• 제목/요약/키워드: $Cu^{2+}$ detection

검색결과 188건 처리시간 0.021초

Ion-Imprinted Polymers Modified Sensor for Electrochemical Detection of Cu2+

  • An, Zhuolin;Liu, Weifeng;Liang, Qi;Yan, Guang;Qin, Lei;Chen, Lin;Wang, Meiling;Yang, Yongzhen;Liu, Xuguang
    • Nano
    • /
    • 제13권12호
    • /
    • pp.1850140.1-1850140.9
    • /
    • 2018
  • An electrochemical sensor ($Cu^{2+}$-IIPs/GCE) was developed for detection of $Cu^{2+}$ in water. $Cu^{2+}$-IIPs/GCE was prepared by dispersing $Cu^{2+}$ imprinted polymers ($Cu^{2+}$-IIPs) on a preprocessed glassy carbon electrode. $Cu^{2+}$-IIPs were synthesized on the surface of modified carbon spheres by ion imprinting technology. The electrochemical performance of $Cu^{2+}$-IIPs/GCE was evaluated by differential pulse voltammetry method. The response of $Cu^{2+}$-IIPs/GCE to $Cu^{2+}$ was linear in $1.0{\times}10^{-5}mol/L$ to $1.0{\times}10^{-3}mol/L$. The detection limit was $5.99{\times}10^{-6}mol/L$ (S=N = 3). The current response value of $Cu^{2+}$-IIPs/GCE was 2.14 times that of the nonimprinted electrode. These results suggest that $Cu^{2+}$-IIPs/GCE can detect the concentration of $Cu^{2+}$ in water, providing a new way for heavy metal ions adsorption and testing.

A Coumarin-based Fluorescent Sensor for Selective Detection of Copper (II)

  • Wang, Jian-Hong;Guo, Xin-Ling;Hou, Xu-Feng;Zhao, Hui-Jun;Luo, Zhao-Yang;Zhao, Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권8호
    • /
    • pp.2400-2402
    • /
    • 2014
  • Cu (II) detection is of great importance owing to its significant function in various biological processes. In this report, we developed a novel coumarin-based chemosensor bearing the salicylaldimine unit (2) for $Cu^{2+}$ selective detection. The results from fluorescence spectra demonstrated that the sensor could selectively recognize $Cu^{2+}$ over other metal cations and the detection limit is as low as $0.2{\mu}M$. Moreover, the confocal fluorescence imaging in HepG2 cells illustrated its potential for biological applications.

One-pot synthesis of highly fluorescent amino-functionalized graphene quantum dots for effective detection of copper ions

  • Tam, Tran Van;Choi, Won Mook
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1255-1260
    • /
    • 2018
  • In this work, a green and simple one-pot route was developed for the synthesis of highly fluorescent aminofunctionalized graphene quantum dots (a-GQDs) via hydrothermal process without any further modification or surface passivation. We synthesized the a-GQDs using glucose as the carbon source and ammonium as a functionalizing agent without the use of a strong acid, oxidant, or other toxic chemical reagent. The as-obtained aGQDs have a uniform size of 3-4 nm, high contents of amino groups, and show a bright green emission with high quantum yield of 32.8%. Furthermore, the a-GQDs show effective fluorescence quenching for $Cu^{2+}$ ions which can serve as effective fluorescent probe for the detection of $Cu^{2+}$. The fluorescent probe using the obtained aGQDs exhibits high sensitivity and selectivity toward $Cu^{2+}$ with the limit of detection as low as 5.6 nM. The mechanism of the $Cu^{2+}$ induced fluorescence quenching of a-GQDs can be attributed to the electron transfer by the formation of metal complex between $Cu^{2+}$ and the amino groups on the surface of a-GQDs. These results suggest great potential for the simple and green synthesis of functionalized GQDs and a practical sensing platform for $Cu^{2+}$ detection in environmental and biological applications.

HEVC 인트라 부호화를 위한 특징점 기반의 고속 CU Depth 결정 (Keypoint-based Fast CU Depth Decision for HEVC Intra Coding)

  • 김남욱;임성창;고현석;전병우
    • 전자공학회논문지
    • /
    • 제53권2호
    • /
    • pp.89-96
    • /
    • 2016
  • MPEG-H HEVC/ITU-T H.265는 quadtree 구조의 CU (Coding Unit)를 갖는 최신의 비디오 부호화 표준 기술이다. HEVC 부호화기는 모든 가능한 CU 구조에 대해서 Rate-distortion 최적화 과정을 통하여 최적 부호화 성능의 CU depth를 구할 수 있지만, 그 과정에 매우 많은 계산량을 필요로 한다. 본 연구에서는 컴퓨터 비젼 분야에서 잘 알려진 blob detection을 통하여 특징점을 찾는 과정이 저역 필터를 거치는 것과 같은 효과를 가진다는 것과 CU depth의 결정에는 영상의 고주파수 에너지 분포를 고려하는 것이 중요하다는 사실에 착안하여, blob detection 방법을 사용하여 추출된 특징점을 사용하여 HEVC 부호화기의 인트라 예측의 계산 복잡도를 낮추고자 한다. 실험을 통하여 all intra의 경우 0.45%의 BDBR 저하만으로 20% 정도의 부호화 시간을 절감할 수 있음을 보인다.

