• Title/Summary/Keyword: $CO_2$Gas

Search Result 4,994, Processing Time 0.033 seconds

Fabrication and Evaluation of the SnO2 Based Gas Sensor for CO and NOx Detection (SnO2를 이용한 CO 및 NOx 가스 감지 센서 제작 및 특성 연구)

  • Kim, Man Jae;Lee, Yu-Jin;Ahn, Hyo-Jin;Lee, Sang Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.5
    • /
    • pp.515-523
    • /
    • 2015
  • In this paper, we fabricated and evaluated the gas sensor for the detection of CO gas and $NO_X$ gas among the vehicle exhaust emission gasses. The $SnO_2$ (tin dioxide) layer is used as the detection material, and the thin-film type and the nano-fiber type layers are deposited with various thicknesses using sputtering method and electro spinning method, respectively. The experiments are performed in the chamber where the gas concentration is controlled with mass flow controller. The fabricated devices are applied to the CO and $NO_X$ gas, where the device with the thinner $SnO_2$ layer shows better sensitivity. The nano-fiber has the larger surface area, and the shorter response time and recovery time are obtained. From the experimental results, both types of gas sensors successfully detect CO and $NO_X$ gases, which can be applied to measure those gases from the vehicle emissions.

Gas Sensing Characteristics of Nano Sized SnO2 Sensors for Various Co and Ni Concentration (Co, Ni 농도 변화에 따른 나노 SnO2 센서의 감응 특성)

  • Lee, Ji-Young;Yu, Yoon-Sic;Yu, Il
    • Korean Journal of Materials Research
    • /
    • v.21 no.10
    • /
    • pp.546-549
    • /
    • 2011
  • Nano-sized $SnO_2$ thick films were prepared by a screen-printing method onto $Al_2O_3$ substrates. The sensing characteristics were investigated by measuring the electrical resistance of each sensor in a test box as a function of the detection gas. The nano-sized $SnO_2$ thick film sensors were treated in a $N_2$ atmosphere. The structural properties of the nano $SnO_2$with a rutile structure according to XRD showed a (110) dominant $SnO_2$ peak. The particle size of $SnO_2$:Ni nano powders at Ni 8 wt% was about 45 nm, and the $SnO_2$ particles were found to contain many pores according to the SEM analysis. The sensitivity of the nano $SnO_2$-based sensors was measured for 5 ppm $CH_4$ gas and $CH_3CH_2CH_3$ gas at room temperature by comparing the resistance in air with that in the target gases. The results showed that the best sensitivity of $SnO_2$:Ni and $SnO_2$:Co sensors for $CH_4$ gas and $CH_3CH_2CH_3$ gas at room temperature was observed in $SnO_2$:Ni sensors doped with 8 wt% Ni. The response time of the $SnO_2$:Ni gas sensors was 10 seconds and recovery time was 15 seconds for the $CH_4$ and $CH_3CH_2CH_3$ gases.

Gas Permeation Characteristics by Chitosan/Pebax Composite Membranes (Chitosan/Pebax 복합 막에 의한 기체투과 특성)

  • Kim, Sun Hee;Hong, Se Ryeong
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.319-327
    • /
    • 2017
  • Chitosan/Pebax composite membranes were prepared with 1 : 1, 1 : 2, 1 : 10, 1 : 30 mass ratio of pebax and chitosan. Gas permeation test were carried out under pressure $6kgf/cm^2$, 35, $45^{\circ}C$ and $65^{\circ}C$ at different temperatures. The gas permeability and selectivity ($CO_2/N_2$) of $N_2$ and $CO_2$ for the Chitosan/Pebax composite membranes were investigated. As the amount of Pebax added to chitosan was increased the gas permeability of both $N_2$ and $CO_2$ increased. The selectivity ($CO_2/N_2$) was 6.9~44.3 in the Chitosan/Pebax composite membranes. With the increase of contents of Pebax and the decrease of temperature, the selectivity ($CO_2/N_2$) increased.

