• Title/Summary/Keyword: $Cr^{3+}$ ion

Search Result 295, Processing Time 0.028 seconds

Evaluation of Effective Process Operation for the Texitile Dyeing Wastewater by Ferrous Solution and Hydrogen Peroxide

  • Lee, Sang Ho;Moon, Hey Jin
    • Journal of Environmental Science International
    • /
    • v.13 no.11
    • /
    • pp.987-991
    • /
    • 2004
  • The purpose of this research is to evaluate the removal efficiencies of COD$\_$Cr/ and color for the dyeing wastewater by the different dosages of ferrous solution and H$_2$O$_2$ in Fenton process. In the case of H$_2$O$_2$ divided dosage for the Fenton's reagent 7:3 of H$_2$O$_2$ was more effective than 3:7 to remove COD$\_$Cr/ and color. The results showed that COD$\_$Cr/ was mainly removed by Fenton coagulation, where the ferric ions are formed in the initial step of Fenton reaction. On the other hand color was removed by Fenton oxidation rather than Fenton coagulation. The removal mechanism of COD$\_$Cr/ and color was mainly coagulation by ferrous ion, ferric ion and Fenton oxidation. The removal efficiencies were dependent on the ferric ion amount at the beginning of the reaction. However, the final removal efficiency of COD$\_$Cr/ and color was in the order of Fenton oxidation, ferric ion coagulation and ferrous ion coagulation. The reason of the highest removal efficiency by Fenton oxidation can be explained by the chain reactions with ferrous solution, ferric ion and hydrogen peroxide.

Binding of the Hexavalent Chromium Ions in the Process of Cement Hydration (시멘트 수화에 따른 6가 크롬의 고정화 특성)

  • Jung, Min-Sun;Hwang, Jun-Pil;Hong, Sung-In;Ann, Ki-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.88-94
    • /
    • 2013
  • The hexavalent chromium (Cr(VI)) is well known as a hazardous ion, presumably inducing dermatic diseases and if serious cancer. The present study concerns the binding capacity of Cr(VI) ions in the cement powder and matrix for a quantitative technique of Cr(VI) ions in cement to influence human health. Both the water-soluble and acid-soluble Cr(VI) ions present in 3 types of ordinary Portland cement (OPC), pulverised fuel ash (PFA), ground granulated blast furnace slag (GGBS), and silica fume (SF) were measured using the spectrophotometer. As a result, it was found that the concentration of water-soluble Cr(VI) ion in cement ranged from 10.5 to 18.9mg/kg-cement, and in the additional materials a very low value of Cr(VI) ion was measured. Acid-soluble Cr(VI) ion was even higher than water-soluble Cr(VI) ion, ranging from 172.4 to 318.2mg/kg-cement. Nevertheless, the concentration of acid-soluble Cr(VI) ion is not proportional to addition of acid. It depends rather the variable pH of solvent involving cement paste. As enough cement hydration occurs, the binding capacity of Cr(VI) ion increases, inhibiting this ions from leaching out in the presence of hydration products such as ettringite or tri-calcium aluminate which bind Cr(VI) ion by ion-exchange.

Effect of the Droplets on the Wear Characteristics of Steel for the Cold Working Roller (Droplet가 냉연 롤러용 강의 마모 특성에 미치는 영향)

  • 문봉호
    • Tribology and Lubricants
    • /
    • v.20 no.3
    • /
    • pp.145-151
    • /
    • 2004
  • A modified surface layer by ion implantation is very thin (under 1 $\mu\textrm{m}$) but has superior mechanical characteristics. therefore ion implantation has been used successfully as a surface treatment technology to improve the wear, fatigue, and corrosion resistances of materials. MEVVA which is a kind of ion beam apparatus has merits of low cost and is usable to various metals, but occurs a droplet ranging from micron to tens of micron on the implanted surface at ion implantations. wear is a dynamic phenomenon on interacting surfaces with rotative motion. Since wear changes in condition of the surface, we should control to surface. In order to improve a wear resistance of Ti ion implanted 1C-3Cr steel(material for roller in the cold working process), it is essential to investigate the effect of the droplets on the wear characteristics. In this study, we investigate the effect of the droplets on the wear characteristics of 1C-3Cr steel using SEM Tribosystem as in-situ system. Results show that the droplet occurred at ion implantation becomes the cause of severe wear. Therefore, the ion-implanted surface should be removed the droplet to improve wear resistance.

