• Title/Summary/Keyword: $Fe^{3+}$ detection

Search Result 149, Processing Time 0.024 seconds

Flow Injection Spectrophotometric Determination of Cobalt with 2-(5-Bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)aniline (2-(5-브로모-2-피리딜아조)-5-(N-프로필-N-슬포프로필아미노)아닐린을 사용하여 흐름주입법에 의한 코발트의 분광광도법적 정량)

  • Kang, Sam Woo;Kim, In Yong;Han, Hong Seok;Lee, Seung Seok
    • Analytical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.57-63
    • /
    • 1993
  • Spectrophotometric determination of cobalt by flow injection method is described. 2-(5-Bromo-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino) aniline rapidly forms a water-soluble complex with cobalt in $NH_3-NH_4Cl$ buffer solution at pH 10.5. The absorption maxima of this complex is at 545 nm with molar absorptivity of $58000L\;mol^{-1}\;cm^{-1}$. The calibration curve of cobalt is linear over the range of 0.1 to 0.6ppm and the detection limit is 25ppb. The relative standard deviation is ${\pm}0.72%$ for 0.5ppm and the sampling rate is $60samples\;hr^{-1}$. The interfering effect of some cations and anions was investigated. Ni(II), Cu(II), Fe(III) and $CN^-$ interfered severely. The interfering effect of these matallic ions could be decreased by adding $1.0{\times}10^{-3}M$ EDTA solution to the carrier stream.

  • PDF

The Development of Continuous Flow Method Through Microwave Oven for the Analysis of Metal Oxides in Water by ICP-AES (ICP-AES에 의한 수중의 금속 산화물 직접분석을 위한 연속흐름 Microwave 용해장치 개발 연구)

  • Kim, Yeon Du;Lee, Gye Ho;Kim, Hyeong Seung;Kim, Dong Su;Park, Gwang Gyu
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.8
    • /
    • pp.576-584
    • /
    • 1994
  • The method described offers rapid and efficient sample preparation using on-line microwave digestion of metal oxides in water sample with direct elemental detection by ICP-AES. The open tubing digestion system(OTD) and the restraint tubing digestion system(RTD) for flow injection(FI) were designed and tested to find the optimum conditions. Comparison of OTD and RTD indicated that RTD was 3 times faster on the digestion time, and 10 times higher on sample mass. Finally, the results of RTD agree well with those by conventional microwave open vessel in all cases and show good precision; Fe and Cu show good with about 5% of RSD, while Zn and Co more or less than 10% RSD.

  • PDF

The Optimization and Verification of an Analytical Method for Sodium Iron Chlorophyllin in Foods Using HPLC and LC/MS (식품 중 철클로로필린나트륨의 HPLC 및 LC/MS 최적 분석법과 타당성 검증)

  • Chong, Hee Sun;Park, Yeong Ju;Kim, Eun Gyeom;Park, Yea Lim;Kim, Jin Mi;Yamaguchi, Tokutaro;Lee, Chan;Suh, Hee-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.148-157
    • /
    • 2019
  • An optimized analytical method for sodium iron chloriphyllin in foods was established and verified by using high performance liquid chromatography with attached diode array detection. An Inertsil ODS-2 column and methanol-water (80:20 containing 1% acetate) as a mobile phase were employed. The limit of detection and quantitation of sodium iron chloriphyllin were 0.1 and 0.3 mg/kg, respectively, and the linearity of calibration curve was excellent ($R^2=0.9999$). The accuracy and precision were 93.9~104.95% and 2.0~7.7% in both inter-day and intra-day tests. Recoveries for candy and salad dressing were ranged between 93 and 104% (relative standard deviation, (RSD) 0.3~4.3%), and between 83 and 115% (RSD 1.2~2.0%), respectively. Liquid chromatography mass spectrometry was used to verify the main components of sodium iron chlorophyllin which were Fe-isochlorin e4 and Fe-chlorin e4.

