• Title/Summary/Keyword: $COP_c$

Search Result 318, Processing Time 0.036 seconds

Combined Modality Therapy of Non-Hodgkin's Lymphoma of Waldeyer's Ring (Waldeyer's Ring 비호치킨 림프종의 병합요법)

  • Park In-Kyu;Yun Sang-Mo;Park Jun-Sik;Kim Jae-Cheol
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.1
    • /
    • pp.22-28
    • /
    • 1999
  • Purpose: We performed this study retrospectively to evaluate local control, survival, prognostic factors, and failure patterns in patients with non-Hodgkin's lymphoma of Waldeyer's ring. Materials and Methods: From April 1984 to November 1996,41 patients with non-Hodgkin's lymphoma of Waldeyer's ring were treated with combined chemotherapy and radiation therapy. Age was ranged from 19 to 73 years old with a median age of 55 years, and there were 26 male and 15 female patients. Primary site was tonsil in 26 and base of the tongue in 7 and nasopharynx in 8, and stage distribution showed stage I in 12 and stage II in 29 patients. Pathologic classification was done according to Working Formulation. There were 1 with follicular mixed small cleaved and large cell, 8 with diffuse small cleaved cell, 7 with diffuse mixed small and large cell, and 25 cases with diffuse large cell. All patients were treated with combination of chemotherapy and radiation therapy. Chemotherapy regimen consisted of either CHOP-Bleo(cyclophosphamide, adriamycin, vincristine, prednisolone, bleomycin) or COP-BLAM III(cyclophosphamide, vincristine, prednisolone, bleomycin, adriamycin, procarbazine). Radiation dose ranged from 3600cGy to 6620cGy with a median dose of 5040cGy. Follow-up time was ranged from 15 months to 159 months(median 55 months). Results: The complete response was achieved in 98%(40/41) and partial response in 2%(1/41). The complete response rate were the followings: 66.7% for stage I and 51.7% for stage II after chemotherapy, 100% for stage I and 96.6% for stage II after overall treatment respectively. The overall survival rate and disease-tree survival rates at 5 years were 82.6% and 79.5%, respectively. Prognostic factors for overall survival were age(p=0.007), stage(p=0.03), nodal status(p=0.006) and radiation dose(p=0.003). The factors associated with disease-tree survival were stage(p=0.04), nodal status(p=0.004) and radiation dose(p=0.009). The failure patterns were analized in evaluable 35 patients with complete response. Locoregional failure was noted in 2 patients and distant metastasis in 5 patients. Conclusion: Our results suggest that combined modality therapy is the appropriate treatment for stage I-II intermediate grade non-hodgkin's lymphoma of the Waldeyer's ring. However, our material is small and the analysis is retrospective. Randomized prospective studies for combined therapy, radiation therapy alone and chemotherapy alone are needed.

  • PDF

Performance Improvement of an Air Source Heat Pump by Storage of Surplus Solar Energy in Greenhouse (온실 내 잉여 태양열을 이용한 공기열원 히트펌프 성능향상)

  • Kwon, Jin Kyung;Kang, Geum Chun;Moon, Jong Pil;Kang, Youn Ku;Kim, Chung Kil;Lee, Su Jang
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.328-334
    • /
    • 2013
  • A greenhouse heating system to improve heat pump performance using inside and outside air of greenhouse as a heat source selectively and cut $CO_2$ enrichment costs by delay of greenhouse ventilation was developed. In this system, thermal storage modes divided into inside circulation mode using surplus solar energy and outside circulation mode using outside air heat. The thermal storage modes were designed to be switched mutually according to inside greenhouse temperature and six temperature values were input to control the heat pump operating, thermal storage mode switching and greenhouse heating automatically. Operating characteristics of this system were tested in a plastic greenhouse of non-ventilation condition. The results of test showed that the inside circulation mode began at about 11:00 and lasted for about 210 minutes and inside greenhouse temperature was maintained between $20{\sim}28^{\circ}C$ in spite of non-ventilation. System heating COP of the inside circulation mode in the daytime was 3.35, which was 36% and 25% higher than that of the outside circulation modes in the nighttime and daytime respectively.