Effects of $CO_2$ and $H_2O$ Additions on Partially Premixed Counterflow Flame by Considering Nongray Gas Radiation (비회색 가스 복사를 고려한 층류대향류 부분예혼합 화염에서의 $CO_2$$H_2O$ 첨가에 따른 영향 연구)

  • Jo, Bum-Jin;Kim, Tae-Kuk
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.3
    • /
    • pp.10-16
    • /
    • 2005
  • Detailed flame structures of the counterflow flames of $CH_4/Air$ formed with $CO_2$ and $H_2O$ addition are studied numerically. The detailed chemical reactions are modeled by using the OPPDIF and CHEMKIN-II code. Only the $CO_2$ and $H_2O$ are assumed to participate in radiative heat transfer while all other gases are assumed to be transparent. The discrete ordinates method(DOM) and the narrow band based WSGGM with a gray gas regrouping technique(WSGGM-RG) are applied for modeling the radiative transfer through non-homogeneous and non-isothermal combustion gas mixtures generated by the counter flow flames. The results compared with the SNB model show that the WSGGM-RG is successful in modeling the counterflow flames with non-gray gas mixture. The numerical results show that the addition of $CO_2$ and $H_2O$ to the oxidant nozzle lowers the peak temperature and the NO concentration in flame.

  • PDF

Operating Optimization and Economic Evaluation of Multicomponent Gas Separation Process using Pressure Swing Adsorption and Membrane Process (압력 순환 흡착과 막 분리공정을 이용한 다성분 기체의 분리공정 조업 최적화 및 경제성 평가)

  • Kim, Hansol;Lee, Jaewook;Lee, Soobin;Han, Jeehoon;Lee, In-Beum
    • Korean Chemical Engineering Research
    • /
    • v.53 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • At present, carbon dioxide ($CO_2$) emission, which causes global warming, is a major issue all over the world. To reduce $CO_2$ emission directly, commercial deployment of $CO_2$ separation processes has been attempted in industrial plants, such as power plant, oil refinery and steelmaking plant. Besides, several studies have been done on indirect reduction of $CO_2$ emission from recycle of reducing gas (carbon monoxide or hydrogen containing gas) in the plants. Unlike many competing gas separation technologies, pressure swing adsorption (PSA) and membrane filtration are commercially used together or individually to separate a single component from the gas mixture. However, there are few studies on operation of sequential separation process of multi-component gas which has more than two target gas products. In this paper, process simulation model is first developed for two available configurations: $CO_2$ PSA-CO PSA-$H_2$ PSA and $CO_2$ PSA-CO PSA-$H_2$ membrane. Operation optimization and economic evaluation of the processes are also performed. As a result, feed gas contains about 14% of $H_2$ should be used as fuel than separating $H_2$, and $CO_2$ separation should be separated earlier than CO separation when feed gas contains about 30% of $CO_2$ and CO. The simulation results can help us to find an optimal process configuration and operation condition for separation of multicomponent gas with $CO_2$, CO, $H_2$ and other gases.

Composite Gas Measurement System using NDIR Method (NDIR 방법을 이용한 복합 가스 측정 시스템)

  • Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.624-629
    • /
    • 2018
  • The current study was conducted to develop a portable composite gas detector allowing the detection of both $CO_2$ and $CH_4$ gases by means of the Non Dispersive Infra-Red (NDIR) method. The gas detector is configured to radiate infrared waves using infrared lamps, where the wavelength of the infrared light is reduced due to absorption throughout the chamber, and this reduction (absorption) is detected by the absorption detector, before being converted and amplified to a 3.5V~6V electrical signal, providing as accurate a measurement as possible. The conventional singe sensor method measures the relative measurement by absorbing only specified wavelengths of infrared radiation, which in the case of gas detection leads to problems with accuracy due to the lack of a reference sensor when detecting light with a wavelength of only $4.26{\mu}m$. The dual sensor employed in this study provides a comparative measurement between the reference value derived from the wavelength of $3.91{\mu}m$, which is not influenced by other gas sources, and the measurement value derived from the wavelength of $4.26{\mu}m$, in order to reduce the errors and enhance the reliability, thereby allowing low power consumption for portable devices and multi-gas detection for both $CO_2$ and $CH_4$ gases. The portable composite gas detector developed herein provides a measurement rage of 0ppm~5,000ppm for $CO_2$ gas, and 0.5%vol for $CH_4$, which allows the determination of whether the $CO_2$ and $CH_4$ contents in indoor air are less than 1,000ppm or not. The current study established that the composite gas detector can be interlinked with firefighting appliances through portable devices or home automation, and is anticipated to be very effective in fire prevention.

The EEG Spectrum Analysis for the $(CO_2)$ gas Concentration Change in the Autonmobile (자동차 실내가스 $(CO_2)$ 농도변화에 대한 EEG 변화 연구)

  • 백운이;최낙진;서지영;김민정;임정옥;허증수;이덕동
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.57-62
    • /
    • 1998
  • The objectice of this study is to dvaluate the physical condition response of a drever by the change of CO$^{2}$ concentration in the automobile with EEG spectrum analysis. The experiment was performed in a semi-shielded simulated automobile with 10 healthy adults. The results showed that as CO$_{2}$ concentration increased from 500ppm to 6,000ppm, the $\alpha$' value significantly decreased(p*<0.05) while $\beta$' increased (p*<0.05). In a real parked automobile with 2 adult passengers, the CO$_{2}$ gas concintration reached at 6,000ppm in 15 minutes. These spectral data are in well agreement with the subject's verval statement of experiencing uncomfortableness when CO$_{2}$gas was increased ti over 5,000ppm. These results indecated that the EEG spectrum analysis can be appropriately used to assess physical condition of a driver in the changing automobile environment.