Portable Amperometric Glucose Detection based on NiS/CuS Nanorods Integrated with a Smartphone Device

  • Heyu Zhao;Kaige Qu;Haoyong Yin;Ling Wang;Yifan Zheng;Shumin Zhao;Shengji Wu
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권3호
    • /
    • pp.252-261
    • /
    • 2023
  • Glucose detection is particularly important for clinical diagnosis and personal prevention and control. Herein, the smartphone-based amperometric glucose sensors were constructed using the NiS/CuS nanorods (NRs) as sensing electrodes. The NiS/CuS NRs were prepared through a facile hydrothermal process accompanied by the subsequent vulcanization treatment. The morphological and structural properties of NiS/CuS NRs were characterized with SEM, EDS, XRD, and XPS. Electrochemical measurements including cyclic voltammetry, chronoamperometry, and electrochemical impedance spectroscopy display that NiS/CuS NRs can act as highly efficient electrocatalyst for glucose detection. The NiS/CuS NRs electrodes present a wide detection range of 1-8000 µM for glucose sensing with the sensitivity of 956.38 µA·mM-1·cm-2. The detection limit was 0.35 µM (S/N=3). When employed in smartphone-based glucose sensing device, they also display a high sensitivity of 738.09 µA·mM-1·cm-2 and low detection limit of 1.67 µM. Moreover, the smartphone-based glucose sensing device also presents favorable feasibility in determination of glucose in serum samples with the recoveries ranging between 99.5 and 105.8%. The results may provide a promising viewpoint to design other new portable glucose sensors.

Deep Learning-Based Defect Detection in Cu-Cu Bonding Processes

  • DaBin Na;JiMin Gu;JiMin Park;YunSeok Song;JiHun Moon;Sangyul Ha;SangJeen Hong
    • 반도체디스플레이기술학회지
    • /
    • 제23권2호
    • /
    • pp.135-142
    • /
    • 2024
  • Cu-Cu bonding, one of the key technologies in advanced packaging, enhances semiconductor chip performance, miniaturization, and energy efficiency by facilitating rapid data transfer and low power consumption. However, the quality of the interface bonding can significantly impact overall bond quality, necessitating strategies to quickly detect and classify in-process defects. This study presents a methodology for detecting defects in wafer junction areas from Scanning Acoustic Microscopy images using a ResNet-50 based deep learning model. Additionally, the use of the defect map is proposed to rapidly inspect and categorize defects occurring during the Cu-Cu bonding process, thereby improving yield and productivity in semiconductor manufacturing.

  • PDF

Nanostructured Metal Organic Framework Modified Glassy Carbon Electrode as a High Efficient Non-Enzymatic Amperometric Sensor for Electrochemical Detection of H2O2

  • Naseri, Maryam;Fotouhi, Lida;Ehsani, Ali
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권1호
    • /
    • pp.28-36
    • /
    • 2018
  • Metal-organic frameworks have recently been considered very promising modifiers in electrochemical analysis due to their unique characteristics among which tunable pore sizes, crystalline ordered structures, large surface areas and chemical tenability are worth noting. In the present research, $Cu(btec)_{0.5}DMF$ was electrodeposited on the surface of glassy carbon electrode at room temperature under cathodic potential and was initially used as the active materials for the detection of $H_2O_2$. The cyclic voltammogram of $Cu(btec)_{0.5}DMF$ modified GC electrode shows distinct redox peaks potentials at +0.002 and +0.212 V in 0.1 M phosphate buffer solution (pH 6.5) corresponding to $Cu^{(II)}/Cu^{(I)}$ in $Cu(btec)_{0.5}DMF$. Acting as the electrode materials of a non-enzymatic $H_2O_2$ biosensor, the $Cu(btec)_{0.5}DMF$ brings about a promising electrocatalytic performance. The high electrocatalytic activity of the $Cu(btec)_{0.5}DMF$ modified GC electrode is demonstrated by the amperometric response towards $H_2O_2$ reduction with a wide linear range from $5{\mu}M$ to $8000{\mu}M$, a low detection limit of $0.865{\mu}M$, good stability and high selectivity at an applied potential of -0.2 V, which was higher than some $H_2O_2$ biosensors.

