A Study on the Development and Accuracy Improvement of an IR Combustible Gas Leak Detector with Explosion Proof (방폭형 적외선 가연성가스 누출검지기 개발 및 정확도 향상 연구)

  • Park, Gyou-Tae;Lyu, Geun-Jun;Jo, Young-Do;Kwon, Jeong-Rock;Ahn, Sang-Guk;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.1-12
    • /
    • 2014
  • In this paper, we developed an explosion proof type and portable combustible gas leak detector and proposed an algorithm to improve the accuracy for measuring gaseous concentrations. The nation's first we developed an infrared gas leak detector with explosion proof standard(Ex d ib) and improved measuring accuracy by using linearization recursion equation and 2nd Lagrange interpolation polynomial. Together, we advanced their performances and added their easy functions after investigating field demands. To compare our and other company's detectors, we performed measurement tests with eight standard gases made by Korea Gas Safety Corporation. We demonstrated the excellence of our instruments in measuring accuracy other than detecters through experimental results.

Design of a Timing Error Detector Using Built-In current Sensor (내장형 전류 감지회로를 이용한 타이밍 오류 검출기 설계)

  • Kang, Jang-Hee;Jeong, Han-Chul;Kwak, Chol-Ho;Kim, Jeong-Beom
    • Journal of IKEEE
    • /
    • v.8 no.1 s.14
    • /
    • pp.12-21
    • /
    • 2004
  • Error control is one of major concerns in many electronic systems. Experience shows that most malfunctions during system operation are caused by transient faults, which often mean abnormal signal delays that may result in violations of circuit element timing constraints. This paper presents a novel CMOS-based concurrent timing error detector that makes a flip-flop to sense and then signal whether its data has been potentially corrupted or not by a setup or hold timing violation. Designed circuit performs a quiescent supply current evaluation to determine timing violation from the input changes in relation to a clock edge. If the input is too close to the clock time, the resulting switching transient current in the detection circuit exceeds a reference threshold at the instant of the clock transition and an error is flagged. The circuit is designed with a $0.25{\mu}m$ standard CMOS technology at a 2.5 V supply voltage. The validity and effectiveness are verified through the HSPICE simulation. The simulation results in this paper shows that designed circuit can be used to detect setup and hold time violations effectively in clocked circuit element.

  • PDF

Strength analysis of mechanical transmission using equivalent torque of plow tillage of an 82 kW-class tractor

  • Kim, Taek-Jin;Kim, Wan-Soo;Kim, Yeon-Soo;Chung, Sun-Ok;Park, Seong-Un;Hong, Soon-Jung;Choi, Chang-Hyun;Kim, Yong-Joo
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.4
    • /
    • pp.723-735
    • /
    • 2019
  • The power-train is the most important component of an agricultural tractor. In this study, the strength of the driving gear transmission of an 82 kW-class tractor was analyzed using equivalent torque during plow tillage. The load measurement system consisted of an engine revolution speed sensor, torque-meters, revolution speed sensors for four axles, and pressure sensors for two hydraulic pumps. The load data were measured during plow tillage for four speed stages: F2 (2.78 km/h), F5 (5.35 km/h), F7 (7.98 km/h), and F8 (9.75 km/h). Aspects of the gear-strength such as bending stress, contact stress, and safety factors were analyzed under two torque conditions: the equivalent torque at the highest plow load for the F8 speed stage and the maximum engine torque. The simulation results using KISSsoft showed that the maximum engine torque conditions had a lower safety factor than did the highest equivalent torque condition. The bending safety factors were > 1 at all gear stages, indicating that gear breakage did not occur under actual measured operating conditions, nor under the maximum torque conditions. However, the equivalent torque condition in the contact stress safety factor was > 1, and the maximum torque condition was < 1 at the first gear pair. The method of analysis using the equivalent torque showed lower stress and higher safety factor than did the method using maximum torque. Therefore, when designing a tractor by applying actual working torque, equivalent torque method would support more reliable product development.

A CMOS Bandgap Reference Voltage/Current Bias Generator And Its Responses for Temperature and Radiation (CMOS Bandgap 기준 전압/전류 발생기 및 방사능 응답)

