• Title/Summary/Keyword: $CO_2$ LASER

Search Result 988, Processing Time 0.025 seconds

An Experimental Study on the Effect of Laser to Bond Strength between Composite Resin and Bovine Teeth (우치치질에 레이저조사시 레진과의 결합강도에 관한 연구)

  • Cho, Ju-On;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.155-172
    • /
    • 1989
  • The purpose of this study is to measure the bonding strength at the enamel and dentin of extracted bovine incisors when they are irradiated by W Nd: YAG, EoQ Nd: YAG, and CW $CO_2$ laser, etched and then attached by composite resin. The laser-irradiated surface, the etched surface after the laser-irradiation and the interface of the treated surface and resin are observed by using scanning electron microscope. The NP Nd:YAG laser is used at the peam power of 207 KW. The EOQ Nd: YAG laser is used at the peak power of 1.15Mk. The CW $CO_2$ laser is used at the energy output of 5W and 10W in enamel; in dentin, at the energy output of 2W. The obtained results were as follows: 1. The shear bond strength of enamel decreased in the following order: EOQ Nd:YAG laser group, NP Nd:YAG laser group, CW $CO_2$ laser groups, unlased group. The unlased group showed a significant difference from EOQ Nd:YAG laser group (P<0.01), NP Nd:YAG laser group (P<0.05), but no significant difference from CW $CO_2$ laser group (P>0.05). 2. The shear bond strength of dentin decreased in the following order: CW $CO_2$ laser group, NP Nd:YAG laser group, unlased group, EOQ Nd:YAG laser group. The unlased group showed a significant difference from CW $CO_2$ laser group (P<0.01), but no significant difference from Nd:YAG laser groups (P>0.05). 3. The scanning electron microscope of enamel revealed irregular microcrack and pore at the surface in the NP Nd:YAG laser group and CW $CO_2$ laser group, but the crackless flat surface in the EOQ Nd:YAG laser group. 4. The scanning electron microscope of dentin revealed obstruction of in most of dentinal tubule and decrease of diameter. 5. The scanning electron microscope of the interface of resin and enamel revealed prominent penetration of resin tag in the EOQ Nd:YAG laser group.

  • PDF

Weld Quality Monitoring and Seam Tracking in Making of Welded Tube using $CO_2$ Laser ($CO_2$ 레이저를 이용한 용접튜브 제조공정에서의 용접선 추적 및 용접품질 모니터링)

  • Suh, Jeong;Lee, Jae-Hoon;Kim, Jeng-O;Kang, Hee-Shin;Lee, Moon-Yong;Jung, Byung-Hun
    • Journal of Welding and Joining
    • /
    • v.21 no.7
    • /
    • pp.34-41
    • /
    • 2003
  • Weld quality monitoring and seam tracking along the butt-joint lengthwise to the tube axis are studied. The material of tube is 60kg/$\textrm{mm}^2$ grade steel sheet, and the longitudinal butt-joint is shaped by 2 roll bending machine. The tube with a thickness of 1.5mm, diameter of 105.4mm and length of 2000mm is successfully obtained by the $CO_2$ laser welding system equipped with a seam tracker and plasma sensor. Experimental results show that the developed welding system can be used for the precision seam tracking and the real-time monitoring of weld quality, and the laser welded tube can be used for car body md component after tubular hydroforming.

Minimization of Welding Defect in $CO_2$ Laser Welded Tube

  • Suh Jeong;Kang Hee-Shin;Lee Jae-Hoon;Park Kyoung-Taik;Lee Moon-Yong;Jung Byung-Hun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.3
    • /
    • pp.19-23
    • /
    • 2005
  • To minimize the weld defect in manufacturing of the welded tube by using $CO_2$ laser, the monitoring of the welding quality and the seam tracking along the butt-joint lengthwise to the tube axis are studied. The longitudinal butt-joint is shaped from $60kgf/mm^2$ grade steel sheet by 2 roll bending method, and welded by the $CO_2$ laser welding system equipped with the seam tracker and plasma sensor. The laser welded tube has the thickness of 1.5mm, diameter of 105.4mm and length of 2000mm. The precise positioning of the laser beam on the butt-joint to be assembled is obtained within $200{\mu}m$ by the laser vision sensor. The artificial defects in the butt-joint are well observed by the signal of plasma intensity measured from the plasma sensor of UV wavelength range within 400nm. The developed $CO_2$ laser tube welding system has the function of the precision seam tracking and the real-time monitoring of the welding quality. In conclusion, the laser welded tube can be used for manufacturing of automobile chassis and components after hydro-forming.