유기 초박막 (CuTBP, ${Li}_{2}Pc$, ${C}_{22}$Py(TCNQ), PAAS LB막)의 ${NO}_{2}$ 가스 탐지 특성에 관한 연구 (A study on the ${NO}_{2}$ gas detection characteristics of the organic ultra-thin films (CuTBP, ${Li}_{2}Pc$, ${C}_{22}$Py(TCNQ), PAAS LB Films))

  • 김형석;유병호;조형근;한영재;김태완;김정수
    • 대한전기학회논문지
    • /
    • 제44권4호
    • /
    • pp.496-501
    • /
    • 1995
  • The N $O_{2}$ gas-detection characteristics were investigated using the functional organic Langmuir-Blodgett (LB) films of Copper-tetra-tert-butylphthalocyanine (CuTBP), Dilithium phthalocyanine (Li$_{2}$Pc), N-docosylpyridinium TCNQ(C$_{22}$Py(TCNQ)), Polyamic acid alkylamine salts (PAAS). The optimum conditions for a film deposition were obtained through a study of .pi.-.ALPHA. isotherms and the deposited film status was confirmed by electrical and optical methods such as UV/visible absortion spectra, thickness measurements by ellipsometry, and electrical capacitances. A response of the LB films to the N $O_{2}$ gas was measured by a change of the electrical conductivities when the film is exposed to the gases. The CuTBP LB film shows the biggest change of the electrical conductivities when it is exposed to the N $O_{2}$ gases. And the order of gas-detection performance is the following;Li$_{2}$Pc, $C_{22}$Py(TCNQ), and PAAS LB films. Especially, the CuTBP and Li$_{2}$Pc LB films not only show the bigger change in the electircal conductivities when exposed to the gas, but return to the original state when the gas is desorbed.d.

  • PDF

Detection of Trace Copper Metal at Carbon Nanotube Based Electrodes Using Squarewave Anodic Stripping Voltammetry

  • Choi, Changkun;Jeong, Youngsam;Kwon, Yongchai
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권3호
    • /
    • pp.801-809
    • /
    • 2013
  • We investigate sensitivity and limit of detection (LOD) of trace copper (Cu) metal using pristine carbon nanotube (CNT) and acidified CNT (ACNT) electrodes. Squarewave based anodic stripping voltammetry (SWASV) is used to determine the stripped Cu concentration. Prior to performing the SWASV measurements, its optimal conditions are determined and with that, effects of potential scan rate and $Cu^{2+}$ concentration on stripping current are evaluated. The measurements indicate that (1) ACNT electrode shows better results than CNT electrode and (2) stripping is controlled by surface reaction. In the given $Cu^{2+}$ concentration range of 25-150 ppb, peak stripping current has linearity with $Cu^{2+}$ concentration. Quantitatively, sensitivity and LOD of Cu in ACNT electrode are 9.36 ${\mu}A\;{\mu}M^{-1}$ and 3 ppb, while their values are 3.99 ${\mu}A\;{\mu}M^{-1}$ and 3 ppb with CNT electrode. We evaluate the effect of three different water solutions (deionized water, tap water and river water) on stripping current and the confirm types of water don't affect the sensitivity of Cu. It turns out by optical inspection and cyclic voltammetry that superiority of ACNT electrode to CNT electrode is attributed to exfoliation of CNT bundles and improved interfacial adhesion occurring during oxidation of CNTs.

산화구리 나노입자가 분산된 CNT fiber 유연 전극 기반의 글루코스 검출용 비효소적 전기화학센서 (Electrochemical Sensor for Non-Enzymatic Glucose Detection Based on Flexible CNT Fiber Electrode Dispersed with CuO Nanoparticles)

  • 송민정
    • Korean Chemical Engineering Research
    • /
    • 제61권1호
    • /
    • pp.52-57
    • /
    • 2023
  • 본 연구는 고성능 유연 전극 소재 개발을 위한 기초 연구로, 유연 전극 소재의 성능을 향상시키기 위해 금속 산화물 CuO nanoparticles (CuO NPs)를 도입하여 탄소나노튜브 섬유(carbon nanotube fiber; CNT fiber) 표면 위에 전기화학적 증착시켜 CNT fiber/CuO NPs 전극을 합성하고, 이를 전기화학적 비효소 글루코스 센서에 적용하였다. 이 전극의 표면 및 elemental composition 분석은 주사전자 현미경(SEM)과 에너지분산형 분광분석법(EDS)을 이용하였으며, 전극의 전기화학적 특성 및 글루코스에 대한 센싱 성능은 순환전압 전류법(CV)과 전기화학 임피던스법(EIS), 시간대전류법(CA)을 통해 조사되었다. CNT fiber/CuO NPs 전극은 CNT fiber의 우수한 특성과 함께 CuO NPs 도입에 따른 약 2.6배의 유효 전극면적(active surface area) 증가 효과와 11배 정도의 향상된 전자전달(electron transfer) 특성 및 우수한 전기적 촉매 활성(electrocatalytic activity) 덕분에 CNT fiber 유연 기반 전극의 글루코스 검출에 대한 성능이 개선되었다. 따라서, 본 연구를 기반으로 다양한 나노구조체를 활용한 고성능 유연 전극 소재 개발이 기대된다.