  • Lim, Gyu-Ho;Yu, Seong-Han;Heo, Jin-Seok;Kim, Kwang-Hyun;Jeon, Sung-Chae;Huh, Young;Kim, Young-Hee;Cho, Gyu-Seong
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1093-1096
    • /
    • 2003
  • 본 논문에서는, CMOS APS Image Sensor 내에 포함되어 회로의 면적을 줄인 새롭게 제안된 CMOS Bandgap Reference Bias Generator (BGR)를 온도 및 방사능에 대한 응답을 실험하였다. 제안된 BGR 회로의 설계 목표는 V/sub DD/는 2.5V이상이고, V/sub ref/는 0.75V ± 0.5mV 마진을 가지게 하는 것이다. 제안된 BGR회로는 Level Shifter를 갖는 Differential OP-amp단과 Feedback-Loop를 가지는 Cascode Current Mirror를 사용하여 저전압에서도 동작을 가능하게 하였으며, 높은 출력저항 특성을 가지도록 하였다. 제안된 BGR회로는 하이닉스 0.18㎛ ( triple well two-poly five-metal ) CMOS 공정을 이용하여 Test Chip을 제작하였다. 온도의 변화와 Co-60 노출조건 하에서 Total ionization dose (TID) effect된 BGR회로의 V/sub ref/를 측정하여, 이를 평가하였다. 온도에 대한 반응은, 25℃ 일 때의 V/sub ref/에 대해, 각각 45 ℃에서 0.128%. 70℃에서 0.768% 변화하였다. 그리고 온도가 25℃일 때 50krad와 100krad의 방사능을 조사 하였을 경우, V/sub ref/는 각각 2.466%, 그리고 4.612% 변화하였다.

  • PDF

Evaluation of Interactions Between Surface Water and Groundwater Based on Temperature, Flow Properties, and Geochemical Data (온도, 유동특성 및 지화학분석 자료를 이용한 지표수-지하수 연계특성 평가)

  • Jeon, Hang-Tak;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.21 no.1
    • /
    • pp.45-55
    • /
    • 2011
  • We examined the interactions between surface and groundwater through (1) flowmeter logging, (2) measurements of seasonal and vertical changes in temperature within a well, and (3) geochemical analyses of water samples from nine groundwater-monitoring wells. At two wells adjacent to a stream, subsurface water was found to flow from the stream to a surrounding alluvial fan, and the seasonal change in groundwater temperature is similar to those of surface water and air. Geochemical analyses at two wells indicated hydro-geochemical features affected by streamwater inflow, showing seasonal variations. Accordingly, these two wells are located in an area with active interaction between surface water and groundwater. The Thermochron I-button used in the present study is useful for this type of study of groundwater?surface water interaction because of its low cost and small size.

Participation of SRE4, an URE1 Enhancer Core Sequence, in the Sterol-Mediated Transcriptional Upregulation of the Human Apolipoprotein E Gene

  • Min, Jung-Hwa;Paik, Young-Ki
    • BMB Reports
    • /
    • v.31 no.6
    • /
    • pp.565-571
    • /
    • 1998
  • The expression of the endogenous human apolipoprotein(apo)E gene was significantly induced when HepG2 cells were treated with exogenous 25-hydroxy-cholesterol. This sterol-mediated apoE gene upregulation appears to require the participation of a positive element for the apoE gene transcription (PET) ( -169/ -140), a core sequence of upstream regulatory element (URE)1 enhancer of the human apoE gene. This PET was renamed as sterol regulatory element (SRE)4 based on its new role as a sensor for the level of intracellular sterol. Furthermore, a gel mobility shift analysis showed that binding activity of the SRE4 binding protein (BP) obtained from HepG2 cells was induced by sterol treatment, while that from either MCF7 or BT20 cells remained unchanged. Binding activity of SRE4BP was also induced in mouse macrophage cells, J774A.1, by sterol treatment, but it was drastically reduced when cells were subjected to treatment of AY-9944, a potent inhibitor for sterol synthesis. However, binding activity of Spl, which is a co-binding protein to the SRE4 region, remained the same in either condition, suggesting that SRE4BP (formally known as PETBP) may be mainly responsible for the sterol-mediated regulation of the apoE gene expression. Deletion analysis of the core binding site of SRE4BP by gel mobility shift assays showed that the minimal sequence of the SRE4BP binding appears to reside between -157 and -140, confirming the identity of SRE4 with the previously determined core sequence of URE1.