Detection of Heavy Metal Ions in Aqueous Solution Using Direct Dye Chemosensors

  • Heo, Eun-Yeong;Ko, Young-Il;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.21 no.5
    • /
    • pp.51-57
    • /
    • 2009
  • Since heavy metal pollution is a significant global environmental problem and very dangerous to human health, the improved methods for detecting heavy metals are required recently. Colorimetric chemosensors are now considered as one of the most effective analytical method used in the environment monitoring. New direct dyes having the function of colorimetric chemosensors were synthesized. When metal ions such as $Al^{3+}$, $Ca^{2+}$, $Cd^{2+}$, $Cr^{3+}$, $Cu^{2+}$, $Fe^{2+}$, $Fe^{3+}$, $Hg^{2+}$, $Li^+$, $Mg^{2+}$, $Na^+$, $Ni^{2+}$, $Pb^{2+}$ and $Zn^{2+}$ were added each solution of new direct dyes, the color of solution was changed and can be easily detected with naked eyes without expensive experimental equipment such as atomic absorption spectrometer (AAS) or inductively coupled plasma?mass spectrometer (ICP-MS). The new benzidine analogues were diazotized and reacted with couplers such as H-acid, J-acid, Chromotropic acid, Nevill-winther acid and gamma acid to synthesize new direct dyes. The structures of the new direct dyes were confirmed by high resolution mass spectrometer (FAB ionization) and evaluated with UV-Vis spectroscopy. The UV-VIS spectroscopy was measured for the dye solutions by adding various concentrations of metal ions. It was observed that the absorbance in UV-Vis spectra was changed as the heavy metal ions were added.

The Characteristics of Thick-film ZnO Sensor for CO Gas Detection (CO 검지용 후막형 ZnO 센서의 특성)

  • Kim, Bong-Hee;Kim, Sang-Wook;Park, Geun-Young;Yi, Seung-Hwan;Sung, Yung-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.245-248
    • /
    • 1991
  • Recently, oxide semiconductor gas sensors consisted of n-type semiconductor materials such as $SnO_2$, ZnO and $Fe_2O_3$ have been widely used to detect reducing gases. In this paper, we made the thick-film ZnO gas sensors with $PdCl_2$ as a catalyst and investigated the sensitivity to CO gas. In the thick-film Zno sensor, the highest sensitivity was shown in the sensor with 1wt.% of $PdCl_2$ which was sintered for 1 hour at $700^{\circ}C$ and operated at $300^{\circ}C$.

  • PDF

A comparison between thick-film ZnO and $SnO_2$ gas sensors for CO gas detection (CO 검지용 후막형 ZnO와 $SnO_2$ 가스센서의 비교)

  • Kim, Bong-Hee;Yi, Seung-Hwan;Kang, Hee-Bok;Sung, Yung-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.209-212
    • /
    • 1991
  • Recently, oxide semiconductor gas sensors consisted of n-type semiconductor materials such as $SnO_2$, ZnO and $Fe_2O_3$ have been widely used to detect reducing gases. The advantage of thick-film technology include the possibility of mass-production and automation, that of integrating the sensing element in a hybrid circuit and that of fuctional trimming of the sensor and/or the circuit. which would enable really interchangeable transducers to be prepared. In this paper, we made ZnO and $SnO_2$ gas sensors and investigated the sensitivity to CO gas. Therefore, we compared a ZnO gas sensor with a $SnO_2$ gas sensor.

  • PDF

Changes in Proteome Following Exposure to Di (2-ethylhexyl) Phthalate in Chironomus riparius (Diptera: Chironomidae)

  • Kwak, Inn-Sil;Lee, Wonchoel
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.4
    • /
    • pp.532-536
    • /
    • 2004
  • Due to the fourth-instar larvae of C. riparius have a sensitive to ecdysteroidal molting hormones for the life cycle developments, accordingly the emerged adult affected corresponding to larval phase's environments. The emerged female from larval phase exposure to DEHP observed a fact body and clumsy fling behavior in females. The body volume of treated female groups was clearly larger than that of control fe- males. In the 2D/E gel 1108 protein spots were identified. The visualized protein spots allowed extraction of 27 protein spots differed more than 3 fold in DEHP treated animals, which was approximately 2.4% of the total protein spots. In this view, the body volume (or morphological characters) was well observed and detected faster than physiological detection for various EDCs. In this study, the body volume as a detecting po-int for EDCs suggested a bio-marker in individual levels.

