensor showed the linearity within L-glutamine concentration range of $1.2{\times}10^{-4}{\sim}5.0{\times}10^{-3} M$ with a slope of 54.0 mV/decade in 0.05 M phosphate buffer solution, pH 7.8 at $30^{\circ}C$, and response time was 6∼7 min, respectively. Thus, it is clear that the tissue and organelle sensor will be useful for L-glutamine measurements.

  • PDF

Frbrication and characteristics of NO$_{2}$ Gas sensor using the phthalocyanines (프탈로시아닌을 이용한 NO$_{2}$ 가스센서의 제작 및 특성)

  • 전춘배;박효덕;이덕동
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.7
    • /
    • pp.85-93
    • /
    • 1995
  • In this study, phthalocyanine thin films were prepared by vacuum sublimation method and investigated sensing characteristics of the films. The phthalocyannies used for the prepaation of the NO$_{x}$ sensors were metal-free Pc(H$_{2}$Pc) and metal Pc(CuPc, CoPc, PbPc). And the substrate temperatures maintained during the fomation of Pc films were varied between R.T. and 200$^{\circ]C$, and the base pressure was 5${\times}10^{6}$ torr. The relationships between NO$_{2}$ sensing properties and SEM analyses as a function of substrate temperatures during the formation of the films were investigated. Among the Pc films, PbPc film showed the best sensing characteristics. Particularlly, the PbPc films prepared at 70$^{\circ]C$ of the substrage temperature showen good sensitivity of 85% to 1ppm NO$_{2}$ gas at operating temperature 190$^{\circ]C$ and response time was about 24 seconds.

  • PDF

Quantification of Oxygen Transfer in Test Tubes by Integrated Optical Sensing

  • Wittmann, Christoph;Schutz, Verena;John, Gernot;Heinzle, Elmar
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.991-995
    • /
    • 2004
  • Immobilized sensor spots were applied for online measurement of dissolved $O_2$, in test tubes. Oxygen transport was quantified at varied shaking frequency and filling volumes. The k$_{L}$ a increased with increasing shaking frequency and decreasing filling volume. In non-baffled tubes the maximum $k_{L}a$ value was $70h^{-1}$, equivalent to a maximum $O_2$ transfer capacity of 15mMh^{-1}$. Monitoring of the hydrodynamic profile revealed that the liquid bulk rotated inside the tube with an inclined liquid surface, whereby the angle between the surface and tube wall increased with increasing shaking frequency. The $k_{L}a$ clearly correlated to the surface area. Placement of four baffles into the tubes improved the oxygen transfer up to 3-fold. The highest increase in $k_{L}a$ was observed at high filling volume and high shaking frequency. The maximum $k_{L}a$ in baffled tubes was $100 h^{-1}$.

First-principles Study of MoS2 Nanostructures with Various Adsorbates

  • Cha, Janghwan;Sung, Dongchul;Hong, Suklyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.210.2-210.2
    • /
    • 2014
  • Recently, molybdenum disulfide (MoS2) nanostructures have been investigated for applications of lithium-ion batteries, solar cell, and gas sensors. In this regard, we have studied atomic and electronic properties of MoS2 nanostructures with adsorbed atoms and molecules using density functional theory calculations. Our calculations reveal that the several atoms such as H, C, N, and F are chemically bound to several sites on the two-dimensional (2D) MoS2 surface. On the other hand, various contamination molecules such as CO, CO2, NO, NO2, and NH3 do not bind to the surface. Next, adsorption of various molecules on the one-dimensional (1D) armchair MoS2 nanoribbon is investigated. Contrary to the case of 2D MoS2 monolayer surface, some molecules (CO and NO) are bound well to the edge of the MoS2 nanoribbon. We find that the molecular states due to adsorption are located near the Fermi level, which makes the band gap narrower. Therefore, we suggest that monolayer MoS2 nanoribbons be used as the gas sensors or detectors.

  • PDF