• 제목/요약/키워드: $CO_2$ flux

검색결과 646건 처리시간 0.033초

FCA 용접의 아크현상에 미치는 Flux Type의 영향 (Effect of Flux Type on Arc Characteristic of FCA Welding)

  • 강성원;오은식;유덕상;안영호
    • Journal of Welding and Joining
    • /
    • 제17권1호
    • /
    • pp.116-123
    • /
    • 1999
  • The $CO_2$ welding with 100% $CO_2$ shielding gas is commonly used because of its cost and efficiency. Arc phenomena of the $CO_2$ welding is influenced by various factors such as chemical compositions of welding wire, shielding gas, welding condition and welding power source etc. In this study, arc phenomena is investigated by using two type of FCW(titania type, semi-metal type). Then, the welding quality and optimum welding condition can be selected. From this study, the following results were obtained; 1) In low current range(140A), FCW up to welding voltage(22V) resulted in a typical short circuit transfer. 2) In high current range(320A), the arc stability in titania FCW of a typical globular transfer is better than that of semi-metal FCW.

  • PDF

Climatological Estimation of Sea Surface CO2 Partial Pressure in the North Pacific Oceans by Satellite data

  • Osawa, Takahiro;Akiyama, Masatoshi;Sugimori, Yasuhiro
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.237-242
    • /
    • 1999
  • As one of the key parameters to determine $CO_2$ flux between air - sea interface, it is quite important to know p$CO_2$, which has involved much uncertainty, mainly due to the complex variations of sea surface p$CO_2$ and the paucity of samples, made in ocean. In order to improve the interrelationship between partial pressure (p$CO_2$) and different physical and biochemical parameters in global sea surface water, a new empirical relation is established to correlate and parameterize p$CO_2$ in the mixed layer using the data from recent WOCE cruises. Meanwhile, by new empirical relation, abundant historical hydrographic and nutrients ship data, Levitus data set and NOAA/AVHRR(SST), p$CO_2$ have been accumulated and applied. Then effort has to be made fur promotion of this study to correlate and parameterize p$CO_2$ in the mixed Layer with different physical and biochemical parameters. and further attribute this huge historical data sets and NOAA/AVHRR(SST) data to estimate p$CO_2$. In this paper we analyzed more interrelationship between the model and ship/satellite data set. Finally, the inter-annual variations of p$CO_2$ in sea are presented and discussed.

  • PDF

Membrane contactor and Carbon Dioxide Separation

  • 이규호
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2002년도 제10회 하계 Workshop
    • /
    • pp.59-101
    • /
    • 2002
  • PVDF is good material for a hollow fiber membrane with high porosity and excellent hydrophobicity. Asymmetric PVDF hollow fiber membranes were prepared by the Loeb-Sourirajan phase inversion method. Asymmetric PVDF hollow fiber membranes could be controlled in pore size and porosity using various additives(LiCl, ZnCl$_2$) and internal coagulants (water, EtOH/water, and DMAc/water mixture). $CO_2$removal efficiency of asymmetric PVDF hollow fiber membranes was 1.2 times high than that of commercialized PP hollow fiber membranes at MEA 5wt% solution. $CO_2$flux of asymmetric PVDF hollow fiber membranes was 2.5 times higher than that of commercialized PP hollow fiber membranes. $CO_2$removal efficiency and absorption rate of asymmetric PVDF hollow fiber membranes were 30 times higher than those of packed column at absorbent $H_2O$. $CO_2$flux of asymmetric PVDF hollow fiber membranes at MEA 5wt% solution was 48 times higher than that of pure water. In the case of MEA 5wt% solution used as an absorbent, the $CO_2$absorption rate and removal efficiency of PVDF hollow fiber membrane were 2.3 times higher than that of a packed column.

  • PDF

THE ELECTROMAGNETIC PROPERTIES OF Mg-Mn FERRITES

  • Lee, D.Y.;Cho, S.I.;Shon, H.J.;Hur, W.D.
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.552-555
    • /
    • 1995
  • The magnetic properties of Mg-Mn ferrites were investigated in the composition range of $Mg_{a}Mn_{b}Fe_{c}O_{4\pm\delta}$ (a+b+c=3) with the addition of $Al_{2}O_{3}$. In $MgO-MnO-Fe_{2}O_{3}$ ternary system, the spinel single phase existed within the composition range of MgO-50 mol%, MnO-70 mol% and $Fe_{2}O_{3}-60\;mol%$. The saturation magnetic flux density increased with the increase of $Fe_{2}O_{3}$ content and showed the maximum at the stoichiometric composition of $(Mg,Mn)Fe_{2}O_{4}$. In $Mg_{x}Mn_{1-x}Fe_{2}O_{4}(x=0.2~0.8)$ system, the saturation magnetic flux density showed the maximum at $Mg_{0.2}Mn_{0.8}Fe_{2}O_{4}$. The addition of $Al_{2}O_{3}$ resulted in the decrease of saturation magnetic flux density but increased the electrical resistivity.