Determination of Trace Metals in Waters by FAAS after Enrichment as Metal-HMDTC Complexes Using Solid Phase Extraction

  • Tokalioglu, Serife;Kartal, Senol;Elci, Latif
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.5
    • /
    • pp.693-698
    • /
    • 2002
  • A method has been described for the determination of Cu(Ⅱ), Pb(Ⅱ), Ni(Ⅱ), Cd(Ⅱ), Mn(Ⅱ) and Fe(Ⅲ) by flame atomic absorption spectrometry (FAAS) after preconcentration on Amberlite XAD-16 resin, using hexamethyleneammonium-hexamethylenedithiocarbamate (HMA-HMDTC) as a chelating agent, and NH3/NH4Cl buffer solution (pH 9). Influences of various analytical parameters such as pH, concentration of nitric acid, amount of analytes, diverse ions and sample volume were investigated. The relative standard deviation (RSD) and the detection limit (LOD) were found in the range of 0.8-2.9% and 0.006-0.277 ㎍/mL,respectively. Recoveries obtained by the column method were quantitative ( >95%) at optimum conditions.The method was applied to the determination of some metal ions in seawater and wastewater samples. A high preconcentration factor (about 150 for seawater and 75 for wastewater samples) and simplicity are the main advantages of this suggested method.

Sorbent Extraction of Some Metal Ions on a Gas Chromatographic Stationary Phase Prior to Their Flame Atomic Absorption Determinations

  • Soylak, M.;Saracoglu, S.;Elci, L.
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.5
    • /
    • pp.555-558
    • /
    • 2003
  • An enrichment/separation system for atomic absorption spectrometric determinations of Cu(Ⅱ), Fe(Ⅲ), Ni(Ⅱ) and Co(Ⅱ) has been established. The procedure is based on the adsorption of the analytes as calmagite chelates on Chromosorb-102. The effects of some parameters including pH, amount of ligand, salt matrix, flow rates of sample and eluent solutions were investigated. Under optimized conditions, the relative standard deviation of the combined method of sample treatment, preconcentration and determination with FAAS (N=5) is generally lower than 5%. The limit of detection (3σ) was between 6.0-112.9 ㎍/L. The results were used for preconcentration of analytes from some sodium and ammonium salt.

Basic Properties of Stones used for Cooking Utensils and Their Leaching Characteristics for Heavy Metal Elements (조리용구용 석재의 기초 특성과 중금속 원소의 용출 특성)

  • 진호일;김신자;김복란;민경원
    • Economic and Environmental Geology
    • /
    • v.35 no.4
    • /
    • pp.347-353
    • /
    • 2002
  • Dominant rock types of stones used presently for cooking utensils in Korea are pyroxenite, breccia and biotite diorite. Pyroxenite and biotite diorite relatively abundant in mafic minerals have higher specific gravities of 3.0 than breccia of 2.5. Breccia shows the highest absorption (2.9%) among three stones used as cooking utensils and pH value of three stone types shows the alkaline range of 9.7 to 9.9. Among the studied stones used for cooking utensils, biotite diorite is the most durable against abrasion and has the highest strength and therefore, it is expected to be used effectively for the longest time except for other specific causes. Heavy metals such as Cu, Pb, Co, Cr and Ni were leached lower than their detection limit (0.1 ppm) regardless of reaction time and initial pH value of solution. But the leached contents of Fe are various with rock types and leaching conditions and those by acidic solution are generally 1.8 to 31 times higher than those by neutral solution. Breccia and biotite diorite show the highest leached content of Fe in cases of neutral and acidic solutions, respectively. Standard criteria of leached heavy metals and macrominerals should be studied thoroughly to utilize stones for cooking utensils of high quality which are harmless to the human body. Also it is required to examine mon detailed abiochemical properties of various stone types used for cooking utensils.