• Title/Summary/Keyword: $CO_2$ 감축

Search Result 343, Processing Time 0.029 seconds

Structural Change in CO2 Emissions of Annex B Countries Under the Kyoto Protocol (교토의정서 Annex B 국가의 CO2 배출량 구조변화 분석)

  • Kim, Min Jung;Yang, Ji Hye;Kim, Hyun Seok
    • Environmental and Resource Economics Review
    • /
    • v.26 no.2
    • /
    • pp.123-138
    • /
    • 2017
  • This study estimates the effect of the Kyoto Protocol on $CO_2$ emissions with a Quandt-Andrews test for detection of structural break with Annex B counties data. The structural break on $CO_2$ emissions took place in 2008 which is 3 year after ratification of the Kyoto Protocol. According to the empirical results, 1% increase in energy consumption leads to 1% and 0.31% increases in income before and after the structural break, respectively. This study also finds the monotonic increase relationship between $CO_2$ emission and income. Regarding to the relationship between renewable energy use and $CO_2$ emissions, 1% increase in renewable energy consumption leads to 0.1% decrease in $CO_2$ emissions until year 2007 and 0.09% decreases after year 2008, respectively. Based on the results of empirical study, we find little evidence of the effect of the Kyoto Protocol on reduction of $CO_2$ emissions for Annex B countries.

Development of CO2 Emission Factor for Wood Chip Fuel and Reduction Effects (목질계 바이오매스 중 대체연료 우드칩의 온실가스(CO2) 배출계수 개발 및 저감 효과)

  • Lee, Seul-Ki;Kim, Seung-Jin;Cho, Chang-Sang;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.3 no.3
    • /
    • pp.211-224
    • /
    • 2012
  • Technology for energy recovery from waste can reduce the greenhouse gas emissions. So recently, there are several companies using RDF, RPF, WCF instead of using only coal fuel and it's part of the fuel on the increase. In this study, we developed Wood chip fuel $CO_2$ emission factor through fuel analysis. It's moisture content is 23%, received net calorific value is 2,845 kcal/kg, and received basis carbon is 34%. The result of emission factor is $105ton\;CO_2/TJ$, it's 5.9% lower than 2006 IPCC guideline default factor $112ton\;CO_2/TJ$. The gross GHG(Greenhouse gases) emissions of plant A is $178,767ton\;CO_2 eq./yr$, and Net GHG emissions is $40,359ton\;CO_2 eq./yr$. Therefore, the reduction of GHG emissions is $138,408ton\;CO_2/yr$ through using WCF, and I accounts for 77% of all GHG emissions.

Current and Future Trends of District Heating System for a Sustainable Future and Greenhouse Gas Reduction (온실가스 감축 및 지속가능 미래를 위한 집단에너지사업 방향)

  • Jung, Min-Jung;Park, Jin-Kyu;Ahn, Deog-Yong;Lee, Nam-Hoon
    • Journal of Climate Change Research
    • /
    • v.8 no.4
    • /
    • pp.377-384
    • /
    • 2017
  • Amid growing concerns about energy security, energy prices, economic competitiveness, and climate change, district heating (DH) system has been recognized for its significant benefits and the part it can play in efficiently meeting society's growing energy demands while reducing environmental impacts. Policy makers often need to quantify the fuel and carbon dioxide ($CO_2$) emissions savings of DH system compared to conventional individual heating (IH) system in order to estimate its actual emissions reductions. The objective of this paper is to calculate energy efficiency and $CO_2$ emissions saving, and to propose the future direction for DH system in Korea. DH system achieved total system efficiencies of 67.9% compared to 54.1% for IH system in 2015. DH system reduced $CO_2$ emissions by $381,311ton-CO_2$ (4.1%) compared to IH system. The results suggest that DH system is more preferred than IH system using natural gas. In Korea, the aim is to reduce dependence on fossil fuels and to use energy more efficiently. DH system have significant potential with regard to achieving this aim, because DH system are already integrated with power generation in the electricity since combined heating and power (CHP) are used for heat supply. Although the future conditions for DH may look promising, the current DH system in Korea must be enhanced in order to handle future competition. Thus, the next DH system must be integrated with multiple renewable energy and waste heat energy sources.