  • PDF

A Separation of manganese (II) and cobalt (II) ions by D2EHPA/TBP-immobilized PolyHIPE membrane

  • Chen, Jyh-Herng;Mai, Le Thi Tuyet
    • Membrane and Water Treatment
    • /
    • 제10권2호
    • /
    • pp.127-137
    • /
    • 2019
  • The D2EHPA/TBP co-extractants immobilized PolyHIPE membrane can be used for the selective separation of Mn (II) from Co (II). By solvent-nonsolvent method, D2EHPA/TBP co-extractants can be effectively immobilized into PolyHIPE membrane. The pore structure of PolyHIPE membrane and the presence of TBP enhance the stability of immobilized co-extractants. The optimal operating conditions for the separation of Mn (II) and Co (II) are feeding phase at pH 5.5, sulfuric acid concentration in the stripping phase of about 50 g/L and stirring speed at 400 rpm. The D2EHPA/TBP co-extractants ratio of 5:1 shows synergetic effect on Mn/Co separation factor about 22.74. The removal rate and recovery rate of Mn (II) is about 98.4 and 97.1%, respectively, while for Co (II) the transport efficiency is insignificant. The kinetic study of Mn (II) transport shows that high initial flux, $J_f^o=80.1({\mu}mol/m^2s)$, and maxima stripping flux, $J_s^{max}=20.8({\mu}mol/m^2s)$, can be achieved with D2EHPA/TBP co-extractants immobilized PolyHIPE membrane. The stability and reusability study shows that the membrane can maintain a long term performance with high efficiency. High purity of Co (II) and Mn (II) can be recovered from the feeding phase and stripping phase, respectively.

단일 높이에서 관측된 저장 플럭스를 사용할 때 발생하는 논의 이산화탄소, 수증기, 현열의 순생태계교환량 오차 (Errors in Net Ecosystem Exchanges of CO2, Water Vapor, and Heat Caused by Storage Fluxes Calculated by Single-level Scalar Measurements Over a Rice Paddy)

  • 문민규;강민석;빈두 말라 타쿠리;이정훈
    • 한국농림기상학회지
    • /
    • 제17권3호
    • /
    • pp.227-235
    • /
    • 2015
  • 에디 공분산 방법(eddy covariance method)을 이용한 이산화탄소($CO_2$), 수증기($H_2O$), 현열(sensible heat)의 순생태계과환량[net ecosystem exchange (NEE)]은 에디 플럭스(eddy flux, $F_c$)와 저장 플럭스(storage flux, $F_s$)의 합으로 어림한다. 스칼라의 흡원과 발원의 세기와 분포, 연직 난류 혼합의 정도에 따라 스칼라의 변화율은 높이에 따라 다르게 나타난다. 따라서 정확한 $F_s$를 얻기 위해서는 프로파일 시스템을 운용하여 높이에 따라 달라지는 스칼라의 변화율을 고려하여야 한다. 하지만 아시아의 대부분의 농경지 관측지에서는 프로파일 시스템을 운용하지 않고, $F_c$ 관측 지점과 지면 사이에서 높이와 관계없이 스칼라 변화율이 동일하다는 가정하에 에디 공분산 시스템에서 관측되는 스칼라 변화율 만으로 $F_s$를 산정한다. 본 연구에서는 논에서 에디 공분산 관측 높이에서 측정된 $F_s$(프로파일 시스템에서 관측된 단일 높이의 스칼라만을 이용한 $F_s$, $F_s_{-single}$)와 프로파일 관측(에디 공분산 관측지점과 지면 사이의 여러 높이에서 스칼라 관측)을 이용한 FS와의 차이를 정량화하고, $F_s_{-single}$로 NEE를 산정할 때 발생하는 오차를 확인하기 위해, 경기도 여주에 위치한 청미천 농경지 플럭스 관측지(Chengmicheon Farmland Korea, CFK)에서 에디공분산 방법과 프로파일 시스템을 이용해 $CO_2$, $H_2O$, 기온($T_a$)의 $F_c$$F_s$를 측정하였다. $CO_2$, $H_2O$, $T_a$는 흡원과 발원의 강도와 분포, 대기 경계층의 안정도에 따라 높이별로 변화율이 달랐고, 그 결과 $F_s_{-single}$$F_s$를 과소 또는 과대 평가하였다[특히, 해질 녘과 해 뜰 녘(0430-0800h와 1630-2000h)에 $CO_2$$F_s$를 평균 21% 과소평가]. $F_s_{-single}$로 인해 발생하는 NEE 계산의 오차는 $F_{CO_2}$의 경우, 하루 중 시간에 따라 밤(2030-0400h), 해 질 녘과 해 뜰 녘에 각각 평균적으로 3%, 2%씩 $F_{CO_2}$를 과소평가했다. 이러한 차이는 $F_{CO_2}$의 야간 자료 보정과 분배의 과정에서 논의 탄소수지를 과소평가하게 할 수 있다. 이와는 다르게 LE, H의 경우 시간에 관계없이 거의 차이를 보이지 않았다.