Simultaneous Determination of Chromium (III) and Chromium(VI) by High Performance Liquid Chromatography(HPLC) (고성능 액체크로마토그래피(HPLC)를 이용한 3가, 6가 크롬의 동시정량에 관한 연구)

  • Roh, Jae Hoon;Kim, Chi Nyon;Kim, Choon Sung;Kim, Kyoo Sang
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.189-197
    • /
    • 1994
  • Analytic methods for Cr(VI) level in industrial hygienic field were suggested by the National Institute for Occupational Safety and Health(NIOSH method 7600, 7604). There were growing needs for measurement of Cr(III) and Cr(VI) levels simultaneously. Two analytical methods were suggested to determine Cr(III) and Cr(VI) levels simultaneously. The one is method by using reversed phase high peformance liquid chromatography(HPLC) and the other is by using ion exchange HPLC. The purpose of this work was to evaluate the usefulness of these two analytic methods. For the difference of ionic charges of Cr(III)-ethylendiamine tetraacetic acid(EDTA) chelate and $CrO_4{^-2}$, we could detect them simultaneously by ion exchange HPLC. Also, we attempted to determine the levels of Cr(III) and Cr(VI) chelated with sodium diethyldithiocarbamate(NaDDTC) by using reversed phase HPLC. The confirmation of Cr(III) and Cr(VI) were checked by fraction collector and nameless atomic absorption spectrometer. The optimal conditions for the formation of Cr(III)-EDTA chelate were two hours incubation period with pH 5. Cr(III)-EDTA and Cr(VI) in EDTA solution were successfully separated by anion exchange column using $Na_2CO_3/NaOH$ mixture as mobile phase. Peaks of Cr(III)-EDTA and Cr(VI) in EDTA were identified at 5 minutes and 7 minutes of retention time respectively by the ion exchange HPLC. The formation of Cr(III)-NaDDTC and Cr(VI)-NaDDTC chelates were twelve hours incubation period. Cr(III)-NaDDTC and Cr(VI)-NaDDTC chelates were separated by reversed phase column using methanol and water mixture as mobile phase. Peaks of Cr(VI)NaDDTC and Cr(III)-NaDDTC chelates were identified at 13 minutes and 26 minutes of retention time respectively by the reversed phase HPLC. Due to reduction of Cr(VI) to Cr(III), it seems to be not suitable for simultaneous determination of Cr(III)-NaDDTC and Cr(VI)-NaDDTC chelates by reversed phase HPLS. Simultaneos determination of Cr(III) and Cr(VI) by ion exchange HPLC was more accurate and simple method.

  • PDF

The Electrochemical Migration Phenomenon of the Ni-Cr Seed Layer of Sputtered FCCL

  • Ahn, Woo-Young;Jang, Joong Soon
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.2
    • /
    • pp.63-67
    • /
    • 2014
  • As the demand for fine-pitch FPCB (Flexible Printed Circuit Board) increases, so do the number of applications of sputtered FCCL (Flexible Copper Clad Laminate). Furthermore, as the width between the circuit patterns decreases, greater defects are observed in the migration phenomenon. In this study we observed changes in ion migration in real circuit-pattern width using sputtered FCCL. We found that as the applied voltage and residue thickness of the NiCr seeds increase, ion migration occurs faster. If the NiCr seed layer thickens due to a high cathode power and long deposition time while being sputtered, the NiCr will form a residue that quickly becomes a factor for incurring ion migration.

Development of methodology for evaluating tribological properities of Ion-implanted steel (이온 주입한 강의 미시적 마모 튼성의 평가)

  • MOON, Bong-Ho;CHOI, Byung-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.9
    • /
    • pp.146-154
    • /
    • 1997
  • Ion implantation has been used successfully as a surface treatment technology to improve the wear. fatigue and corrosion resistances of materials. A modified surface layer by ion implantation is very thin(under 1 m), but it has different mechanical properties from the substrate. It has also different wear characteristics. Since wear is a dynamic phenomenon on interacting surfaces with relative motion, an effective method for investigtating the wear of a thin layer is the observation of wear process in microscopic detail using in-situ system. The change of wear properties produces the transition of wear mode. To know the microscopic wear mechanism of this thin layer, it is very important to clarify its microscopic wear mode. In this paper, using the SEM and AFM Rribosystems as in-situ system, the microscopic wear of Ti ion-implanted 1C-3Cr steel, a material for roller in the cold working process, was investigated in repeated sliding. The depth of wear groove and the speciffc wear amount were changed with transition of microscopic wear mode. The depth of wear groove with friction cycles in AFM tribosystem and specific wear amount of Ti ion-implanted 1C-3Cr steel were less about 2-3 times than those of non-implanted 1C-3Cr steel. The microscopic wear mechansim of Ti ion-implanted 1C-3Cr steel was also clarified. The microscopic wear property was quantitatively evaluated in terms of microscopic wear mode and specific wear amount.