  • PDF

The Effect of Quantitative Occlusal Force on the Size of Temporomandibular Joint Space (정량적 교합력이 측두하악관절강 크기에 미치는 영향)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.17 no.2
    • /
    • pp.27-35
    • /
    • 1992
  • The purpose of this study was to evaluate the size of the temporomandibular joint space by the increase of the occlusal force on the working side and the non-working side during unilateral biting. For the study, 22 normal adults, age from 23 to 25, who had normal or class I molar relationship and had no symptoms on TMJ area and masticatory muscles were selected. Transcranial TMJ radiograph was taken during unilateral biting with the sensor of occlusal load measuring device (MPM-3000 ; Nihon Kohden Kogyo Co. Ltd., Japan) on 1st molar teeth of right and left side given to force of 0kg, 10kg, 20kg and 30kg respectively with Accurad-200(Denar Corperation's product). The radiographs were traced on the screen, with enlaged as 5 times. The size of temporomandibular joint space at anterior, superior and posterior compartment were measured with Dumas's method (reference line between squamotympanic fissure and the lowest point of articular eminence). The following results were obtained by this study. 1. The size of anterior TMJ space showed a tendency to decrease on the working side and increase on the non-working side by the increase of the occlusal force, but had no statistical significancy (P>0.05). 2. The size of superior TMJ space showed a tendency to increase on the working side and decrease on the non-working side by the increase of the occlusal force (P<0.05). 3. The size of posterior TMJ space showed a tendency to decrease on both working and nonworking side, but had no statistical significancy (P>0.05)

  • PDF

Measurement of Absorbed Dose for High Energy Electron using $CaSO_4$:Tm-PTFE TLD ($CaSO_4$:Tm-PTFE TLD를 이용한 고에너지 전자선의 흡수선량 측정)

  • Park, Myeong-Hwan;Kim, Do-Sung;Doh, Sih-Hong;Kim, Wan;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.314-319
    • /
    • 2001
  • In this study, the highly sensitive $CaSO_4$:Tm-PTFE TLDs has been fabricated for the purpose of measurement of high energy electron. $CaSO_4$:Tm phosphor powder was mixed with polytetrafluoroethylene(PTFE) powder and moulded in a disk type(diameter 8.5mm, thickness $90mg/cm^2$) by cold pressing. The batch uniformities were average deviation 3.1%. The TLDs were applied to measurement of absorbed dose distribution for high energy electron, the ranges were determined to be $R_{100}=14.5mm$, $R_{50}=24.1mm$ and $R_p=31.8mm$, respectively. The beam flatness were 4.5% as the variation of dose relative to the central axis over the central 80% of the field size at a maximum dose depth in a plane perpendicular to the central axis.

  • PDF

Preparation of Dithizone Functionalized Polystyrene for Detecting Heavy Metal Ion (중금속 검지를 위한 디티존 기능화된 폴리스티렌 제조)

  • Shin, Hyeon Ho;Kim, Younghun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.2
    • /
    • pp.243-246
    • /
    • 2015
  • Colorimetric sensors were usually used to detect specific metal ions using selective color change of solutions. While almost organic dye in colorimetric sensors detected single molecule, dithizone (DTZ) solution could be separately detected above 5 kinds of heavy metal ions by the change of clear color. Namely, DTZ could be used as multi-colorimetric sensors. However, DTZ was generally used as aqueous type and paper/pellet-type DTZ was not reported yet. Therefore, in this work, polystyrene (PS) was prepared to composite with DTZ and then DTZ/PS pellet was obtained, which was used to selectively detect 10 kinds of heavy metal ions. When 10 ppm of Hg and Co ions was exposed in DTZ/PS pellets, clear color change was revealed. It is noted that DTZ/PS pellet could be used in detecting of heavy metal ion as dry type.

Heavy Metals Extraction from Contaminated Soils using Aqua Regia Extraction (왕수를 이용한 중금속 오염토양에서의 추출방안 연구)

  • Lee, Dukyoung;Jung, Sunkook;Son, Younggyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.2
    • /
    • pp.15-22
    • /
    • 2018
  • Aqua regia extraction for the quantification of heavy metals and As in contaminated soils was investigated as one of preliminary steps for on-site monitoring using sensor technology. Soil samples were taken from closed railway depot, closed mines, and closed refinery and various extraction conditions including $30^{\circ}C/15min$, $30^{\circ}C/30min$, $30^{\circ}C/60min$, $30^{\circ}C/120min$, $80^{\circ}C/15min$, $80^{\circ}C/30min$, $80^{\circ}C/60min$, $80^{\circ}C/120min$ were tested. The optimal extraction condition was determined as $80^{\circ}C/60min$ because the extraction efficiencies of Zn were relatively low and did not reach the targeted level (80-100% of original concentrations) for $30^{\circ}C$ conditions. It was found that the fractionation of heavy metals and As using the sequential extraction method was useful to understand the degree of metal extraction. In order to enhance the extraction efficiency within short extraction time, ultrasound technology using a 20 kHz horn-type sonicator was additionally used for $30^{\circ}C/15min$. It was revealed that ultrasound could significantly enhance the extraction efficiency and pulsed irradiation showed higher efficiency than continuous irradiation due to the less formation of bubble clouds. However high temperature condition ($80^{\circ}C$) was required to achieve high extraction efficiency for Zn in spite of the use of ultrasound.