• Title/Summary/Keyword: $Fe^{3+}$ detection

Search Result 149, Processing Time 0.027 seconds

Preparation and Characterization of Photoluminescent Graphene Quantum Dots from Watermelon Rind Waste for the Detection of Ferric Ions and Cellular Bio-Imaging Applications

  • Chatchai Rodwihok;Tran Van Tam;Won Mook Choi;Mayulee Suwannakaew;Sang Woon Woo;Duangmanee Wongratanaphisan;Han S. Kim
    • Nanomaterials
    • /
    • v.12 no.4
    • /
    • pp.702-714
    • /
    • 2022
  • Graphene quantum dots (GQDs) were synthesized using watermelon rind waste as a photoluminescent (PL) agent for ferric ion (Fe3+) detection and in vitro cellular bio-imaging. A green and simple one-pot hydrothermal technique was employed to prepare the GQDs. Their crystalline structures corresponded to the lattice fringe of graphene, possessing amide, hydroxyl, and carboxyl functional groups. The GQDs exhibited a relatively high quantum yield of approximately 37%. Prominent blue emission under UV excitation and highly selective PL quenching for Fe3+ were observed. Furthermore, Fe3+ could be detected at concentrations as low as 0.28 µM (limit of detection), allowing for high sensitivity toward Fe3+ detection in tap and drinking water samples. In the bio-imaging experiment, the GQDs exhibited a low cytotoxicity for the HeLa cells, and they were clearly illuminated at an excitation wavelength of 405 nm. These results can serve as the basis for developing an environment-friendly, simple, and cost-effective approach of using food waste by converting them into photoluminescent nanomaterials for the detection of metal ions in field water samples and biological cellular studies.

Nitric Oxide Detection of Fe(DTC)3-hybrizided CdSe Quantum Dots Via Fluorescence Energy Transfer

  • Chang-Yeoul, Kim
    • Journal of Powder Materials
    • /
    • v.29 no.6
    • /
    • pp.453-458
    • /
    • 2022
  • We successfully synthesize water-dispersible CTAB-capped CdSe@ZnS quantum dots with the crystal size of the CdSe quantum dots controlled from green to orange colors. The quenching effect of Fe(DTC)3 is very efficient to turn off the emission light of quantum dots at four molar ratios of the CdSe quantum dots, that is, the effective covering the surface of quantum dots with Fe(DTC)3. However, the reaction with Fe(DTC)3 for more than 24 h is required to completely realize the quenching effect. The highly quenched quantum dots efficiently detect nitric oxide at nano-molar concentration of 110nM of NO with 34% of recovery of emission light intensity. We suggest that Fe(DTC)3-hybridized CdSe@ZnS quantum dots are an excellent fluorescence resonance energy transfer probe for the detection of nitric oxide in biological systems.

Anodic Stripping Voltammetric Detection of Arsenic(III) at Platinum-Iron(III) Nanoparticle Modified Carbon Nanotube on Glassy Carbon Electrode

  • Shin, Seung-Hyun;Hong, Hun-Gi
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3077-3083
    • /
    • 2010
  • The electrochemical detection of As(III) was investigated on a platinum-iron(III) nanoparticles modified multiwalled carbon nanotube on glassy carbon electrode(nanoPt-Fe(III)/MWCNT/GCE) in 0.1 M $H_2SO_4$. The nanoPt-Fe(III)/MWCNT/GCE was prepared via continuous potential cycling in the range from -0.8 to 0.7 V (vs. Ag/AgCl), in 0.1 M KCl solution containing 0.9 mM $K_2PtCl_6$ and 0.6 mM $FeCl_3$. The Pt nanoparticles and iron oxide were co-electrodeposited into the MWCNT-Nafion composite film on GCE. The resulting electrode was examined by cyclic voltammetry (CV), scanning electron microscopy (SEM), and anodic stripping voltammetry (ASV). For the detection of As(III), the nanoPt-Fe(III)/MWCNT/GCE showed low detection limit of 10 nM (0.75 ppb) and high sensitivity of $4.76\;{\mu}A{\mu}M^{-1}$, while the World Health Organization's guideline value of arsenic for drinking water is 10 ppb. It is worth to note that the electrode presents no interference from copper ion, which is the most serious interfering species in arsenic detection.

Robust and Efficient 3D Model of an Electromagnetic Induction (EMI) Sensor

  • Antoun, Chafic Abu;Perriard, Yves
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.325-330
    • /
    • 2014
  • Eddy current induction is used in a wide range of electronic devices, for example in detection sensors. Due to the advances in computer hardware and software, the need for 3D computation and system comprehension is a requirement to develop and optimize such devices nowadays. Pure theoretical models are mostly limited to special cases. On the other hand, the classical use of commercial Finite Element (FE) electromagnetic 3D models is not computationally efficient and lacks modeling flexibility or robustness. The proposed approach focuses on: (1) implementing theoretical formulations in 3D (FE) model of a detection device as well as (2) an automatic Volumetric Estimation Method (VEM) developed to selectively model the target finite elements. Due to these two approaches, this model is suitable for parametric studies and optimization of the number, location, shape, and size of PCB receivers in order to get the desired target discrimination information preserving high accuracy with tenfold reduction in computation time compared to commercial FE software.