Heating Performance Analysis of the Heat Pump System for Agricultural Facilities using the Waste Heat of the Thermal Power Plant as Heat Source (발전소 폐열을 이용한 농업시설용 히트펌프시스템의 난방 성능 분석)

  • Kang, Youn Koo;Kang, Suk Won;Paek, Yee;Kim, Young Hwa;Jang, Jae Kyung;Ryou, Young Sun
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.317-323
    • /
    • 2017
  • In this study, the heating performance and the energy saving effect of the heat pump system using hot waste water(waste heat) of the thermal power plant discharged from a thermal power plant to the sea were analyzed. The greenhouse area was $5,280m^2$ and scale of the heat pump system was 120 RT(Refrigeration Ton), which was divided into 30 RT, 40 RT and 50 RT. The heat pump system consisted of the roll type heat exchangers, hot waste water transfer pipes, heat pumps(30, 40, 50 RT), a heat storage tank and fan coil units. The roll type heat exchangers was made of PE(Poly Ethylene) pipes in consideration of low cost and durability against corrosion, because hot waste water(sea water) is highly corrosive. And the heating period was 5 months from October to February. During the heating performance test(12 hours), the inlet water temperature of evaporator was changed from $32^{\circ}C$ to $26^{\circ}C$, and heat absorption of he evaporator was changed from 175 kW to 120 kW. The inlet water temperature of the condenser rose linearly from $15^{\circ}C$ to $50^{\circ}C$, and the heat release of condenser was reduced by 40 kW from 200 kW to 160 kW. And the power consumption of the heat pump system increased from 30 kW to 42 kW. When the inlet water temperature of condenser was $15^{\circ}C$, the heating COP(Coefficient Of Performance) was over 7.0. When it was $30^{\circ}C$, it dropped to 5.0, and when it was above $40^{\circ}C$, it decreased to less than 4.0. It was analyzed that the reduction of heating energy cost was 87% when compared to the duty free diesel that the carbon dioxide emission reduction effect was 62% by recycling the waste heat of the thermal power plant as a heat source of the heat pump system.

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

Hydrolysis of Agricultural Residues and Kraft Pulps by Xylanolytic Enzymes from Alkaliphilic Bacillus sp. Strain BK

  • Kaewintajuk Kusuma;Chon Gil-Hyong;Lee Jin-Sang;Kongkiattikajorn Jirasak;Ratanakhanokchai Khanok;Kyu Khin Lay;Lee John-Hwa;Roh Min-Suk;Choi Yun-Young;Park Hyun;Lee Yun-Sik
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.8
    • /
    • pp.1255-1261
    • /
    • 2006
  • An alkaliphilic bacterium, Bacillus sp. strain BK, was found to produce extracellular cellulase-free xylanolytic enzymes with xylan-binding activity. Since the pellet-bound xylanase is eluted with 2% TEA from the pellet of the culture, they contain a xylan-binding region that is stronger than the xylan-binding xylanase of the extracellular enzyme. The xylanases had a different molecular weight and xylan-binding ability. The enzyme activity of xylanase in the extracellular fraction was 6 times higher than in the pellet-bound enzyme. Among the enzymes, xylanase had the highest enzyme activity. When Bacillus sp. strain BK was grown in pH 10.5 alkaline medium containing xylan as the sole carbon source, the bacterium produced xylanase, arabinofuranosidase, acetyl esterase, and $\beta$-xylosidase with specific activities of 1.23, 0.11, 0.06, and 0.04 unit per mg of protein, respectively. However, there was no cellulase activity detected in the crude enzyme preparation. The hydrolysis of agricultural residues and kraft pulps by the xylanolytic enzymes was examined at 50$^{\circ}C$ and pH 7.0. The rate of xylan hydrolysis in com hull was higher than those of sugarcane bagasse, rice straw, com cop, rice husk, and rice bran. In contrast, the rate of xylan hydrolysis in sugarcane pulp was 2.01 and 3.52 times higher than those of eucalyptus and pine pulp, respectively. In conclusion, this enzyme can be used to hydrolyze xylan in agricultural residues and kraft pulps to breach and regenerate paper from recycled environmental resources.

