• 제목/요약/키워드: $DO_3$ phase

검색결과 890건 처리시간 0.036초

Current-Steered Active Balun with Phase Correction

  • Park, Ji An;Jin, Ho Jeong;Cho, Choon Sik
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권6호
    • /
    • pp.629-633
    • /
    • 2015
  • An active balun using current steering for phase correction is presented. The proposed active balun is constructed with two different unit balun structures based on current steering to reduce phase and amplitude errors. This type of topology can be compared with the conventional phase and amplitude correction techniques which do not incorporate the current steering. Designed and fabricated active balun in $0.18{\mu}m$ CMOS process operates over 0.95 - 1.45 GHz band, showing input reflection coefficient under -15 dB, phase error of $11^{\circ}$ and gain error of 0.5 dB. Gain is measured to be 0.3 dB maximum and power consumption of 7.2 mW is measured.

영상성분을 고려한 DVR 기기 해석 (The Analysis of Zero Sequence Components in Dynamic Voltage Restorer System)

  • 정일엽;박상영;원동준;문승일;박종근;한병문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권4호
    • /
    • pp.169-174
    • /
    • 2002
  • The magnitude and phase of the compensating voltage in Dynamic Voltage Restorer (DVR) system depend on the voltage sag in the phases affected by the fault and on the influence of the zero sequence components. If the delta connection of the transformer is used, the zero sequence components do not appear on the load side. But nowadays, Y connected transformers with grounded neutral, that is 3-phase 4-wire system, are usually used. Therefore the zero-sequence components are occurred during faults. The zero-sequence components result in the high insulation costs and the asymmetry of the phase and magnitude of the terminal voltages. In this paper 3 phase 4 wire distribution system and 3 phase 3 wire system are analyzed and characteristics of voltage sag are presented. And this paper proposes the method that can mitigate the zero-sequence under the unbalance faults causing voltage sage and phase angle iumps.

Three Shunt 저항을 이용한 3상 인버터의 상전류 측정방법 (Phase Current Sensing Method Using Three Shunt Resistor for Three Phase Inverter)

  • 김도윤;이용석;문정송;이택기;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.235-236
    • /
    • 2011
  • 본 논문에서는 세 개의 Shunt 저항을 이용하여 3상 인버터의 상전류를 검출하였다. Shunt 저항을 이용할 경우 전류 검출이 불가능한 제한 영역이 발생한다. 이러한 제한영역을 보상하기 위해 제한영역에 대하여 분석하였으며, 제한 영역은 추가적인 전류 추정방법을 이용하여 보상하였다. 이를 시뮬레이션을 통하여 검증하였다.

  • PDF

Design and Operational Test of 22.9kV, 30m, 3phase HTS Cable Cooling System

  • Kim Do-Hyung;Kim Choon-Dong;Park In-Son;Jang Hyun-Man;Lee Su-Kil
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권2호
    • /
    • pp.46-49
    • /
    • 2006
  • The 30m, 3phase, 22.9kV HTS (High Temperature Superconducting) power cable system was produced by LS Cable Ltd. The project aims for a commercial HTS cable. The designing, the manufacturing and the initial operating of HTS cable system were completed by 2004. Then, we have performed a long term operational test since February, 2005. This paper mainly reports the result of the HTS cable cooling operation.

W-Ni-Fe 중합금의 기계적 특성에 미치는 Fe7W6상(μ-phase)의 영향 (Effect of Fe7W6 Phase (μ-phase) on Mechanical Properties of W-Ni-Fe Heavy Alloy)

  • 전용진;김세훈;김영도
    • 대한금속재료학회지
    • /
    • 제49권9호
    • /
    • pp.720-725
    • /
    • 2011
  • W-Ni-Fe heavy alloys have been used in various fields, such as kinetic energy penetrators and radiation shielding materials, due to their high density and good mechanical properties. In this study, the sintering of W-Ni-Fe alloys with various Ni/Fe ratios was demonstrated to improve the mechanical properties and penetration capabilities of heavy alloys by formation of interfacial phase. The microstructural changes and the mechanical properties of the W-Ni-Fe alloys after liquid-phase sintering were investigated. The Vickers hardness and tensile strength of the 95W1.3Ni3.7Fe sample, which had coated W grains by $Fe_7W_6$ phase (${\mu}$-phase), were 450 Hv and 1560 MPa, respectively. As a result, enhancement of the mechanical properties was considered to have uniformly generated ${\mu}$-phase around W grains.

고온초전도체를 이용한 가지 형태 3 dB 방향성 결합기 설계 및 특성해석 (Design and Characterization of 3 dB Branch Type Directional Couplers using High-Tc Superconductors)

  • 정동철;최명호
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.116-119
    • /
    • 2010
  • In this work, we presented the characterization of 3 dB branch type directional couplers by using High-Tc superconducting thin films. To do this, we deposited YBCO superconducting thin films on MgO substrates by using rf-magnetron sputtering techniques. The designed center frequency was 408 MHz and the designed passband was 20 MHz. Also we designed 3 dB Power difference and $90^{\circ}$ of phase difference between port 3 and port 4. The even and odd mode analysis were used to characterize our directional couplers and em Sonnet (full wave analysis program) was utilized to the optimum design. We reported experimental results, including a center frequency, passband, half power characteristics and phase differences. We confirmed that experimental results were in good agreements with characterization by using full wave analysis program.