  • PDF

Temperature Compensation of NDIR $CO_2$ Gas Sensor implemented with ASIC Chip (ASIC칩내장형비분산 적외선 이산화탄소 가스센서의 온도보상)

  • Park, Jong-Seon;Cho, Hee-Chan;Yi, Seung-Hwan
    • 한국가스학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.123-128
    • /
    • 2006
  • This paper describes NDIR $CO_2$ gas sensor that shows the characteristics of temperature compensation. It consists of novel optical cavity that has two elliptical mirrors and a thermopile detector that includes ASIC chip in the same metal package for the amplification of detector output voltage and temperature sensor. The newly developed sensor modules shows high accuracy (less than +/-40 ppm) throughout the measuring concentration of $CO_2$ gas from 0 ppm to 2,000 ppm. After implementing the calculation methods of gas concentration, which is based upon the experimental results, the sensor module shows high accuracy less than +/- 5 ppm error throughout the measuring temperature range $(15^{\circ}C\;to\; 35^{\circ}C)$ and gas concentrations.

  • PDF

Shelf-Life Extension of Cooked Squid Using Modified Atmosphere Packaging (환경기체조절포장에 의한 자숙오징어의 Shelf-Life 연장)

  • 양승택
    • Journal of Life Science
    • /
    • v.10 no.1
    • /
    • pp.61-67
    • /
    • 2000
  • An experiment was conducted for extension of shelf-life of cooked squid (Todarodes pacificus) using modified atmosphere packaging. The products were packed in a Ny/PE/LLDPE (0.015/0.045/0.040 mm) laminated film with air, vacuum, CO2 gas, and N2 gas, respectively, and then stored at 5$^{\circ}C$ and 2$0^{\circ}C$. Keeping qualities of the products were investigated by measuring moisture content, H, volatile basic nitrogen (VBN), viable cell count, thiobarbituric acid (TBA) value, peroxide value (POV) and color value. Good qualities of the products stored at 5$^{\circ}C$were maintained at least 9 days, 11 days, more than 35 days and 24 days in air, vacuum, CO2 gas and N2 gas packaging products, respectively. In cases of 2$0^{\circ}C$ storage, however, the shelf-lives of all the products were only one day. The shelf-life extension of the products were observed in CO2 ga>N2 gas>vacuum>air packaging in order.

  • PDF

Removal CO2 Using Na2CO3, K2CO3 and Li2CO3 Impregnated Activated Carbon -Characteristics of CO2 Adsorption in Fixed Bed Reactor- (Na2CO3, K2CO3 및 Li2CO3 첨착활성탄을 이용한CO2 제거 -고정층 반응기에서의 CO2 흡착특성-)

  • Choi, Won-Joon;Jung, Jong-Hyeon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.240-246
    • /
    • 2008
  • The purpose of this study was to gain basic information on the characteristics of $CO_2$ adsorption in relation to $Na_2CO_3$, $K_2CO_3$, $Li_2CO_3$-impregnated activated carbon in a Fixed Bed Reactor. From the results of this study the following conclusions were made: $Na_2CO_3$, $K_2CO_3$, $Li_2CO_3$-impregnated activated carbon had a longer breakthrough time and more enhanced adsorption capacity than activated carbon alone. When tested with isothermal adsorption and tested for $CO_2$ adsorption the amount of $CO_2$ adsorbed varied with temperature, $CO_2$ inlet concentration, gas flow rate, aspect ratio, etc. Based on the results, when Langmuir, Freundlich and Dubinin-Polanyi adsorption isotherms were used for linear regression of isothermal adsorption data, Langmuir adsorption isotherm was the most suitable. And, the optimum condition for $Na_2CO_3$ and $K_2CO_3$ impregnated activated carbon make-up was 1N and $Li_2CO_3$ was 0.1N. It could be concluded that adsorption capacity was decreased with adsorption temperature and increased gas concentration. When the aspect ratio (L/D) was varied 0.5, 1.0 and 2.0, the significant drop of adsorption amount was observed below 1.0 and breakthrough time was shortened with gas flow rate.