System of stable action waveform by pulse special quality of obstetrics and gynecology pulse style $CO_2$ laser (산부인과 펄스형 $CO_2$ 레이저의 펄스 특성에 의한 안정된 동작파형의 시스템)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.55-57
    • /
    • 2007
  • $CO_2$ laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400ums laser beam in rain focus sacred ground surroundings cellular, tissue without vitiation me by evaporation Poe of very small floor as is clean steam can. Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can. Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF

CO2 Laser micro-structuring of optical fiber with negative conical shape (CO2 레이저를 이용한 음각 원뿔 구조 광섬유 팁 가공 최적화 연구)

  • Yoo, Dongyoon;Choi, Hun-Kook;Sohn, Ik-Bu;Noh, Young-Chul;Jung, Deok;Kim, Young-Sup;Lee, Ho;Kim, Chang-Hwan
    • Laser Solutions
    • /
    • v.18 no.3
    • /
    • pp.14-19
    • /
    • 2015
  • A helical fabricating method using $CO_2$ laser was utilized for producing cone-shaped structure on a silica substrate. Output power and the number of scanning radiation were modified in order to control the structure. The experiment shows that the depth and width of cone-shape were increased with higher output power of the laser and the number of scanning. We demonstrate fabrication of multidirectional side-firing optical fiber with diameter of 440 um using the $CO_2$ laser fabrication technique.

Fabrication of Barrier Ribs for PDP by $CO_2$ Laser Scribing Method ($CO_2$ Laser Scribing법을 이용한 PDP용 격벽 제조)

  • 안정식;이석영;김원용;전형조;이용호;김용석
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.1
    • /
    • pp.57-62
    • /
    • 2000
  • In this study, an attempt was made to demonstrate the possibility of using laser scribing method in manufacturing the barrier ribs of plasma display panel. The scribing with a CO2 laser was conducted on the green tape produced by the doctor blade tape casting method. Among the processing parameters, the quenching gas pressure, shape of mask, and laser power were found to affect the depth and angle of the scibed barrier ribs.

  • PDF

A Study on the Output Characteristics of theraphy $CO_2$laser AC Converter $CO_2$ Laser System using 3 Electrode-type and Ring Blower (교류콘버터 기반에서 3전극 방식의 Theraphy $CO_2$ Laser 가변출력특성의 연구)

  • 김휘영
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.257-260
    • /
    • 2002
  • In this paper, the circuit of AC Choppers for $CO_2$laser Power Supply are proposed and investigated. IGBT-controlled ac voltage regulators, operating at high frequency chopping mode. Chopping-to-supply duty ratio plays an important role in terms of laser output. Laser input energy is varied by controlling the leakage transfomer used with the proposed system. This improved circuit employs a 3 electrode-type and Ring Blower. This improved circuit system has many advantages compared with the conventional SMPS such as simple design requirment, easy implementation, high reliability, low switching loss, and consequently high efficiency. As a result, the maximun output was 16W at duty-ratio of 92%, total gas mixture of $CO_2$: $N_2$: He = 1 : 9 : 15, total pressure of 15torr.

  • PDF

The radio frequency excited slab waveguide CO2 laser (고주파 여기식 슬랩형 도파관 CO2 레이저)

  • 김규식;이영우;우삼용;최종운
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.4
    • /
    • pp.406-412
    • /
    • 2003
  • We have developed a radio frequency excited slab waveguide $CO_2$ laser. The dimension of active volume is 2${\times}$40${\times}$400 mm. One concave and one convex mirror are used to make the unstable resonator of the positive branch. The radio frequency is 123 MHz and RF input power is varied from 100 to 900 W. The laser gas is set to a pressure of 10∼60 torr and the mixing ratio is $CO_2$:$N_2$:He=1:1:3. The laser output power of 70.7 W was obtained which corresponds to laser power to RF power conversion efficiency of 9.2%.

Study on microstructure of sensitized Alloy 600 rapidly solidified by a $CO_2$ laser beam ($CO_2$ 레이저빔을 이용한 예민화된 Alloy 600의 급속응고 미세구조 연구)

  • 임연수;서정훈;국일현;김정수
    • Laser Solutions
    • /
    • v.1 no.1
    • /
    • pp.18-23
    • /
    • 1998
  • A Study on microstructural changes of sensitized Alloy 600 which was rapidly solidified by a $CO_2$ laser beam was conducted using microscopic equipments such as SEM and TEM. Dissolution of Cr-rich carbides and resultant Cr recovery on the grain boundaries occurred in the heat affected zone (HZA). The microstructure of the laser melted zone (LMZ) having epitaxially solidified from the HAZ was mainly celluar-dendritic with the 〈100〉 crystallographic direction of growth. The Cr concentration was observed to increase along the cell bondaries, and tiny particles were distributed along the cell walls with tangled dislocations around them. Cr-rich carbides had been completely melted by the high density of a laser beam, and were not re-precipitated during the matrix solidification due to a fast cooling rate in the LMZ.

  • PDF

A $LN_2$-cooled, Broadband cw CO Laser (액체질소 냉각형광대역 cw CO 레이저)

  • Kim, Y.P.;Choi, J.W.;Won, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.667-671
    • /
    • 1989
  • The CO laser is one of powerful light source for laser magnetic resonance spectroscopy in the mid-infrared region of the spectrum because of its wideband operational characteristics. In this work, a liquid nitrogen cooled cw CO laser is developed to allow broad-band operation from 5 to 8 ${\mu}m$. The design details will be presented.

  • PDF