Development and Characterization of High Frequency Ultrasonic Transducer Using PVDF and P(VDF-TrFE) (PVDF 및 P(VDF-TrFE)를 이용한 고주파수 수침용 초음파 탐촉자 개발 및 평가)

  • Kim, Ki-Bok;Kim, Byoung-Geuk;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • The high frequency ultrasonic transducers using polyvinyliden fluoride(PVDF) and polyvinylidene fluoride trifluorethyylene(P(VDF-TrFE)) were developed. The characteristics of fabricated high frequency ultrasonic transducer such as beam diameter, high frequency ultrasonic detection field and amplitude of the first pulse echo signal from the test target in the water were analyzed. The high frequency ultrasonic detection field was affected by the length of coaxial cable between high frequency transducer and ultrasonic pulser/receiver. As the size of the test target increased, the high frequency detection field decreased and the amplitude of a reflection signal increased. The peak amplitude of the first pulse echo signal of P(VDF-TrFE) transducer was higher than that of PVDF transducer. The high frequency ultrasonic detection field of PVDF transducer was wider than that of P(VDF-TrFE) transducer. With C-scan testing, the developed high frequency ultrasonic transducer could detect the 30 to $100{\mu}m$ of hydrogen induced crack of steel specimen by C-scan testing.

Assessment of sensitivity-based FE model updating technique for damage detection in large space structures

  • Razavi, Mojtaba;Hadidi, Ali
    • Structural Monitoring and Maintenance
    • /
    • v.7 no.3
    • /
    • pp.261-281
    • /
    • 2020
  • Civil structures may experience progressive deterioration and damage under environmental and operational conditions over their service life. Finite element (FE) model updating method is one of the most important approaches for damage identification in structures due to its capabilities in structural health monitoring. Although various damage detection approaches have been investigated on structures, there are limited studies on large-sized space structures. Thus, this paper aims to investigate the applicability and efficiency of sensitivity-based FE model updating framework for damage identification in large space structures from a distinct point of view. This framework facilitates modeling and model updating in large and geometric complicated space structures. Considering sensitivity-based FE model updating and vibration measurements, the discrepancy between acceleration response data in real damaged structure and hypothetical damaged structure have been minimized through adjusting the updating parameters. The feasibility and efficiency of the above-mentioned approach for damage identification has finally been demonstrated with two numerical examples: a flat double layer grid and a double layer diamatic dome. According to the results, this method can detect, localize, and quantify damages in large-scaled space structures very accurately which is robust to noisy data. Also, requiring a remarkably small number of iterations to converge, typically less than four, demonstrates the computational efficiency of this method.

Accuracy of maximal expiratory flow-volume curve curvilinearity and fractional exhaled nitric oxide for detection of children with atopic asthma

  • Park, Sang Hoo;Im, Min Ji;Eom, Sang-Yong;Hahn, Youn-Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.9
    • /
    • pp.290-295
    • /
    • 2017
  • Purpose: Airway pathology in children with atopic asthma can be reflected by the concave shape of the maximal expiratory flow-volume (MEFV) curve and high fractional exhaled nitric oxide (FeNO) values. We evaluated the capacity of the curvilinearity of the MEFV curve, FeNO, and their combination to distinguish subjects with atopic asthma from healthy individuals. Methods: FeNO and angle ${\beta}$, which characterizes the general configuration of the MEFV curve, were determined in 119 steroid-naïve individuals with atopic asthma aged 8 to 16 years, and in 92 age-matched healthy controls. Receiver operating characteristic (ROC) curve analyses were performed to determine the cutoff points of FeNO and angle ${\beta}$ that provided the best combination of sensitivity and specificity for asthma detection. Results: Asthmatic patients had a significantly smaller angle ${\beta}$ and higher FeNO compared with healthy controls (both, P<0.001). For asthma detection, the best cutoff values of angle ${\beta}$ and FeNO were observed at $189.3^{\circ}$ and 22 parts per billion, respectively. The area under the ROC curve for the combination of angle ${\beta}$ and FeNO improved to 0.91 (95% confidence interval [CI], 0.87-0.95) from 0.80 (95% CI, 0.75-0.86; P<0.001) for angle ${\beta}$ alone and 0.86 (95% CI, 0.82-0.91; P=0.002) for FeNO alone. In addition, the combination enhanced sensitivity with no significant decrease in specificity. Conclusion: These data suggest that the combined use of the curvilinearity of the MEFV curve and FeNO is a useful tool to differentiate between children with and without atopic asthma.