Patent Trend Analysis of Carbon Capture/Storage/Utilization Technology (이산화탄소 포집/저장/활용 기술 특허 동향 분석)

  • Bae, Junhee;Seo, Hangyeol;Ahn, Eunyoung;Lee, Jaewook
    • Economic and Environmental Geology
    • /
    • v.50 no.5
    • /
    • pp.389-400
    • /
    • 2017
  • In December 2015, 195 nations agreed to cut green house gas emissions in the Paris Climate Convention, and all over the world showed their willingness to participate in greenhouse gas mitigation. Accordingly, various technologies related to greenhouse gas reduction are being considered, among which carbon dioxide capture, storage, utilization (CCUS) technologies are attracting attention as an unique technology capable of directly removing greenhouse gases. However, CCUS technologies are still costly and have low efficiency. It is still more important to analyze the level of CCUS technology before commercialization and to understand trends and to predict future direction of technology. Therefore, this study analyzes the patent trends of CCUS technology and derives implications for future directions. As a result of country analysis, the United States had the highest number of applications, and sectoral analysis shows that 64% of total patents are from capture sector. Companies such as Alstom technology, Toshiba Corp, and Mitsubishi Heavy are focusing on capturing carbon dioxide. In Korea, government research institutes have focused on storage and utilization technologies. In addition, since the late 2000s, patent applications have increased rapidly, and many countries have been interested in the development of the technology and have made efforts to reduce greenhouse gas.

The Effect of Additional Elements on the Tailored Magnetic Properties of Electrochemically Prepared CoPtP-X Alloys (전기화학적으로 제조한 CoPtP-X합금의 첨가제 효과에 따른 맞춤형 자기적 성질)

  • Park, H.D.;Lee, K.H.;Kim, G.H.;Jeung, W.Y.;Choi, D.H.;Lee, W.Y.
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.2
    • /
    • pp.94-98
    • /
    • 2005
  • Coptp films with the additive elements (X=Fe, Mn) of varying concentrations were prepared by in-situ electrodeposition, to tailor their magnetic properties. Alloys of CoPtP-X (X=Fe, Mn) were synthesized by changing the solution concentrations of Fe and Mn for electrodeposition. In the electrodeposited CoFePtP alloys, preferred orientation of the electrodeposited films changed from hexagonal (001) to (100) direction with increasing iron contents as revealed by X-ray diffraction, and these films exhibited various magnetic properties ranging from a typical hard magnetic to a soft magnetic property in accordance with microstructural variations. In the case of Mn addition, excellent hard magnetic property was observed at a specific Mn concentration of 0.0126 M in the electrolyte, with the coercivity of 4630 Oe and squareness of 0.856 and this was attributed to the fact that magnetization easy-axis (hexagonal c-axis) coincides with the preferred growth orientation of the film confirmed by transmission electron microscopy.

Load-Settlement Behavior of Rock-socketed Drilled Shafts by Bi-directional Pile Load Test (양방향 말뚝선단재하시험에 의한 암반근입 현장타설말뚝의 하중-침하거동 분석)

  • Seol, Hoon-Il;Jeong, Sang-Seom;Han, Keun-Taek;Kim, Jae-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.61-70
    • /
    • 2008
  • Load settlement behaviors and load transfer characteristics of rock-socketed pile subjected bi-directional load at pile tip were investigated using bi-directional pile load tests (BD PLT) performed on ten large-diameter drilled shafts at four sites. Based on test results, additional pile-toe displacement ($w_{bs}$) by coupled soil resistance was analyzed, and thus equivalent top loaded load-settlement curve of pile subjected bi-directional load was proposed by taking into account the coupled soil resistance. Through comparisons with field case studies, it is found that for test piles there exists effect of coupled soil resistance, which is represented by wbs, and thus an equivalent curve obtained by existing uncoupled methods can overestimate bearing capacity of piles by BD PLT. On the other hand, the analysis by the proposed method with soil coupling effect has a considerably larger settlement when compared with the results by uncoupled load transfer method and estimates reasonable load-settlement behaviors of test piles. In case of pile socketed in high strength rocks, however, effects of coupled soil resistance can be neglected.