A Study on the Calculation of $CO_2$ Emission and Road Freight Environmental Index for Logistics Companies (물류기업의 온실가스 배출량 및 도로화물환경지표 산정에 관한 연구)

  • Kim, Jong-Hyeon;Kim, Hong-Sang;Choe, Sang-Jin;Park, Seong-Gyu;Kim, Jeong;Jang, Yeong-Gi
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.2
    • /
    • pp.25-35
    • /
    • 2011
  • In order to reduce Green House Gas(GHG) reduction in the road freight sector and thus establish green logistics, running efficiency of goods vehicles is of paramount importance. Providing effective transportation infrastructure can contribute to achieve the green logistics by reducing empty running of heavy goods vehicles and van, increasing the average payload on the vehicle, and shifting the transportation mode. In order to reduce the environmental impact from the road freight sector, it is essential to quantify the amount of environmental loading from the sector. However, any systematic survey on the environmental loading from the logistics companies has not been carried out in Korea. In this study, the environmental index for the road freight sector is defined as the amount of $CO_2$ emission per ton km generated from goods vehicles. The computational analysis shows that the average $CO_2$ emission per ton km generated by the logistics companies in Korea is $363g-CO_2/ton{\cdot}km$. Compared to UK (=$130g-CO_2/ton{\cdot}km$) and France (=$97g-CO_2/ton{\cdot}km$), the efficiency of logistics in Korea is 2.8 and 3.7 times as low as in the advanced countries. It also indicates that the main reasons for the low efficiency are mainly due to the high rate of empty operation of goods vehicles and the low payload.

The $CO_2$ Recovering Recipe used Oxy Combustion with the Submerged Natural Gas Burner (천연가스 수중연소기(SMV)에서 순산소연소를 활용한 $CO_2$ 회수방안)

  • Sohn, Whaseung;Kim, Hoyeon;Ha, Jongmann;Kim, Joonseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.157-157
    • /
    • 2010
  • 우리나라는 기후변화협약에 대응하기 위한 교토의정서를 비준한 국가로서, 아직 온실가스의 의무감축 대상 국가는 아니다. 그러나 2012년부터 시작될 교토의정서 2차 공약기간 중에 브라질, 중국 및 인도와 같이 2차 의무감축대상이 가장 유력시 되는 국가로 지목되고 있으므로, 이러한 변화에 능동적으로 대처할 수 있는 기술적, 사회적, 정책적 방안이 신속히 마련될 필요가 있다. CCS(carbon capture & storage)란 화석연료로 부터 연소시 대기 중으로 배출되는 온실가스($CO_2$)를 포집하여 재생 또는 지중, 해양에 저장하는 기술로서 국가녹색성장 핵심기술중의 하나로 분류되며, 대료적인 $CO_2$ 발생대상인 석탄화력발전소로 부터 $CO_2$ 회수방안, 회수, 처리관련 연구를 포함하여 국내외 적으로 활발한 연구가 이루어 지고 있다. 순산소 연소기술을 통한 $CO_2$ 회수, 처리기술은 연료(천연가스, 석탄, 석유)의 산화제를 공기대신 순도 95% 이상의 고농도 산소를 이용하여 순산소연소를 하며, 이때 발생하는 배가스의 대부분은 $CO_2$와 수증기로 구성되어 있다. 발생된 배가스의 약 70~80%를 다시 연소실로 재순환시켜 연소기의 열적 특성에 적절한 연소가 가능하도록 최적화함과 동시에 배가스의 $CO_2$ 농도를 80% 이상으로 농축시켜 회수를 용이하게 하며, 특히 공해물질은 NOx 발생량을 10ppM 이하로 줄일 수 있다. 천연가스가 생산되는 LNG기지에서 LNG를 기화시키기 위하여 해수식 기화기(ORV : Open Rack Vaporizer와 수중연소식 기화기(SMV ; Submerged Combustion Vaporizer)를 사용하고 있으며, 특히 SMV는 버너를 이용하여 $-162^{\circ}C$ LNG를 $10^{\circ}C$의 LN로 기화시키는 설비로서 이때 연소시 $CO_2$를 상당량 발생시킨다. 본 논문에서는 SMV에서 순산소 연소방식을 적용하여 연료인 천연가스를 연소시키고, 이때 발생되는 $CO_2$와 수분이 주 성분인 배가스를 연소기에 재순환시켜, 연소실내 고온문제를 해결하며, 최종적으로 배가스중 $CO_2$$-162^{\circ}C$의 LNG 냉열을 이용하여 고순도의 액체 $CO_2$로 액화시키므로서 $CO_2$의 회수, 처리문제를 해결하는 방식을 소개하고자 한다. 이러한 방식은 천연가스에서 발생되는 $CO_2$ 회수를 LNG 냉열을 활용하므로서 폐열을 활용하는 에너지 효율적인 문제와 사용가능한 고순도 $CO_2$로 회수하므로서 환경적인 문제를 처리하는 기술이라 할 수 있다.