  • PDF

Synthesis of Multifunctional AN-co-(MMA/IA) Fibrous ion-exchanger by Hydrolysis and Adsorption Properties for Trace Transition Elements (가수분해에 의한 AN-co-(MMA(IA) 다관능성 섬유이온교환체의 합성 및 미랑 전이금속 흡착특성)

  • 황택성;이선아;황계순
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.765-773
    • /
    • 2001
  • In In order to remove harmful trace elements such as $Co^{2+}$, $Ni^{2+}$ , $Cr_2O_7\;^{2-}$ from water, we synthesized AN-co-(MMA/IA) according to various mole ratio of monomers and spun by wet-spinning. And multi-functional PAN ion exchangers were prepared by hydrolysis. We observed structure, degree of functionalization, ion exchange capacity, distribution coefficient and mechanical properties for ion exchanger. Anion exchange capacity decreased in 4.5 ~ 4.2 meq/g with increasing of IA content and cation exchange capacity increased in 1.8 ~ 2.2 meq/g. Tensile strength of the ion exchanger increased up to 0.008 mol% IA content and appeared maximum value by 216$kg/cm^2$Distribution coefficient for AN-co-(MMA/IA) ion exchanger appeared maximum value for Co(II), Ni(II) in pH 5-6 range and for Cr(III) in pH 3-4 range. And the adsorption capacity was in the order of Cr(III) > Co(II) > Ni(II) for multicomponent in continuous process.

  • PDF

The Electronic Structure and Reactivity of Transition Metal Complexes (III). Effect of Pressure on the Aquation of $[Cr(NH_3)_5(DMF)]^{3+}$ Ion (전이금속 착물의 전자구조 및 화학적 반응성 (제 3 보) $[Cr(NH_3)_5(DMF)]^{3+}$ 이온의 수화반응에 미치는 압력효과)

  • Jong-Jae Chung;Choi Jong-Ha;Eun-Ki Kim
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.582-587
    • /
    • 1989
  • Rates for aquation of $[Cr(NH_3)_5(DMF)]^{3+}$ ion in aqueous acidic solution have been measured by spectrophotometric method at various temperatures and pressures. The volume of activation for the aquation is small negative and lies in the limited range -2.76 ∼ -3.65 $cm^3mol^{-1}$. The entropy and compressibility coefficient of activation are small negative values. From the results of thermodynamic activation parameters, it can be inferred that the aquation of $[Cr(NH_3)_5(DMF)]^{3+}$ ion proceeds through an associative interchange($I_a$) mechanism.

  • PDF

Corrosion Behavior of Cr-bearing Corrosion Resistant Rebar in Concrete with Chloride Ion Content

  • Tae, Sung Ho
    • Architectural research
    • /
    • v.7 no.1
    • /
    • pp.49-54
    • /
    • 2005
  • Conventional studies have focused on the reduction in the water-cement ratio, the use of various admixtures, etc., to ensure the durability of reinforced concrete structures against such deterioration factors as carbonation and chloride attack. However, improvement in the concrete quality alone is not considered sufficient or realistic for meeting the recent demand for a service life of over 100 years. This study intends to improve the durability of reinforced concrete structures by improvement in the reinforcing steel, which has remained untouched due to cost problems, through subtle adjustment of the steel components to keep the cost low. As a fundamental study on the performance of Cr-bearing rebars in steel reinforced concrete structures exposed to corrosive environments, The test specimens were made by installing 8 types of rebars in concretes with a chloride ion content of 0.3, 0.6, 1.2, 2.4 and $24kg/m^3$. Corrosion accelerated curing were then conducted with them. The corrosion resistance of Cr-bearing rebars was examined by measuring crack widths, half-cell potential, corrosion area and weight loss after 155 cycles of corrosion-accelerating curing. The results of the study showed that the corrosion resistance increased as the Cr content increased regardless of the content of chloride ions, and that the Cr-bearing rebars with a Cr content of 5% and 9% showed high corrosion resistance in concretes with a chloride ion content of 1.2 and $2.4kg/m^3$, respectively.

Determination of the Magnetic Moment of $Cr_2O_3$ by a Proportional Relation

  • Kim, Yong-Jin;Kim , Jung Gi
    • Journal of Magnetics
    • /
    • v.1 no.2
    • /
    • pp.55-56
    • /
    • 1996
  • The effective magnetic moment of Cr$_2$O$_3$is determined by assuming that a proportional relation holds between its moment and the effective magnetic moment of hematite determined by the previous derived relaxation expression and the moments of Fe3+ ion and Cr3+ ion. The result obtained from the relation is found to be given by 0.10 in Bohr magneton which is in good agreement with the value obtained by use of the expression.

  • PDF