단상 전원에 접속된 3상 유도전동기의 권선전류 분석 (Analysis of winding currents for three phase induction motor connected to single phase supply)

  • 김도진;강상수;강남호;좌종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.824-825
    • /
    • 2008
  • This paper analyzes the stator winding currents of a three phase induction motor which is connected to the single phase supply. Two stator configurations, Steinmetz connection and modified Steinmetz connection, are respectively employed. In each case, the phase converter reactance at starting is determined using the condition of minimum voltage unbalance factor. By using this reactance, the stator winding currents of each connection are computed and compared with the results of three phase balanced operation.

  • PDF

파형분석에의한 영월지진의 특성 (Characteristics of the Yeongwol Earthquake based on the phase analysis)

  • 김우한
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.67-76
    • /
    • 1997
  • The seismic records of the main shock and two after shocks of the Yeongwol Earthquake are studied based on the phsase analysis. The travel time curves with 12 different possible phases are constructed to analysis the phases of the records. which were provided by KIGAM seismic network. The results of phase analysis show that 1) The main shock (Ms=4.5) shows clear Pn phase but two after shocks (Ms=4 and Ms=2.5) do not show Pn phase. 2) The Pg or PmP phases look as first arrival phase in the after shock records whose edicental distance is smaller or larger than 150 km. 3) It is very difficult to identity the phases related to the Conrad discontinuity even if the Conrad discontiuity arrival exists. 4) The record of GRE station located outside of the Kueongsan Basin shows different arrival time of Pn phase, P-S duration time and frequency compared with those of the other stations located within the Kyeongsan Basin.

  • PDF

경기도 내 대기 중 다이옥신 분포 특성에 관한 연구 (Atmospheric Distribution of PCDD/F Concentrations in Gyeonggi-do, South Korea)

  • 허종원;민윤기;김동기;최일우;김종수;송일석;이강웅
    • 한국대기환경학회지
    • /
    • 제31권6호
    • /
    • pp.548-561
    • /
    • 2015
  • Atmospheric concentrations of polychlorinated dibezo-p-dioxins and furans (PCDD/Fs) were investigated at urban-residential (Group I: Suwon, Guri and Goyang), industrial (Group II: Ansan, Siheung and Bucheon), urban-rural mixed (Group III: Yangju, Pocheon and Dongducheon) and rural regions (Group IV: Yangpyeong) in Gyeonggi-do from February 2012 to November 2012 quarterly. The concentrations of PCDD/Fs ranged from 0.018 to $0.109pgTEQm^{-3}$ in Group I (mean value: $0.061pgTEQm^{-3}$), 0.059 to $0.367pgTEQm^{-3}$ in Group II (mean value: $0.179pgTEQm^{-3}$), 0.072 to $0.836pgTEQm^{-3}$ in Group III (mean value: $0.334pgTEQm^{-3}$) and 0.014 to $0.066pgTEQm^{-3}$ in Group IV (mean value: $0.034pgTEQm^{-3}$), respectively. In spite of the less PCDD/F emission sources than Group II (industrial regions), the level of PCDD/Fs in urban-rural mixed area showed the highest values with high fluctuation. It's likely that the Group III was affected by fugitive emissions such like biomass burning and unregulated open burning. The mean contribution of particle phase to total PCDD/F concentration was above 83% because most of PCDD/F congeners were partitioned into particle phase. We evaluated their gas-to-particles equilibriums with the regression between the particle-gas partition coefficient, $K_P(m^3{\mu}g^{-1})$ and corresponding subcooled liquid vapor pressure ($P_L$). The logarithm-$K_P$ of PCDD/Fs was poorly correlated with $P_L$ at low ambient temperature (below $10^{\circ}C$) and the slope (m) values for log-log plots of the $K_P$ vs. $P_L$ was steeper in the Group 2 and Group 3 than residential area. It implies that the slope values were likely influenced by both the direct emission source of PCDD/Fs and ambient temperature.

Reconstruction of Wavefront Aberration of 100-TW Ti:sapphire Laser Pulse Using Phase Retrieval Method

  • Jeong, Tae-Moon;Kim, Chul-Min;Ko, Do-Kyeong;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.186-191
    • /
    • 2008
  • A phase retrieval method using an error reduction algorithm is developed for reconstructing a wavefront aberration of an 100-TW Ti:sapphire laser pulse from the measurement of a focal spot. The phase retrieval method can successfully reconstruct a wavefront aberration of a 100-TW Ti:sapphire laser pulse, and the reconstructed wavefront aberration shows a good agreement with the wavefront aberration measured with a wavefront sensor. The effect of the dynamic range and the intensity noise on the reconstruction is also investigated in reconstructing a wavefront aberration of an 100-TW Ti:sapphire laser pulse.