  • PDF

Process Analysis on the Decontamination of Internal Surface of $UF_6$ Cylinder ($UF_6$ 실린더 내부표면 제염에 관한 공정분석)

  • Chun, Kwan-Sik;Yoo, Sung-Hyun;Cho, Young-June;Hong, Jang-Pyo;Han, Wook-Jin;Choi, Beong-Soon;Kang, Pil-Sang;Cho, Suk-Ju
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.3
    • /
    • pp.161-165
    • /
    • 2009
  • To evaluate the efficiency of the decontamination plant for the removal of uranium compounds deposited on the internal surface of $UF_6$ cylinder for its reuse, two demonstration tests of the plant with different ratio of ${Na_2}{CO_3}$ and ${H_2}{O_2}$ were carried out, and each test had 5 steps. The main chemical form removed by the tests was to be identified as ${Na_4}{UO_2}(CO_3)_3$. More than 50% of uranium was removed by water of the first step, and at the following steps the removal amounts were exponentially decreased. On the other hand, the result shows that the injected amount of ${Na_2}{CO_3}$, compared with that of the removed uranium, was stoichiometrically excessed. This suggests that the injected amounts of ${Na_2}{CO_3}$, the generation rate of decontaminated waste, and the decontamination steps could be reduced by a process optimization of the plant.

  • PDF

The Estimation of Greenhouse Gas Reductions from Renewable Energy (Photovoltaic, Wind Power) : A Case Study in Korea (재생에너지(태양광, 풍력) 기술의 온실가스 감축산정: 국내를 대상으로)

  • Jung, Jaehyung;Kim, Kiman
    • Journal of Environmental Science International
    • /
    • v.29 no.7
    • /
    • pp.729-737
    • /
    • 2020
  • This study estimates the greenhouse gas (GHG) emissions reduction resulting from photovoltaic and wind power technologies using a bottom-up approach for an indirect emission source (scope 2) in South Korea. To estimate GHG reductions from photovoltaic and wind power activities under standard operating conditions, methodologies are derived from the 2006 IPCC guidelines for national GHG inventories and the guidelines for local government greenhouse inventories of Korea published in 2016. Indirect emission factors for electricity are obtained from the 2011 Korea Power Exchange. The total annual GHG reduction from photovoltaic power (23,000 tons CO2eq) and wind power (30,000 tons CO2eq) was estimated to be 53,000 tons CO2eq. The estimation of individual GHGs showed that the largest component is carbon dioxide, accounting for up to 99% of the total GHG. The results of estimation from photovoltaic and wind power were 63.60% and 80.22% of installed capacity, respectively. The annual average GHG reductions from photovoltaic and wind power per year per unit installed capacity (MW) were estimated as 549 tons CO2eq/yr·MW and 647 tons CO2eq/yr·MW, respectively. Finally, the results showed that the level of GHG reduction per year per installed capacity of photovoltaic and wind power is 62% and 42% compared to the CDM project, respectively.

