• 제목/요약/키워드: $CO_2$ injection rate

검색결과 238건 처리시간 0.023초

디젤기관의 연료분사시기가 배기배출물 특성에 미치는 영향 (Effects of Fuel Injection Timing on Exhaust Emissions Characteristics in Diesel Engine)

  • 임재근;최순열
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 추계학술대회 논문집(Proceeding of the KOSME 2001 Autumn Annual Meeting)
    • /
    • pp.50-56
    • /
    • 2001
  • A study on the exhaust emissions of diesel engine with various fuel injection timing is peformed experimentally. In this paper, fuel injection timing is changed from BTDC $14^{\circ}$ to $20^{\circ}$ by $2^{\circ}$ intervals, the experiments are performed at engine speed 1800rpm and from load 25% to 100% by 25% intervals, and main measured parameters are fuel consumption rate, Soot, NOx. HC and CO emissions etc. The obtained conclusions are as follows (1) Specific fuel consumption is indicated the least value at BTDC $18^{\circ}$ of fuel injection timing and it is increased in case of leading the injection timing. (2) Soot emission is decreased in case of leading fuel injection timing and it is increased in the form of convex downwards with increasing the load. (3) $NO_x$ emission is increased in case of leading fuel injection timing and it is increased in the form of straight line nearly with increasing the load. (4) HC and CO emissions are decreased in case of leading fuel injection timing and they are changed in the form of convex downwards with increasing the load.

  • PDF

세라믹 사출성형체로부터 초임계이산화탄소를 이용한 파라핀왁스의 제거 (Removal of Paraffin Wax from Ceramic Injection Mold Using Supercritical Carbon Dioxide)

  • 김동현;홍승태;유기풍;임종성
    • 청정기술
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2008
  • 초임계이산화탄소를 이용하여 세라믹 사출성형체로부터 파라핀왁스를 제거하였다. 파라핀왁스는 세라믹사출성형 공정에서 바인더로 사용되는 물질이다. 파라핀왁스 제거의 최적조건을 찾기 위해 온도, 압력, 이산화탄소의 유량에 대한 영향을 조사하였다. 온도는 328.15 - 348.15 K, 압력은 15 - 30 MPa 범위에서 조절하였으며, 이산화탄소의 유속을 변화시켜가면서 파라핀왁스의 제거율을 측정하였다. 파라핀왁스의 제거율은 압력의 증가에 비례하였다. 온도는 파라핀왁스의 녹는점인 329.15K 이상일 때 파라핀왁스의 제거가 효과적이었고, 더 높은 온도에서는 더 이상의 효과가 없었다. 이산화탄소의 유량 증가에 따라 파라핀 제거율이 향상되었지만 어느 양 이상이 되면 더 이상 효과가 없었다. 파라핀왁스를 보다 더 효과적으로 제거하기 위해 프로판을 공용매로 사용하였다. 초임계이산화탄소에 프로판을 첨가했을 경우 제거율이 향상되었으며, 사출성형체의 구조나 모양에 어떠한 변화도 없이 파라핀왁스를 완전하게 제거할 수 있었다.

  • PDF

Improvement of Fluid Transfer Using Pneumatic Fracturing, Plasma Blasting, and Vacuum Suction

  • Lee, Geun-Chun;Song, Jae-Yong;Kang, Cha-Won;Jang, Hyun-Shic;Jang, Bo-An;Park, Yu-Chul
    • 지질공학
    • /
    • 제32권1호
    • /
    • pp.127-142
    • /
    • 2022
  • This study explored the fluid transfer characteristics of simultaneous pneumatic blasting, plasma blasting, and vacuum suction (the PPV method), and assessed their effect. Chemical oxidation-an established soil remediation method-was compared as a control. Electrical resistivity surveys found that PPV reduced resistivity by about 1.5-2.5 times compared with the control group, indicating that it increased the diffusion of fluid between the injection and suction wells. Injection and suction tests comparing the injection flow rate, initial suction flow rate time, and suction flow rate showed that the PPV method offered an improvement over the existing method. Slug tests revealed that PPV increased the permeability coefficient by a greater amount than that by the control method. This study qualitatively and quantitatively confirmed that the PPV method clearly improves injection and suction efficiency by accelerating cracks in the ground and improving water permeability compared with the established chemical oxidation method.