한반도 논에서의 에디공분산 방법에 의한 $CO_2$와 수증기 플럭스 관측 ($CO_2$ and Water Vapor Flux Measurement by Eddy Covariance Method in a Paddy Field in Korea)

  • 이정택;이양수;김건엽;심교문
    • 한국농림기상학회지
    • /
    • 제7권1호
    • /
    • pp.45-50
    • /
    • 2005
  • 우리나라의 주요 농업 생태계인 논에서 벼 생육기간 중의 CO₂와 에너지 교환을 정량화하고 분석(평가하기 위하여 미기상학적인 방법인 에디 공분산법으로 물질/에너지 플럭스를 측정하였다. 측정장소는 한반도 중부 지방의 대표적인 벼농사 지대인 경기도 이천시 부발읍 신원리 농업과학기술원 이천 시험지 플럭스 측정 지점 (37°18'20.34"N, 127°30'40.46"E)에서 수행되었다. 벼군락 장파복사의 방출은 대기로부터의 장파복사량보다 100Wm/sup -2/정도 많았다. 벼논에서 이앙 후 에너지 배분은 잠열 플럭스로 더 많이 배분되었고, 보웬 비는 0.3-0.7 정도였다. 이앙 후 대기중의 수증기 농도는 이 앙 전에 비하여 2gm/sup -3/ 정도 높아졌다. 벼논에서 CO₂ 농도는 야간이 780~820gm/sup -3/, 주간에는 약 650gm/sup -3/ 정도였다. 일사량 증가에 따른 이산화탄소 흡수량은 엽면적 지수가 높을수록 높았으며 특히 유수 형성기-출수기에서 가장 높았다.

한국형 SPAR(Soil-Plant-Atmosphere-Research) 시스템에서 대용량 관측 자료의 처리 및 품질관리 (Processing and Quality Control of Big Data from Korean SPAR (Soil-Plant-Atmosphere-Research) System)

  • 상완규;김준환;신평;백재경;서명철
    • 한국농림기상학회지
    • /
    • 제22권4호
    • /
    • pp.340-345
    • /
    • 2020
  • 본 연구에서는 첨단 옥외환경조절시설인 SPAR 시스템의 작물 및 환경 관측 자료의 품질 관리와 보증 방법을 최초로 제시하였다. 특히 실시간 군락 CO2플럭스의 경우에는 수집되는 자료의 특성을 고려하여 이상치의 제거와 보정이 병행되어야 함을 확인하였다. 본 연구를 통해 구축된 자료 처리 방법들은 향후 SPAR 자료를 통한 작물 생육 모형 개선에 매우 중요하게 활용될 수 있을 것으로 보인다. SPAR 내 작물과 환경 관련 10분 평균 자료는 국립식량과학원 내 작물 연구 통합 정보시스템(Crop Research Information System, CRIS) 웹사이트(www2.nics.go.kr/cris)에서 이용 가능하다.

The Role of Metal Catalyst on Water Permeation and Stability of BaCe0.8Y0.2O3-δ

  • Al, S.;Zhang, G.
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권3호
    • /
    • pp.212-219
    • /
    • 2018
  • Perovskite type ceramic membranes which exhibit dual ion conduction (proton and oxygen ion conduction) can permeate water and can aid solving operational problems such as temperature gradient and carbon deposition associated with a working solid oxide fuel cell. From this point of view, it is crucial to reveal water transport mechanism and especially the nature of the surface sites that is necessary for water incorporation and evolution. $BaCe_{0.8}Y_{0.2}O_{3-{\alpha}}$ (BCY20) was used as a model proton and oxygen ion conducting membrane in this work. Four different catalytically modified membrane configurations were used for the investigations and water flux was measured as a function of temperature. In addition, CO was introduced to the permeate side in order to test the stability of membrane against water and $CO/CO_2$ and post operation analysis of used membranes were carried out. The results revealed that water incorporation occurs on any exposed electrolyte surface. However, the magnitude of water permeation changes depending on which membrane surface is catalytically modified. The platinum increases the water flux on the feed side whilst it decreases the flux on the permeate side. Water flux measurements suggest that platinum can block water permeation on the permeate side by reducing the access to the lattice oxygen in the surface layer.