A Study of Consequence Analysis of Physical Explosion Damage in CO2 Storage Tank (CO2 임시 저장 탱크에서의 물리적 폭발에 따른 피해영향 고찰)

  • Seo, Doo-Hyoun;Jang, Kap-Man;Lee, Jin-Han;Rhie, Kwang-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.2
    • /
    • pp.12-19
    • /
    • 2015
  • $CO_2$ is non-flammable, non-toxic gas and not cause of chemical explosion. However, various impurities and some oxides can be included in the captured $CO_2$ inevitably. While the $CO_2$ gas was temporarily stored, the pressure in a storage tank would be reached above 100bar. Therefore, the tank could occur a physical explosion due to the corrosion of vessel or uncertainty. Evaluating the intensity of explosion can be calculated by the TNT equivalent method generally used. To describe the physical explosion, it is assumed that the capacity of a $CO_2$ temporary container is about 100 tons. In this work, physical explosion damage in a $CO_2$ storage tank is estimated by using the Hopkinson's scaling law and the injury effect of human body caused by the explosion is assessed by the probit model.

An Application of CDM Project for Greenhouse Gas Reduction Activities in the Wastewater Treatment Systems (하수처리시스템 온실가스 저감활동에 대한 CDM 사업 적용에 관한 연구)

  • Kwak, In-Ho;Hwang, Young-Woo;Jo, Hyun-Jung;Park, Kwang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.3
    • /
    • pp.319-332
    • /
    • 2010
  • In general, wastewater treatment systems consume high-energy consumption depending on operation characteristics of the facilities. Therefore, greenhouse gas(GHG) reduction activities that are application of digestion gas, induction of renewable energy etc. are conducted to reduce energy consumption and to increase energy independence ratio. In this study, GHG reduction in wastewater treatment system identified, searched application of Clean Development mechanism(CDM) approved methodology. If the methodologies apply to GHG reduction activities such as application of digestion gas, heat pump system using the wastewater as heat source, hydropower using the methodology determined CDM applicability, otherwise through several assumptions calculated expectable GHG reduction emissions and determined CDM applicability. As a result, the order of calculated GHG reduction emission showed that collected and energy generation of digestion gas is 66,775 $tCO_2$/yr, gas engine cogeneration system is 8,182 $tCO_2$/yr, heat pump system using the wastewater as a heat source is 72,715 $tCO_2$/yr, and hydropower is 561 $tCO_2$/yr. Consequently, the order of calculated Certified Emission Reductions(CERs) benefit showed that heat pump system using the wastewater, as a heat source is 1,381 million won/yr was estimated as the highest, followed by a collected and energy generation of digestion gas is 1,268 million won/yr.

Interfuel Substitution and Carbon Dioxide Emission in the Transportation Sector: Roles of Biodiesel Blended Fuels (수송부문의 연료 간 대체와 이산화탄소 배출: 바이오디젤 혼소 효과를 중심으로)

  • Hyonyong Kang;Dong Hee Suh
    • Environmental and Resource Economics Review
    • /
    • v.32 no.1
    • /
    • pp.27-46
    • /
    • 2023
  • This paper investigates how interfuel substitution affects carbon dioxide (CO2) emissions with a focus on the use of biodiesel blended fuels. The results show that the Divisia elasticity of diesel demand is the greatest because the transportation sector relies heavily on diesel. Also, while the own-price elasticity of each fuel demand is negative, the results reveal that diesel demand is more inelastic than the demand for gasoline and LPG. Moreover, gasoline is a substitute for diesel and electricity, and diesel is a substitute for LPG and a complement for electricity. Regarding the effects on carbon dioxide emissions, this paper computes the potential CO2 emissions associated with interfuel substitution using the coefficients of CO2 emissions. The results show that using biodiesel blended fuels contributes to reducing CO2 emissions, but it appears that the price-induced interfuel substitution is a main factor affecting CO2 emissions.