• Title/Summary/Keyword: $CO_2$laser

Search Result 988, Processing Time 0.023 seconds

Comparative study of wound healing in canine stomach with CO2 laser and scalpel incisions (CO2 레이저와 scalpel을 이용한 위 절개 시 개에서의 창상 치유 평가)

  • Lee, Jae-Yeon;Hwang, You-Sun;Kim, Han-Kyul;Choi, Hyun-Suk;Jeong, Seong-Mok;Cho, Sung-Whan;Park, Chang-Sik;Kim, Myung-Cheol
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.2
    • /
    • pp.155-160
    • /
    • 2010
  • The objective of this study was to compare wound healing in stomach with $CO_{2}$ laser and scalpel incision by measuring the extent of bleeding, the ease of gastric incision, incision time, degree of adhesion and wound healing degree in dogs. Sixteen healthy dogs were used. Two symmetrical incisions were made in ventral aspect of the stomach between the greater and lesser curvatures were made with scalpel and 0.2 mm spot diameter $CO_{2}$ laser (8W, continuous wave) in sixteen dogs. And then each wound was closed with absorbable suture in a two-layer inverting seromuscular pattern. At 3, 7, 14 and 21 days after initial wounding, each wound was taken for histological observation. On surgery, the extent of bleeding, the ease of incision and incision time showed significant differences between the groups. The $CO_{2}$ laser provided better hemostasis (p < 0.05) and smaller postoperative adhesion compared with the scalpel. However, the scalpel produced faster speed of incision and was easier to handle than the $CO_{2}$ laser (p < 0.05). Although there was no considerable difference between the two groups in histological observation, necrosis and calcium deposit tended to be larger in the $CO_{2}$ laser than in the scalpel.

The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive (레이저 처리후 임프란트 표면 변화에 관한 연구)

  • Kim, Tae-Jung;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

A COMPARATIVE STUDY OF WOUND HEALING AFTER SKIN INCISION WITH SCALPEL, $CO_2$, AND Nd:YAG LASER IN RATS (수술칼, $CO_2$ 및 Nd:YAG 레이저에 의한 절개 창상의 치유에 관한 비교 연구)

  • Choi, Jae-Sun;Ryu, Sun-Youl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.1
    • /
    • pp.33-42
    • /
    • 2000
  • The purpose of this study was to compare the wound healing process after skin incision using scalpel, $CO_2$ laser and pulsed Nd:YAG laser in rats. After skin on the back was incised 3 cm long, rats were sacrificed at 1, 3, 7, 14, 21 and 28 days. Macroscopic, histologic and immunohistochemical examinations using the collagen type IV and the CD34 antibodies which are necessary to the forming process of new capillary were performed. Results obtained were as follows ; Macroscopically the initial wound healing of the laser group was about $1{\sim}2$ weeks slower than that of the scalpel group. There weren't however any remarkable differences in all groups in 4 weeks after incision. By histologic finding, acute inflammatory cells were more prominent during the initial wound healing in the scalpel group than in the other groups. Epithelialization started in the order of scalpel, $CO_2$ and Nd:YAG laser group after skin incision. By the Masson's trichrome stain, collagen synthesis in the Nd:YAG laser group was more slowly initiated than in the other groups. But it was completed at the $3{\sim}4$ weeks in all groups. Immunohistochemically, collagen type IV and CD34 expression were markedly increased at 2 weeks in the scalpel and $CO_2$ laser group. Meanwhile, in the Nd:YAG laser group, these reactions were observed later tan the other groups. Collagen type IV and CD34 expression were decreased in all groups after 4 weeks. These results suggest that $CO_2$ and Nd:YAG laser showed similar healing process compared with scalpel and a potential substitute for scalpel in skin incision.

  • PDF

Fixed system of action waveform by pulse module special quality of obstetrics and gynecology pulse style $CO_2$ laser relationship embodiment (산부인과 펄스형 $CO_2$ 레이저의 펄스모듈 특성에 의한 동작파형의 일정한 시스템의 구현)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.159-161
    • /
    • 2007
  • $CO_2$ laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400ums laser beam in rain focus sacred ground surroundings cellular tissue without vitiation me by evaporation Poe of very small floor as is clean steam can. Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can. Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF

Fabrication of Grooved Pattern for the Light Guide Plate of TFT-LCD with CO2 Laser (CO2 레이저 빔을 이용한 TFT-LCD 도광판의 패턴 제작에 관한 연구)

  • 김경동;백창일;송철기;안성훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.147-150
    • /
    • 2002
  • A light guide panel is an element of the LCD backlight module that is often used for the display of compact electronic devices. In this study, a laser marking system is proposed to fabricate light guide panel, which can be replaced of other manufacturing methods such as silk printing, stamping, and v-cutting methods. The objectives of this research are the establishment of laser marking system, evaluation of laser marking parameters, understanding marking process, application to PMMA, reliability test and quality inspection. A 50W $CO_2$ laser (CW) was used to perform different experiments in which, the influence of some processing parameters (average power, scanning speed) on the geometry and quality of groove pattern was studied. The width of the etched grooves increases with increasing a laser power and decreasing a scan speed. In order to analyze surface characteristics and optical properties (luminance, uniformity), SEM photography and BM7 (luminance measuring system) were used. As a result, the optimal conditions of the process parameters were determined.

  • PDF

Management of traumatic oral mucosal lesion by CO2 LASER (CO2 레이저를 이용한 다양한 외상성 구강점막병소의 처치법)

  • Byun, Jin-Seok;Jung, Jae-Kwang;Choi, Jae-Kap
    • The Journal of the Korean dental association
    • /
    • v.53 no.12
    • /
    • pp.910-916
    • /
    • 2015
  • Various mucosal lesions are originated in oral cavity and trauma is most common cause of these lesions. Definitive treatment of these lesions is stop of traumatic events and removal. There are two representative removal methods in medical fields; conventional mess or LASER. Compare to conventional mess technique, LASER has several advantages such as bleeding control, pain reduction. Of the various LASER systems, $CO_2$ LASER is regarded as best choice for general practitioners due to its convenience, universal use and high cost/benefit effects. In these article, we report the treatment cases of mucocele, fibroma, and leukoplakias using $CO_2$ LASER. Eventhough there are malignancy potential of oral mucosal lesion especially leukoplakias, careful history taking, clinical examination, and regular check-up will help the general practitioners to manage these lesions. Simple and relatively safe oral mucosal lesions have to be treated more in general dental practitioners.