• Title/Summary/Keyword: $CO_2$ monitoring

Search Result 917, Processing Time 0.031 seconds

Estimating carbon dioxide uptake in wetland ecosystems of Tumen River Basin using eddy covariance flux data (에디 공분산 기반의 플럭스 타워 관측자료를 이용한 두만강 유역 습지 생태계 CO2 흡수량 분석)

  • Chen, Pengshen;Zhao, Shuqing;Cui, Guishan;Lee, Dongkun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.27 no.3
    • /
    • pp.67-74
    • /
    • 2024
  • In the context of rapid temperature rise in mid-to-high latitude regions, cold region wetlands have become a hotspot for current wetland carbon cycle research due to their high sensitivity to climate change. Strengthening the monitoring of CO2 fluxes in wetland ecosystems is of great practical significance for clarifying the carbon balance of wetlands and maintaining the ecological balance of wetland ecosystems in China's high latitude regions. In this study, the carbon flux (NEE, Net ecosystem exchange; GPP, Gross Primary Production; RECO, Ecosystem response) of Jingxin Wetland was monitored by eddy correlation method from August 2021 to March 2024.2022-2023 shows CO2 sinks, absorbing 349.4 g C·m-2·yr-1 annually. The correlation analysis showed that Ta, VPD and PPFD were the main environmental factors affecting CO2 flux in Jingxin wetland.

EPR Studies of the Active Sites of Carbon Monoxide Dehydrogenase from Clostridium thermoaceticum

  • Shin, Woonsup;Lindahl, Paul A.
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.869-876
    • /
    • 1995
  • The active sites of the nickel and iron-containing enzyme, carbon monoxide dehydrogenase (CODH) from clostridium thermoaceticum were investigated using Electron Paramagnetic Resonance (EPR) technique. CODH exhibits several spectral features called NiFeC, $g_{ave}=1.82$, $g_{ave}=1.86$. FCII signals which are originated from different clusters in this enzyme. CODH is know to catalyze two different kinds of reactions - acetyl-CoA synthesis and CO oxidation. The acetyl-CoA synthesis activity can be followed by monitoring CO/acetyl-CoA exchange. The addition of 1,10-phenanthroline (phen) to CODH selectively destroyed the CO/acetyl-CoA exchange activity and eliminated the NiFeC signal completely. CO oxidation activity and other EPR signals were unaffected. Such behavior demonstrates that CODH has two distinct active sites and that the NiFe complex is only responsible for the CO/acctyl-CoA exchange activity. Phen caused the removal of only 30% of Ni in the NiFe complex ($0.3Ni/{\alpha}{\beta}$) as shown by the quantitative metal analysis. The phen-treated CODH could be reactivated fully by incubation In $Ni^{2+}$ solution. Radioactive $^{63}Ni^{2+}$ was used to quantitate the amount of the $Ni^{2+}$ incorporated into phen-treated enzyme and showed that the amount was the same as the removed by the phen treatment. i.e. $0.3Ni/{\alpha}{\beta}$. This indicates that only 30% of NiFe complexes are labile and responsible for the CO/acctyl-CoA exchange activity, the other 70% are non-labile and have no exchange activity. This is the first clear evidence that the NiFe complex is heterogencous and labile and non-labile Ni sites arc interacting differently with substrates and chelating agents like phen.

  • PDF

Evaluation on Air Quality inside Subway Driver Cabin by Monitoring PM, $CO_2$, and CO Levels (서울 일부 지하철 승무원석의 PM, 이산화탄소, 일산화탄소 모니터링에 의한 실내 공기질 특성 평가)

  • Kwag, Hyun-Suk;Jin, Ku-Won;Kim, Won;Yang, Won-Su;Choi, Sang-Jun;Park, Dong-Uk
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.5 s.86
    • /
    • pp.379-386
    • /
    • 2005
  • [ $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$ ] in driver cabins of subway line from 5 to 8 were monitored from 07:00 through 21:00 (or 19:30 or 20:00) on May. Driver cabin of subway line 7 showed the highest $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$ concentrations. General Linear Model indicated that subway line, subway location (ground and underground track) and running time (morning and afternoon) significantly influenced the concentrations of $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$ (p=0.000). Daily profile of $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$, expressed as an 30 minutes average, showed similar variation pattern over day period. These concentrations showed the highest concentrations between 07:00 and 09:00 of rush hour, slightly dropped and again rose slightly after 18:00. In correlation analysis, significant relations among $PM_{10},\;PM_{2.5},\;CO_2\;and\;CO$ were detected (p<0.01). In particular, correlation coefficient between $PM_{10}\;and\;PM_{2.5}$ was highly significant (r=0.884). Regression analysis also concluded that $PM_{10}$ concentration significantly explained 71.4% of variation of $PM_{2.5}$ concentration (p=0.000, $R^2=0.714$). Correlations by CO with $PM_{10}\;and\;PM_{2.5}$ were 0.451 and 0.520, which were higher than those by $CO_2$. Further study is needed to examine the sources of $PM_{2.5}$ and CO in subway and to compare pollutants concentration among subway lines.