구강 점막 하 주입 Midazolam과 경구 투여한 Chloral Hydrate의 용량에 따른 산소 포화도 및 생징후 변화에 대한 비교 연구 (Effect of Submucosal Midazolam on Percutaneous Saturation Percentage of Oxygen ($SpO_2$), End-tidal Carbon Dioxide ($EtCO_2$) and Physiologic Response When Combined with Chloral Hydrate, Hydroxyzine and Nitrous Oxide Sedation)

  • 유지혜;김윤희;정상혁;백광우
    • 대한치과마취과학회지
    • /
    • 제6권2호
    • /
    • pp.89-97
    • /
    • 2006
  • Background: The aim of this study was to examine the difference of $SpO_2$, PR, $EtCO_2$, RR with submucosal injection of midazolam to oral chloral hydrate and hydroxyzine for pediatric patients Methods: Thirty two sedation cases were performed in this study. Patients were randomly classified into one group taking oral CH (60 mg/kg). hydroxyzine (1 mg/kg) and submucosal injection of midazolam (0.1 mg/kg) and the other group recieving oral CH (50 mg/kg), hydroxyzine (1 mg/kg) and submucosal injection of midazolam (0.2 mg/kg). For evaluating the depth of sedation. data including saturation percentage of oxygen ($SpO_2$), pulse rate (PR), end-tidal carbon dioxide ($EtCO_2$), respiratory rate (RR) and the behavior scale were checked every 2 minutes and were collected for only 40 minutes from the beginning of treatment and were analyzed using Two independent sample T-test. Results: Analysis showed no significant difference in the mean $SpO_2$, PR, $EtCO_2$, RR during sedation between two groups (P > 0.05). The values of $SpO_2$, PR, $EtCO_2$ and RR for both groups remained within the normal values. Conclusions: The results of this present study indicate that combination of oral CH, hydroxyzine, nitrous oxide gas inhalation and submucosal injection of midazolam improved the sedation quality without compromising safety.

  • PDF

Potentiometric Determination of L-Malate Using Ion-Selective Electrode in Flow Injection Analysis Syste

  • Kwun, In-Sook;Lee, Hye-Sung;Kim, Meera
    • Preventive Nutrition and Food Science
    • /
    • 제4권1호
    • /
    • pp.79-83
    • /
    • 1999
  • A potentiometric biosensor employing a CO3-2 ion-selective electrode(ISE) and malic enzyme immobilization in al flow injection analysis (FIA) system was constructed. Analytical parameters were optimized for L-malate determination . The CO3-2 -ISE-FIA system was composed of a pump, an injector, a malic enzyme (EC1.1.1.40) reactor, a CO3-2 ion-selective electrode, a pH/mV meter and a recorder. Cofactor NADP was also injected with substrate for theenzyme reaction into the system. Optimized analytical parameters for L-malate determination in the CO3-2 ISE-FIA system were as follows ; flow rate, 14.5ml/hr ; sample injection volume, 100ul; enzyme loading in the reactor, 20 units ; length of the enzyme reactor , 7 cm ; tubing length form the enzyme reactor to the detector as a geometric factor in FIA, 15 cm . The response time for measuring the entire L-malate concentration range (10-2 ~10-5 mol/L ; 4 injections )was <15minutes . In this CO3-2 -ISE-FIA system, the potential differences due to th eformation of CO3-2 by the reaction of malic enzyme on L-malate were correlated to L-malate concentration in the range of 10-2 ~10-5mol/L ; the detection limit was 10-5 mol/L. This potentionmetric CO3-2 ISE--FIA system was found to be useful for L-malate measurement.

  • PDF

Combined Treatment of Stromal Vascular Fraction and Ablative Fractional CO2 Laser for Hypertrophic Foot Scar

  • Kim, Dong Gyu;Park, Eun Soo;Kim, Seok Hwan
    • Medical Lasers
    • /
    • 제8권2호
    • /
    • pp.90-93
    • /
    • 2019
  • The treatment of keloid and hypertrophic scars (HTSs) remains one of the most difficult challenges, with a high recurrence rate regardless of the method of treatment. The latest trend in scar management is a combined approach using multiple modalities that are individualized to the patient and that would provide successful results for keloid and HTSs. There are previous reports that stromal vascular fraction (SVF) is effective for scar remodeling. Based on these reports, we introduced the concept of a combination treatment using SVF injection and fractional ablative CO2 laser. In this report, we present a 21-year-old woman who was involved in a car accident. A defect on her foot was covered with a skin graft, but the scars became elevated, which turned out to be HTSs. She was treated with a fractional ablative CO2 laser for five sessions. A month later, SVF injection and fractional ablative CO2 laser were conducted simultaneously. The result of a year's follow-up showed a flattened scar with resolution of pigment deposition. In conclusion, the combination treatment for HTSs with SVF injection and ablative fractional CO2 laser is one of the modalities to achieve an excellent outcome for treating HTS.