Soft Ionization of Metallo-Mefenamic Using Electrospray Ionization Mass Spectrometry

  • Abdelhamid, Hani Nasser;Wu, Hui-Fen
    • Mass Spectrometry Letters
    • /
    • v.6 no.2
    • /
    • pp.43-47
    • /
    • 2015
  • Detection of mefenamic acid (M, non-steroidal anti-inflammatory drug, NSAIDs) and its metallodrug was investigated using electrospray ionization mass spectrometry (ESI-MS) and fluorescence spectroscopy. ESI-MS data (500 µL, 1×10-3 M) revealed high detection sensitivity for the drug and metallodrug. ESI-MS spectra revealed peaks at 242, 580, and 777 Da corresponding to [M+H]+, [63Cu(M-H)2(H2O)2+H]+, and [56Fe(M-H)3+H]+, respectively. The metal:mefenamic ratios of ESIMS spectra are in complete agreement with the fluorescence spectroscopy results (1:2 for Cu(II) and 1:3 for Fe(III)). ESI is a soft ionization technique that can be used on labile metallo-mefenamic acids and is promising for the detection of these species in environmental samples and biological fluids.

The Application of Ion Chromatographic Method for Bioavailability and Stability Test of Iron Preparations

  • Kim, Young-Ok;Chung, Hye-Joo;Kong, Hak-Soo;Choi, Dong-Woong;Cho, Dae-Hyun
    • Archives of Pharmacal Research
    • /
    • v.22 no.3
    • /
    • pp.288-293
    • /
    • 1999
  • Postabsorptive serum iron level was determined after oral administration of the compounds to human. In serum and whole blood, $Fe^{3+}$ was measured by ion chromatography (IC) using a pyridine-2,6-dicarboxylic acid (PDCA) as an eluent. The serum sample solutions were pretreated with I N HCI and 50% TCA. The whole blood sample solutions were treated with 3 N HCI for 30 min at $125^{\circ}C$. The limit of detection (LOD) of the IC technique is $0.2 {\mu}M$ for$Fe^{2+}$and 0.1 $\mu$M for $Fe^{3+}$. The area under concentration (AUC) can be obtained by the above analytical condition. In addition, to compare the stability of $Fe^{2+}$ to that of $Fe^{3+}$ in pharamaceutical preparations, accelerated stability test was carried out. After storing the samples under $40^{\circ}C$, 75%RH in light-resistant container for various time intervals, the contents of iron of different valencies were determined separately by the IC technique and the change and/or the interchange of among those iron species in preparations was investigated. Iron raw materials are stable, but $Fe^{2+}$ in$Fe^{3+}$ source materials was slightly converted to $Fe^{3+}$ by oxidation. $Fe^{2+}$ in$Fe^{3+}$ source raw materials and $Fe^{3+}$ in $Fe^{2+}$ raw materials are determined as impurities. Therefore, IC technique is found to be an appropriate method for comparative evaluation of dissimilar bioavailability of $Fe^{2+}$ and $Fe^{3+}$, stability of $Fe^{2+}$ and $Fe^{3+}$ raw materials and preparations.

  • PDF

A New Fe (III)-Selective Membrane Electrode Based on Fe (II) Phthalocyanine

  • Ozer, Tugba;Isildak, Ibrahim
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.321-328
    • /
    • 2019
  • A new miniaturized all solid-state contact Fe (III)-selective PVC membrane electrode based on Fe (II) phthalocyanine as a neutral carrier was described. The effects of the membrane composition and foreign ions on the electrode performance was investigated. The best performance was obtained with a membrane containing 32% poly (vinyl chloride), 64% dioctylsebacate, 3% Fe (II) phthalocyanine, and 1% potassium tetrakis (p-chlorophenyl) borate. The electrode showed near Nernstian response of $26.04{\pm}0.95mV/decade$ over the wide linear concentration range $1.0{\times}10^{-6}$ to $1.0{\times}10^{-1}M$, and a very low limit of detection $1.8{\pm}0.5{\times}10^{-7}M$. The potentiometric response of the developed electrode was independent at pH 3.5-5.7. The lifetime of the electrode was approximately 3 months and the response time was very short (< 7 s). It exhibited excellent selectivity towards Fe (III) over various cations. The miniaturized all solid-state contact Fe (III)-selective membrane electrode was successfully applied as an indicator electrode for the potentiometric titration of $1.0{\times}10^{-3}M$ Fe (III) ions with a $1.0{\times}10^{-2}M$ EDTA and the direct determination of Fe (III) ions in real water samples.