Scheme on Environmental Risk Assessment and Management for Carbon Dioxide Sequestration in Sub-seabed Geological Structures in Korea (이산화탄소 해양 지중저장사업의 환경위해성평가관리 방안)

  • Choi, Tae-Seob;Lee, Jung-Suk;Lee, Kyu-Tae;Park, Young-Gyu;Hwang, Jin-Hwan;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.307-319
    • /
    • 2009
  • Carbon dioxide capture and storage (CCS) technology has been regarded as one of the most possible and practical option to reduce the emission of carbon dioxide ($CO_2$) and consequently to mitigate the climate change. Korean government also have started a 10-year R&D project on $CO_2$ storage in sea-bed geological structure including gas field and deep saline aquifer since 2005. Various relevant researches are carried out to cover the initial survey of suitable geological structure storage site, monitoring of the stored $CO_2$ behavior, basic design of $CO_2$ transport and storage process and the risk assessment and management related to $CO_2$ leakage from engineered and geological processes. Leakage of $CO_2$ to the marine environment can change the chemistry of seawater including the pH and carbonate composition and also influence adversely on the diverse living organisms in ecosystems. Recently, IMO (International Maritime Organization) have developed the risk assessment and management framework for the $CO_2$ sequestration in sub-seabed geological structures (CS-SSGS) and considered the sequestration as a waste management option to mitigate greenhouse gas emissions. This framework for CS-SSGS aims to provide generic guidance to the Contracting Parties to the London Convention and Protocol, in order to characterize the risks to the marine environment from CS-SSGS on a site-specific basis and also to collect the necessary information to develop a management strategy to address uncertainties and any residual risks. The environmental risk assessment (ERA) plan for $CO_2$ storage work should include site selection and characterization, exposure assessment with probable leak scenario, risk assessment from direct and in-direct impact to the living organisms and risk management strategy. Domestic trial of the $CO_2$ capture and sequestration in to the marine geologic formation also should be accomplished through risk management with specified ERA approaches based on the IMO framework. The risk assessment procedure for $CO_2$ marine storage should contain the following components; 1) prediction of leakage probabilities with the reliable leakage scenarios from both engineered and geological part, 2) understanding on physio-chemical fate of $CO_2$ in marine environment especially for the candidate sites, 3) exposure assessment methods for various receptors in marine environments, 4) database production on the toxic effect of $CO_2$ to the ecologically and economically important species, and finally 5) development of surveillance procedures on the environmental changes with adequate monitoring techniques.

  • PDF

Distribution Characteristics between Line and Line for Indoor Air Pollutant Factors at Subway Stations in Seoul Area (서울지역 지하철역의 공기 중 오염인자의 노선별 분포 특성)

  • 김민영;라승훈;신도철;한규문;최금숙;정일현
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.2
    • /
    • pp.134-144
    • /
    • 1998
  • A comprehensive air quality monitoring was carried out to investigate the criteria concentration of air pollutant in indoor of subway stations of Seoul City. The samples were collected twice per year (the first and the second half of the year) at each sampling point from February to September in 1997. Sampling point of subway stations was ticket office and platform. The measurement of indoor air pollutants such as sulfur dioxide(SO$_2$), nitrogen dioxide(NO$_2$), carbon monoxide(CO), carbon dioxide(CO$_2$), total suspended particulate(TSP) was performed to determine the indoor air quality. Heavy metals(Pb, Cd, Cu, Cr, As, Hg) were also measured together with those air pollutants. The annual average concentration of CO$_2$ and TSP in subway stations were relatively high while those of heavy metals were within 10% of environmental recommended standard concentration in all stations. As results of regression analysis between line and line of air factors, the concentrations of CO, CO$_2$, TSP, Pb, Cd, Cr and Cu were highly correlated, but those of $SO_2, NO_2$ and Hg were not correlated. As results of regression analysis between ticket office and platform, the concentrations of heavy metals such as Cr and Cu were highly correlated. Results of oneway analysis of variance between the first and the second half of the year air factors also indicated that CO, CO$_2$, Cd, Cu, Hg were significant($\alpha$=0.01), respectively. The average contration of total suspended particulate(TSP) in subway line No. 1 was shown high concentration(200 $\mu g/m^3\cdot$ day) level.