WC-Co계 분말사출성형에서 초임계$CO_2$에 의한 결합제 제거 (Binder Removal by Supercritical $CO_2$ in Powder Injection Molded WC-Co)

  • 김용호;임종성;이윤우;김소나;박종구
    • 한국분말재료학회지
    • /
    • 제8권2호
    • /
    • pp.91-97
    • /
    • 2001
  • The conventional debinding process in metal injection molding is very long time-consuming and unfriendly environmental method. Especially, in such a case of injection molded parts from hard and fine metal powder, such as WC-Co, an extremely long period of time is necessary in the conventional slow binder removal process. On the other hand, supercritical debinding is thought to be the effective method which is appropriate to eliminate the aforementioned inconvenience in the prior art. The supercritical fluid has high diffusivity and density, it can penetrate quickly into the inside of the green metal bodies, and extract the binder. In this paper, super-critical debinding is compared with wicking debinding process. Wax-based binder system is used in this study. The binder removal rate in supercritical $CO_2$ have been measured at $65^{\circ}C$, 75$^{\circ}C$ in the pressure range from 20 MPa to 28 MPa. Pores and cracks in silver bodies after sintering were observed using SEM When the super-critical $CO_2$ debinding was carried out at 75$^{\circ}C$, almost all the wax (about 70 wt% of binder) was removed in 2 hours under 28 MPa and 2.5 hours under 25 MPa.

  • PDF

솔레노이드 밸브를 이용한 카복시 건의 주입량 제어 (Injection volume control of carboxy-gun using a solenoid valve)

  • 탁태오;한남규;신영규
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.65-70
    • /
    • 2012
  • Carboxy-guns are used for rapid and precise injection of $CO_2$ gas to the target skin area using external power source. In the design of carboxy-gun, the most important thing is how to precisely control injection volume of $CO_2$ gas. This paper deals with the control scheme of injection volume of carboxy-gun using solenoid valve. First the amount of volume that passes through the solenoid valve under on-off time ratio control is estimated based on the assumption of compressible gas flow. The flow rate of gas is experimentally measured under the varying pressure of the gas reservoir. Two results showed good correlation to each other, thus demonstrating the validity of the volume control strategy.

  • PDF

Powder Injection Molding of Translucent Alumina using Supercritical Fluid Debinding

  • Kim, Hyung Soo;Byun, Jong Min;Suk, Myung Jin;Kim, Young Do
    • 한국분말재료학회지
    • /
    • 제21권6호
    • /
    • pp.407-414
    • /
    • 2014
  • The powder injection molding process having advantages in manufacturing three-dimensional precision parts essentially requires a debinding process before sintering to remove the binders used for preparing feedstock. In this study, powder injection molding of translucent alumina was performed, and carbon dioxide ($CO_2$) is used as a supercritical fluid that makes it possible to remove a large amount of binder, which is paraffin wax. The relationship between the optical property of translucent alumina and the debinding condition (temperature and pressure) of supercritical $CO_2$ was investigated. As temperature and pressure increased, extraction rate of the binder showed rising tendency and average grain size after sintering process was relatively fine. On the other hand, optical transmittance was reduced. As a result, the debinding condition at $50^{\circ}C$ and 20 MPa that represents the lowest extraction rate, $8.19{\times}10^{-3}m^2/sec$, corresponds to the largest grain size of $14.7{\mu}m$ and the highest optical transmittance of 45.2%.

수소-예혼합 압축착화 엔진에서 착화제인 DME/diesel이 엔진 연소에 미치는 영향 (Effects of DME/Diesel as an ignition promoter on combustion of hydrogen homogeneous charge compression ignition)

  • 전지연;박현욱;배충식
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.37-40
    • /
    • 2013
  • Hydrogen-dimethy ether (DME) and hydrogen-diesel compression ignition engine combustion were investigated and compared each other in a single cylinder compression ignition engine. Hydrogen and DME were used as low carbon alternative fuels to reduce green house gases and pollutant. Hydrogen was injected at the intake manifold with an injection pressure of 0.5 MPa at fixed injection timing, $-210^{\circ}CA$ aTDC. DME and diesel were injected directly into the cylinder through the common-rail injection system at injection pressure of 30 MPa. DME and diesel inejction timing was varied to find the optimum CI combustion to reduce CO, HC and NOx emissions. When DME was injected early, CO and HC emissions were high while NOx emission was low. Fuel consumption, heat release rate, and exhaust emissions were measured to analyze each combustion characteristics of each ignition promoter. Fuel consumption was decreased when diesel was used as an ignition promoter. This is due to the lower volatility of diesel which created more stratified charge than DME.

  • PDF