  • PDF

An Embedded system for real time gas monitoring using an ART2 neural network

  • Cho, Jung-Hwan;Shim, Chang-Hyun;Lee, In-Soo;Lee, Duk-Dong;Jeon, Gi-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.479-482
    • /
    • 2003
  • We propose a real time gas monitoring system for classifying various gases with different concentrations. Using thermal modulation of operating temperature of two sensors, we extract patterns of gases from the voltage across the load resistance. We adopt the relative resistance as a pre-processing method and an ART2 neural network as a pattern recognition method. The proposed method has been implemented in a real time embedded system with tin oxide gas sensors, TGS 2611, 2602 and an MSP430 ultra-low power microcontroller in the test chamber.

  • PDF

A Study on the Application of Real-time Environment Monitoring System in Underground Mines using Zigbee Technology (지그비 기술을 이용한 지하광산 내 실시간 환경 모니터링 시스템 현장 적용 연구)

  • Park, Yo Han;Lee, Hak Kyung;Seo, Man Keun;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.29 no.2
    • /
    • pp.108-123
    • /
    • 2019
  • In recent years, as safety management in underground mines has become more important in the worldwide, mine safety management technologies combining information communication technology such as real-time worker position tracking, monitoring system and equipment remote control have been developed. Wireless communication system is mainly applied to these technologies for the flexibility of network configuration. There are some cases the monitoring system was installed in domestic underground mines, but, it is necessary to develop the technology more suitable for domestic mining standard. In this study, we developed the real-time environmental monitoring system using ZigBee technology and examined the result of application to domestic limestone mine. Furthermore, applicability of the developed environment monitoring system to $VentSim^{TM}$ LiveView was checked. This study is expected to contribute to the related studies like the optimization of the ventilation system in underground mines.

Change of End-tidal PCS During Cardiopulmonary Bypass (체외순환시 호기말 이산화탄소압의 변화)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1399-1403
    • /
    • 1992
  • The evaluation of the effectivess of ongoing cardiopulmonary resucitation efforts is dependent on the commonly used methods, such as the presence of femoral or carotid artery pulsations, arterial blood gas determinations, peripheral arterial pressure and intracardiac pressure monitoring. But recent studies suggest that end-tidal carbon dioxide tension serves as a non-invasive measurement of pulmonary blood flow and therefore cardiac output under constant ventilation. A prospective clinical study was done to determine whether end-tidal carbon dioxide monitoring in open heart surgery under cardiopulmonary bypass could be used as a prognostic indicator of bypass weaning. We monitored end-tidal PCO2 values continuously during cardiopulmonary bypass in 30 patients. "Ohmeda 5210 CO-2 monitor" under infrared absorption method were incorperated into the ventilator circuit by means of a side point adaptor between endotracheal tube and ventilator tubing. 18 patients[Group I ] were res-ucitated from partial bypass followed by aorta cross clamp off and 12 patients[Group II ] from aorta cross clamp off followed by partial bypass. But there was no difference between two groups[p>0.05]. The value of end-tidal carbon dioxide tension during ventricular fibrillation or nearly arrest state was 6.6$\pm$2.9 mmHg, and at the time of spontaneous beating was 19.3$\pm$5.6 mmHg[Mean$\pm$Standard deviation], In conclusion end-tidal carbon dioxide tension monitoring provides clinically useful, continous, noninvasive and supplementary prognostic indicator during cardiopulmonary bypass weaning procedures.rocedures.

  • PDF

A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Kim, Jung-Bok;Kim, Young-Kyun;Jin, Hyung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.2
    • /
    • pp.77-81
    • /
    • 2009
  • An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 $\mu$R/h and 2.9 $\mu$R/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.

The Flow and Water Quality Estimation of CSOs Using EC Data and Civil Engineering Research Model (전기전도도 및 토연모델을 이용한 CSOs 유량 및 수질 추정)

  • Choi, Wonsuk;Chung, Chulkwon;Nam, Jungyoon;Koo, Wonseok;Jung, Kwangsu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.3
    • /
    • pp.178-184
    • /
    • 2014
  • In this study, monitoring method which is more economic and easier in maintenance comparing to existing monitoring system was scrutinized for application to sewer intercepting chamber of 10.2 ha basin area by estimating CSOs (Combined Sewer Overflows) quantity and quality with 2 rainfall events using electrical conductivity data and civil research model. The result showed that determination coefficient of flow estimation by EC (Electrical Conductivity) dilution ratio and observed data was over 0.86 for all cases and the accuracy of estimation was improved from 0.5 to 0.8 for determination coefficient ($R^2$) and from 54.1% to 68.5% for accumulation frequency of relative error by considering antecedent dry days and rainfall duration. CSOs water quality estimation results by civil research model showed that determination coefficients were 0.64~0.97 for BOD and 0.70~0.95 for SS.